WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE



Similar documents
A Guide to Protein Blotting

2. Cut 6 sheets of Whatman 3MM paper and 1 sheet of blotting membrane to the size of the gel, or slightly smaller.

Western Blotting. USA: UK & Europe: europe@ptglab.com China: service@ptglab.com.

Protein transfer from SDS-PAGE to nitrocellulose membrane using the Trans-Blot SD cell (Western).

WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3

Running protein gels and detection of proteins

Compromise Elsewhere Protocols. Western Blotting Methods ROCK 1 of 11

ECL Western Blotting Substrate INSTRUCTIONS FOR USE OF PRODUCTS W1001 AND W1015.

Western Blotting: Mini-gels

PROTOCOL 1850 Millrace Drive, Suite 3A Eugene, Oregon

Protocol for Western Blotting

Western Blot Analysis

Product name Company Cat # PowerPac Basic Power supply Bio Rad Mini Protean electrophoresis system Mini trans blot cell Bio Rad

Pure-IP Western Blot Detection Kit

STANDARD OPERATING PROCEDURE

SDS-PAGE Protocol Mutated from the SDS-PAGE protocol written by the Lord of the Flies

Western Blotting For Protein Analysis

SDS-PAGE. (June 23, 2005)

Western Blotting. Prepare samples:

AES Application Focus Blotting Page 1

Western Blot Protocol Protein isolation

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

Protocol #24 Western Blotting

APPLICATION FOCUS. Application Solutions for Western Blotting

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Protein immunoblotting

How To Perform A Western Blot

Immunoblotting (Western blotting)

Electrophoresis and Electroblotting of Proteins

THE His Tag Antibody, mab, Mouse

Classic Immunoprecipitation

Western BLoT Immuno Booster

Biology 309 Lab Notebook

Fast Semi-Dry Transfer System with Yrdimes

Anti-ATF6 α antibody, mouse monoclonal (1-7)

CHRISTIAN LAB WESTERN BLOT PROTOCOL

METHOD USED TO EXTRACT TOTAL MUSCLE PROTEIN FOR WESTERN BLOT USING TRIS-EDTA BUFFER*

Methionine Sulfoxide Immunoblotting Kit

Dot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences

About the Kits...2 Description 2 Components 2

Nitrotyrosine Western blot starter pack

WESTERN BLOT PROTOCOL FOR LICOR ODYSSEY SCANNER (HAKE S LAB)

Methods for Protein Analysis

Discontinuous native protein gel electrophoresis

Protein extraction from Tissues and Cultured Cells using Bioruptor Standard & Plus

Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a

Anti-V5 Antibody Anti-V5-HRP Antibody

Technical Manual No Update date

Troubleshooting Guide for DNA Electrophoresis

EZ-Run Protein Gel Solution. EZ-Run Protein Standards. EZ-Run Gel Staining Solution. Traditional SDS-Page Reagents. Protein Electrophoresis

Introduction...3. Western Blotting Procedure Transfer...4. Protocol for Semi-dry Transfer with PVDF Membrane... 4

Chromatin Immunoprecipitation (ChIP)

WESTERN BLOTTING - A BEGINNER S GUIDE

ChIP TROUBLESHOOTING TIPS

ab TripleStain IHC Kit: M&M&R on rodent tissue (DAB, DAB/Ni & AP/Red)

Definitive guide to western blot

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C

Approaches that can be used to study expression of specific proteins

Odyssey Imaging Systems

Section XIII: Protein Separation in Agarose Gels

Pharmaceutical Biotechnology. Recombinant DNA technology Western blotting and SDS-PAGE

Accelerated Electrophoresis with Faster Run Times and Increased Sample Throughput

To fax an order, use To order online: learn more.

Biochemistry Lab SDS PAGE and Western blot General Instructions

EZ-PAGE Electrophoresis System USER MANUAL

竞 争 性 分 析 Epitope Mapping 实 验 方 法

Chapter 3 Contd. Western blotting & SDS PAGE

SDS-PAGE and Western Blotting with the Odyssey Infrared Imaging System Entered by Kevin Janes Janes Lab Protocols 12/9/14

Western Blot Protocol (updated on 05/20/14)

The immune response Antibodies Antigens Epitopes (antigenic determinants) the part of a protein antigen recognized by an antibody Haptens small

Table of Contents

ab Hi-Fi cdna Synthesis Kit

Southern Blot Analysis (from Baker lab, university of Florida)

Recombinant Enterokinase Kits

Two-Dimensional Gel Electrophoresis (2-DGE)

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Ubiquitin Interact Kit

Chapter 2 Antibodies. Contents. Introduction

7 Electrophoresis. µ proportional to Q

Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA

An In-Gel Digestion Protocol

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit

Simoa HD-1 Analyzer Troubleshooting Guide. USER Sep 2014 Software Version 1.3 Beta

Easy, Precise, Reliable Gel Electrophoresis Markers. Blocking Buffers. Ordering Information. Ordering Information

Troubleshooting Polyacrylamide Gel Electrophoresis (PAGE)

Principles of Immunohistochemistry Queen s Laboratory For Molecular Pathology

Covalent Conjugation to Cytodiagnostics Carboxylated Gold Nanoparticles Tech Note #105

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Human Free Testosterone(F-TESTO) ELISA Kit

Mini-PROTEAN Precast Gels

BUFFERS and MEDIAS Coomassie Blue Staining Solution Coomassie blue Destaining Solution DMEM Normal Cell Culture Media

Fluorescein Isothiocyanate (FITC)- conjugated Antibodies

Lab 5: DNA Fingerprinting

HiPer Ion Exchange Chromatography Teaching Kit

Protein/Protein and Protein/RNA Co-Immunoprecipitations (Kenny Watkins and Alice Barkan, updated 12/09)

A Guide to Transfer and Detection Third Edition

Studying Protein-Protein Interactions via Blot Overlay or Far Western Blot

Protein Precipitation Protocols

Transcription:

WESTERN BLOTTING TIPS AND TROUBLESHOOTING GUIDE TIPS FOR SUCCESSFUL WESTERB BLOTS TROUBLESHOOTING GUIDE 1. Suboptimal protein transfer. This is the most common complaint with western blotting and could be due to many different problems listed below. a) Low quality membrane used for transfer. High quality PVDF membrane is the blotting membrane of choice as low molecular weight proteins are sometimes transferred through nitrocellulose membranes and therefore may be not visible on the blot. b) Improper Western transfer procedure. c) For semi-dry Western transfers make sure the filter paper is wet. d) SDS-PAGE gel incorrectly made and/or run. e) Use unstained gels for transfer, as stained proteins are transferred with lower efficiency. f) Improper sample preparation for gel loading. Proper migration depends on protein samples containing SDS, dithiothreitol (DTT) or 2-mercaptoethanol and must be heated prior to loading. Use prestained protein to monitor of the transfer. 2. Current is much higher than the expected start current. a) Transfer buffer too concentrated. Prepare fresh buffer or dilute concentrated solution. Important- Make sure Tris base was used and not Tris-HCl when transfer solution was made. 3. Power supply current reading on power supply is zero when swiched on. a) Connection to power supply is not complete. Check connections between lid of apparatus and the electrode assembly jacks. Check connections between lid of apparatus and power supply. b) Insufficient buffer level. Make sure the upper buffer chamber doesn t leak. Verify that the assembly was properly done. c) Ionic strength of the buffer is too high.

d) Power supply is operating at a current close to its limit. Use a power supply with higher limits. e) Broken electrode. Check wire electrodes to make sure they are not broken. f) Blown fuse on power supply. Check fuse and replace, if necessary. 3. Too many bands on a Western blot. a) Antibody is not specific for the protein of interest. Reduce primary antibody concentration. Reduce the amount of total protein loaded on gel. Use monospecific or antigen affinity purified antibodies. b) Proteolytic breakdown of the antigen. This is not uncommon, particularly if samples are stored for prolonged time or if proteins or membranes are fractionated after homogenization of the starting tissue. All additional bands are of lower apparent molecular mass than the full-length protein. Addition of protease inhibitors could help prevent this. c) Too much protein per lane or detection system too sensitive. Overloading of the gel is one of the most common reasons for "ghost bands". Immobilized proteins may provide a concentrated adsorbtive surface to which certain IgG may bind nonspecifically. Similarly, such nonspecific binding may be uncovered when highly sensitive detection systems such as enhanced chemoluminescence are employed. A dilution series of the starting material usually clarifies which of the signals are artefactual. d) Ineffecient blocking. A variety of different blocking agents are described in the literature including nonionic detergents and/or proteins. Change of the blocking conditions may remedy the problem. f) Concentration of antigen too low. The resolution of SDS-PAGE is limited. If the relative concentration of the antigen of interest is too low (less than 0.2% of total protein), it may be difficult to detect. Signal enhancement may then lead to the appearance of artificial bands. Enrichment of the antigen by fractionation or by immunoprecipitation should be considered. g) Non-specific binding of secondary antibody. Run a control with the secondary antibody alone (omit primary antibody). If bands develop choose an alternative Secondary Antibody. Use monospecific or antigen affinity purified antibodies. Add 0.1-0.5% Tween 20 to secondary Antibody Solution.Use 2% non-fat dry milk in Blotting Buffer as a starting point to dilute primary and secondary antibodies. Adjust antibody concentration up or down as needed. Increase number of washes. Increase NaCl concentration in Blotting Buffer used for antibody dilution and wash steps (recommended range 0.15M - 0.5M). h) Aggregation of analyte. Increase amount of DTT to ensure complete reducing of disulfide bonds (20-100mM DTT). Heat in boiling water bath 5-10 minutes before loading onto gel. Perform a brief centrifugation.

i) Degradation of Analyte. Minimize freeze/thaw cycles of sample. Add protease inhibitors to sample before storage. Make fresh samples. j) Contamination of reagents. Check buffers for particulate or bacterial contamination. Make fresh reagents. 4. No Bands Observed a) Insufficient antibody. Some antibodies have low affinity to the protein of interest. Increase antibody concentration (2-4 fold higher than recommended starting concentration). b) Antibody may have lost activity. Perform a Dot Blot. c) Insufficient protein. Increase the amount of total protein loaded on gel. Use a positive control (recombinant protein, cell line or treat cells to express analyte of interest). d) Poor transfer. Wet PVDF/Immobilon-P membrane in methanol or nitrocellulose membrane in transfer buffer before use. Ensure that there is good contact between PVDF or nitrocellulose membrane and gel. e) Incomplete transfer. Optimize transfer time. High MW protein may require more time for transfer. To ensure transfer is complete, stain the membrane with Ponceau S, Amido Black or India Ink. Use prestained MW marker to help optimize transfer. d) Over transfer. Reduce voltage or time of transfer for low molecular weight proteins (< 10 kda). e) Isoelectric point of protein of interest is >9. Use alternative buffer system with higher ph such as CAPS (ph 10.5). f) Incorrect secondary antibody used. Confirm host species and Ig type of primary antibody. g) Old antibody. If antibody is expired or past manufacturer warranty, purchase fresh antibody. h) Incorrect storage of antibodies. Follow manufacturer's recommended storage and avoid freeze/thaw cycles. i) Sodium Azide contamination. Make sure buffers do not contain Sodium Azide as this will quench HRP signal. j) Insufficient incubation time with primary antibody. Extend incubation time to overnight at 4 C. 5. Faint Bands (Weak Signal)

a) Low protein-antibody binding. Reduce the number of washes to minimum. Reduce NaCl concentration in Blotting Buffer used for wash steps (recommended range 0.15M - 0.5M). Reduce NaCl concentration in Antibody Solution (recommended range 0.15M - 0.5M). b) Insufficient antibody. Antibody may have low affinity to protein of interest. Increase antibody concentration (2-4 fold higher than recommended starting concentration). c) Insufficient protein Increase the amount of total protein loaded on gel d) Weak/Old ECL. Use new ECL reagents. f) Non-fat dry milk may mask some antigens. Decrease milk percentage in Block and Antibody Solutions or substitute with 3% BSA. 6. High Background a) Non-specific binding of primary antibody. Use monospecific or antigen affinity-purified antibodies. Block in 5% milk. Adjust the milk (2-5%) or NaCl (0.15-0.5M) concentrations of primary Antibody Solution. b) Decrease antibody concentration. Non-specific binding of secondary antibody Run a control with the secondary antibody alone (omit primary antibody). If bands develop choose an alternative Secondary Antibody. c) Insufficient blocking Start with 5% dry milk with 0.1%- 0.5% Tween 20, 0.15-0.5M NaCl in 25mM Tris (ph 7.4). Incubation time may be extended. Adjust milk concentration up or down as needed. Overnight blocking at 4 C may decrease blocking efficiency since detergents might not be effective at lower temperatures. Non-fat dry milk may contain target antigen. Substitute with 3% BSA. Non-fat dry milk contains endogenous biotin and is incompatible with avidin/streptavidin. Substitute with 3% BSA. Some IgY antibodies may recognize milk protein Substitute with 3% BSA. d) Insufficient wash. Increase number of washes. Increase Tween 20 concentration in Wash Buffer (0.1%-0.5%). e) Non-Specific Binding of Primary Antibody. Increase NaCl concentration in primary Antibody Solution and Blotting Buffer used for dilution of primary antibody and wash steps (recommended range 0.15M - 0.5M). f) Film overexposed. Reduce exposure time. If target signal is too strong wait 5-10 minutes and re-expose to film. 7. Diffuse Bands

a) Excessive protein on gel. Reduce amount of protein loaded 8. White Bands (ECL method) a) Excessive signal generated. Reduce antibody or protein concentration. Excessive antibody or protein can cause extremely high levels of localized signal (usually at a single band). This results in rapid, complete consumption of substrate at this point. Since there is no light production after the completion of this reaction, white bands are the result when exposed to film. 9. Patchy uneven spots all over the blot a) Contamination of reagents. Check buffers for particulate or bacterial contaminate. Make fresh reagents. b) Not enough solution during incubation or washing. Make sure membrane is fully immersed during washes and antibody incubations. c) Air bubble trapped in membrane. Gently remove any air bubbles. Especially during transfer. d) Uneven agitation during incubations. Ensure uniform agitation by placing on a rocker/shaker. e) Contaminated equipment. Make sure that the electrophoresis unit is properly washed. Protein or pieces of gel remaining on the unit may stick to the membrane. Wash membrane thoroughly. f) HRP aggregation. Filter conjugate to remove HRP aggregates. g) Long exposure. Reduce exposure time. Aldrin V. Gomes, NPB Department, University of California, Davis 2009