FAC 7.1: Generators. EPA Impacts on Emergency Gensets for 2015 Installations

Similar documents
EPA Requirements for Diesel Standby Engines In Data Centers. Bob Stelzer / CTO / Safety Power Inc. For 7x24 Fall 2014 Conference. 1.

EPA s Air Quality Regulations for Stationary Engines

EPA s Air Quality Regulations. Melanie King U.S. Environmental Protection Agency

Understanding Tier 4 Interim and Tier 4 Final EPA regulations for generator set applications

EPA emission regulations: What they mean for diesel powered generating systems

Air Permitting in Colorado. Martha Hyder Wind River Environmental Group LLC September 2013

Site Identification No.: AAO Application No.:

Statement of Basis SCA Tissue North America, LLC

Air Pollution s, 1950s. Air Pollution Laws 1950s

Implementation Question and Answer Document. for

COMMONWEALTH OF MASSACHUSETTS DEPARTMENT OF ENVIRONMENTAL PROTECTION 310 CMR 7.00 AIR POLLUTION CONTROL REGULATIONS

Air Permit Application Volume II Warren County Combined-Cycle Project

Prepared for: The INGAA Foundation, Inc. By: Innovative Environmental Solutions, Inc. & Optimized Technical Solutions. July 2014

An overview of Euro VI for trucks over 3.5t. Brought to you by Mercedes-Benz

Policy Measures for Improving Air Quality in the U.S.

POTENTIAL ECONOMIC IMPACTS OF A STRICTER OZONE STANDARD

Class II General Permit G35-C Registration to (Construct, Modify, etc.)

Clean Up Your Fleet. Introducing a practical approach to cleaner, more efficient fleet operation

Colorado PUC E-Filings System

Potential to Emit A Guide for Small Businesses

4. The role of fleets and fleet managers Role of REC?

Oil and Gas Air Quality Regulations and Permitting

Expansion Pitfalls, Permitting and Compliance A Case Study

ENVIRONMENTAL PROTECTION AGENCY. 40 CFR Part 52. [EPA-R10-OAR ; FRL Region 10]

Emission Control Technology for Stationary Internal Combustion Engines

Source: EIA Natural Gas Issues and Trends 1998

4. The role of fleets and fleet managers

State of the Art (SOTA) Manual for Boilers and Process Heaters

Tips for a Successful Diesel Retrofit Project

Pollution by 2-Stroke Engines

The Senate Committee on Natural Resources

Fuel Quality and Vehicle Emission Standards in GCC countries. Name, event, date

EURO VI. Technologies & Strategies. Relatore: M.Maritati Commercial training

Marine after-treatment from STT Emtec AB

Alternative to Fossil Fuel

INDUSTRIAL ENGINE RATINGS GUIDE

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

Notice of Construction Application for Landfill Gas to Pipeline Gas Treatment Facility

AUTOMOTIVE GAS OIL. Robert Shisoka Hydrocarbon Management Consultancy

Marine after-treatment from STT Emtec AB

Meet Clean Diesel. Improving Energy Security. Fueling Environmental Progress. Powering the Economy

ADEM Form /10 m5

Air Quality in San Diego 2013 Annual Report

STATE OF CONNECTICUT DEPARTMENT OF ENVIRONMENTAL PROTECTION BUREAU OF AIR MANAGEMENT

Clean Power for Today

1 March Al Dussinger Embrace Home Loans 25 Enterprise Center Middletown, RI Dear Mr. Dussinger,

ARB s Diesel Emissions Programs

EPA Clean Power Plan and Impact on Texas and the Country. Scott D. Deatherage

FACT SHEET PROPOSED REVISIONS TO THE NATIONAL AMBIENT AIR QUALITY STANDARDS FOR SULFUR DIOXIDE

Bill Maxwell, U.S. Environmental Protection Agency, OAQPS (C439-01)

State of New Jersey. General Permit. For. Boilers and Heaters [Individually Less Than 10 MMBTU/HR]

Assessment of Air Emissions Martin Marietta Materials Facilities on Highway 34, Weld County, Colorado Project No.:

INDEX GENERAL

Engineered Solutions for Exhaust Emissions

HYBRID BUSES COSTS AND BENEFITS

Addition of general construction conditions applicable to the portable emergency turbine because they were omitted from the original Part 70 Permit.

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

2010 NOV 30 P MQ. November 29,2010

The Clean Air Act s Economic Benefits. Past, Present and Future

EFFECTS &BENEFITS LOW SULPHUR DIESEL

STATE OF MISSOURI, DEPARTMENT OF NATURAL RESOURCES MISSOURI AIR CONSERVATION COMMISSION PERMIT TO CONSTRUCT

CLEAN VEHICLE Technologies

Assessing the Changes Required by the Industrial Boiler MACT Regulations

Document Control Program

BOILER EMISSION GUIDE

How To Reduce No 2 Emissions In Nordic Cities

The Use of Exhaust Gas Recirculation (EGR) Systems in Stationary Natural Gas Engines. The Engine Manufacturers Association August 2004

Natural Gas and Transportation

STATE OF NEW HAMPSHIRE STATE IMPLEMENTATION PLAN REVISION

!Rl DEPARTMENT OF NATURAL RESOURCES

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

The Ambient Air Monitoring System

BOILER EMISSION GUIDE

Transcription:

FAC 7.1: Generators EPA Impacts on Emergency Gensets for 2015 Installations Speaker: Bob Stelzer, CTO Safety Power Inc bob.stelzer@safetypower.ca Speaker: Randy Sadler, SME, Safety Power Inc. randy.sadler@safetypower.ca 1

FAC 7.1: Generators In order to get the Air Emissions Permit for Data Centers that have diesel emergency standby generators, it is necessary to comply with EPA and local regulatory requirements. Ensuring that the Data Center design takes into account these regulatory requirements can have a significant impact on overall facility layout and cost. This presentation provides an overview of the EPA regulatory framework that can impact Data Center design and layout. 2

Items Covered Focus of this presentation What Emissions are of Concern? Overall EPA Regulatory Framework Air emissions modeling process Technology to Deal with Air Emissions from Diesel Engines Challenges Facing the Critical Power Engineer Possible Solutions 3

Focus of this Presentation Focus is on the emission requirements for new, large stationary emergency Diesel (aka CI or Compression Ignition ) engines commonly found in new Data Centers This presentation does NOT focus on: Existing or retrofit engines Natural Gas (Spark Ignition) Engines or smaller ( < 500HP) Diesel Engines Operational and reporting requirements once an engine is installed Revenue production / non-emergency use for emergency engines (as of July 2013 the EPA is reviewing possible changes in this area) Special exemptions for remote areas (i.e. Alaska) 4

Emissions of Concern Data Centers that have diesel driven emergency standby generators have the following emissions that are of concern 5

Example of a Data Center Example of a relatively new Data Center running on Diesel Engines during Testing. Note the highly visible smokestacks which attract unwanted attention and the plume of emissions coming from them. 6

Important EPA Nomenclature related to Gensets This presentation uses the following EPA terms and presents a framework that ties them together: NAAQS = National Ambient Air Quality Standards defines the specific pollutants and the acceptable level per geographic area NSPS = New Source Performance Standards regulates new sources put into operation after the rule RICE NESHAP = Reciprocating Internal Combustion Engines National Emissions Standards for Hazardous Air Pollutants regulates new and existing sources EPA Tier 2, 3 4i and 4f = EPA standards used to certify engines from an air emissions standpoint There are many exceptions and special cases in the EPA regulatory framework. This presentation focuses only on new emergency diesel engines > 500HP typically used in large Data Centers 7

Overall EPA Regulatory Framework Clean Air Act (Congress) Title I Air Pollution Prevention & Control Title II Emission Standards for Moving Sources Title VI Ozone Protection Part D Part A EPA Regulatory Program Plan Requirements For Non-Attainment Areas NAAQS/RICE NESHAP/NSPS Office of Air & Radiation Emissions Standards: Diesel Non Road Engines EPA Tier 2,3,4 / Office of Transportation & Air Quality 8

EPA Definition of Emergency To address litigation filed by stakeholders (CSP s Curtailment Service Providers), in January 2013 the EPA proposed the following amendments for Emergency engine operation: Unlimited use for emergencies (e.g., power outage, fire, flood) 100 hr/yr for maintenance/testing and emergency demand response 50 hr/yr of the 100 hr/yr allocation can be used for: local reliability (existing RICE at area sources of HAP only, subject to a NERC North American Electric Corporation - Level 2 call, or when there is a voltage or frequency fluctuation of 5% or more) peak shaving until May 3, 2014 (existing RICE at area sources of HAP only). Be aware that this usage is often over-ridden by local regulatory authorities for example US northeastern states - NESCAUM region - do not generally allow this usage) 9

EPA Regulatory Framework - NAAQS NAAQS National Ambient Air Quality Standard Applies to 6 criteria pollutants Must be met by all states Criteria pollutants include diesel emissions such as Nitrogen Dioxide (NO 2 ), Particulate Matter (PM) and Carbon Monoxide (CO) Timetable for NAAQS implementation varies depending on pollutant http://www.epa.gov/air/criteria.html Non-attainment area Areas are often at the county or major urban center level Attainment or non-attainment determined by EPA Requires an EPA approved State Implementation Plan (SIP) to resolve US Northeast (Maine to Northern Virginia) is called the Ozone Transport Region (OTR) because of population density it has more stringent requirements 10

EPA Regulatory Framework - NAAQS NAAQS for NO 2 (considered the harshest component of NOx) was changed in 2010 to include an hourly worst case of 188 µg/m3 ( 100 ppb) requirement (previously was an annual average). Timeline for implementation: By June 2013 each state must submit a State Implementation Plan (SIP) to ensure attainment By 2017 there must be full compliance with NAAQS for NO 2 Similar NAAQS approach applies for CO and PM Modeling of the emissions sources at the site and its surroundings is used to determine if the site requires emission control devices Bottom Line: NAAQS requirements can result in the requirement for emission control devices on the diesel generators at a Data Center 11

EPA Regulatory Framework - NSPS NSPS New Source Performance Standards Applies only to new installations Typically specifies performance standards that are defined within the EPA Tier levels Most new diesel engines intended for emergency use would readily meet the requirements which are: Tier 2 for engines > 752 HP Tier 3 for smaller engines Bottom line: NSPS is likely not a constraint from the specifying engineer s perspective 12

EPA Regulatory Framework RICE NESHAP RICE NESHAP has had a big impact on existing non-emergency diesel generators However this presentation looks at RICE NESHAP impact on new diesel generators > 500HP used for emergency applications Important terminology: A facility is an Area Source if it has the potential to emit < 10 tons/year of any single hazardous air pollutant or < 25 tons/year of any combination of hazardous air pollutants annually A facility is a Major Source if it can emit more than an Area Source The emissions requirements and implementation timeline are typically more stringent for Major Sources EPA has classified over 70 area source categories i.e. a stationary reciprocating internal combustion engine (RICE), or a boiler Each of these categories has special NESHAP (National Emissions Standards for Hazardous Air Pollutants) requirements 13

EPA Regulatory Framework RICE NESHAP RICE NESHAP typically references NSPS requirements for installations Request the end-user to use Ultra Low Sulfur Diesel (ULSD) which has been a common standard since 2007 Typically RICE NESHAP emissions compliance for new engines > 500HP is accomplished within the engine The facility operator must record emergency operation with reference to a non-resettable hour meter and make available to EPA on request Bottom line: RICE NESHAP is likely NOT a constraint from the specifying engineer s perspective 14

EPA Regulatory Framework Tier 4 Tier 1 was adopted in 1991, the current level is Tier 4 interim (T4i) and by Jan2015 Tier 4 final (T4f) will be in place for nonemergency diesel engines If the engine is not T4 it must have a permanent label indicating for emergency use only There can be some significant disadvantages to using T4 certified engines for DC emergency applications For example if the urea used for NOx reduction runs low the engine will trip Bottom line: EPA T4 is NOT required for emergency diesel engines, but some engine vendors are advocating use of T4 engines to ensure there are no operating restrictions 15

EPA Impacts for New Diesel Emergency Engines > 500HP LAW - provides the authority for the EPA to write Regulations Clean Air Act (Congress) REGULATIONS - explain the implementation details Explanation NAAQS NSPS RICE NESHAP TIER 2/3/4 National Ambient Air Quality Standards New Source Performance Standards Reciprocating Internal Combustion Engine National Emissions Standards for Hazardous Air Pollutants Emissions Standards for Engines (including Stationary) Regulatory Reference for Diesel 40 CFR Part 50 Stationary Engines 40 CFR Part 60 part IIII (for Diesel Engines) 40 CFR Part 63 subpart ZZZZ 40 CFR part 1039, 1065, 1068 for Tier 4 and 40 CFR part 89 for Tier 3 Overview Specifies the allowable limits applies to new stationary for "criteria" pollutants in EPA engines defined geographic "areas" applies to existing AND new stationary engines. applies to new engines used in mobile and stationary applications Latest Amendments Depends on which criteria pollutant is being considered Tier 3 has been in effect since 2008 and Tier 2 (applies to larger engines) since 2005 March 2010 with amendments in Jan 2013 Tier 3 has been in effect since 2008 and Tier 2 (applies to larger engines) since 2005 Implication for Diesel Emergency Engines > 500 HP where there is no intent for revenue generation If large multi-engine installation in a "nonattainment area" and 1 hr test to be conducted at full load may require SCR for NOx reduction to gain air permit Tier 3 or Tier 2 for HP > 752 No reqmts for major sources but best to comply with diesel engine NSPS. Operator may be reqd to follow certain requirements for fuel use, maintenance and reporting Tier 3 or Tier 2 for HP > 752. Must be marked "For emergency use". 16

EPA Impacts for new Diesel Emergency Engines > 500HP RICE NESHAP Likely not a factor If engine is new. Some operational impacts Likely not required for emergency use. Tier 3 (or Tier 2 if engine >752HP) is ok EPA Tier 4 Certified NAAQS constraint likely if: Non-attainment area Installation is large 1 hour worst case is exceeded during testing NAAQS NO 2, etc. Data Center Likely not a factor If engine is new. NSPS 17

Summary: EPA Impacts for Data Centers Assuming the key requirement is to get an air permit for the DC for emergency use of diesel gensets: RICE NESHAP and NSPS requirements have likely been met by the engine manufacturer (since 2008) You likely do NOT need T4 certified engines You may need emission control devices to meet NAAQS requirements: If in a non-attainment area If the Data Center is large (i.e. is an area source) If the 1 hr worst case emissions are exceeded for any criteria pollutant during full load testing 18

Technology to Meet Air Emissions Requirements For diesel engines the available emission control technologies are: Diesel Oxidation Catalyst (DOC) to deal with CO and unburned Hydrocarbons - odor Diesel Particulate Filter (DPF) to meet Particulate Matter (PM) requirements - visual Selective Catalytic Reduction (SCR) to meet NOx requirements Diesel engines used for emergency applications often need to meet NOx requirements based on local permitting requirements 19

Selective Catalytic Reduction SCR is a very well-established and well-known technology to reduce NOx emissions in various applications all over the world. Coal-fired power plants Gas turbines Large marine vessels Diesel cars and trucks Stationary engines

Basic SCR Technology Principle

The Technologies and Capabilities SCR-NOx DPF - PM DOC - HC & CO Typical is 80-95% removal Typical is 70-85% removal Typical is 70-80% removal Can achieve~99% Can achieve ~90% Can achieve ~90% SCR-Selective Catalytic Reduction DPF Diesel Particulate Filter DOC Diesel Oxidation Catalyst NOx Nitrogen Oxides

Example of Combination Diesel Oxidation Catalyst and Diesel Particulate Filter Oxidation Catalyst Filter Oxidation canister = Particulate Filter + Oxidation Catalyst Particulate Filter Bulkhead for FOx modules for 3MW engine 23

Example of Combination SCR, Diesel Oxidation Catalyst, DPF, Silencing enclosure mount 24

25 Example of Combination SCR, Oxidation Catalyst, DPF ceiling mount ecocube Emission Control System Inlet exhaust gas entry Engine Pad

Examples of Emission Control Systems on Diesel Gensets CAT3512 MTU16V4000 C175 MTU 16V4000 CAT 3616C Mitsubishi 1.7MW 26

Challenges Facing the Critical Power Engineer What air emission requirements have to be met? The site location may not yet be finalized The regulations may change between project concept stage and project implementation I want a design that can be used anywhere across the US (or Internationally) How much physical space and what costs must I allocate for the emission control equipment 27

Challenges Facing the Critical Power Engineer SCR mixing tube Traditional approach: Many devices Lots of expansion joints Uses too much space Complex mechanical design High installed cost silencer expansion joints interconnecting piping 28

Possible Solutions to the Challenges Select a modular system that can combine as many functions as possible into a single package. Functions may include: Acoustic control (exhaust silencing) required for most all installations NOx control (requires SCR) required for many installations if DC is large and in a non-attainment area DOC or DPF likely not required today, but may be required when the site seeks its air permit specify a design which allows these functions to be upgraded with no required change in space or piping configuration 29

Possible Solutions to the Challenges Modular design allows a single cube to house any combination of Selective Catalytic Reduction (SCR) 1. with: Diesel Oxidation Catalyst (DOC) Diesel Particulate Filter (DPF) Silencing 30

Space Saving Modular Design

Summary EPA rules are very complex and constantly changing Large diesel emergency generators in data centers may be more constrained by NAAQS requirements than other regulation For large installations, the Critical Power Engineer should consider space saving approach with a Silencer/SCR combination that can be upgraded with no required change in space or piping configuration 32

Thank you Speaker: Bob Stelzer, CTO Safety Power Inc bob.stelzer@safetypower.ca Speaker: Randy Sadler, SME, Safety Power Inc. randy.sadler@safetypower.ca www.safetypower.ca 33