A series of technology briefs spanning Tyco Electronics product portfolio



Similar documents
Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

Power surges can also be generated by equipment in your facility such as:

Gas Discharge Tubes GTCX26-XXXM-R05 Series

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications

Gas Discharge Tubes GTCX38-XXXM-R10 Series

Telecommunication Line Protectors

Gas Discharge Tubes GTCX36-XXXM-R05 Series

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. Secondary Transient Protection for T1/E1 Line Cards

Technical Article MS-2443

Bourns Resistive Products

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

LC01-6. Low Capacitance TVS for High-Speed Telecommunication Systems. PROTECTION PRODUCTS Description. Features. Applications

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

AN-3 SEVEN KEY CONSIDERATIONS BEFORE YOU START YOUR SLIC OR FXS PHONE LINE INTERFACE DESIGN

How To Protect Your Equipment From Overvoltage

LC05-6. Dual Low Capacitance TVS Array for Telecom Line-Card Applications. PROTECTION PRODUCTS Description. Features. Mechanical Characteristics

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

TISP4600F3, TISP4700F3 OBSOLETE

Advanced Power Supply Topics

APPLICATION NOTE. Circuit Protection Considerations for USB Overcurrent Protection

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

Transient Overvoltage Protection

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

AN-2 TEN KEY CONSIDERATIONS BEFORE YOU START YOUR DAA OR FXO PHONE LINE INTERFACE DESIGN

Line Reactors and AC Drives

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Grounding Demystified

Protection ICs Insurance for Electronic Devices

Accurate, Re-Settable Electronic Circuit Breaker

Circuit Protection is Key in Maintaining Growth for The Internet of Things

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Arc Terminator Active Arc-Resistant Switchgear

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

PTC Thermistors. Application notes. Date: February 2012

What Is Regeneration?

Interfacing electrification and system reliability. Earthing of AC and DC railways 4,10,13

MTL Surge Technologies. Product Overview

How To Test A Sidactor Series For A Power Supply

DC/DC power modules basics

Charging what can be more simple? SAE J1772

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Specifying a Variable Frequency Drive s

SurgeShield. Section A: What is SurgeShield?

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Nexus Technology Review -- Exhibit A

CPS Y S K CPS Y S C

Transient and Lightning Protection for the Water Industries

TISP4500H3BJ Overvoltage Protector

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

Application Note 324 T1/E1 Network Interface Design

Electrical Resistance Resistance (R)

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

LC03-6R2G. Low Capacitance Surface Mount TVS for High-Speed Data Interfaces. SO-8 LOW CAPACITANCE VOLTAGE SUPPRESSOR 2 kw PEAK POWER 6 VOLTS

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

How To Understand The Electrical Power Supply Of A Power Supply System

Power Supplies 3. SDN-P DIN Rail Series

Electrical Safety Tester Verification

C650 and C850 Series TBU High-Speed Protectors

DSL03. Low capacitance TVS for high speed lines such as xdsl. Description. Features. Complies with the following standards

TISP9110LDM Overvoltage Protector

ACTP250J1BJ AC Transient Protector

Intersection Preassembled 19-inch Rack

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

Protect your home and family with Advanced Technology from Cutler-Hammer

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

Thermistor motor protection

White Paper: Electrical Ground Rules

Benefits and Potential Dangers of Using USB for Test & Measurement Applications. Benefits of Using USB for Test and Measurement

ADACSNET USB Control Module

Unified requirements for systems with voltages above 1 kv up to 15 kv

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

CATALOGUE SURGE PROTECTION LOW VOLTAGE

Three-phase monitoring relay CM-PFE

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Fundamentals of Power

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

A.V.R. R250. Installation and maintenance R250 0V E+ E- VOLT STAB FREQ. & L.A.M. CONFIG. 50Hz. 47.5Hz. 57Hz LAM 1 13% 2 25% OFF LAM OFF 9

Surgelogic Surge Protective Device (SPD)

Design Fundamentals Protecting Set Top Boxes from ESD and Cable Discharge Threats

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

Model UT33A: OPERATING MANUAL Table of Contents (1)

Analog signal converters CC-E I/I Current / current isolators

Gas Discharge Tube (GDT) Products CG5 and SL0902A Series. CG5 and SL0902A Series

Video Camera Installation Guide

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

GroundRod AC Substation Earthing Tutorial

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Surge Protection for Photovoltaic Systems

Transcription:

A series of technology briefs spanning Tyco Electronics product portfolio Coordinated Circuit Protection Schemes Help Prevent Overvoltage and Overcurrent Damage Through advances in materials science and broad applications expertise, the Raychem Circuit Protection business unit of Tyco Electronics has pioneered the development of polymeric positive temperature coefficient (PPTC) circuit protection devices for more than 25 years. In recent years, however, its research and development has focused on technologies that expand circuit protection capabilities and encompass a wider range of application solutions. One of the design challenges being closely followed is the need for coordinated circuit protection. Because overcurrent and overvoltage protection are often viewed as two unrelated elements of the circuit protection design process, protection strategies can result

in costly multi-component solutions, and synergies between protective devices can be overlooked. This article presents two examples of how coordinated protection helps designers enhance equipment reliability, reduce component count and meet critical safety agency requirements. Telecom Equipment Protection Developments The PolySwitch PPTC devices and SiBar thyristors that provide overvoltage and overcurrent protection for telecommunication and networking applications were initially introduced more than ten years ago to meet the growing demand for resettable overcurrent protection. Along with new metal oxide varistors (MOVs) and gas discharge tubes (GTDs), these components help designers meet the protection requirements of ITU, Telcordia, and UL. Telecommunications network equipment, including analog and digital linecards, DSL and ISDN modems, T1 equipment and Voice over IP (VoIP) equipment, must comply with regional safety agency standards. These standards mandate the use of overcurrent and overvoltage protection to help achieve safe and reliable equipment performance. Telecom network equipment is exposed to two types of electrical hazards. The first results from lightning strikes that may hit a network directly, or induce high-voltage spikes in a pair of telephone wires. These spikes can damage sensitive electronic equipment at either end of the network. Therefore, they must be shunted to ground with an overvoltage device. The other hazard results from induced AC power currents or direct AC power contact. If the voltage of an overcurrent event is below the breakover voltage of the overvoltage protection device, continuous current will flow to the equipment. On the other hand, when the voltage of the overcurrent fault is higher than the breakover voltage of the overvoltage protection device, the overvoltage device must be protected from prolonged exposure to high current. When this type of fault occurs, the resistance of an installed PPTC overcurrent protection device increases from its base resistance to a much higher resistance, typically by three or more orders of magnitude, effectively isolating the fault. The device then remains in its latched position until the fault is cleared and power to the circuit is removed at which time the PPTC device resets to a low impedance state so that normal telephone operation can resume. There are two categories of overvoltage circuit protection devices clamping and foldback, or crowbar, devices. Clamping devices, such as MOVs and diodes, allow voltages up to a designed clamping level to pass through to the load during operation. Foldback devices, such as gas discharge tubes and thyristor surge suppressors, operate as shunt devices in response to a surge that exceeds the breakover voltage.

When the voltage exceeds the breakover voltage the thyristor surge protection device folds back, creating a low-impedance path, effectively shorting out the overvoltage condition. The device will remain in this low-impedance state until the current through the device is decreased below its hold rating. After an overvoltage event has passed, the thyristor resets to its high-impedance state and allows for normal system operation. In addition to resettable functionality, thyristor foldback devices offer some advantages over clamping devices. For a given fault current, the power dissipated in a thyristor is smaller than a clamp device. This permits the use of a smaller-sized overvoltage device, and results in lower capacitance, a highly desirable attribute for high-speed communication equipment. Figure 1. Typical overcurrent/overvoltage circuit protection system for network equipment. Figure 1 shows a typical protection system employed by network equipment manufacturers to help comply with ITU-T K.20 requirements. The SiBar thyristors help protect the sensitive electronics from fast overvoltage events, including lightning transients. The line feed resistor serves the purpose of regulating the steady-state current to the telephone line. The PolySwitch devices provide current limiting that may be required during power contact events that have a voltage lower than the foldback voltage of the SiBar devices. Additionally, the base resistance of the PPTC device limits the current during events that exceed the foldback voltage of the SiBar device. When a PPTC device is installed in the circuit it provides two important benefits. First, it protects the line feed resistors from overheating, and second it helps limit sneak current. During AC sneak current events in the 200 ma to 1A range if there is no overcurrent protection these resistors do not fuse open, and typically they will overheat and damage the circuit board.

Due to their fast and accurate breakover voltage, new GDT devices are also used on main distribution frame (MDF) modules, high data-rate telecom applications (e.g. ADSL, VDSL), and surge protection on power lines. GDTs are placed in front of, and in parallel with, the sensitive equipment and act as a high impedance component. These devices do not influence the signal in normal operation. However, in the event of an overvoltage surge, such as a lightning strike, the GDT switches to a low impedance state and diverts the energy away from the sensitive equipment. Coordinating Protection for AC Mains Applications Electrical equipment can be exposed to risk from large voltage or power transients on the AC Mains inputs caused by lightning strikes or power station load-switching transients. IEC 61000-4-5 is the global standard for voltage and current test conditions for equipment connected to AC Mains. Equipment for AC Mains applications is tested for surge immunity using a combination wave having a voltage waveform with 1.2 s rise and 50 s fall times and a current waveform having 8 s rise and 20 s fall times for all installation classes. Different rise and fall times exist for some telecom and datacom applications, but all AC Mains applications are tested to this combination wave. Coordinating overcurrent and overvoltage protection at the AC Mains input can help designers comply with safety agency requirements and minimize component count and cost. Figure 2 illustrates how Raychem Circuit Protection s ROV series metal oxide varistor is used in combination with the LVR series of PolySwitch devices to improve equipment reliability in the harsh AC environment, and help fulfill the IEC-61000 test requirements. Figure 2. Coordinated overvoltage and overcurrent protection on AC Mains circuit. The ROV device's high current-handling and energy absorption capability, fast response and low cost make it suitable for overvoltage protection in power supplies, surge strips, control board transformers and electric motors. The LVR overcurrent protection device is also rated at 240 V AC, permitting maximum voltages of up to 265 V AC and can be installed with the ROV device in the AC Mains input lines.

Unlike a single-shot current fuse, the resettable LVR device helps protect against conditions where faults may cause a rise in temperature with only a slight increase in current draw. When installed on the primary side of the circuit, in proximity to potential heat-generating components such as magnetics, FETs, or power resistors, the LVR device helps provide both overcurrent and overtemperature protection with a single installed component. Conditions that might cause the ROV device to remain clamped and conducting current can eventually result in overtemperature failure of the ROV. If the board geometry allows, placing the LVR device adjacent to the ROV device can also help protect the ROV device in extended overload conditions by transferring heat to the LVR device and causing it to trip more quickly. While not directly applicable to passing IEC 61000-4- 5 tests, placing the LVR device in close thermal proximity to the ROV device can cause the LVR device to trip faster, limit the current through the ROV and help protect it in continuous overload conditions. Any remote sensor, indicator, or actuator that requires an AC power, analog interface, or communications bus interface can also benefit from the use of coordinated circuit protection. These system components are subject to damage caused by miswiring, power cross or loose neutral connections on AC Mains inputs. An example of how coordinated overvoltage/overcurrent protection can be used with individual power, signal or communications interfaces is presented in Figure 3. Each PPTC device is combined with an overvoltage protection device, such as an ROV device, to help protect against overvoltage transients in addition to overcurrent faults. This circuit topology can be used to help equipment meet the UL requirements for Class 2 products, as well as IEC61000-4-5 surge immunity requirements.

Figure 3. Coordinated overvoltage/overcurrent design helps protect the interfaces between controllers and remote devices as well as power inputs. Summary PPTC devices provide resettable functionality, small size and low resistance, and are used worldwide as overcurrent protection elements in a wide range of telecom and AC Mains equipment applications. Thyristors, GDTs and MOVs are designed to help manufacturers meet ITU and Telcordia lightning surge and overvoltage protection requirements. Their key advantages are small form factor, low on-state power dissipation, and accurate voltage clamping or shunting. Their low capacitance also allows them to be used on high data rate circuits. Coordinated overvoltage/overcurrent circuit protection can help designers reduce component count, provide a safe and reliable product, comply with regulatory agency requirements and reduce warranty and repair costs. For additional technical information, contact your local Tyco Electronics Sales Engineer, or visit http://www.circuitprotection.com.