SHDSL LAN EXTENDER H301A. User Manual



Similar documents
2-Pair. Managed SHDSL Ethernet Extender. User s Manual

Long Range Ethernet Extender

V101. VDSL LAN Extender

VDSL2 LAN Extender User Manual

LevelOne User Manual VDS-0120 Ethernet over VDSL2 Converter (PSE)

Ethernet over VDSL2 PoE PD Converter

CONTRIBUTION ABSTRACT

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

IEX-402-SHDSL Series Quick Configuration Guide First Edition, January 2013

Speed-DSL 9.2 Ethernet connection over 8-wires up to 9.2 Mbit/s. Manual * * * *

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Connecting the DG-102S VoIP Gateway to your network

Ethernet over VDSL2 Converter VC-201A / VC-204

Extending E1 and Ethernet using the same Copper Pairs

Digital Subscriber Line (DSL) Transmission Methods

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

T3 Mux M13 Multiplexer

S-Access Etherlink II Repeater TDM Based SHDSL.bis

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

SOHOware Long Reach Ethernet (LRE) Solution

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s. Manual

DSL Variations. NEXTEP Broadband White Paper. Broadband Networks Group. Definitions and differences of Digital Subscriber Line variations.

Cisco G.SHDSL High Speed WAN interface Card with IEEE 802.3ah EFM Support for Cisco Integrated Services Routers

LBNP RS-232/485/422 serial device server. User manual

Gigabit Switching Ethernet Media Converters - Product User Guide

BLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1

User Manual IC-485AI

Extending Ethernet over 2-wire Copper Networks

P-791R v2. Quick Start Guide. G.SHDSL.bis Router DEFAULT LOGIN. Administrator Password User Password. Version /2007 Edition 1

Terminal and Dimension

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

LevelOne VOI H.323 VoIP Gatekeeper. User Manual

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

SecureLinx Spider Duo Quick Start Guide

Loop-IP6700 TDMoEthernet

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

GV-Data Capture V3 Series User's Manual

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

FlexDSL MiniFlex. SHDSL.bis and Optical Mini DSLAM. SHDSL.bis and Fiber Up to 300Mbps Ddd. Ethernet. Features

XDSL and DSLAM Access Technologies

Provides one channel for Ethernet over existing

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

PAMSPAN Standalone Type C-COM CORPORATION. User Manual. Ver. UM-PAMSPAN E. This Manual is for S/W ver. 3.

Public Switched Telephone System

2 To 1 Serial (RS-232) AUTO SWITCH. AS-251S User Manual

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

IFS SP-PoE Splitter User Manual

Pan Dacom. Nets work together. SPEED-DSL 2.3 Ethernet connection over 2-wires up to 2.3 Mbit/s ( A, A) Manual

N560 series H/W Installation Guide

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

HSG Engineering Tech Bulletin

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

Orion2+ SHDSL.bis Solution with 11Mbit/s and 15Mbit/s per Copper Pair

GEU Port Gigabit Switch

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Terminal and Dimension

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Optimux-134, Optimux-125

VOICE RECORDING SYSTEM ISDN PRI / BRI

Intel System Engineers Documents. DSL General Overview

MDI/MDIX) FEP-32008T-3

YM.SW.105.UM.EN.D00REV FH11 Fri Jul 25 16:00: Page 1

Voice Over Internet Protocol (VoIP) Configuration

TrueAlarm Fire Alarm Systems

Optimux-34, Optimux-25

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Optimux-134, Optimux-125

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Megapixall Security Tools & Accessories

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

8-Port PoE Network Switch

Perle 10/100 Ethernet Media Converters

Setting Up and Testing the MAX Hardware

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Chapter 1 Introduction

Provides one channel for Ethernet over existing

Loop-IP6702 TDMoEthernet

Black Box Explains: DSL

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

LIEBERT VNSA Installation Sheet

Wireless Router Setup Manual

4-Band VDSL CO/CPE MODEM USER S MANUAL Ver. A.2. 4-Band VDSL CO/CPE Modem USER S MANUAL

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Network Design. Yiannos Mylonas

ZyWALL 5. Internet Security Appliance. Quick Start Guide Version 3.62 (XD.0) May 2004

Transcription:

SHDSL LAN EXTENDER H301A User Manual Rev. 1.0 Yoda Communications, Inc.

Yoda Communications, Inc. Address 2F, No. 3-1, Industry East Road IX, Science Based Industrial Park, HsinChu, Taiwan Tel 886-3-5632323 Fax 886-3-5636420 Web site http://www.yoda.com.tw 2

1. Introductions The STU-LAN H301A, an SHDSL (Single-pair High-bit-rate Digital Subscriber Line) LAN Extender, provides a broadband full duplex transmission with bandwidth up to 5.696 Mbps over a pair of copper line for point-to-point LAN connectivity between two Ethernet networks. The distances can reach respectively up to 7,000 feet (about 2.1 Km) and 10,000 feet (about 3 Km) at the rate of 5.696 Mbps and 4.608 Mbps for a pair of 24AWG (0.5 mm) copper wire, and could reach even around 22,500 feet (about 6.8 Km) at 192Kbps. With its rate adaptive features, H301A may provide longer reach on transmission distance. Users can also select a fixed data rate for the copper line ranging from 64 Kbps to 5.696 Mbps. The H301A provides a craft port for user to configure the settings and to monitor the connection status. Each STU-LAN H301A can be configured into either STU-C for central side or STU-R for remote side. The H301A conforms to the ITU-T Rec. G.991.2, to meet G.shdsl.bis network requirements. A pair of STU-LAN H301A offers a cost effective symmetrical broadband solution for bandwidth-hungry applications such as LAN-to-LAN connectivity, Internet Access and VoIP applications over two twisted pairs. 2. Application Notes 1) Ethernet To Ethernet Bridge Extension Ethernet Interface 5.696 Mbps at 7,000 ft Ethernet Interface Central Office H301A STU-C SHDSL Copper Lines Remote Side H301A STU-R 3

3. Features ITU-T Rec. G.991.2 G.shdsl.bis Compliance SHDSL Trellis Coded Pulse Amplitude Modulation (TCPAM) Line Code Fixed Data Rate Selection from 5696 Kbps to 64 Kbps for SHDSL line Adaptive Data Rate from 4608 Kbps to 192 Kbps for SHDSL line Maximum Transmission Distance: 22,500 ft over 26AWG twisted pair Noise Margin 1 db is guaranteed for fixed rate and adaptive rate modes. STU-R will follow STU-C s speed for 192Kbps~2304Kbps in fixed rate mode. RJ-48 Connector for SHDSL line connections RJ-45 Connectors for 10/100 BaseT Ethernet Switch ports Ethernet Auto-Negotiation for 10/100 BaseT Ethernet Auto-MDIX for Auto Tx/Rx Swap Craft Port for Network Management Configurations 5 LED status indicators Power feedings: 110/220VAC to 12VDC Power Adaptor 4. Packing Contents Inside the package you should find: (1) One STU-LAN H301A unit with dimension of 150x135x30 (mm) (2) One power cord (3) One DB-9 Console Cable (4) One User s Manual (Compact Disk) Please check if the packing is damaged before unpacking or any component is missing. If so, please contact your dealer immediately for replacement. 4

5. Installation Procedures Step 1 : Connect SHDSL Line to DSL RJ48 connector on H301A back panel Pin 4 & Pin 5 for SHDSL Line RJ-48 Connector Pin Assignment for SHDSL Line Interface Step 2 : Connect Ethernet to RJ-45 Port with CAT 5 LAN cable Step 3 : Connect the power adaptor to the H301A 12VDC outlet Step 4 : Turn on the power. Set one H301A as STU-C from Craft port, and the other H301A as STU-R Step 5 : Set the desired Data Rate for SHDSL connection from Craft port. Note that both H301A must set the same data rate settings. Step 6 : Both units of H301A will automatically connect with each other. Turn on the power, and STU-LAN H301A will then execute self-test routines. There will be 2 or more handshaking cycles when adaptive rate is selected. The system will automatically adapt to maximum rate according to the loop distances. The maximum rate is 5696 Kbps for 1-pair SHDSL line. 5

6. Front Panel LED Indicators 6.1 LED Indicators There are 5 LED indicators on the front panel of H301A displaying the current status. These LED indicators are described as following. POWER TEST LOOP LAN 100M Green On shows H301A power supply is normal. H301A is self testing after powered on. Green Flash shows SHDSL connection is in progress. Green On shows SHDSL loop connects successfully. Green On shows LAN port is in connection. Green Flash shows data activity on LAN port. Green On shows LAN Ethernet connection is at 100Mbps. 6

7. Craft Port Control The STU-LAN H301A provides an RS232C craft port for user to monitor the OA&M status through a VT100 terminal. This section covers the operation procedures, settings and for all screen selections. Connect the RS232 cable to the COM port of the computer as shown in the following diagram. Set the personal computer to VT100 or VT102 type through HyperTerminal. Press the <ESCAPE> key and the main menu will be shown on the screen of the terminal. The terminal operations can then start. If the <ESCAPE> key is pressed and the screen of the terminal does not display, this may be due to the incorrect COM port setting. Choose the right COM port (COM1 or COM2) on the computer, and press the <ESCAPE> key again to make sure that the main menu appears on the terminal screen. Note that the COM port should be set as 9600 bps, none parity, 8 data bit, and 1 stop bit. RS232 Cable VT100 / 102 Terminal Craft Port 9600, N, 8, 1 DB-9 Connector STU-LAN H301A Figure 7-1: Connection for Craft Port with RS232 Terminal 7

7.1 Main Menu Main Menu will display the connection status of the STU-LAN H301A unit and settings including two sections: Configuration, and Status. For details please refer to Table 7-1. Table 7-1 Main Menu The pull-down tree structure of the main menu is shown in Figure 7-2. DSL Mode Configuration DSL Speed Main Menu Default Configuration System Information Status System Status Figure 7-2: Pull-down Tree Structure of the main menu 8

7.2 Configuration Screen Configuration screen will display the selections of connection for the H301A unit and the screen includes three selections: DSL Mode Settings, DSL Speed Settings, and Default Configuration. For details please refer to Table 7-2. Table 7-2 Configuration screen 9

DSL Mode Settings: Table 7-3: DSL Mode Settings screen This screen provides DSL mode settings and user can update the settings from this screen. The initial values of DSL Mode settings are read from DIP switches. CO/RT: The item of CO/RT has 2 options: STU-C and STU-R. To establish a successful connection for two H301A units, it is necessary to set one unit to STU-C and the other unit to STU-R. 2P/1P: The item of 2P/1P has 2 options: 1 Pair and 2 Pairs. H301A supports only 1-pair SHDSL application. To establish a successful connection for two H301A units, it is necessary to set the two units to the same selection. 10

DSL Speed Settings: Table 7-4 DSL Speed Settings screen This screen provides DSL Speed Settings and user can configure DSL speed to set the transmission rate. For 1-pair setting in the DSL Mode menu, the options are as following; 64 kbps, 128 kbps, 192 kbps, 256 kbps, 384 kbps, 512 kbps, 768 kbps, 1152 kbps, 1536 kbps, 1544 kbps, 2048 kbps, 2304 kbps, 3072 kbps, 4608 kbps, 5696 kbps, and Adaptive speed. The user must set both units of H301A to the same speed selection in order to establish a successful connection for 64 kbps, 128 kbps, 3072 kbps, 4608 kbps, 5696 kbps, and Adaptive speed. For the rate speed options between 192 kbps and 2304 kbps, the STU-R H301A regardless its speed option will follow the speed of STU-C H301. When setting for adaptive rate, 2 or more activation cycles are necessary. The system will automatically adapt to maximum speed according to the loop distances. The maximum speed for 1-pair mode is 5696 kbps. 11

Default Configuration Setting: Table 7-5 Default Configuration Setting screen When Default Configuration is selected, all the settings of H301A will go back to default settings. For the screen as shown in Table 7-5, it indicates setting is finished and press <ESC> key will be back to previous screen. The default settings of H301A are as following: STU-C 1 Pair Adaptive speed 12

7.3 Status Screen The Status screen shows the connection status of H301A unit. The screen covers two selections: System Information and System Status. For details please refer to Table 7-6. Table 7-6 Status screen System Information: Table 7-7 System Information screen Items list in the above screen are explained as follows: Firmware Version: Indicates the firmware version in this unit. Vendor Model: Indicates this device s vendor model name. Vendor Information: Indicates the vendor s web site information. 13

System Status screen Table 7-8 System Status screen. The distance of this example is 6Kft and 26-AWG. Items list in the above screen are explained as follows: DSL mode: Indicates the current DSL mode setting. Speed setting: Indicates the current DSL speed setting. Speed actual (kbps): Indicates the actual DSL speed in kilobit per second. Link status of pair #1: Indicates the DSL connection status (either up or down) for pair #1. Link status of pair #2: Indicates the DSL connection status (either up or down) for pair #2. Noise Margin of pair #1(dB): Indicates the Noise Margin in db of pair #1. Noise margin of pair #2(dB): Indicates the Noise Margin in db of pair #2. 14

Line Attenuation of pair #1(dB): Indicates the Line Attenuation value in db of pair #1. The maximum value is 43 db when the DSL distance is 22500 ft, 26-AWG. Line Attenuation of pair #2(dB): Indicates the Line Attenuation value in db of pair #2. The maximum value is 43 db when the DSL distance is 22500 ft, 26-AWG. Activation state of pair #1(dB): Indicated the DSL startup activation state of pair #1. The value starts from 05 and gradually reaches the final value 16. The value 16 is the DSL link up state value. The general activation state sequence is 05 20 10 12 16. Activation state of pair #2(dB): Indicated the DSL startup activation state of pair #2. The value starts from 05 and gradually reaches the final value 16. The value 16 is the DSL link up state value. The general activation state sequence is 05 20 10 12 16. 15