Email: tjohn@mail.nplindia.ernet.in



Similar documents
Propagation Channel Emulator ECP_V3

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

RECOMMENDATION ITU-R F (Question ITU-R 157/9) b) that systems using this mode of propagation are already in service for burst data transmission,

RF Measurements Using a Modular Digitizer

Description: Multiparameter System (4 or 8 channels)

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Online Filtering for Radar Detection of Meteors

Lab 5 Getting started with analog-digital conversion

PCM Encoding and Decoding:

Realtime FFT processing in Rohde & Schwarz receivers

APPLICATION NOTE GaGe CompuScope based Lightning Monitoring System

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Non-Data Aided Carrier Offset Compensation for SDR Implementation

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

High-Resolution Doppler-Polarimetric FMCW Radar with Dual-Orthogonal Signals

Lab 3: Introduction to Data Acquisition Cards

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Tri-Band RF Transceivers for Dynamic Spectrum Access. By Nishant Kumar and Yu-Dong Yao

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

Manual Analysis Software AFD 1201

Instruction Manual Service Program ULTRA-PROG-IR

Acoustic Processor of the MCM Sonar

Disturbance Recoder SPCR 8C27. Product Guide

GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS

Measuring Temperature withthermistors a Tutorial David Potter

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

4 Digital Video Signal According to ITU-BT.R.601 (CCIR 601) 43

KBA Oktatási Kft OKÉV nyilvántartási szám:

Space Environment and Satellite Systems: Removing Clutter from Ground-to-Satellite Signals. Sigrid Close

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

MSAN-001 X-Band Microwave Motion Sensor Module Application Note

US-Key New generation of High performances Ultrasonic device

Lab 9: The Acousto-Optic Effect

Data Transmission. Data Communications Model. CSE 3461 / 5461: Computer Networking & Internet Technologies. Presentation B

Lab Exercise 1: Acoustic Waves

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

MODULATION Systems (part 1)

The Development of a Pressure-based Typing Biometrics User Authentication System

Android based Alcohol detection system using Bluetooth technology

Technical Information Manual

Optimizing IP3 and ACPR Measurements

Quanser NI-ELVIS Trainer (QNET) Series: QNET HVAC. Heating, Ventilation, and Air Conditioning (HVAC) User Manual. User Manual

ADVANCED APPLICATIONS OF ELECTRICAL ENGINEERING

NI USB-5681 RF Power Meter Specifications

S2000 Spectrometer Data Sheet

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

MUSIC-like Processing of Pulsed Continuous Wave Signals in Active Sonar Experiments

LLRF. Digital RF Stabilization System

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

telemetry Rene A.J. Chave, David D. Lemon, Jan Buermans ASL Environmental Sciences Inc. Victoria BC Canada I.

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Implementation of Digital Signal Processing: Some Background on GFSK Modulation

HDO700 P FIBRE OPTIC TRANSMITTER

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

Product Information S N O. Portable VIP protection CCTV & Alarm System 2

E190Q Lecture 5 Autonomous Robot Navigation

Broadband Networks. Prof. Dr. Abhay Karandikar. Electrical Engineering Department. Indian Institute of Technology, Bombay. Lecture - 29.

SHARING BETWEEN TERRESTRIAL FLIGHT TELEPHONE SYSTEM (TFTS) AND RADIO ASTRONOMY IN THE 1.6 GHz BAND. Paris, May 1992

Module 13 : Measurements on Fiber Optic Systems

COMPARISON OF EISCAT RADAR DATA ON SPACE DEBRIS WITH MODEL PREDICTIONS BY THE MASTER MODEL OF ESA

[Download Tech Notes TN-11, TN-18 and TN-25 for more information on D-TA s Record & Playback solution] SENSOR PROCESSING FOR DEMANDING APPLICATIONS 29

NI 6601/6602. Contents CALIBRATION PROCEDURE. ni.com/manuals

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

AM/FM/ϕM Measurement Demodulator FS-K7

Power Amplifier Gain Compression Measurements

Revision of Lecture Eighteen

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

FAST Fourier Transform (FFT) and Digital Filtering Using LabVIEW

Figure1. Acoustic feedback in packet based video conferencing system

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

m Antenna Subnet Telecommunications Interfaces

GSM/EDGE Output RF Spectrum on the V93000 Joe Kelly and Max Seminario, Verigy

SignalPad Data Logging and Analysis Software

Aircraft cabin noise synthesis for noise subjective analysis

FFT Spectrum Analyzers

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Analog vs. Digital Transmission

How To Use A High Definition Oscilloscope

Contents Introduction Problems, Classification and Structure of ARM Equipment Radio Receiver Applications for Radio Monitoring System

LabVIEW Day 1 Basics. Vern Lindberg. 1 The Look of LabVIEW

Data Acquisition in LabVIEW

Analog and Digital Signals, Time and Frequency Representation of Signals

MATRIX borehole logging system

EPM2000 LabVIEW Building Applications Instructions

Measuring the Wireless Channel

Advanced Signal Processing 1 Digital Subscriber Line

Use Data Budgets to Manage Large Acoustic Datasets

Satellite Telemetry, Tracking and Control Subsystems

AIR DRM. DRM+ Showcase

DS1104 R&D Controller Board

Introduction to acoustic imaging

Transcription:

USE OF VIRTUAL INSTRUMENTS IN RADIO AND ATMOSPHERIC EXPERIMENTS P.N. VIJAYAKUMAR, THOMAS JOHN AND S.C. GARG RADIO AND ATMOSPHERIC SCIENCE DIVISION, NATIONAL PHYSICAL LABORATORY, NEW DELHI 110012, INDIA Email: tjohn@mail.nplindia.ernet.in ABSTRACT Virtual Instruments (VIs) have found applications in a wide variety of test, measurement and automation problems encountered in research and industry. We describe here two specific VI applications for atmospheric research, using LabVIEW software. First, we describe the application of a VI for configuring the PC printer port for serial data acquisition for real-time graphical display of atmospheric pressure, temperature and humidity, telemetered to ground from in-situ atmospheric measurements made by a suitable pay-load on a tethered balloon. Next, we have applied a VI for phased array signal processing in a Doppler sound radar, in the complex Fourier frequency domain, to enhance the radar performance. Vertical wind profiles derived from the radar are included. INTRODUCTION As mentioned, we present here two applications of virtual instruments for atmospheric studies. In the first application, use is made of a PC printer port for serial data acquisition and simultaneous graphical display of real-time atmospheric pressure, temperature and humidity data on ground, obtained through standard telemetry (173 MHz), from in-situ measurements made by a suitable pay-load carried on a tethered balloon. The data acquisition is triggered and clocked in order to enable a continuous acquisition of frames of 8-channel data, each channel consisting of 16-bit data. The clock rate also determines the overall sampling rate. Proper channel assignment is automatically achieved by using a Sync. word which is assigned Ch-0 and ch-1 and the rest of the channels are reserved for external signals from the appropriate atmospheric sensors. The acquired data is also simultaneously stored in a hard-disk as an Excel file for future processing. Also included are the system details of the electronic hardware incorporated between the sensor and the PC printer port. Pl. see [1] and [2] for technical details. In the next application, phased array signal processing in a Doppler radar is described. In this example the use is made of a multi-channel NI-DAQ card from National Instruments capable of simultaneous sampling of 8 channels at a maximum sampling rate of 102.4 KHz per channel at 24 bit resolution. In the actual experimental set up, in a phased array Doppler sound radar an 8-channel transmitter excites different antenna elements to enable atmospheric illumination by the sound waves (at 2150 Hz) in vertical, North and West modes. The resulting backscattered signals by atmospheric temperature in-homogeneity are suitably delayed and combined to define the receiving antenna beam in the same direction as the transmitted beam. The signal processing of the received signals incident upon multiple sensors is carried out in the complex Fourier frequency domain to enhance the signal-tonoise which is seen to increase the range capability of the Doppler radar by a factor of 2 (up to 1km) or more depending upon the ambient noise conditions. Some examples of vertical wind profiles derived from the radar are also included. APPLICATION-I : PC-PRINTER PORT FOR TETHERED BALLOON DATA ACQUISITION In this section the details of hardware and software employed for the PC-printer port application is described. In Figure 1 is shown a simplified functional blocks of the electronics which is the hardware part preceding the PC printer port. This consists of a multiplexer to select specific sensor to input analog data into the 12-bit resolution serial ADC which is triggered by a start pulse to initiate conversion. The ADC is clocked such that a 16-bit data stream is outputted with 4 leading zeros.

Fig. 1 Functional Block Diagram of Data Acquisition System using PC-printer The front panel of this printer-port based virtual instrument as it is displayed on the PC-monitor is shown in Figure 2. There are two panels. One displays the binary data frame while the other displays the plot of the stream of data points acquired through multiple sensors. Apart from these two display panels the front panel also contains indicators showing Trigger and Clock status. There are others indicating Channel number, parameter measured and corresponding output in volts. The data entry to a file is designated by the path and file name along with real-time stamp. FIG.2. LabVIEW Front Panel Display of real-time multi-channel data

APPLICATION II : VERTICAL WIND PROFILING BY DOPPLER SOUND RADAR In this application we describe a simple and an elegant algorithm implemented on a PC using the tools available in LabVIEW software a virtual instrument platform for WINDOWS OS - for signal processing of the multiple-sensor data in a phased array Doppler sound radar system. We have obtained vertical wind profiles up to a kilometre altitude effectively enhancing the range capability by a factor of 2 through the implementation of this signal-processing algorithm. The receiver hardware includes a set of very low-noise front-end amplifiers followed by a PCI compatible 24-bit Data Acquisition Card, NI 4472, mounted on a PC for simultaneous acquisition of data from 8-channels of the phased array antenna matrix employed for receiving the scattered acoustic signal. Computer Array Signal Processing Algorithm We know that in a phased array signal processing a simple phase shifting and adding operation among the sensor outputs results in an improvement of signal-to-noise (S/N) ratio by a factor equal to the number of sensors [3]. In addition, we stand to gain higher signal-to-noise ratio by resorting to Fourier-domain analysis which possesses an inherent property of providing higher resolution spectral band-width in each range-bin of a radar signal. This means that an additional multiplication factor determines the overall S/N. In the actual experiment, since the sound radar is a pulsed system, each transmitted pulse is made of packet of 2150Hz of 100ms width which would amount to 15m height resolution. The receiver is blanked for the next 200ms to avoid all sound reflections in the vicinity of the receiving system. This amounts to providing an altitude threshold up to 35m. The actual processing of scattered signal begins for range-bins beyond this threshold height. The Pulse Repitition Rate is 6.6 s. This allows for the height range of 1 km by assuming a propagation velocity of 330m/s for the sound waves. Next we consider the implementation of a Processing Algorithm to Determine Direction to a Signal source, θ t [4]. Given an array of detector signals p i (n), select a direction of interest θ a (θ t is unknown). For each of the D detector signals p I (n) collect N samples of p I (n), i = 0, D-1. Transform sequence p I (n) to P I (k) using N-point FFT. Adjust phase of each Fourier component of P I (k) to yield Q I (k), using the following relationship, ϕ I (K) = 2 Π x cos(θ a ) f k I V Where x is the detector spacing (m), V is the wave velocity (330m/s), f k is the analog frequency of the k- th spectral component, i is the detector index, phase adjustment defined above is for the k-th spectral component of i-th detector signal (rads). This aligns the phase of the i-th signal with first detector for a preferred direction. Add spectrum of all phase-adjusted signal components, Q i (k) to obtain Q sum (k) with N samples. Now it is the question of finding the total signal power in the spectrum of combined signals to determine the true angle of arrival in the chosen direction θ a. While implementing this algorithm, the data obtained has been acquired simultaneously on 8-channel at a sampling rate of 21.5 khz. Each range bin is given by 2150 points corresponding to 100ms of transmitted pulse. For each range-bin 2150 data points are obtained from each of the 8-channels, first, the autocorrelation values are computed and then Hanning window is applied before DFT is computed and then the power spectral density (PSD) is calculated for each of these data set. Then, these 8-channel PSDs are added together for a given range-bin to validate the data, in terms of the best S/N ratio criterion. After validation further processing is done for obtaining the wind profile through computed Doppler shifts. The best S/N-criterion validation is done by taking three consecutive soundings and looking for 3-hits for a given range bin from these 3- data sets. The hits are defined as the coincidence of 3-points, for a given range-bin, which are seen to be in phase, since fundamentally noise does not fulfil this criterion. Based on these above procedures we have obtained some of the vertical Doppler profiles. These profiles are shown in Figure. 3 panels marked A, B, C and D. These are the afternoon and evening observations made during the month of January-2004. Panels A & B show a quiescent wind conditions that is observed during stable afternoon conditions. However, in the late evening hours due to increase in ambient noise conditions we could resolve Doppler for some select portions of altitudes by applying the criterion for best S/N ratio. Panels C & D display winds derived under such noisy conditions.

Panel-A Panel-B Panel-C Panel-D Fig. 3 Panels A-B show stable atmospheric conditions obtains for resolving winds upto 1 km. Panels C-D depict noisy conditions during observations allowing resolving of Doppler only in patches up to different altitude regions.

CONCLUSION We have presented here two applications, useful for atmospheric studies, which are developed using LabVIEW, a virtual instrument platform. We have found LabVIEW extremely versatile and user friendly for scientific and research applications such as ones presented here. Also, we have performed online processing using LabVIEW. ACKNOWLEDGEMENT We deeply appreciate the support given by Mrs. Madhu Bahl and Mr. R.M. Khanna in making available the Sound Radar facility for us to record the data for our present analysis. REFERENCES [1] P.H. Anderson, Use of a PC Printer Port for Control and Data Acquisition, presented at Technology Interface, fall- 1996, Department of Electrical Engineering, Morgan State University. (pl. see also http://et.nmsu.edu/~etti) [2] Using the Parallel Port in LabVIEW - National Instruments home page developer zone - External serial interfaces. [3] S.U. Pillai, Array Signal Processing, Springer-Verlag, pp. 8-14, 1989. [4] Fred Depiero, web-page articles on Digital Signal Processing, Calpoly State University, 2001