Keysight Technologies N9320B RF Spectrum Analyzer



Similar documents
Keysight N9320B RF Spectrum Analyzer

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Agilent E4401B, E4402B, E4404B, E4405B, and E4407B ESA-E Series Spectrum Analyzers

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

Keysight Technologies ESA-E Series Spectrum Analyzer

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note

khz to 2.7 GHz Spectrum Analyzer

R&S ZNC Vector Network Analyzer Specifications

Make Better RMS Measurements with Your DMM

Agilent N9342C Handheld Spectrum Analyzer (HSA)

Agilent E5063A ENA Series Network Analyzer

R&S ZNBT8 Vector Network Analyzer Specifications

HP 8590 E-Series Portable Spectrum Analyzers Technical Specifications

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent 87421A/87422A Power Supply

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

R&S ZVL Vector Network Analyzer Specifications

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits

R&S ZVA Vector Network Analyzer Specifications

Agilent 4338B Milliohm Meter

Agilent E5100A Network Analyzer

A Guide to Calibrating Your Spectrum Analyzer

Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance

Evaluating Oscilloscope Bandwidths for Your Application

Agilent 4339B/4349B High Resistance Meters

Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note

Keysight N9000A CXA Signal Analyzer

Agilent U2000 Series USB Power Sensors

NI USB-5681 RF Power Meter Specifications

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

802.11ac Power Measurement and Timing Analysis

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Keysight N6854A Geolocation System. Configuration Guide

R&S SMZ Frequency Multiplier Specifications

Agilent U2000 Series USB Power Sensors

Agilent E6832A W-CDMA Calibration Application

Handheld Spectrum Analyzer

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz

Impedance 50 (75 connectors via adapters)

AM/FM/ϕM Measurement Demodulator FS-K7

Ideal for high dynamic range measurements from compression to noise floor

Agilent P940xA/C Solid State PIN Diode Switches

The Next Generation in Automated Oscilloscope Test

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

1.5 GHz Active Probe TAP1500 Datasheet

Keysight Technologies AC6800 Series Basic AC Power Sources. Data Sheet

R&S ZCxxx Millimeter-Wave Converters Specifications

Keysight N9340B Handheld Spectrum Analyzer (HSA)

Agilent E5061B Network Analyzer 5 Hz to 3 GHz. Data Sheet

Variable Frequency Drive Troubleshooting with U1610A/U1620A

Agilent ENA-L RF Network Analyzers

HP 70950B OPTICAL SPECTRUM ANALYZER

Measurement, analysis, and monitoring of RF signals

Arbitrary/Function Generators AFG3000C Series Datasheet

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes

Agilent. E5071C ENA Network Analyzer. E5092A Configurable Multiport Test Set. Data Sheet

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Keysight Technologies M9393A PXIe Performance Vector Signal Analyzer. Data Sheet

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

Keysight E5063A ENA Series PCB Analyzer

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

Handheld Spectrum Analyzers, 3.3 GHz & 8.5 GHz Models 2650A, 2652A, 2658A

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

iva Cable & Antenna Analyzer

MATRIX TECHNICAL NOTES

Keysight Technologies M9514A and M9521A AXIe 14-Slot Chassis and AXIe System Module

Avionics. IFR 4000 Nav/Comm Test Set

HDO700 P FIBRE OPTIC TRANSMITTER

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Agilent Compatibility of USB Power Sensors with Agilent Instruments. Application Note

Real-Time Spectrum Analysis for Troubleshooting n/ac WLAN Devices

TekSmartLab TBX3000A, TSL3000B Datasheet

DDR Memory Overview, Development Cycle, and Challenges

FFT Spectrum Analyzers

E5092A Configurable Multiport Test Set

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

Multi-Range Programmable DC Power Supplies 9115 Series

One Port Network Analyzer

Transcription:

Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet

Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has been turned on at least 30 minutes It has been stored at an ambient temperature within the allowed operating range for at least two hours before being turned on; if it has been stored previously at a temperature range inside the allowed storage range, but outside the allowed operating range Specifications describe the performance of parameters covered by the product warranty and apply to the full temperature range of 5 to 45 C, unless otherwise noted. Typical values describe additional product performance information that is not covered by the product warranty. It is performance beyond specifications that 80 percent of the units exhibit with a 95 percent confidence level over the temperature range 20 to 30 C. Typical performance does not include measurement uncertainty. Nominal values indicate expected performance, or describe product performance that is useful in the application of the product, but are not covered by the product warranty. 2

Frequency and Time Specification Frequency Range 9 khz to 3 GHz AC coupled Resolution Internal 10 MHz frequency reference Aging rate 100 khz to 3 GHz Preamp on 1 Hz ± 1 ppm/year Temperature stability ± 1 ppm 5 to +45 C, reference 25 C Supply voltage stability ± 0.3 ppm Residual FM 100 Hz p-p in 100 ms nominal RBW = 1 khz, VBW = 1 khz Frequency readout accuracy (start, stop, center, marker) Marker resolution (freq span)/(number of sweep point -1) Uncertainty ± (freq indication x freq reference uncertainty 1 + 1% x span + 20% x resolution bandwidth + marker resolution) Sweep point Marker frequency counter 461, fixed Resolution 1 Hz, 10 Hz, 100 Hz, 1 khz Selectable Frequency span (FFT and swept mode) Range Resolution ± [(marker freq x freq reference uncertainty 1 ) + (counter resolution)] 0 Hz (zero span), 100 Hz to 3.0 GHz 1 Hz ± span/(swept points -1) Sweep time and triggering Span range 10 ms to 1000 s Span > 0 Hz Mode Trigger 6 μs to 200 s Span = 0 Hz (minimum resolution = 6 μs) Continuous, single Free run, video, external Trigger slope Positive or negative edge Selectable Trigger delay Resolution bandwidth (RBW) Range (-3 db bandwidth) Resolution filter shape factor 0 to 80 sweep time 10 Hz to 1 MHz, in 1-3-10 sequence ± 5% nominal < 5:1 nominal Range (-6 db bandwidth) 200 Hz, 9 khz, 120 khz, 1 MHz EMI bandwidth (CISPR 16-1-1 complaint), requires Option EMF ± 10% nominal Resolution filter shape factor < 5:1 nominal -60 db/-6 db bandwidth ratio Video bandwidth (VBW) Range 1 Hz to 1 MHz in 1-3-10 sequence -3 db bandwidth 1. Frequency reference uncertainty = Aging rate x period since adjustment + supply voltage stability + temperature stability. 3

Amplitude Specifications Amplitude range Measurement range (PA OFF) Input attenuator range Maximum damage level 10 MHz to 3 GHz: Displayed average noise level (DANL) to +30 dbm 1 to 10 MHz: DANL up to 23 dbm 100 khz to 1 MHz: DANL up to 20 dbm 0 to 70 db, in 1 db steps Average continuous power +37 dbm Input attenuator setting 10 db, 3 minutes maximum Peak pulse power +50 dbm (100 W) For < 10 μs pulse width, < 1% duty cycle, and input attenuation 40 db DC voltage Level display range Log scale units Linear scale units 50 VDC maximum dbm, dbmv, dbμv, dbμa μv, mv, V, μa, ma, A, μw, mw, W Marker level readout 0.01 db Log scale Resolution 0.01% of reference level Linear scale Number of traces 4 Detectors Trace function Frequency response 10 db input attenuation, reference: 50 MHz, 20 to -30 C Positive-peak, negative-peak, sample, normal, RMS Clear/write, maximum hold, average, minimum hold, view 200 khz to 2.0 GHz ± 0.5 db Preamp off 2.0 to 3.0 GHz ± 0.7 db Preamp off 1 MHz to 2.0 GHz ± 0.6 db Preamp on 2.0 to 3.0 GHz ± 0.8 db Preamp on Input attenuation switching uncertainty at 50 MHz Attenuation > 2 db, preamp off 0 to 60 db attenuation ± 0.4 db Relative to 10 db (reference setting) Absolute amplitude accuracy Center frequency 50 MHz, RBW 1 khz, VBW 1 khz, amplitude scale log, span 100 khz, sweep time coupled, peak detector, signal at reference level Preamp off ± 0.3 db Reference level -10 db, input attenuation 10 db Preamp on ± 0.4 db Reference level -30 db, input attenuation 10 db 4

Amplitude Specifications (continued) Level measurement uncertainty 20 to -30 C; frequency > 1 MHz; signal input 0 to -50 dbm; reference level 0 to -50 dbm; input attenuation 20 db; RBW 1 khz, VBW 1 khz; after calibration; preamp off Overall amplitude accuracy Level display range Log scale units Linear scale and units Marker level readout ± 1.5 db ± 0.5 db, typical dbm, dbmv, dbμv, dbμa W, mw, μw, A, ma, μa, V, mv, μv 0.01 db Resolution 0.01% of reference level Log scale Number of traces 4 Linear scale Detectors Trace functions Preamplifier Frequency range Gain Positive-peak, negative-peak, sample, normal, RMS Clear/write, maximum hold, average, minimum hold, view 1 MHz to 3.0 GHz 18 db nominal 5

Dynamic Range Specifications 1 db gain compression Preamp off 50 MHz to 3.0 GHz > 0 dbm, typical; total power at input mixer Preamp on 50 MHz to 3.0 GHz > -20 dbm, typical; total power at the preamp Total power at the preamp = total power at the input (dbm) - input attenuation (db) Displayed average noise level (DANL) Input terminated, 0 db RF attenuation, RBW = 10 Hz, VBW = 1 Hz, sample detector Preamp off 9 to 100 khz < -90 dbm, nominal 100 khz to 1 MHz < -90 dbm 3 x (f/100 khz) db 1 to 10 MHz < -124 dbm 10 MHz to 3 GHz < -130 dbm + 3 x (f/1 GHz) db Preamp on 100 khz to 1 MHz < -108 dbm 3 x (f/100 khz) db Spurious response Preamp off, signal input -30 dbm, 0 db RF attenuation 1 to 10 MHz < -142 dbm 10 MHz to 3 GHz < -148 dbm + 3 x (f/1 GHz) db Second harmonic distortion 10 to 200 MHz +30 dbm Preamp off, signal input -30 dbm, 0 db RF attenuation 200 to 500 MHz +35 dbm 500 MHz to 3 GHz +43 dbm Third-order intermodulation (TOI) 300 MHz to 3 GHz +10 dbm; +13 dbm nominal 6

Dynamic Range Specifications (continued) Spurious response (continued) Input related spurious < -60 dbc -30 dbm signal at input mixer, 20 to 30 C Residual response (inherent) < -83 dbc Input terminated and 0 db RF attenuation, preamp off Phase noise Specification Typical Offset from CW signal 10 khz < -88 dbc/hz < -90 dbc/hz Fc = 1 GHz, RBW = 1 khz, VBW = 10 Hz, and sample detector, log average, average times > 40 Residual FM 100 khz < -100 dbc/hz < -102 dbc/hz 1 MHz < -110 dbc/hz < -112 dbc/hz 100 Hz peak-to-peak in 100 ms 1 khz RBW, 1 khz VBW Tracking Generator Specifications (Option TG3 required) Output frequency Range 100 khz to 3 GHz Settable to 9 khz Resolution Output power level Range Resolution 1 Hz -30 to 0 dbm 0.1 db Absolute accuracy ± 0.75 db 20 to 30 C, at 50 MHz with coupled source attenuator, referenced to -20 dbm Output flatness ± 3 db 100 khz to 10 MHz ± 2 db 10 MHz to 3 GHz VSWR < 1.5:1 300 khz to 3 GHz, input attenuator 12 db Connector and impedance Maximum safe reverse level N-type female, 50 Ω Average total power 30 dbm (1 W) AC coupled 0 VDC MAX 7

Modulation Analysis Specifications Demodulation Frequency range 10 MHz to 3 GHz Carrier power accuracy ± 2 db ± 1 db typical Input power -30 to +20 dbm Auto attenuation Carrier power displayed resolution AM measurement (included in Option AMA) Modulation rate 0.01 dbm 20 Hz to 100 khz 1 Hz, nominal Modulation rate < 1 khz Depth 5 to 95% FM measurement (included in Option AMA) Modulation rate < 0.1% modulation rate, nominal Modulation rate 1 khz ± 4% nominal 20 Hz to 200 khz 1 Hz, nominal Modulation rate < 1 khz Deviation ASK measurement (included in Option DMA) Symbol rate range < 0.1% modulation rate, nominal Modulation rate 1 khz 20 Hz to 400 khz ± 4% nominal 200 Hz to 100 khz Modulation depth/index range 10 to 90% Displayed resolution 0.1% FSK measurement (included in Option DMA) Symbol rate range FSK deviation range ± 4% of reading, nominal 1 to 100 kh 1 to 400 khz ± 4% nominal b 1 and b 4, b is the ratio of frequency deviation to symbol rate Displayed resolution 0.01 Hz 8

Inputs and Outputs Front panel RF input connector N-type female, 50 Ω VSWR < 1.5:1 300 khz to 3 GHz, input attenuator 10 db Calibration output Amplitude -10 dbm ± 0.3 db Frequency Connector and impedance 50 MHz Same as the frequency reference BNC-type female, 50 Ω Probe power Voltage/current +15 V, 150 ma maximum -12.6 V, 150 ma maximum RF output connector N-type female, 50 Ω Option TG3 installed USB interface (host) A plug, version 1.1 Rear panel 10 MHz reference output Output amplitude > 0 dbm Connector and impedance BNC-type female, 50 Ω 10 MHz reference input Input amplitude -5 to +10 dbm Frequency lock range Connector and impedance ± 5 ppm of specified external reference input frequency BNC-type female, 50 Ω External trigger input Input amplitude 5 V TTL level Connector and impedance BNC-type female, 10 kω VGA output VGA analog RGB 31.5 khz horizontal, 60 Hz vertical sync rates, non-interlaced LAN TCP/IP interface D-sub 15-pin female connector 640 x 480 screen resolution 10Base, RJ-45 connector USB interface (device) B plug, version 1.1 VGA compatible GPIB interface IEEE-488 bus connector Optional G01 installed 9

General Temperature range Operating +5 to +45 C Storage -20 to +70 C EMC Complies with European EMC Directive 2004/108/EC IEC/EN 61326-1 or IEC/EN 61326-2-1 CISPR Pub 11 group 1, class A AS/NZS CISPR 11:2004 ICES/NMB-001:2004 This ISM device complies with Canadian ICES-001 Safety Complies with European Low Voltage Directive 2006/95/EC IEC/EN 61010-1 2nd Edition Canada: CSA C22.2 No. 61010-1-04 USA: UL 61010-1 2nd Edition Audio noise Acoustic noise emission LpA < 70 db Operator position Normal position Per ISO 7779 Environmental stress Samples of this product have been type tested in accordance with the Keysight Technologies, Inc. Environmental Test Maunal and verified to be robust against the environmental stresses of storage, transportation, and end-use; those stresses include, but are not limited to, temperature, humidity, shock, vibration, altitude, and power line conditions. Test methods are aligned with IEC 60068-2 and levels are similar to MILPRF-28800F Class 3 Power requirements Voltage and frequency (nominal) 100 to 240 VAC, 50 to 60 Hz Auto ranging Power consumption Display < 65 W Resolution 640 x 480 Size Data storage Internal External 165.1 mm (6.5 in) diagonal (nominal) 16 MB nominal Supports USB 2.0 compatible memory devices 10

General (continued) Weight (without options) Net 8.4 kg (18 lbs) nominal Shipping 14.5 kg (32 lbs) nominal Dimensions Height 132.5 mm (5.2 in) 3U rack height Width 320 mm (12.6 in) Length 400 mm (15.7 in) Warranty The N9320B spectrum analyzer is supplied with a one-year warranty Calibration cycle The recommended calibration cycle is one year. Calibration services are available through Keysight Service Centers Related Literature Keysight N9320B RF Spectrum Analyzer, Brochure, literature number 5990-8118EN Keysight N9320B RF Spectrum Analyzer, Configuration Guide, literature number 5990-8120EN 11

12 Keysight N9320B RF Spectrum Analyzer - Data Sheet mykeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/threeyearwarranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/assuranceplans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada (877) 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States (800) 829 4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 6375 8100 Europe & Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 Ireland 1800 832700 Israel 1 809 343051 Italy 800 599100 Luxembourg +32 800 58580 Netherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom 0800 0260637 www.keysight.com/find/n9320b For other unlisted countries: www.keysight.com/find/contactus (BP-07-10-14) This information is subject to change without notice. Keysight Technologies, 2014 Published in USA, August 4, 2014 5990-8119EN www.keysight.com