Differential Pressure Transmitter Model DPT-10



Similar documents
Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Compact pressure switch Flameproof enclosure Ex d Model PCA

Pressure transmitter For general industrial applications Model A-10

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Technical Information RIA14

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

TEIP11 I/P signal converter for standard signals. Measurement made easy

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Precision digital pressure gauge Model CPG1500

Software and Display instruments

Plastic tube flowmeters Series PT/PS

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

SITRANS F flowmeters SITRANS F M

Digital inductive conductivity transmitter

Inductive sensor NI10-M18-Y1X-H1141

How To Use A Flowmeter

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Electronic Pressure Monitoring New Products

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Technical Data. Dimensions

Bypass level indicator With magnetic display Model BNA

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

2.12. page Products for Explosion hazardous Environment

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Hand-held thermometer Model CTH7000

Technical data sheet TDS0070

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Bimetal thermometer Model 52, industrial series

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Flow switches Series AD/VH

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Rosemount 752 FOUNDATION fieldbus Remote Indicator

How To Make A Smart Transmitter

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Model 3051 Pressure Transmitter with HART Protocol

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Micro Motion Model D and DL Coriolis Flow and Density Meters

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

CAPACITIVE LEVEL METERS CLM 36

Assisted lift operated 2/2-way solenoid valves Type EV250B

Level measurement in bulk solids. Capacitive VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Product Information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ph/redox Measurement MyPro CPM 431

Differential-Hall-Effect based Sensors Series A5S

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Technical Data. Dimensions

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

SEISMIC VELOCITY TRANSDUCER T1-40

Combi switchbox with integrated 3/2 way pilot valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Redundancy Module QUINT-DIODE/40

Microcor Wireless Transmitter (MWT)

Model 266MST Differential Model 266RST Absolute. Measurement made easy. 2600T series pressure transmitters. Engineered solutions for all applications

Electronic Pressure Switch EDS 300

Solenoid Valve Island Type 3965

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

3DLevelScanner II TECHNICAL DATA SHEET

DUST EMISSION MONITORING SYSTEM

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Pressure transmitter PASCAL CV

Electronic Pressure Switch EDS 3000

OPTIMASS 6000 Technical Datasheet

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Linear Luminaire with LED Series EXLUX 6402/2

distributing & controlling system solutions

Heating, air-conditioning, cooling

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Relative pressure transmitter type 520

Rosemount 333 HART Tri-Loop

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Data Sheet PS1B Pressure Switch

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

OPTIMASS 1400 Technical Datasheet

Continuous level. Non-contacting measurement

Transcription:

Electronic Pressure Measurement Differential Pressure Transmitter Model DPT-10 WIKA Data Sheet PE 86.21 Applications Process engineering Pharmaceutical Food and beverage industries Special features High measuring accuracy Scaleable measuring ranges Various hazardous area approvals Seven different housing variants Configuration via DTM (Device Type Manager) according to FDT (Field Device Tool) - concept (e.g. PACTware) Bildunterschrift Differential Pressure Transmitter Model DPT-10 Description With its 4... 20 ma, 4... 20 ma HART, PROFIBUS PA or FOUNDATION Fieldbus output signals, combined with either intrinsically-safe or flameproof ignition protection (in accordance with ATEX), the DPT-10 is ideally suited to applications requiring these features. The electronics of all of these transmitters, even for the flameproof variant, are intrinsically safe. Thus it is possible to make adjustments on the instrument in EX areas while the instrument is live. Versatile in application The DPT-10 is suitable for many industrial measuring requirements, such as flow measurement using differential pressure transducers, level measurement or filter and pump monitoring. With diaphragm seals fitted, the DPT-10 is also suitable for harsh process conditions. As a result of the available measuring ranges of 0... 10 mbar up to 0... 40 bar and a static pressure limitation of up to 420 bar, the instrument can be used in almost any application. The internal digital signal processing, combined with proven sensors, guarantees high accuracy and the best long-term stability. There are seven different housing variants available, and thus, it is possible to select a variant suited to every operating environment. The housing itself can be rotated through 330, and is available in plastic, aluminium and stainless steel. An electropolished stainless steel housing (316 L) is available to meet the high demands of the food industry and pharmaceutical industry. Easy configuration and operation Service and configuration at the instrument is carried out using the optional display and operation module, which can be fitted in four positions. The operation menu has a simple and self-explanatory structure and has seven selectable languages as standard. Alternatively, the operating parameters can be set using the PACTware free and non-proprietary configuration software. An instrument-specific DTM enables easy integration into a corresponding Distributed Control Systems. WIKA Data Sheet PE 86.21 04/2010 Page 1 of 8 Data sheets showing similar products and accessories: Process Pressure Transmitter; Model IPT-10, standard version; see Data Sheet PE 86.11 Process Pressure Transmitter; Model IPT-11, flush diaphragm; see Data Sheet PE 86.11

Specifications Model DPT-10 Measuring range 1) bar 0.01 0.03 0.1 0.5 3 16 40 2) Max. static working pressure bar 160 160 160 160 {420} 160 {420} 160 {420} 160 {420} Smallest possible span mbar 0.25 0.3 1 5 30 160 400 Lowest static pressure 3) mbar abs 0.1 Overload on one side bar 160 160 {420} Overload on both sides bar 240 240 {630} Accuracy Measuring ranges bar < 0.5 0.5 Long-term stability % URL/Year ± 0.18 ± 0.05 Reference accuracy 4) % of the span Measuring ranges 10, 30 mbar: from TD 1:1 ± 0.15 % x TD up to TD 15:1 TD from 15:1 100 mbar: up to TD 4:1 ± 0.075 % from TD 4:1 ± (0.012 x TD + 0.027) % Total Performance 5) 6) ± 0.15 % ± 0.15 % Influence of the system pressure 6) Zero point % URL ± 0.35 / 70 bar ± 0.075 / 70 bar Measuring range 10 mbar: 0.15 / 7 bar Span % URL ± 0.14 / 70 bar ± 0.14 / 70 bar Measuring range 10 mbar: 0.035 / 7 bar Influence of the media and ambient temperature 6) -10... +60 C 10 mbar and 30 mbar ± (0.31 x TD + 0.06) % 100 mbar ± (0.18 x TD + 0.06) % -40-10 / +60 +85 C 10 mbar and 30 mbar ± (0.45 x TD + 0.1) % 100 mbar ± (0.3 x TD + 0.15) % Mounting position influence mbar 4 0.5 bar, 3 bar, 40 bar 16 bar 0.5 bar, 3 bar 16 bar 40 bar ± 0.075 % ± (0.0015 x TD + 0.0053) % ± (0.08 x TD + 0.05) % ± (0.1 x TD + 0.1) % ± (0.12 x TD + 0.1) % ± (0.15 x TD + 0.2) % ± (0.37 x TD + 0.1) % Permitted temperature ranges Ambient 7) C -40 +80 (without Display) -20 +70 (with Display) Transport/Storage -40 +80 Process limits dependent upon the sealing material 7) C FKM/NBR: -20 +85 PTFE, copper: -40 +85 FKM, free of oil and grease: -10 +85 for oxygen applications Copper, PTFE: -20 +60; FKM: -10 +60 Temperature limits C With differential pressure lines longer than 100 mm: -40 +120 (-10 +120 with lateral flanges C22.8) Material Wetted parts Process connection C22.8, {316L, C276} Diaphragm: 316L, C276, {Tantalum, C276 Gold-Rhodium coated, Monel400 } Seals: FKM/FPM, NBR, copper, {PTFE} Internal transmission fluid 8) Silicone oil (halocarbon oil for oxygen applications) Case Plastic (PBT; polyester), {aluminium}, {stainless steel 316L} Weight kg approx. 4.2 4.5 depending on the process connection and case version Electrical data Power supply U B V DC non-hazardous: 14 36 Ex ia: 14 30; Ex d: 20 36; {FOUNDATION fieldbus und PROFIBUS PA Ex ia: 9... 24 Ex d 12 32} Output signal 4 20 ma, 2-wire {4... 20 ma, 2-wire with a superimposed communication signal HART }, {FOUNDATION Fieldbus }, {PROFIBUS PA} Dead time ms 100 Time constant (63 %) ms 180 (measuring ranges 10, 30 mbar: 250) Damping s 0 999, adjustable Permissible max. load R A in Ω R A = (U B U Bmin ) / 0.023 A Page 2 of 8 WIKA Data Sheet PE 86.21 04/2010

Explosion protection Ex protection 9) ATEX Category II 1G, II 1/2G, II 2G Ex ia IIC T6 T1 II 1/2 G, II 2 G Ex d ia IIC T6 T1 Ambient conditions CE-mark EMC 2004/108/EC interference emission and interference immunity per EN 61 326-1 industrial application Interference emission Limit Class A and B, 94/9/EC EN 50 014 (general part), EN 50 020 (intrinsic safe), EN 50 284 (zone 0), {EN 50 281-1 (dust Ex)} Shock resistance g 100 per IEC 60 068-2-27 (Shock mechanical) Vibration resistance 10) g 4 (5 100 Hz) (Vibration under resonance) Electrical ingress protection Overvoltage Category III Protection Class II IP66/67 (standard housing) {} Items in curved brackets are optional extras for additional price. 1) Other measuring ranges can be set via the respective Turndown. 2) Measuring range 40 bar, "-" side overload range unilateral up to 100 bar. 3) Valid with reference conditions according to IEC 60 770. 4) Includes non-linearity after limit point setting, hysteresis and non-repeatability in accordance with IEC 60 770. 5) Includes non-linearity, hysteresis, non-repeatability, thermal changes, zero point and static pressure influence (Pstat= 70 bar) in the temperature range -10 +60 C. 6) Values are not valid for tantalum diaphragm. 7) Restrictions of process temperature for oxygen -20 +60 C / the lowest temperature for PN 420: -10 C. 8) Operating pressure with halocarbon oil - higher than 1 bar abs. 9) The operating conditions and safety-relevant data in the approval documents must be read. 10) Tested in accordance with directives, GL characteristic line 2 (not for double chamber cases in stainless steel). URL = basic measuring range TD = Turndown Electrical connection Non-hazardous area Hazardous area Legend: power supply load - supply minus + supply plus 2-wire connection Electrical connection Non-hazardous area Hazardous area PLC Segment coupler Power hub WIKA Data Sheet PE 86.21 04/2010 Page 3 of 8

Process connection Oval flange, connection 1/4-18 NPT or RC 1/4 with vent at rear Measuring cells 10 and 30 mbar Measuring cells 100mbar Connection Mounting Material Equipment ¼-18 NPT IEC 61518 7/16-20 UNF Stainless steel C 22.8 2 vent valves 1) ¼-18 NPT IEC 61518 7/16-20 UNF AISI 316L 2 vent valves 1) ¼-18 NPT IEC 61518 7/16-20 UNF C276 Without valves / plugs RC ¼ 7/16-20 UNF AISI 316L 2 vent valves 1) ¼-18 NPT IEC 61518 PN 160: M10; PN 420: M12 Stainless steel C22.8 2 vent valves 1) ¼-18 NPT IEC 61518 PN 160: M10; PN 420: M12 AISI 316L 2 vent valves 1) ¼-18 NPT IEC 61518 PN 160: M10; PN 420: M12 C276 Without valves / plugs 1) Material: AISI316L /1.4404 Oval flange, connection 1/4-18 NPT or RC 1/4, with lateral venting Measuring cells 10 and 30 mbar Measuring cells 100 mbar Connection Mounting Material Equipment ¼-18 NPT IEC 61518 7/16-20 UNF Stainless steel C 22.8 2 vent valves, 4 plug screws 1) ¼-18 NPT IEC 61518 7/16-20 UNF AISI 316L 2 vent valves, 4 plug screws 1) ¼-18 NPT IEC 61518 7/16-20 UNF C276 Without valves / plugs RC ¼ 7/16-20 UNF AISI 316L 2 vent valves, 4 plug screws 1) 1) Material: AISI316L /1.4404 Page 4 of 8 WIKA Data Sheet PE 86.21 04/2010

Housing variants Single chamber housing, plastic Single chamber housing, aluminium Single chamber housing, cast stainless steel Single chamber housing, stainless steel, deep-drawn Dual chamber housing, plastic Dual chamber housing, aluminium Dual chamber housing, cast stainless steel WIKA Data Sheet PE 86.21 04/2010 Page 5 of 8

Accessories Three-way valve manifolds Five-way valve manifolds With upstream pressure equalising valves it is possible to avoid unilateral overpressure loadings during both start-up and operation as well as enabling zero point checks during operation. Furthermore, they enable the isolation of the process lines without interference to the running process. These pressure equalising valves with integrated shut-off valves, and also purge and ventilating valves, in addition enable the venting of the pressure gauge on one or both sides and enable the supply line to be purged. Diaphragm seals Differential pressure transducer Model DPT-10 differential pressure transmitters can be adapted to the harshest conditions in the process industry by using diaphragm or diaphragm in-line seals. Thus, the transmitters can be used at extreme temperatures, and with aggressive, corrosive, heterogeneous, abrasive, highly viscous or toxic media. As a result of the wide variety of aseptic connections (such as clamp, threaded pipe or DIN 11 864 aseptic connections) measuring assemblies meet the high demands of sterile process engineering. Differential pressure transducers for flow measurement are available as accessories. Depending on the application, the differential pressure transducers are designed as simple push plugs, measuring flange or complete measuring path. Page 6 of 8 WIKA Data Sheet PE 86.21 04/2010

Display and operating module Display and menu item number LC-Display Menu languages: German English French Spanish Polish Italian Dutch Operating keys DTM user interface For HART output signals, Profibus-PA and FF, a DTM is available in accordance with the FDT-standard. The DTM provides a self-explanatory and clear user interface for all setup and control processes of the transmitter. For testing purposes, it is also possible to simulate process values and archive the parameter data. Recording of the measured values is available for diagnostic purposes. Tank volume calculation The additional tank volume calculation of the DTM function can be used to reproduce any optional tank geometry. The corresponding linearisation table is generated automatically. The linearisation table can be transferred directly to the transmitter. WIKA Data Sheet PE 86.21 04/2010 Page 7 of 8

Accessories Model Special features Order No. DIH52-F and DIH62-F Indication module DIH52-F and DIH62-F, 5-digit display, 20 segment bargraph, without separate power supply, with additional HART -functionality. Automatic adjustment of measuring range and span. Local-master functionality: Setting the measuring range and unit of the connected transmitters using HART -standard commands. explosion protection according to ATEX. Model 010031 HART -Modem for USB-interface, specifically designed for use with modern notebooks 11025166 Model 010001 HART -Modem for RS232-interface 7957522 Model 010041 HART -Modem for Bluetooth-interface [EEx ia] IIC 11364254 FC475HR1EKL9 FC475HR1EKLU MFC4150 HART protocol, Li-Ion battery, power supply 100... 240 V coloured indication with background lighting, Bluetooth and infrared interface ATEX, FM, CSA and IECEx(i) (including FISCO if available). HART protocol, NIMH battery, power supply AC 90... 240 V, with EASY UPGRADE, ATEX II 2G (1GD) EEx ia IIC T4 HART protocol, universal power supply, cable set with 250 Ω resistance, with DOF upgrade, with Ex-protection 11405333 DTM Collection incl. PACTware, contains DTMs for WIKA field devices 12513636 Display and operation module, housing cover in aluminium, with window 12298884 Display and operation module, housing cover in cast stainless steel, with window 12298906 Display and operation module, housing cover in plastic, with window 13315277 Display and operation module, housing cover in stainless steel, electropolished, with window 13315269 Three-way valve CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Five-way valve CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Oval flange 1/4 NPT Cr-Ni-steel CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Oval flange ½ NPT Cr-Ni-steel CrNi-steel, PN 420, shape A, Nace compliant, 3.1 material certificate Mounting bracket for wall or pipe mounting, stainless steel 11553945 The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 8 of 8 WIKA Data Sheet PE 86.21 04/2010 04/2010 GB WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. (+49) 9372/132-0 Fax (+49) 9372/132-406 E-mail info@wika.de www.wika.de