STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp



Similar documents
STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Guidance for implant removal. Straumann Dental Implant System

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

Crown and Bridge Restorations. Straumann synocta Prosthetic System

Straumann Dental Implant System. Fax Order Form Collection.*

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

Edentulous patients. Straumann Dental Implant System

BASIC INFORMATION ON THE prosthetic procedures. Straumann Bone Level Implant Line

Company information for patients. More than Swiss precision. A better quality of life.

Cement-retained crowns and bridges with the solid abutment system. Straumann Solid Abutment Prosthetic System

More than a fixed rehabilitation.

Restorative Guidelines

NARROW DIAMETER implant

Straumann Bone Level Tapered Implant Peer-to-peer communication

procedures & products NOBELESTHETICS including Procera

Straumann Dental Implant System. Implant Selection Guide.

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

Procedures & Products. NobelEsthetics

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

ATLANTIS abutments as individual as your patients

Regular C/X Prosthetics. Prosthetics

priti crown Your patients deserve you

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

screw-retained crown using a PEEK temporary abutment

One Abutment - One Time

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Straumann Cares. Process guide

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

screw-retained single crowns using custom-cast abutments

Prosthodontist s Perspective

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

CATALOGUE DES IMPLANTS SUISSE 2014

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Abutment fracture in a bridge supported by natural teeth and implants

prosthetic technique manual

platform shifting Nobel Biocare is shifting gingival beauty to the next level

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

Titanium Base for CAD/CAM For single-tooth and bridge solutions

Care for your dental implants. Patient information on dental implant aftercare

How To Use A Cresco

Structur 3. Gloss without polishing. Structur 3. Composite material for the fabrication of

ADA Insurance Codes for Laboratory Procedures:

Renaissance of One-Piece Implants

Clinical Perspectives

Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS*

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Choose What Feels Right. Bridge vs. Dental Implant

Press Abutment Solutions

Final Result 1 year later. Patient Case 19. Preoperative: Main Complaint:

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

Simpl Implant Abutments with Atlantis CAD CAM Technology

Standard Internal Hex

More than an implant. A sense of trust. Straumann Dental Implant System

ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations

Basic information on the surgical and prosthetic procedures. Straumann PURE Ceramic Implant

Aesthetics meets CAD/CAM in the dental surgery

PATIENT INFORMATION. A new quality of life with dental implants.

páêçå~=aéåí~ä=`^al`^j=póëíéã qá_~ëé

páêçå~=aéåí~ä=`^al`^j=póëíéã på~åmçëí

Cementation and Sterilization Guidelines for Labs and Dentists. Lava. Zirconia for Implant Abutments. Cementation and Sterilization.

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR

What Dental Implants Can Do For You!

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

United States. Product Catalog 2015

Straumann. Time-tested

Encode Restorative System Procedure & Laboratory Manual

portion of the tooth such as 3/4 Crown, 7/8Crown.

The SATURN implant by Cortex Dental Industries

About DENTSPLY Implants

NobelActive. procedures and products

Procedures & Products Powered by Procera. All-on-4

While the prosthetic rehabilitation of

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

THE INFLUENCE OF COMPRESSIVE CYCLIC LOADING ON THE RETENTION OF CAST CROWN COPINGS CEMENTED TO IMPLANT ABUTMENTS

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

DLT 123 CROWN AND BRIDGE

State-of-the-art for your prostheses

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

How to Achieve Shade Harmony With Different Restorations

your talent. our technology. the perfect fit.

Dental Implant Restoration

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

Dental implants and Astra Tech

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Anterior crowns used in children

Transcription:

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS Straumann Temporary Abutments, VITA CAD-Temp

The ITI (International Team for Implantology) is academic partner of Institut Straumann AG in the areas of research and education.

ContentS Temporary abutments 1. Temporary abutment Wide Neck (WN) Polymer with titanium alloy inlay 2 1.1. Prosthetic procedure for temporary abutment WN 3 2. Temporary abutment Regular Crossfit (RC) Polymer with titanium alloy inlay 9 2.1. Prosthetic procedure for temporary abutment RC 10

1. Temporary Abutment WIDE NECK (WN) Polymer with titanium alloy inlay Intended use Individual soft tissue management for esthetic cases Screw- or cement-retained temporary crowns Cement-retained temporary bridges Characteristics Simple Polymer material allows for easy and quick chair-side modification Easy-to-achieve esthetics due to tooth-colored and modifiable polymer material Reliable Precise fit and high stability due to reinforcement with titanium alloy inlay Do not use for longer than 6 months. Place temporary restoration out of occlusion. The devices are provided non-sterile and are for single use only. The abutment must be secured against aspiration. The abutments can be processed with cleaning/disinfecting agents such as Ethanol, Tego Cid 2 %, Micro 10 + 4 %, Cidex OPA pure and Grotanat 2 %. The abutment can be steam-sterilized (121 C for 20 minutes). 2

1.1. PROSTHETIC PROCEDURE FOR TEMPORARY ABUTMENT WN Option A: Screw-retained temporary crown Step 1 Individualization - Removing material Individualize the temporary abutment on an analog according to the mouth situation. Fine-cut tungsten carbide tools are recommended for processing this polymer material. Insertion in master model Hand-tighten the temporary abutment in the implant/implant analog with the SCS screwdriver and temporarily seal the screw channel (e.g. with cotton). Modification of abutments How far to reduce the dimensions NNC NC RN WN RC Please refer to the graphics above for details on modification limits. The temporary abutment can be shortened horizontally with standard tools and techniques, but the width must not be reduced by more than 1 mm at the thickest part (NNC, NC) or further than the metal margin (RN, WN, RC). 3

Step 2 Option A: Fabricating the temporary restoration Direct veneering Directly add the veneering material in order to fabricate the temporary restoration. Step 2 Option B: Fabricating the temporary restoration Vacuum stents Create the temporary restoration according to standard techniques (e.g. vacuum stents). Before adding up any material or performing corrections with veneering material (i.e. VITA VM LC materials, refer to the manufacturer s instructions), the surface of the temporary restorations must be cleaned and wetted with modeling liquid. Clean abutment with a steam jet. 4

Step 3 Finishing Remove excess acrylic, reopen the screw channel and finish the temporary restoration. Restorations made from VITA CAD-Temp can be pre-polished with a suitable silicone polisher and a small goathair brush. Standard acrylic polishing agents that are also suitable for intraoral use are used for high luster polishing. Avoid creating excessive heat. Important: Careful polishing is absolutely necessary to achieve a perfect result and to avoid plaque accumulation and related negative effects on the shade. Use a polishing aid or implant analog to protect the implant configuration while polishing the temporary restoration. Step 4 Final insertion Clean and sterilize the polished temporary restoration (refer to the manufacturer s instructions of the veneering material). Place the temporary restoration on the implant and tighten the screw between 15 Ncm and 35 Ncm (depending on implant stability) using the SCS screwdriver along with the ratchet and the torque control device. 5

Option B: Cement-retained temporary crown Step 1 Individualization - Removing material Individualize the temporary abutment on an analog according to the mouth situation. Fine-cut tungsten carbide tools are recommended for processing this polymer material. Modification of abutments How far to reduce the dimensions NNC NC RN WN RC Please refer to the graphics above for details on modification limits. The temporary abutment can be shortened horizontally with standard tools and techniques, but the width must not be reduced by more than 1 mm at the thickest part (NNC, NC) or further than the metal margin (RN, WN, RC). 6

Step 2 Fabricating the cement-retained temporary single crown Use a standard procedure to fabricate the cement-retained single crown (e.g. grind out a prefabricated plastic tooth). Step 3 Final insertion Clean and sterilize the polished temporary abutment. Place the customized temporary abutment on the implant and tighten the screw between 15 Ncm and 35 Ncm (depending on implant stability) using the SCS screwdriver along with the ratchet and the torque control device. 7

Cover the screw head with absorbent cotton or guttapercha and seal the screw channel temporarily (e.g. with absorbent cotton). Step 4 Cementing the temporary single crown Coat the internal configuration of the crown with temporary cement and cement it on the temporary abutment. 8

2. Temporary Abutment regular crossfit (rc) Polymer with titanium alloy inlay Intended use Individual soft tissue management for esthetic cases Screw- or cement-retained temporary crowns Cement-retained temporary bridges Characteristics Simple Polymer material allows for easy and quick chair-side modification Easy-to-achieve esthetics due to tooth-colored and modifiable polymer material Reliable Precise fit and high stability due to reinforcement with titanium alloy inlay CrossFit Connection Do not use for longer than 6 months. Place temporary restoration out of occlusion. The devices are provided non-sterile and are for single use only. The abutment must be secured against aspiration. The abutments can be processed with cleaning/disinfecting agents such as Ethanol, Tego Cid 2 %, Micro 10 + 4 %, Cidex OPA pure and Grotanat 2 %. The abutment can be steam-sterilized (121 C for 20 minutes). 9

2.1. prosthetic procedure for temporary abutment RC Option A: Screw-retained temporary crown Step 1 Individualization - Removing material Individualize the temporary abutment on an analog according to the mouth situation. Fine-cut tungsten carbide tools are recommended for processing this polymer material. Insertion in master model Hand-tighten the temporary abutment in the implant/implant analog with the SCS screwdriver and temporarily seal the screw channel (e.g. with cotton). Modification of abutments How far to reduce the dimensions NNC NC RN WN RC Please refer to the graphics above for details on modification limits. The temporary abutment can be shortened horizontally with standard tools and techniques, but the width must not be reduced by more than 1 mm at the thickest part (NNC, NC) or further than the metal margin (RN, WN, RC). 10

Step 2 Option A: Fabricating the temporary restoration Direct veneering Directly add the veneering material in order to fabricate the temporary restoration. Step 2 Option B: Fabricating the temporary restoration Vacuum stents Create the temporary restoration according to standard techniques (e.g. vacuum stents). Before adding up any material or performing corrections with veneering material (i.e. VITA VM LC materials, refer to the manufacturer s instructions), the surface of the temporary restorations must be cleaned and wetted with modeling liquid. Clean abutment with a steam jet. 11

Step 3 Finishing Remove excess acrylic, reopen the screw channel and finish the temporary restoration. Restorations made from VITA CAD-Temp can be pre-polished with a suitable silicone polisher and a small goathair brush. Standard acrylic polishing agents that are also suitable for intraoral use are used for high luster polishing. Avoid creating excessive heat. Important: Careful polishing is absolutely necessary to achieve a perfect result and to avoid plaque accumulation and related negative effects on the shade. Use a polishing aid or implant analog to protect the implant configuration while polishing the temporary restoration. Step 4 Final insertion Clean and sterilize the polished temporary restoration (refer to the manufacturer s instructions of the veneering material). Place the temporary restoration on the implant and tighten the screw between 15 Ncm and 35 Ncm (depending on implant stability) using the SCS screwdriver along with the ratchet and the torque control device. 12

Option B: Cement-retained temporary crown Step 1 Individualization - Removing material Individualize the temporary abutment on an analog according to the mouth situation. Fine-cut tungsten carbide tools are recommended for processing this polymer material. Modification of abutments How far to reduce the dimensions NNC NC RN WN RC Please refer to the graphics above for details on modification limits. The temporary abutment can be shortened horizontally with standard tools and techniques, but the width must not be reduced by more than 1 mm at the thickest part (NNC, NC) or further than the metal margin (RN, WN, RC). 13

Step 2 Fabricating the cement-retained temporary single crown Use a standard procedure to fabricate the cement-retained single crown (e.g. grind out a prefabricated plastic tooth). Step 3 Final insertion Clean and sterilize the polished temporary abutment. Place the customized temporary abutment on the implant and tighten the screw between 15 Ncm and 35 Ncm (depending on implant stability) using the SCS screwdriver along with the ratchet and the torque control device. 14

Cover the screw head with absorbent cotton or guttapercha and seal the screw channel temporarily (e.g. with absorbent cotton). Step 4 Cementing the temporary single crown Coat the internal configuration of the crown with temporary cement and cement it on the temporary abutment. 15

16 notes

www.straumann.com International Headquarters Institut Straumann AG Peter Merian-Weg 12 CH-4002 Basel, Switzerland Phone +41 (0)61 965 11 11 Fax +41 (0)61 965 11 01 VITA VM LC and VITA CAD-Temp are registered trademarks of VITA Zahnfabrik H.Rauter GmbH & Co. KG. Institut Straumann AG, 2012. All rights reserved. Straumann and/or other trademarks and logos from Straumann mentioned herein are the trademarks or registered trademarks of Straumann Holding AG and/or its affiliates. All rights reserved. Straumann products are CE marked 08/12