How To Make A Blood Bank



Similar documents
SJÖGREN S INTERNATIONAL COLLABORATIVE CLINICAL ALLIANCE (SICCA) BIOREPOSITORY AND DATA REGISTRY STORAGE OF BIOSPECIMENS

Best-Practice Guide Pharmaceutical-Chain Temperature Control and Recording

Off Site Sample Storage Specialists

INTRODUCTION. Viral shedding is crucial for Gene Therapy Products Safety linked with shedding data

Refrigeration Guidelines. Requirements for the Storage of Blood and Blood Products

HSE Guidelines for maintaining the vaccine cold-chain including maintenance of vaccine fridges and management of vaccines

New York State Department of Health (NYSDOH) Bureau of Immunization Vaccine Storage and Handling Plan

INMA LABORATORY MANUAL

Smart. Scalable. Simple.

Transport and Mailing Systems

MT I Transport Boxes (Active & Passive)

11 MEDICATION MANAGEMENT

Troubleshooting Your Refrigerator

VialSafe. DHL VialSafe. UN3373 Packaging Solutions

ArcticStore. product guide environmentally friendly storage solutions

OBJECTIVE: To provide safe storage and handling for vaccines and medications that require refrigeration.

Storage and Handling. Vaccine Storage and Handling. Storage and Handling Plans

Campus Services Hints and tips for residents

Transport Boxes (active & passive systems)

MANAGING BLOOD AND BLOOD PRODUCT INVENTORY

BIOMEDICAL REFRIGERATORS

S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers

Data Logger Basics For VFC Providers. Montana Immunization Program

BR I Blood Bank Refrigerators

Affordable wireless monitoring without compromise

14.0 Stem Cell Laboratory Services

Bauknecht AG, Industriestrasse 36, 5600 Lenzburg,

Single Zone LCD Thermostat Operating Instructions

Appendix 2: Example Validation Plan

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

1 Temperature Monitoring of Medication and Vaccine Fridges

Our Vector range is growing, so can your profit. Vector Vector 1850

The effect of cold chain on mushroom quality. Dr John Collier Monaghan Mushrooms

Cold Chain Shipping: Protecting Temperature Sensitive Products. Diane McLean Pfizer Global Manufacturing

PROCEDURE FOR FRESH APPLE AND PEAR EXPORTS FROM SOUTH AFRICA TO MEXICO. Responsibility: Service Manager: Special Shipments Name: Initial:

SECTION 7 STORAGE AND HANDLING OF IMMUNIZATION AGENTS

Red blood cell transfusions in the Netherlands Towards (very) low use

Reading Racked 2D-Coded Cryo Tubes directly from -80ºC Freezer

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Genesis II. revolutionise monitoring. Why Tutela Genesis II. delivering medical monitoring worldwide

What Should I Expect From My Alarm Monitoring Station?

Energy saving tips for home

Thermostatic Equipment

GUIDELINES FOR IMPLEMTING GMP IN FOOD PROCESSING

DEPARTMENT OF CLINICAL LABORATORY SCIENCES SCHOOL OF HEALTH TECHNOLOGY AND MANAGEMENT THE UNIVERSITY AT STONY BROOK STONY BROOK, NEW YORK

URINE COLLECTION, PREPARATION AND HANDLING

LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS

Operations Manual Blast Chiller

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Facility Name. Day of Month

BB-18 Black Body High Vacuum System Technical Description

Protocol for ordering, storing and handling vaccines. March 2014

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Things you need. Time ?????? Large pyrex beaker preferably 500 to 1000ml, or large steel vacuum

How to choose a heat pump and use it wisely

General Purpose Laboratory Freezer with Alarms

Frequently Asked Questions. Isotherm Fridge & Freezers

Food delivery & storage

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Blood Bank Refrigerators according to DIN Blood Plasma Freezers according to DIN 58375

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

VFC. Vaccine Management Guide. Vaccines for children. Chicago Department of Public Health

REQUIREMENTS FOR TRADE SHOWS

CHAPTER 5 SHIPPING PROCEDURES

Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

Monitoring manufacturing, production and storage environments in the pharmaceutical industry

Program Manual Policy & Practice Standards Manual

NIAGARA Niagara Blower Heat Transfer Solutions

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

ENERGY COSTS A LOT, DON T WASTE IT. Professer. O.Courant SAVE UP TO 15% ON YOUR MONTHLY ELECTRICITY BILL. Konn servi lénerzi, ou ki pou sorti gagnan

How to prepare your baby s bottle feed

Processing Cord Blood With the SynGenX System

Energy Efficiency. Bars & RestauRants.

DNA Ladders shipped at ambient temperature reduce environmental impact and retain their quality and stability

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Manual on the management, maintenance and use of blood cold chain equipment

IT in the Supermarket

Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER

This handbook is designed to help you through each step of owning your new appliance, from installation to use.

VACCINE CARRIERS AND COLD BOXES

RISK ASSESMENT: HANDLING, TRANSPORTATION AND STORAGE OF LIQUID NITROGEN AND OTHER CRYOGENIC MATERIAL

Daily Temperature Chart Instructions

Liquid Nitrogen from BOC Healthcare.

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

Freezers - Ultrafreezers. Platilab & Irilab Series

A Stability Program for the Distribution of Drug Products

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

Quality Assurance in Blood Cell Labelling

Preparing Food at Home advice and legal requirements

Family Cord Blood Stem Cells Bank

HARVESTING AND CRYOPRESERVATION OF HUMAN EMBRYONIC STEM CELLS (hescs)

Incubator with mechanical convection

(WHO Technical Report Series, No. 961, 2011), Annex 9. Temperature and humidity monitoring systems for fixed storage areas 107

Transcription:

Optimal management of the cold chain. Infosession BeQuinT June 5th, 2014 Jan Ceulemans, QA Manager, Belgian Red Cross Flanders Dominiek Vanaudenaerde, OPS Manager ProLog, Belgian Red Cross Flanders Rode Kruis

Optimal management of the cold chain What are the legal criteria? What is the cold chain? Monitoring the cold chain by state-of-the-art technology

Legal criteria Red cells must be kept at a controlled temperature between + 2 C to + 6 C Platelets : + 20 ºC to + 24 ºC under constant agitation. Fresh frozen human plasma, virus-inactivated : 12 months at below 25 C 3 months at 18 ºC to 25 ºC. Based on Belgian Legislation (KB April 4 th 1996) and the European Committee Guide to the Preparation, Use and Quality Assurance of Blood components (EDQM 2013)

Cold chain The cold chain is a temperature-controlled supply chain. An unbroken cold chain is an uninterrupted series of storage and distribution activities which maintain a given temperature range. All systems and processes that might impact the safety, efficacy or quality of the blood product must be validated, including storage and distribution.

Cold chain from vein to vein Collection Transport Processing Storage Distribution Keeping the cold chain unbroken by using state-of-the-art technology... some real-life examples

T-controlled container Collection Transport Processing Storage Distribution

T-controlled container In the past the temperature of the whole blood was controlled during the transport from collection to production with cooling plates, providing a rapid cooling of the blood, followed by a further storage at a stable temperature of 20 c. Problem with low ambient temperatures : Under its control point of 20 C the plate loses its temperature stabilizing effect. Problem with high temperatures (30 C)

T-controlled container Solution : robust, T-controlled container on wheels Sufficient and quick cooling, even at high ambient temperatures Protection against strong cooling at low ambient temperatures Stable temperature between 20 C and 22 C from collecting until the processing of the whole blood Great storage volume (KCL 120 : 120 full blood bags) Simpler transportation On board T-monitoring and T-alarm

T-controlled container

T-controlled container Power plug in during transport Validation and temperature mapping

T-controlled container

T-controlled container Smaller version : KCS 48 : 48 blood bags

T-loggers Collection Transport Processing Storage Distribution

T-loggers Temperatures of internal and external transports are monitored via T-loggers T-loggers also used for T-mapping and validation purposes (see later)

Nitrogen Quick Freezer Collection Transport Processing Storage Distribution

Nitrogen Quick Freezer Plasma collected from whole blood must be frozen within 18 hours and plasma collected by apheresis must be frozen within 12 hours. The core temperature of the plasma must be less than -30 C within 60 minutes. Solution : Nitrogen Quick Freezer The evaporation of the nitrogen creates a cold and dense mist which cools the plasma directly. Capacity of 300-350 bags per cycle of 1 hour

Nitrogen Quick Freezer

Nitrogen Quick Freezer

Central Monitoring System (CMS) Collection Transport Processing Storage Distribution

Central Monitoring System (CMS) 24/24 h electronic temperature monitoring of all critical rooms and equipment. Network-operated : can be consulted anywhere, anytime. In the event of netwerk outage : local data storage. Validated

Central Monitoring System (CMS)

Central Monitoring System (CMS) Two alert (pre-alarm) and two alarm levels Technical alarms : sensor broken, power loss, communication failure, Identifies location and device in case of T exceeding the maximum or minimum treshold. Central Red Cross dispatching unit forwards any alarm to the relevant person to follow-up. In addition to central dispatching : e-mail and text message Clear visualisation and reporting

Central Monitoring System (CMS) Cold Chain Central Monitoring System Central data storage

System Validation and T-mapping Collection Transport Processing Storage Distribution

System Validation and T-mapping Storage conditions for blood components are designed to preserve optimal viability and function during the whole storage period*. *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

System Validation and T-mapping Whatever type of storage device is chosen, the following points should be considered before purchase: refrigerators and freezers must have surplus capacity. The space should be easy to inspect; the operation must be reliable and temperature distribution must be uniform within the unit; the equipment must have temperature recording and alarm devices; the equipment should be easy to clean and should withstand strong detergents. It should also conform to local safety requirements.* *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

System Validation and T-mapping Storage at + 2 C to + 6 C* The space for each of the component types should be clearly indicated. The temperature within the unit should be recorded continuously. The sensor of the temperature monitoring device should be placed within a blood bag filled with antifrogen L solution to a volume of 250 ml or a volume equivalent to the normal volume of the stored component. The alarm system should preferably have both acoustic and optical signals and should be tested regularly. Refrigerators for blood components should ideally be connected to a back-up power unit as well as the main supply. *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

System Validation and T-mapping Storage at + 20 C to + 24 C* Platelets are stored at + 20 C to + 24 C. A closed device that permits temperature control is recommended. If such a device is unavailable, the space chosen should be capable of maintaining the required constant temperature. The platelets should be stored in agitators. *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

System Validation and T-mapping Storage of frozen plasma components* - 25 C Freezers with automatic defrosting should be avoided unless it can be guaranteed that the low temperature is maintained during defrosting. Freezers should ideally be connected to a back-up power unit as well as the main supply. *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

System Validation and T-mapping All equipment used to maintain the cold chain must be validated. eg. fridges, cool chambers, production area, Local T-alarms (in addition to central CMS)

System Validation and T-mapping Calibration Alarm testing (local and CMS) part of Validation

System Validation and T-mapping The T-monitoring is done by means of an airsensor and productsensor, both of which generate alarms. The airsensor is placed in the air of the storage device and is used to prewarn in case of a T- problem. The productsensor is placed in a liquid of which the properties are similar to the product (as proven by validation). The location of both sensors is based on a detailed T-study of the cold room : T-mapping. Rode Kruis

System Validation and T-mapping Cold Room Validation by T-mapping 1) Positioning T-sensors (loggers) in the air, one in every corner and one in the middle. 2) Positioning T-sensors in productbags filled with antifrogen L solution : volume equivalent to the normal volume of the stored component. Rode Kruis

System Validation and T-mapping Cold Room Validation by T-mapping 3) Perform a 24h T-mapping with a minimum of products filled with antifrogen L solution to prove the temperature is constant in time and space and thus meets the target temperature dt + and dt 4) Perform a T-mapping were a power failure is simulated to see how the temperature of the product reacts and to determine the alarm limits.

System Validation and T-mapping Cold Room Validation by T-mapping 5) After the T-mapping the placement of airsensor and productsensor is determined : - the airsensor at the coldest place - the productsensor at the warmest place (if there is a difference). This way both the low limit and the high limit is covered.

System Validation and T-mapping Cold Room Validation by T-mapping 6) Perform an open door test to investigate the influence on the system. 7) After these test re-evaluate if: - The airsensor and the productsensor are placed at the right place. - The alarmlimits cover the criteria of the product during routine work.

Transport boxes Collection Transport Processing Storage Distribution

Transport boxes Blood components should be transported by a system which has been validated to maintain the recommended storage temperature of the component over the proposed maximum time and extremes of ambient temperature of transport* Blood components : - Red Blood Cells - Platelets - Fresh Frozen Plasma *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

Transport boxes : Red Blood Cells Insulated box with a capacity of 16 blood bags Use of 4 cooled gel-packs Ambient T between 15 C and 25 C, the transport meets the acceptance criteria, for 4h45 ' with a minimum loading and during 7h10 ' at a maximum load Extreme ambient T of 50 C the transport meets the acceptance criteria, for 2h20 ' with a minimum loading and during 3h50 ' at a maximum load

Transport boxes : Platelets Insulated box with a capacity of 16 platelet bags, no gel-packs. 20 C - 24 C 18h15 at normal ambient temperature 15-25 C 1h20 at ambient temperature of 50 C with a minimum loading and during 2h25 ' at a maximum load 1h05 at ambient temperature of 4 C with a minimum and maximum loading

Transport boxes : Plasma Insulated box with dry ice Fresh frozen plasma units in the internal compartment divisions, with 1 scoop dry ice pellets to 2 sides ensures - at a normal ambient temperature of 25 C - a temperature of < -25 C during 11h45

Temperature indicators Collection Transport Processing Storage Distribution

Temperature indicators It is recommended that some form of temperature indicator is used to monitor the transit temperature.* How can we be sure that the product is kept at the correct T-conditions? Looking for T-monitoring during transport for processoptimalisation : is the cold-chain closed? The solution is the application of a special label on the blood bag in combination with a good internal transport system. *European Committee Guide to the preparation, use en quality assurance of Blood components 2013

Temperature indicators Implementation of Temperature Indicators in the Austrian Tyrol. Harald Schennach, MD, Assoc. Prof. Head of Institute Central Institute for Blood Transfusion and Immunology (ZIB) TILAK- University Clinics - Regional Hospital Anichstrasse 35 - A-6020 INNSBRUCK

Questions? jan.ceulemans@rodekruis.be

Thank you jan.ceulemans@rodekruis.be