LabChip GX/GXII with LabChip GxP Software



Similar documents
Full Compliance Contents

Thermal Analysis. Subpart A General Provisions 11.1 Scope Implementation Definitions.

21 CFR Part 11 Implementation Spectrum ES

21 CFR Part 11 Compliance Using STATISTICA

Implement best practices by using FileMaker Pro 7 as the backbone of your 21 CFR 11 compliant system.

Electronic records and electronic signatures in the regulated environment of the pharmaceutical and medical device industries

Nova Southeastern University Standard Operating Procedure for GCP. Title: Electronic Source Documents for Clinical Research Study Version # 1

TIBCO Spotfire and S+ Product Family

Oracle WebCenter Content

FDA 21 CFR Part 11 Electronic records and signatures solutions for the Life Sciences Industry

FDA Title 21 CFR Part 11:Electronic Records; Electronic Signatures; Final Rule (1997)

Tools to Aid in 21 CFR Part 11 Compliance with EZChrom Elite Chromatography Data System. White Paper. By Frank Tontala

Compliance Response Edition 07/2009. SIMATIC WinCC V7.0 Compliance Response Electronic Records / Electronic Signatures. simatic wincc DOKUMENTATION

Assessment of Vaisala Veriteq vlog Validation System Compliance to 21 CFR Part 11 Requirements

21 CFR Part 11 Checklist

A ChemoMetec A/S White Paper September 2013

21 CFR PART 11 ELECTRONIC RECORDS, ELECTRONIC SIGNATURES CFR Part 11 Compliance PLA 2.1

Considerations for validating SDS Software v2.x Enterprise Edition for the 7900HT Fast Real-Time PCR System per the GAMP 5 guide

FILEHOLD DOCUMENT MANAGEMENT SYSTEM 21 CFR PART 11 COMPLIANCE WHITE PAPER

InfinityQS SPC Quality System & FDA s 21 CFR Part 11 Requirements

Electronic Document and Record Compliance for the Life Sciences

21 CFR Part 11 Electronic Records & Signatures

Data Management PACT Workshop: Design & Operation of GMP Cell Therapy Facilities April 10 th -11 th, 2007

DeltaV Capabilities for Electronic Records Management

For technical assistance, please contact: Thermo Nicolet Corporation 5225 Verona Road Madison WI

DeltaV Capabilities for Electronic Records Management

endless One platform possibilities for DNA, RNA, protein and cell analysis Agilent 2100 Bioanalyzer Our measure is your success.

The Impact of 21 CFR Part 11 on Product Development

Declaration of Conformity 21 CFR Part 11 SIMATIC WinCC flexible 2007

Software Manual Part IV: FDA 21 CFR part 11. Version 2.20

REGULATIONS COMPLIANCE ASSESSMENT

rsdm and 21 CFR Part 11

Using Chromeleon Chromatography Management Software to Comply with 21 CFR Part 11

Using the Thermo Scientific Dionex Chromeleon 7 Chromatography Data System (CDS) to Comply with 21 CFR Part 11. Compliance Guide

SOLAARsecurity. Administrator Software Manual Issue 2

Software. For the 21 CFR Part 11 Environment. The Science and Technology of Small Particles

Implementing Title 21 CFR Part 11 (Electronic Records ; Electronic Signatures) in Manufacturing Presented by: Steve Malyszko, P.E.

Eclipsys Sunrise Clinical Manager Enterprise Electronic Medical Record (SCM) and Title 21 Code of Federal Regulations Part 11 (21CFR11)

Agilent MicroLab Software with Spectroscopy Configuration Manager and Spectroscopy Database Administrator (SCM/SDA)

Compliance Response SIMATIC SIMATIC PCS 7 V8.1. Electronic Records / Electronic Signatures (ERES) Edition 03/2015. Answers for industry.

Compliance Matrix for 21 CFR Part 11: Electronic Records

ScreenMaster RVG200 Paperless recorder FDA-approved record keeping. Measurement made easy

Compliance in the BioPharma Industry. White Paper v1.0

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

SolidWorks Enterprise PDM and FDA 21CFR Part 11

Guidance for Industry Computerized Systems Used in Clinical Investigations

Considerations When Validating Your Analyst Software Per GAMP 5

OPERATIONAL STANDARD

AutoSave. Achieving Part 11 Compliance. A White Paper

Waters Empower Software Seamlessly Manages Regulated Data to Aid in 21 CFR Part 11 Compliance

InfoCenter Suite and the FDA s 21 CFR part 11 Electronic Records; Electronic Signatures

Guidance for Industry COMPUTERIZED SYSTEMS USED IN CLINICAL TRIALS

Waters Empower 2 Software Seamlessly Manages Regulated Data to Aid in 21 CFR Part 11 Compliance

Review and Approve Results in Empower Data, Meta Data and Audit Trails

Implementation of 21CFR11 Features in Micromeritics Software Software ID

Testing Automated Manufacturing Processes

Computerized Systems Used in Medical Device Clinical Investigations

Guidance for electronic trial data capturing of clinical trials

epblue GxP oftware manual Software version

21 CFR Part 11 White Paper

SHIMADZU CORPORATION

Empower TM 2 Software

Spectroscopy Configuration Manager (SCM) Software. 21 CFR Part 11 Compliance Booklet

How To Control A Record System

CoSign for 21CFR Part 11 Compliance

Sponsor Site Questionnaire FAQs Regarding Maestro Care

Clinical database/ecrf validation: effective processes and procedures

This interpretation of the revised Annex

Self-Assessment of eresearch Compliance with 21 CFR Part 11, Electronic Record; Electronic Signatures

Meeting the FDA s Requirements for Electronic Records and Electronic Signatures (21 CFR Part 11)

Intland s Medical Template

Analyst 1.6 Software. Laboratory Director s Guide

INTRODUCTION. This book offers a systematic, ten-step approach, from the decision to validate to

Computerised Systems. Seeing the Wood from the Trees

Guidance for Industry. 21 CFR Part 11; Electronic Records; Electronic Signatures. Electronic Copies of Electronic Records

Manual 074 Electronic Records and Electronic Signatures 1. Purpose

Xcalibur. Foundation. Administrator Guide. Software Version 3.0

THE ROLE OF WATERS NUGENESIS SDMS IN 21 CFR PART 11 COMPLIANCE

Implementing CitectSCADA to meet the requirements of FDA 21 CFR Part 11

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

User Guide for the 21 CFR Part 11 Module in SDS Software v1.4

testo Saveris 21CFR Part 11 Software Instruction manual

Octet System Data Analysis User Guide

Supplement to the Guidance for Electronic Data Capture in Clinical Trials

M-Files QMS. Out-of-the-Box Solution for Daily Quality Management

Author: Ryan J Adams. Overview. Policy Based Management. Terminology

Risk-Based Approach to 21 CFR Part 11

Guidance for Industry Part 11, Electronic Records; Electronic Signatures Scope and Application

Back to index of articles. Qualification of Computer Networks and Infrastructure

Agilent 280-DS Mechanical Qualification System for Dissolution Apparatus 1 and 2

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

POLICY ISSUES IN E-COMMERCE APPLICATIONS: ELECTRONIC RECORD AND SIGNATURE COMPLIANCE FDA 21 CFR 11 ALPHATRUST PRONTO ENTERPRISE PLATFORM

FileMaker Security Guide The Key to Securing Your Apps

OECD DRAFT ADVISORY DOCUMENT 16 1 THE APPLICATION OF GLP PRINCIPLES TO COMPUTERISED SYSTEMS FOREWARD

GCP INSPECTORS WORKING GROUP <DRAFT> REFLECTION PAPER ON EXPECTATIONS FOR ELECTRONIC SOURCE DOCUMENTS USED IN CLINICAL TRIALS

NetWrix Account Lockout Examiner Version 4.0 Administrator Guide

MHRA GMP Data Integrity Definitions and Guidance for Industry January 2015

LabX titration Software

WatchDox Administrator's Guide. Application Version 3.7.5

Microsoft Dynamics GP. Electronic Signatures

Transcription:

Regulatory Compliance LabChip GX/GXII with LabChip GxP Software Supporting Regulatory Compliance Caliper LabChip GX/GXII suite of instruments provides automated electrophoresis to analyze quality, size, and concentration, of DNA, RNA, and proteins. Caliper LabChip GxP Software enables the users to run the instruments in regulated environments, such GLP (Good Laboratory Practice), GCP (Good Clinical Practice), or GMP (Good Manufacturing Practice), commonly referred as GxP. 1

The Importance of Qualification of Analytical Instruments and Validation of Computerized Systems In the regulated environments, users are required to qualify analytical instruments for their intended use, to maintain the instruments on a regular basis to ensure the performance, and to keep the maintenance records. If the instruments are computerized, the users are subject to 21 CFR Part 11 requirements, which include validation of systems, audit trails, copies of records, record retention, and other provisions. Among several models of qualification of analytical instruments and validation of computerized systems, the following 4Q approach has been commonly used: Design Qualification (DQ) Installation Qualification (IQ) Operation Qualification (OQ) Performance Qualification (PQ) In 2008, the United States Pharmacopeia (USP) incorporated this 4Q approach and published USP Chapter <1085> titled Analytical Instrument Qualification, the compendial procedure for pharmaceutical industries. Caliper is fully aware of our customer requirements in terms of DQ, IQ, OQ, PQ, and 21 CFR Part 11 compliance. This white paper describes how our services and our products are able to address your needs using our systems in regulated environments. Design Qualification Caliper Life Sciences, Inc. is ISO 9001-2000 certified (Figure 1). Caliper product development is based on ISO 9001 2000 Design Control Process. Our instruments and software systems have been thoroughly tested before release to ensure that the products conform to their design specification. Caliper has well established customer support and service programs to assure that our customers get adequate support using our systems. Figure 1. ISO 9001-2000 Certificate 2

Installation Qualification Caliper provides full services for on-site installation qualification. In addition to that, our checklist and step-by-step instructions for installation qualification allow our customers to perform installation qualification themselves on an as needed basis. Moreover, the LabChip GxP Software has a built-in IQ tool to automate the software installation qualification (Figure 2). Users have options to save the IQ results to a file for future reference or to review the details of IQ results and to print out the results for documentation purpose. Figure 2. Software Installation Qualification Tool The IQ tool comes in handy for checking software installation qualification after each computer system maintenance or service routine, such as disk cleanup, installing antivirus software, or installing Microsoft service packs. This IQ tool checks LabChip GxP Software registry settings, the directory structure, and the integrity of each file specified for the software application. Operation Qualification The Caliper LabChip GxP Software contains OQ tool specifically designed to automate the operation qualification process. As shown in Figure 3, the left pane of the Instrument Diagnostics graphical user interface (GUI) lists each instrument component subject to OQ testing. Users have options to select or deselect items for testing to tailor their needs. Figure 3. Automated OQ Tool 3

The user works interactively with the GxP OQ tool. Once the testing gets started by clicking the Run Tests button, the software guides the user through the process by providing detailed instructions for the user to follow and the options that the user can choose. For example, in the step of checking the chip cartridge interlock, a dialog box pops up asking the user to unload the chip in order to proceed (see Figure 4.) Figure 4. User Friendly OQ Testing Guide Once each test item is completed, the test result is listed on the right pane of the OQ GUI. At the end of the OQ process, the test report is generated and saved to a file for review, printing, and documentation purpose. Performance Qualification Caliper field services are available to customers for their performance qualification needs. This service will be variable by customer need, and will be quoted on an individual basis. Depending on the type of application, for example, quality control (QC) testing for RNA, DNA or protein, users may want to establish application specific performance qualification and monitoring procedures. Caliper application scientists and consultants are available to assist the design of performance qualification procedures that are specific to the user applications. 21 CFR Part 11 Compliance Caliper LabChip GX/GXII instruments with LabChip GxP Software are computerized systems designed to automate the analysis of DNA, RNA or proteins using Caliper Sipper Chip technologies. The systems allow the users to create, modify, and maintain the records in electronic form and allow the users to perform electronic signatures on the records generated from the system. It takes a combination of administrative controls, procedural controls, and technical controls for the users of a computerized system to comply with 21 CFR Part 11 regulations. The LabChip GxP Software contains built-in technical controls and features specifically designed to support the users for 21 CFR Part 11 compliance. These technical controls and features include user account management and access controls, device check, enforcing permitted sequencing of steps, audit trails, record copying, record retention, system documentation, and electronic signature controls. 4

User Account Management and Access Controls A Caliper LabChip GX/GXII instrument with LabChip GxP Software is a closed system (21 CFR 11.10). The system can be located in a designated laboratory room to limit system access to authorized individuals (21 CFR 11.10(d)). The software contains an application security module for user account management and for access of controls to meet the requirement of 21 CFR 11.10(g). As shown in Figure 5, the system administrator can do the following: Manage user accounts Define access Set policies Figure 5. User Administration Only valid users are permitted to log on the system. Depending on the role of each user, a user can be assigned to one of the following four user groups: Restricted User Operator Supervisor Administrator The system has a set of predefined permissions allowing the system administrator to enable or disable for each group as shown in Figure 6. The assess settings can be printed out for documentation purpose. Figure 6. Role Access Control 5

LabChip GxP Software uses a user authentication and role-based access control mechanism for authority checks to ensure that only authorized individuals can use the system, perform the operation at hand, electronically sign a record, or alter a record (21 CFR 11.10(g)). Each user ID (identification) is unique (21 CFR 11.300(a)). As shown in Figure 7, the system administrator can set the password and login policies to prevent password aging (21 CFR 11.300(b)), and to limit the attempts of unauthorized use of the system (21 CFR 11.300(d)). After the limited number of failed login attempts, the account is locked out and only the administrator can unlock the account. Figure 7. Policies Setting The system has automatic lock feature to prevent the unauthorized access to the unattended system that is running. Similar to password protected screen saver application, after logging on and idle for specified time limit, the system allows the jobs to continue running in the background while it does not allow users access any functions without logging again on with valid password. Device Check Each Caliper LabChip GX/GXII instrument has a unique serial number to identify the specific instrument. After the system is validated and approved for GxP use, the user can enter the serial number into the system to enforce the device check (21 CFR 11.10(h)). Before starting each run, the system software automatically checks the device serial number to ensure the validity of the source of the data input. The device serial number is tied to the result of each run as part of the records. Enforcing Permitted Sequencing of Steps LabChip GX/GXII Systems allow users to run DNA, RNA, or protein assays. Each assay has its own sequencing of steps by design, which is automatically enforced by the system software (21 CFR 11.10(f)). 6

Audit Trails LabChip GXP Software uses secured, computergenerated, time-stamped audit trails to independently record the date and time of operator entries and actions that create, modify, or delete electronic records as shown in Figure 9. The audit trails can be printed out for documentation purpose. The audit trail documents can be made available for agency review and copying (21 CFR 11.10(e)). Figure 9. Audit Trails The system uses versioning mechanism so that record changes do not obscure previously recorded information. The users can always retrieve the previously recorded information by selecting a corresponding version of the records. To facilitate the review of audit trails, the user can customize the audit trails view and can search the audit trails based on date range, username, or file name (see Figure 10). Copies of Records Figure 10. Audit Trail Manage Views LabChip GxP Software has the ability to generate accurate and complete copies of records in both human readable (electronic display or printout) and electronic form suitable for inspection, review, and copying by regulatory inspector. These records include run results, assay settings, signatures, and audit trails. These records can be printed on paper or exported to ASCII files. The exported records are clearly marked as uncontrolled records. 7

Record Retention In addition to record printing function to support users meeting record retention requirements set forth in 21 CFR 11.10(c) in paper form, LabChip GxP Software allows user to store and retrieve the records in electronic form via backup/restore mechanism. During the installation of the LabChip GxP Software, the user has options to select CDR (Caliper Data Repository) on a network drive for backup purpose. The CDR Setup Utility enables the user to manage the CDR as shown in Figure 11. Figure 11. CDR Setup Utility System Documentation Caliper provides version controlled documentation for system operation and maintenance that is consistent with the released system. The built-in IQ tool automatically checks if the correct version of online document is installed. Electronic Signature LabChip GxP Software uses unique combination of user ID and password for users to sign records electronically (21 CFR 11.100(a)). As shown in Figure 12, each signature contains the following information (21 CFR 11.50(a)): The printed name of the signer; The date and time when the signature was executed; and The meaning associated with the signature. Figure 12. Perform Signature The signature is linked to the record undersigned (21 CFR 11.70), is subject to the same controls as for electronic records, and is included as part of electronic display or printout of the electronic record (21 CFR 11.50(b)). Caliper Life Sciences Hopkinton, MA 01748-1668 TEL: (508) 435-9500 FAX: (508) 435-3439 Web: www.caliperls.com 2010 Caliper Life Sciences Corporation. All rights reserved. Caliper, the Caliper logo and LabChip are registered trademarks of Caliper Life Sciences Corporation. All other trademarks contained herein are the property of their respective owners. 8 LCGX-MS-01