DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

Similar documents
ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement

DICOM 3.0 Conformance Statement

Version 8 DICOM Conformance Statement. Version 3.04, September 2014

MiPACS Storage Server Conformance Statement Version

HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T

Medflow Imaging DICOM Server

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, Copyright Brainlab AG

DICOM Conformance Statement CBS Images and Worklist Version 2.01

DICOM Conformance Statement FORUM

Infinity Medical Image Server

DICOM 3.0 Conformance Statement

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version DICOM Conformance Statement

DICOM Conformance Statement

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v Conformance Statement Direction number: Revision: 2

Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server

Dx MM DICOM 3.0 Conformance Statement

DigitizingStation. DICOM V3.0 Conformance Statement

DICOM Conformance Statement

DICOM 3.0 CONFORMANCE STATEMENT

DICOM Conformance Statement

Xeleris 2.0 Conformance Statement for DICOM V3.0

GE PACS Conformance Statement for DICOM v3.0

DICOM Conformance Statement Merge Eye Care PACS v. 4.0

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev B

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0

DICOM Conformance Statement. Version: 1.0

ClearCanvas ImageServer DICOM Conformance Statement

Technical Publications

Technical Publications

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0

Technical Publications

AGFA HEALTHCARE DICOM Conformance Statement

AGFA MEDICAL IMAGING DICOM Conformance Statement

Technical Publications

Philips Medical Systems DICOM Conformance Statement

GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0

Centricity TM RISi DICOM Conformance Statement

Varian System Server. DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement

Hologic Physician s Viewer 7.0 DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement. DICOMscope 3.5. Software developed by: M. Eichelberg 1, K. Kleber 2, J. Riesmeier 1, A. Schröter 2, A.

Technical Publications

DICOM Conformance Statement

Technical Publications

Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)

Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO Manufacturer:

DICOM Conformance Statement

DICOM. Conformance Statement. Envisor Software Version C.0

DICOM Conformance Statement

Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC

Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications

How To Write A Dicom Dicoma Dicomm Test Article

NETWORK MANAGEMENT FOR PICTURE ARCHIVING AND COMMUNICATION SYSTEMS

Table of Contents. Version History

How To Connect Ifa Dicom To An Ophthalmology System

SIGNA PROFILE CONFORMANCE STATEMENT

DICOM Conformance Statement

HDI 4000 Ultrasound System

ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0

DICOM Digital Imaging and Communications in Medicine

DICOM: Definitions and Testing

DICOM Conformance Statement. Veradius Unity

DICOM CONFORMANCE STATEMENT

PARCA Certified PACS Interface Analyst (CPIA) Requirements

DICOM Correction Proposal

OpenEMR: Achieving DICOM Interoperability using Mirth

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

Cenova Image Analytics Server DICOM Conformance Statement

Network Management for Picture Archiving and Communication Systems (PACS)

DICOM Conformance Statement. GDxPRO

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement

Workstation, Server Hosted

Digital Imaging and Communications in Medicine (DICOM) Part 1: Introduction and Overview

Understanding Digital Modalities: System Integration and Use

Medical Imaging in IDL

DICOM Conformance Statement

NEMA Standards Publication PS 3 Supplement 41. Digital Imaging and Communications in Medicine (DICOM) Digital Signatures

DICOM CONFORMANCE STATEMENT

QueryRetrieveSCU Queries image archives and controls remote retrieve of images to specified destination. (= SCU of Query/Retrieve SOP classes).

Implementation of DICOM Modality Worklist at Patient Registration Systems in Radiology Unit

A PACS-Aware DICOM Image Object

MedDream SendToPACS USER S MANUAL (version 1.15)

FUJIFILM MEDICAL SYSTEMS

510(k) Summary GlobalMedia Group, LIC. MAY CONiM

Medical Imaging in IDL

DICOM- an overview with an emphasis on Therapy

Extracting, Storing And Viewing The Data From Dicom Files

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC February 8, 2011

Transcription:

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

NOTICE The software described in this document has been validated in accordance with the governing DICOM standard at the time of this document's release. shall not be liable for errors contained herein or consequential damages in connection with the furnishing, performance, or use of this document. reserves the right to revise this publication and to make changes to its content at any time, without obligation to notify any person or entity of such revisions and changes. Copyright 2010 All Rights Reserved 9200 Eton Avenue Chatsworth, CA 91311 Phone: 818.435.1368 Fax: 818.435.1369 www.dolphinimaging.com DICOM Conformance Statement [Rev 1.0 03/2010] Page 2 of 14

CONTENTS Notice... 2 1. Introduction... 5 1.1. Overview... 5 1.2. Intended Audience... 5 1.3. Scope and Field of Application... 5 1.4. Important Remarks... 5 1.5. References... 5 1.6. Acronyms... 5 2. Implementation Model... 6 2.1. Application Data Flow Diagram... 6 2.2. Functional Definitions... 7 2.2.1. Query Database... 7 2.2.2. Transfer... 7 2.2.3. Send and Store... 8 2.2.4. Verify... 8 2.3. Sequencing of Real World Activities... 8 3. Dolphin Imaging AE Specifications... 9 3.1. Dolphin DICOM Imaging AE Specification... 9 3.1.1. Storage-Specification... 9 3.1.2. Query / Retrieve -Specification... 9 3.1.3. Verification -Specification... 10 3.1.4. Association Establishment Policies for dolphin DICOM Imaging AE... 10 3.1.5. Association Initiation Policies for dolphin DICOM Imaging AE... 10 3.1.6. Association Acceptance Policies for DOLPHIN DICOM Imaging AE... 12 4. Communication Profiles... 13 4.1. Supported Communication Stacks... 13 DICOM Conformance Statement [Rev 1.0 03/2010] Page 3 of 14

4.2 TCP/IP Stack... 13 4.3. Physical Media Support... 14 5. Configuration... 14 5.1. Configurable Settings... 14 DICOM Conformance Statement [Rev 1.0 03/2010] Page 4 of 14

1. INTRODUCTION 1.1. OVERVIEW This document is the DICOM Conformance Statement for Dolphin DICOM Imaging, the image acquisition component of the client-server software applications Dolphin Imaging from Dolphin Imaging & Management Solutions In its primary role, Dolphin DICOM Imaging will request access, storage, and retrieval of images from a DICOM 3.0 conformant server. 1.2. INTENDED AUDIENCE The reader of this document is concerned with software design and/or system integration issues. It is assumed that the reader of this document is familiar with the DICOM 3.0 Standard and the terminology and concepts employed in those documents. Readers wishing to obtain more familiarity with the content and terminology of DICOM 3.0 Standard are encouraged to obtain and review the standard prior to reading this Conformance Statement. More information on acquiring this document and its updates on the DICOM standard may be found on the website of the National Electrical Manufacturer's Association (NEMA) at http://www.nema.com. 1.3. SCOPE AND FIELD OF APPLICATION It is the intent of this document to describe the appropriate and decided communication of data between Dolphin DICOM Imaging and a DICOM 3.0 conformant server application. 1.4. IMPORTANT REMARKS The use of the Dolphin DICOM Imaging Conformance Statement, in conjunction with DICOM 3.0 Standard, is intended to facilitate communication between Dolphin software and other applications. These standards, by themselves, should not be the sole source for, or guarantee of, interoperability between Dolphin software and other non-dolphin applications or equipment. Responsibility for the correct design and integration of Dolphin software within the framework of other systems remains with the user and should not be minimized or overlooked. Users are strongly urged to test and validate the proper interaction between Dolphin Imaging and other non-dolphin applications or devices before declaring operability. 1.5. REFERENCES In preparing this conformance statement, frequent reference to the DICOM Standard, particularly PS 3.1 through PS 3.5, PS 3.7, PS 3.8, and PS 3.10 through PS 3.12 was made. 1.6. ACRONYMS The following acronyms appear in this document and are defined below. AE CT CUID DICOM MR NEMA Application Entity Computerized Tomography Class Unique Identifier Digital Imaging and Communications in Medicine Magnetic Resonance National Electrical Manufacturers' Association DICOM Conformance Statement [Rev 1.0 03/2010] Page 5 of 14

SCP SCU TCP/IP UID VL Service Class Provider Service Class User Transmission Control Protocol / Internet Protocol Unique Identifier Visible Light 2. IMPLEMENTATION MODEL 2.1. APPLICATION DATA FLOW DIAGRAM The Dolphin DICOM Imaging Application Entity (AE) is an application that initiates requests for the storage and retrieval of stored images and access to patient information. These requests originate with Dolphin DICOM Imaging which interfaces with the server by DICOM association. The implementation model of the Dolphin DICOM Imaging AE is shown in the following figure. Query Database Query Transfer Transfer DI Client Application Entity Send Store Verify Verify DICOM Association Receive DICOM Interface Figure 1. Implementation Model for Dolphin DICOM Imaging Application Entity DICOM Conformance Statement [Rev 1.0 03/2010] Page 6 of 14

2.2. FUNCTIONAL DEFINITIONS The Dolphin DICOM Imaging AE is an application initiating requests for image storage and retrieval from a DICOM 3.0 conformant server. Dolphin DICOM Imaging acts as a service class provider (SCP) in the following role: 1. SCP for C-Store operations to Storage service class users (during MOVE operations only) Dolphin DICOM Imaging acts as a service class user (SCU) in the following roles: 1. SCU of C-Store operations from Storage service class providers 2. SCU of C-Echo operations from Verification service class providers 3. SCU of C-Find operations from Query / Retrieve service class providers 4. SCU of C-Move operations from Query / Retrieve service class providers 2.2.1. QUERY DATABASE Dolphin DICOM Imaging can initiate a request (C-Find-RQ) for patient, study, and image queries. Dolphin DICOM Imaging provides in this request all the values for the attributes it wishes to match. Query Database Query/Retrieve SOP (DI Client SCU) C-Find- RQ C-Find-RSP Server Figure 2. Query Database Model DICOM Interface 2.2.2. TRANSFER IMAGE Dolphin DICOM Imaging can initiate an image move request (C-Move-RQ) and supplies unique values that identify the move destination to the server (AE name, IP address, and port number). Dolphin DICOM Imaging also receives a status message confirming the operation. Transfer Query/Retrieve SOP (Server SCP) C-Move-RQ C-Move-RSP DI Client (SCU) Send to Move Destination Transfer Store Storage SOP (Server SCU) C-Store-RQ C-Store-RSP DI Client (SCP) Receive Request to Move Receive DICOM Interface Figure 3. Transfer Model DICOM Conformance Statement [Rev 1.0 03/2010] Page 7 of 14

2.2.3. SEND AND STORE IMAGE Dolphin DICOM Imaging can initiate a request (C-Store-RQ) to store images it has acquired. Dolphin DICOM Imaging also receives a status message confirming the operation. Send/Store Storage SOP (DI Client SCU) C-Store-RQ C-Store-RSP Server DICOM Interface Figure 4. Send / Store Model 2.2.4. VERIFY Dolphin DICOM Imaging can initiate a request (C-Echo-RQ) to verify a current DICOM association. Verify Verification SOP (DI Client SCU) C-Echo-RQ C-Echo-RSP Server (SCP) DICOM Interface Figure 5. Verify Model 2.3. SEQUENCING OF REAL WORLD ACTIVITIES Not applicable Remainder of page intentionally left blank DICOM Conformance Statement [Rev 1.0 03/2010] Page 8 of 14

3. DOLPHIN IMAGING AE SPECIFICATIONS 3.1. DOLPHIN DICOM IMAGING AE SPECIFICATION 3.1.1. STORAGE-SPECIFICATION Dolphin DICOM Imaging provides Standard Conformance to the following DICOM 3.0 Standard SOP Class as a SCU. Table 1. Storage SOP Classes Supported by Dolphin DICOM Imaging SOP Class Name SOP Class UID Computed Radiography Storage 1.2.840.10008.5.1.4.1.1.1 CT Storage 1.2.840.10008.5.1.4.1.1.2 MR Storage 1.2.840.10008.5.1.4.1.1.4 Nuclear Medicine Storage 1.2.840.10008.5.1.4.1.1.20 Ultrasound Storage 1.2.840.10008.5.1.4.1.1.6.1 Ultrasound Multi Frame Storage 1.2.840.10008.5.1.4.1.1.3.1 X-ray Angiographic Storage 1.2.840.10008.5.1.4.1.1.12.1 X-ray Radiofluoroscopic Storage 1.2.840.10008.5.1.4.1.1.12.2 Positron Emission Tomography Storage 1.2.840.10008.5.1.4.1.1.128 Secondary Capture Storage 1.2.840.10008.5.1.4.1.1.7 Digital X-ray Storage for Presentation 1.2.840.10008.5.1.4.1.1.1.1 Digital X-ray Storage for Processing 1.2.840.10008.5.1.4.1.1.1.1.1 Digital Intra-oral X-ray Storage for Presentation 1.2.840.10008.5.1.4.1.1.1.3 Digital Intra-oral X-ray Storage for Processing 1.2.840.10008.5.1.4.1.1.1.3.1 Digital Mammography X-ray Storage for 1.2.840.10008.5.1.4.1.1.1.2 Presentation Digital Mammography X-ray Storage for Processing 1.2.840.10008.5.1.4.1.1.1.2.1 VL Endoscopic Storage 1.2.840.10008.5.1.4.1.1.77.1.1 VL Microscopic Storage 1.2.840.10008.5.1.4.1.1.77.1.2 VL Slide Coordinates Microscopic Storage 1.2.840.10008.5.1.4.1.1.77.1.3 VL Photographic Storage 1.2.840.10008.5.1.4.1.1.77.1.4 Patient Root Find 1.2.840.10008.5.1.4.1.2.1.1 Patient Root Move 1.2.840.10008.5.1.4.1.2.1.2 Study Root Find 1.2.840.10008.5.1.4.1.2.2.1 Study Root Move 1.2.840.10008.5.1.4.1.2.2.2 Patient Study Only Root Find 1.2.840.10008.5.1.4.1.2.3.1 Patient Study Only Root Move 1.2.840.10008.5.1.4.1.2.3.2 3.1.2. QUERY / RETRIEVE -SPECIFICATION Dolphin DICOM Imaging provides Standard Conformance to the following DICOM 3.0 Standard SOP Class as a SCU. Table 2. Query / Retrieve SOP Classes Supported by Dolphin DICOM Imaging SOP Class Name SOP Class ID Patient Root Find 1.2.840.10008.5.1.4.1.2.1.1 Patient Root Move 1.2.840.10008.5.1.4.1.2.1.2 Study Root Find 1.2.840.10008.5.1.4.1.2.2.1 Study Root Move 1.2.840.10008.5.1.4.1.2.2.2 Patient Study Only Root Find 1.2.840.10008.5.1.4.1.2.3.1 Patient Study Only Root Move 1.2.840.10008.5.1.4.1.2.3.2 DICOM Conformance Statement [Rev 1.0 03/2010] Page 9 of 14

3.1.3. VERIFICATION -SPECIFICATION Dolphin DICOM Imaging provides Standard Conformance to the following DICOM 3.0 Standard SOP Class as a SCU. Table 3. Verification SOP Class Supported by Dolphin DICOM Imaging SOP Class Name SOP Class ID Verification 1.2.840.10008.1.1 3.1.4. ASSOCIATION ESTABLISHMENT POLICIES FOR DOLPHIN DICOM IMAGING AE 3.1.4.1. GENERAL All associations with Dolphin DICOM Imaging are established using the DICOM 3.0 Standard application context. 1. Dolphin DICOM Imaging initiates an association for verification. 2. Dolphin DICOM Imaging initiates an association to query database. 3. Dolphin DICOM Imaging initiates an association to send and store images. 4. Dolphin DICOM Imaging initiates an association to transfer images. 5. Dolphin DICOM Imaging accepts an association to receive and store images transferred by the C-Move SCP 3.1.4.2. NUMBER OF ASSOCIATIONS Only one instance of Dolphin DICOM Imaging can be running at a time. Dolphin DICOM Imaging opens only one association. 3.1.4.3. ASYNCHRONOUS NATURE Not supported. 3.1.4.4. IMPLEMENTATION IDENTIFYING INFORMATION Dolphin s DICOM Imaging implementation provides a single Class Unique Identifier (CUID) of 1.2.840.114257.1123456 and a Version Name of 1. 3.1.5. ASSOCIATION INITIATION POLICIES FOR DOLPHIN DICOM IMAGING AE 3.1.5.1. Real World Activity: Request for Verification 3.1.5.1.1. ASSOCIATED REAL WORLD ACTIVITY Dolphin DICOM Imaging initiates an association with the server to verify the current DICOM association 3.1.5.1.2. PRESENTATION CONTEXTS Table 4. Presentation Contexts to Verify DICOM Association Abstract Syntax Transfer Syntax Extended Role Name UID Name UID Negotiation Verification 1.2.840.10008.1.1 Implicit VR Little Endian 1.2.840.10008.1.2 SCU None DICOM Conformance Statement [Rev 1.0 03/2010] Page 10 of 14

3.1.5.2. REAL WORLD ACTIVITY: REQUEST TO GET WORKLIST / QUERY DATABASE 3.1.5.2.1. ASSOCIATED REAL WORLD ACTIVITY Dolphin DICOM Imaging initiates an association with Server to get the patient worklist or to send query requests and to receive the appropriate C-Find status code. 3.1.5.2.2. PRESENTATION CONTEXTS Table 5. Presentation Contexts to Query Database Abstract Syntax Transfer Syntax Extended Role Name UID Name UID Negotiation Patient Root Query/Retrieve (Find) 1.2.840.10008.5.1.4.1.2.1.1 Implicit VR Little Endian 1.2.840.10008.1.2 SCU None Study Root Query/Retrieve (Find) Patient/Study Only Query/ Retrieve (Find) 1.2.840.10008.5.1.4.1.2.2.1 Implicit VR Little Endian 1.2.840.10008.5.1.4.1.2.3.1 Implicit VR Little Endian 1.2.840.10008.1.2 SCU None 1.2.840.10008.1.2 SCU None 3.1.5.3. READ WORLD ACTIVITY: REQUEST TO SEND AND STORE IMAGES 3.1.5.3.1. ASSOCIATED REAL WORLD ACTIVITY Dolphin DICOM Imaging initiates an association with the server to send and store images and to receive the appropriate C-Store status code. 3.1.5.3.2. PRESENTATION CONTEXTS Table 6. Presentation Contexts to Send and Store s Abstract Syntax Transfer Syntax Extended Role Name UID Name UID Negotiation Digital X-ray Storage (Presentation) 1.2.840.10008.5.1.4.1.1.1.1 Explicit VR Little Endian Uncompressed 1.2.840.10008.1.2.1 SCU None Digital Intraoral X-ray Storage (Presentation) 1.2.840.10008.5.1.4.1.1.1.3 Explicit VR Little Endian Uncompressed 1.2.840.10008.1.2.1 SCU None 3.1.5.4. REAL WORLD ACTIVITY: REQUEST TO TRANSFER IMAGES 3.1.5.4.1. ASSOCIATED REAL WORLD ACTIVITY Dolphin DICOM Imaging initiates an association with the server to transfer images and to issue the appropriate C- Move status code. DICOM Conformance Statement [Rev 1.0 03/2010] Page 11 of 14

3.1.5.4.2. PRESENTATION CONTEXTS Table 7. Presentation Contexts to Transfer s Abstract Syntax Transfer Syntax Extended Role Name UID Name UID Negotiation Patient Root Query/Retrieve (Move) 1.2.840.10008.5.1.4.1.2.1.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 SCU None Study Root Query/Retrieve (Move) Patient/Study Only Query/Retrieve (Move) 1.2.840.10008.5.1.4.1.2.2.2 Explicit VR Little Endian 1.2.840.10008.5.1.4.1.2.3.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 SCU None 1.2.840.10008.1.2.1 SCU None 3.1.6. ASSOCIATION ACCEPTANCE POLICIES FOR DOLPHIN DICOM IMAGING AE 3.1.6.1. REAL WORLD ACTIVITY: RESPOND TO STORE IMAGES REQUEST 3.1.6.1.1. ASSOCIATED REAL WORLD ACTIVITY Dolphin DICOM Imaging accepts an association to store images as a result of a C-Move request. 3.1.6.1.2. PRESENTATION CONTEXTS Table 8. Transfer Syntaxes to Store s Name UID Implicit VR Little Endian 1.2.840.10008.1.2 Explicit VR Little Endian 1.2.840.10008.1.2.1 Implicit VR Big Endian 1.2.840.10008.1.2.2 JPEG Baseline 1.2.840.10008.1.2.4.50 JPEG Extended 1.2.840.10008.1.2.4.51 JPEG 2000 Lossless 1.2.840.10008.1.2.4.90 JPEG 2000 1.2.840.10008.1.2.4.91 RLE Lossless 1.2.840.10008.1.2.5 Table 9: Presentation Contexts to Store s Abstract Syntax Extended Role Name UID Transfer Syntax Negotiation Computed Radiography 1.2.840.10008.5.1.4.1.1.1 All from Table 8 SCP None Storage CT Storage 1.2.840.10008.5.1.4.1.1.2 All from Table 8 SCP None MR Storage 1.2.840.10008.5.1.4.1.4 All from Table 8 SCP None Nuclear Medicine 1.2.840.10008.5.1.4.1.1.20 All from Table 8 SCP None Storage Ultrasound 1.2.840.10008.5.1.4.1.1.6.1 All from Table 8 SCP None Storage Ultrasound Multi- Frame Storage 1.2.840.10008.5.1.4.1.1.3.1 All from Table 8 SCP None DICOM Conformance Statement [Rev 1.0 03/2010] Page 12 of 14

X-ray Angiographic Storage X-ray Radiofluoroscopic Storage Positron Emission Tomography Storage Secondary Capture Storage Digital X-ray Storage (Presentation) Digital X-ray Storage (Processing) Digital Intra-oral X-ray Storage (Presentation) Digital Intra-oral X-ray Storage (Processing) Digital Mammography X- ray Storage (Presentation) Digital Mammography X- ray Storage (Processing) VL Endoscopic Storage VL Microscopic Storage VL Slide Coordinates Microscopic Storage VL Photographic Storage 1.2.840.10008.5.1.4.1.1.12.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.12.2 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.128 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.7 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.1.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.3 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.3.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.2 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.1.2.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.77.1.1 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.77.1.2 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.77.1.3 All from Table 8 SCP None 1.2.840.10008.5.1.4.1.1.77.1.4 All from Table 8 SCP None 4. COMMUNICATION PROFILES 4.1. SUPPORTED COMMUNICATION STACKS Dolphin DICOM Imaging provides TCP/IP Network Communication Support in accordance with DICOM 3.0 Standard. 4.2 TCP/IP STACK Dolphin DICOM Imaging communicates over the TCP/IP protocol stack on any physical interconnection supporting the TCP/IP stack. DICOM Conformance Statement [Rev 1.0 03/2010] Page 13 of 14

4.3. PHYSICAL MEDIA SUPPORT Dolphin DICOM Imaging is indifferent to the physical medium over which the TCP/IP executes. 5. CONFIGURATION 5.1. CONFIGURABLE SETTINGS The following settings are configurable at the Dolphin DICOM Imaging Configuration dialog box. 1. Remote IP Address 2. Remote Port Number 3. Remote Application Entity Title (Called AE) 4. Local Application Entity Title (Calling AE) 5. Local IP Address 6. Local Port Number Remainder of page intentionally left blank DICOM Conformance Statement [Rev 1.0 03/2010] Page 14 of 14