centro ricerche-sviluppo e laboratori prove Date received: 06-11-12 Date of issue: 05-12-12 33048 S. Giovanni al at. UD OMP S.R.L. VIA CA' LEOCIO, 2 31030 CASTELLO DI GODEGO (TV) Report consists of 4 test reports. Defects before testing: one Sample name: PORTA VEEZIA SAMPLE 149279 Overall dimensions: 400 x 480 x 810 (h) mm List performed tests: 1. Seat and back static load test E 1728:2000 2. Seat and back fatigue test E 1728:2000 3. Seat front edge durability test E 1728:2000 4. Seat impact test E 1728:2000 Page 1 of 2
33048 S. Giovanni al at. UD Sample weight: ot determined Sample name: PORTA VEEZIA SAMPLE 149279 Side view Rear view Bottom view report relates to the sample submitted for the test and no others. Additions, deletions or alterations are not permitted. This test report must always be Page 2 of 2
33048 S. Giovanni al at. UD 149279 / 1 Date of test: 13-11-12 Sample name: PORTA VEEZIA VIA CA' LEOCIO, 2! Seat and back static load test E 1728:2000 Seat and back static load test, clause 6.2.1 Seat load Back force umber of cycles 2.000 650 10 o defects ote: According to E 1728:2000, back force has been reduced from 700 to 650 to avoid tipping. Seat front edge static load, clause 6.2.2 Seat load umber of cycles 2.000 10 o defects ote: The test has been carried out according to table 1 of E 15373:2007, level 3 - severe. The standard E 1728:2000 has been withdrawn and superseded by E 1728:2012.
33048 S. Giovanni al at. UD 149279 / 2 Date of test: 13-11-12 Sample name: PORTA VEEZIA VIA CA' LEOCIO, 2! Seat and back fatigue test E 1728:2000 Seat and back fatigue test, clause 6.7 Seat force Back force umber of cycles 1.000 300 200.000 o defects ote: The test has been carried out according to table 1 of E 15373:2007, level 3 - severe. The standard E 1728:2000 has been withdrawn and superseded by E 1728:2012.
33048 S. Giovanni al at. UD 149279 / 3 Date of test: 26-11-12 Sample name: PORTA VEEZIA VIA CA' LEOCIO, 2! Seat front edge durability test E 1728:2000 Seat front edge durability test, clause 6.8 Points of application Seat force umber of cycles 80 mm back from the front edge 1.000 100.000 o defects ote: The test has been carried out according to table 1 of E 15373:2007, level 3 - severe. The standard E 1728:2000 has been withdrawn and superseded by E 1728:2012.
33048 S. Giovanni al at. UD 149279 / 4 Date of test: 04-12-12 Sample name: PORTA VEEZIA VIA CA' LEOCIO, 2! Seat impact test E 1728:2000 Seat impact test, clause 6.15 Mass of impactor kg Height of drop mm umber of drops 25 300 10 o defects ote: The test has been carried out according to table 1 of E 15373:2007, level 3 - severe. The standard E 1728:2000 has been withdrawn and superseded by E 1728:2012.