MagneW 3000 PLUS Flowmeter for Open Channel



Similar documents
Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Configuring the HydroRanger 200 to measure open channel flow. Specific parameter setting to configure the following primary measurement devices:

Flow Like An Egyptian: The Basics of Open channel flow

Open channel & partially filled pipe Ultrasonic flow meters

Tracking the Flow: Meeting the Challenge of Open- Channel Flow Measurement in Municipal Applications

Flow Measurement Calibration and Measurement

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

6. FLOW MEASUREMENT. A. Evaluation of Permittee's Flow Measurement

Mobrey open channel flow measurement systems

PART E WATER AND WASTEWATER SAMPLING. Her Majesty the Queen in Right of the Province of British Columbia 2003 All Rights Reserved

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

MONITORING AND MODEL CALIBRATION FOR THE SEWER NETWORK IN OSLO

Module 9: Basics of Pumps and Hydraulics Instructor Guide

How To Use A Flowmeter

Istat experience on surveying water statistics: the Water Survey System questionnaires

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

OPTIMASS 1400 Technical Datasheet

ELECTROMAGNETIC FLOWMETER COMPACT

QUESTIONNAIRE TO ASSIST PREPARATION FOR AN ISO AUDIT

Equipment for Engineering Education

Centre d expertise en analyse environnementale du Québec

Steven R. McManus Environmental Product Support Teledyne Isco

1 WATERFLUX - Comparisonon COO Rectangular Magmeter in water applications

Flow Measurement Options for Pipeline and Open Channel Flow

Open Channel Flow Measurement Weirs and Flumes

The World Market for Thermal Flowmeters

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

IFC 070 Technical Datasheet

HYDRAULICS. H91.8D/C - Computerized Open Surface Tilting Flow Channel - 10, 12.5, 15 and 20 m long

Electromagnetic Flow Meter

Mobrey open channel flow measurement systems

PACKAGE WASTEWATER TREATMENT PLANT SPECIFICATIONS 3,000 GPD 100,000 GPD PLANTS

CASE STUDY Hanjiang Dafu Shoe Company & Putian Hanjiang Shoe Company

Gertrudys B. Adkins, Ph.D. Division of Water Rights 2006

Core Fittings C-Core and CD-Core Fittings

...Eq(11.6) The energy loss in the jump is dependent on the two depths y 1 and y 2 3 = E =...Eq(11.7)

OPTIMASS 6000 Technical Datasheet

Minimum Requirements for the Self-Monitoring of Flow

FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Instrumentation for remote-monitoring and telemetry solutions in environmental sector: sensors - data loggers - web services

Flow Measurement. Larry Schwankl. Irriga0on Specialist, UC Coopera0ve Extension hep://ucanr.

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

Overview of the state of the art heat measurement technologies for larger solar thermal systems

PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY

The Japan Society of Mechanical Engineers C 2010

On Site Treatment Systems

Complete Solutions for On-Site Wastewater Management

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

How To Use A Corona Mdi 110

COMBIMASS. Technical Data COMBIMASS eco-bio +

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

SEPTIC SYSTEMS. 1. Building sewer connects the building plumbing to the septic tank.

On-site Treatmentt for Domestic Wastewater in Thailand Suwanna. K. Boontanon Mahidol Univ. 2

Training programme on flow measurements

GEC s Survey and Review on Water Footprint from Japanese Perspective

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

Understanding the Flo-Dar Flow Measuring System

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

ngenieros Ingenieros Asociados De Control S.L.

PRSENTATION ON DRAINAGE SYSTEM DELHI EAST DELHI MUNICIPAL CORPORATION

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

Urban Environmental Management in Singapore. Jothieswaran P Chief Engineer Pollution Control Department National Environment Agency

The Unique Accelabar Flow Meter

According to L. R. S. 48:385, any discharge to a state highway ditch, cross ditch, or right-of-way shall require approval from: AND

Sustainable solu&ons to wastewater systems in the face of sea level rise Chris&an Nilsen, PE Stanford University Research and Industrial Liaison

CHAPTER 15 MUNICIPAL SEPARATE STORM SEWER SYSTEM PROGRAM REQUIREMENTS

Series DFMT Digital Paddlewheel Flowmeter

Sewer servicing and integrated resource management

PORTABLE FLOW METER KITS TDS-100H

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE CHAPTER II SEWAGE AND WASTES SECTION 8

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

SILICON VALLEY CLEAN WATER. May 2015

CEE 370 Fall Laboratory #3 Open Channel Flow

ABB Flowmeters Review of industrial processing flowmeters

Know the Flow. Flowmetering Training Manual

Peeling the Onion of Meter Accuracy Two Steps to Evaluating Flow Meter Data

CHAPTER 10 TRAPS AND INTERCEPTORS

Practice Tests Answer Keys

Outline. Objective. Overview Sanitary Drainage System. Design. Materials

SDX Submersible Depth Transmitter User Manual

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

MAP KEYS GLOSSARY FOR THE DRAINAGE AND WATER REPORT

Reliability Accuracy Performance

FLOW CONDITIONER DESIGN FOR IMPROVING OPEN CHANNEL FLOW MEASUREMENT ACCURACY FROM A SONTEK ARGONAUT-SW

Type of Sewer Systems. Solomon Seyoum

Glen Hills Area: Septic System and Public Sewer Q & A Information Sheet Page 1

DigitalFlow GF868 Panametrics Ultrasonic Flare Gas Mass Flowmeter. GE Sensing. Features. Applications

2006 Standard Application Processing Time. 10 months. 14 months

City of Bakersfield Public Works Department Sewer System Management Plan December 2014

Repairs Made With Under Pressure Installations Can Offer Reduced Risks And Expenses

Mass Flow Meters & Controllers

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

Transcription:

MagneW 3000 PLUS Flowmeter for Open Channel Wastewater treatment application Yamatake Corporation October 2002 MagneW 3000 PLUS Open Channel type 1

Contents Environmental protection ISO 14000 Regulation for preventing Water Pollution (Japan, 1978) Total amount of wastewater restriction Monitoring total amount of wastewater Wastewater measurement Problems of wastewater flow measurement Yamatake Solution Field trial in Japan Exclusively certified by Japan Sewage Works Agency October 2002 MagneW 3000 PLUS Open Channel type 2

A. Environmental protection Environmental protection: World-wide tendency 1. ISO 14000 ISO 14000 requires ISO 14000 registered manufactures to implement Environment Management System to secure environment The following continuous activities are governed by ISO14000. 4.2 Policy, 4.3 Plan, 4.4 Do, 4.5 Check, 4.6 Action 4.2 : Requires to meet regulations for wastes. 4.5.1 Continuous monitoring: Need continuous monitoring of factors which may affect environment. October 2002 MagneW 3000 PLUS Open Channel type 3

A. Environmental protection Environmental protection: World-wide tendency 2. Regulation for Wastewater Regulation for preventing Water Pollution in Japan (1978) Total amount restriction Design Guidelines for Sewage Treatment Plants in Singapore issued by PUB (2000). ( Code of Practice on Sewerage and Sanitary Works, article 2.3.8) PUB: Public Utilities Board (Sewerage Department) c) Effluent limitations guidelines by EPA in the U.S.A. (2000) EPA: Environmental Protection Agency Restriction of Discharge of pollutants into waters d) Cluster rule (1998) Restriction of discharging pollutants for Pulp & Paper industry Restrict Wastes/pollutant October 2002 MagneW 3000 PLUS Open Channel type 4

B. Monitoring total amount of wastewater Environmental Protection requires restriction of pollutants in wastewater. Two factors to be controlled; 1. Quality of water (water analysis) 2. Total amount of wastewater Regulation Needs to monitor/control total amount of wastewater October 2002 MagneW 3000 PLUS Open Channel type 5

C. Wastewater measurement 1.Most of wastewater flows in open channel. 2.Weir or partial flume with level transmitter is mainly used for open channel flow measurement. October 2002 MagneW 3000 PLUS Open Channel type 6

D. Problems of wastewater flow measurement 1. Parshall flume flowmeter (with ultrasonic level transmitter) (1)Installation cost is expensive. (2)Low accuracy: +/- 2~5% FS Especially when flow rate is low. (3)Choppy wave causes error. (4)Output is not linear. (5)Minimum sensing flow rate:0.72m3/h October 2002 MagneW 3000 PLUS Open Channel type 7

D. Problems of wastewater flow measurement 2. Weir type flowmeter (with ultrasonic level transmitter) (1)Installation cost is not expensive. (2)Low accuracy: +/- 3~5% FS Especially when flow rate is low. (3)Choppy wave causes error. (4)Output is not linear. (5)Minimum sensing level: 5cm October 2002 MagneW 3000 PLUS Open Channel type 8

E. Yamatake solution Magnetic flowmeter for open channel (1)Installation cost is not expensive. (2)Higher accuracy: +/- 1% FS Accurate even though flow rate is low. (3)Choppy wave never causes error. (4)Output is linear. (From 0~100%) (5)Minimum sensing velocity: 0m/s 2Q Gate Detector Dummy October 2002 MagneW 3000 PLUS Open Channel type 9

E. Yamatake solution Magnetic flowmeter for open channel Additional features (1)Easy installation (2)Maintenance Free (3)Accurate large flow rate measurement 2Q Gate Detector Dummy October 2002 MagneW 3000 PLUS Open Channel type 10

E. Yamatake solution Magnetic flowmeter for open channel 1.Easy installation Offers lower installation cost. No piping is required. Installed in the open channel Installed at intake end of channel Installed in the pit Installed at discharge end channel Installed in the discharge tube Installed in the prefabrication sewage disposal plant October 2002 MagneW 3000 PLUS Open Channel type 11

E. Yamatake solution 2.Maintenance free (1)All welded plastic housing structure. = provides perfect seal. (2)The detector has no moving parts. Offers long life. 30 years. October 2002 MagneW 3000 PLUS Open Channel type 12

E. Yamatake solution 3.Accurate large flow rate measurement Installation of low cost dummies for increasing flow rate. NNK detector Dummy flowtube No coil unit and electrode Q 2Q 3Q Gate Gate Gate Detector Dummy Dummy: 9 units max. October 2002 MagneW 3000 PLUS Open Channel type 13

F. Field trial in Japan Comparison test with V-Notch weir flowmeter Field trial at Tagi Sewage Works in Shimane prefecture. Output was compared with the reference meter. Reference meter Reference meter V-Notch weir meter Yamatake Open channel type magflow meter NNK October 2002 MagneW 3000 PLUS Open Channel type 14

Test result F. Field trial in Japan Weir type flowmeter -50% error at low flow rate. Not sensitive at low flow rate. MagneW PLUS NNK Open channel type -1% error. Output from 0%. October 2002 MagneW 3000 PLUS Open Channel type 15

G. Exclusively certified products for wastewater treatment in Japan As a result of the field trial, Yamatake MagneW PLUS NNK is exclusively certified by Japan Sewage Works Agency. October 2002 MagneW 3000 PLUS Open Channel type 16