ENVIRONMENTAL MANAGMENT OF PHARMACEUTICAL WASTES: EXPERIENCE FROM EGYPT

Similar documents
GUIDELINES FOR LEACHATE CONTROL

WASTEWATER TREATMENT OBJECTIVES

MEMBRANE TECHNOLOGY TREATING OILY WASTEWATER FOR REUSE

Department of Environmental Engineering

1.3 Wastewater and Ambient Water Quality

AP ENVIRONMENTAL SCIENCE 2007 SCORING GUIDELINES

Brewery Wastewater: 2010 Water and Wastewater Conference Page 1

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

Site Visit Report. MEAT PROCESSING FACILITY COD Reduction. Industrial Assistance Section Assessment Team

The First Step in Effluent Treatment

POTW PHOSPHORUS REMOVAL PROCESSES

Sewerage Management System for Reduction of River Pollution

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Lance DeClue, REHS Environmental Health Specialist II County of San Diego Department of Environmental Health

Looking after your Septic Tank System

MALAYSIA S REQUIREMENTS ON INDUSTRIAL EFFLUENT TREATMENT SYSTEMS -The WEPA Workshop and Annual Meeting February 2013 Siem Reap, Combodiaby

Florida Department of Environmental Protection

An introduction to EPAS

HUBER Vacuum Rotation Membrane VRM Bioreactor

Metal Ion + EDTA Metal EDTA Complex

Presented by Paul Krauth Utah DEQ. Salt Lake Countywide Watershed Symposium October 28-29, 2008

Removing Heavy Metals from Wastewater

Advanced Treatment of Hazardous Wastes(1) Advanced Treatment of Hazardous Wastes(2) Advanced Environmental Chemistry. Design of Solid Waste Landfill

Saudi Aramco Project Development

Dairy Processing Methods to Reduce Water Use and Liquid Waste Load. Kent D. Rausch Extension Specialist, Food Engineering

Natural and Advanced Treatment Systems for Wastewater Management at Municipal Solid Waste Disposal Site in Developing Countries

WASTEWATER TREATMENT

Planning, Designing, Monitoring and Inspection of Wastewater Treatment Systems of Industries

ALL YOU NEED TO KNOW...

Provided below is a description of the processes generating wastewater in a poultry plant and a typical pretreatment and full treatment system.

RESIDENTIAL TREATMENT SYSTEMS

City of Mebane Wastewater Collection and Treatment Facility

Wastewater Nutrient Removal

Evaluation of water stress of selected cases from water re-use or saving scenario s tested in SP5

Disposal of Fats, Oils, Grease and Food Waste Best Management Practice for Catering Outlets

Best Management Practices

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

Environmental Regulations & Best Management Practices CARPET CLEANING OPERATIONS. Carpet Cleaning Operations in the Capital Regional District

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

Treatment of dairy wastewater by natural coagulants

Ground Water Contamination by Leachate

Guidance on applying for approval of installation of a commercial onsite wastewater system

Improper storage of fuel on construction sites will increase the risk of water pollution that may occur as a result of leaks or spills.

Managing Floor Drains and Flammable Traps

STOCKMEIER water chemicals Strong bonds for clear water

Improper storage of potential pollutants will increase the risk of water pollution that may occur because of spills.

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE CHAPTER II SEWAGE AND WASTES SECTION 8

BY-LAW CONCERNING DISCHARGES AT PURIFICATION WORKS ON THE TERRITORY OF THE URBAN AGGLOMERATION OF MONTRÉAL

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges


National Precast Concrete Association

THE MARSHALL STREET ADVANCED POLLUTION CONTROL FACILITY (CLEARWATER, FLORIDA) CONVERSION TO 4-STAGE BARDENPHO TO IMPROVE BIOLOGICAL NITROGEN REMOVAL

Environmental Technology March/April 1998

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

PROPAK AquaBio Complete Water Restoration Systems

Development of Advanced Wastewater Treatment and Reclamation System

Applications of Advanced Oxidation for Wastewater Treatment

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service


ENVIRONMENTAL ISSUES IN THE RENDERING INDUSTRY. Gregory L. Sindt, P.E. Environmental Engineer Bolton and Menk, Inc.

POLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE

How To Get A Stormwater Discharge Permit In A City Of Scottsdale

Table 1.1: Typical Characteristics of Anaerobically Digested Wastewater

Water Purification Treatment. General Information. Water Purification Treatment Business of the Teijin Group. Water. Purification Treatment

WISCONSIN WASTEWATER OPERATORS ASSOCIATION

TALLINN WATER TREATMENT AND SEWERAGE Tuuli Myllymaa

Application Form 2E. Facilities Which Do Not Discharge Process Wastewater

Regulating Water Pollution in Ontario s Municipalities Windsor s Sewer Use By-law Prepared by Derek Coronado

Facility Classification Standards

UTILITIES DEPARTMENT

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

WATER EFFLUENT AND SOLID WASTE CHARACTERISTICS IN THE PROFESSIONAL CAR WASH INDUSTRY. A Report for the International Carwash Association

Water and Wastewater. Sample Collection and Analysis

CENTRAL POLLUTION CONTROL BOARD Parivesh Bhawan, East Arjun Nagar Delhi

Nutrient Removal at Wastewater Treatment Facilities. Nitrogen and Phosphorus. Gary M. Grey HydroQual, Inc X 7167

To meet our acceptance criteria, we may require you to partially treat your wastewater before it discharges to sewer.

Coagulation and Flocculation

This example of a completed sampling plan worksheet has been included to illustrate the information

Technical Information Paper No

FACT SHEET STATEMENT OF BASIS HARLEY DOME 1 PRODUCED WATER TREATMENT FACILITY UPDES PERMIT NUMBER: UT NEW PERMIT MINOR INDUSTRIAL

Report Naga City: Septage treatment and wastewater concept for Del Rosario

GRUNDFOS BioBooster. Cleaner water Greener environment

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Alberta Environment Standards for Advanced Waste Systems

Phosphorus Removal. Wastewater Treatment

Application for Controlled Trade Waste Discharge Approval

STORMWATER MONITORING: POLLUTANTS, SOURCES, AND SOLUTIONS

DID YOU KNOW... THE IMPACT OF ON-SITE SEWAGE SYSTEMS AND ILLICIT DISCHARGES ON THE ROUGE RIVER

COMPANY PROFILE. AES Company, Head Quarter

Characterizing Beauty Salon Wastewater for the Purpose of Regulating Onsite Disposal Systems

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

Case Study of an Advanced On-Site Wastewater Treatment System Connected to a Single-Family Residence

WEFTEC.06. *Corresponding author Department of Civil and Environmental Engineering, The University of Western Ontario

MATERIAL SAFETY DATA SHEET Description: SAF DRAIN Revision Number: 00

This Questionnaire is divided into 8 sections referring to different capacity areas on the safe use of wastewater in agriculture:

Glossary of Wastewater Terms

SPILL CONTAINMENT AND CONTROL PLAN

California Wastewater

Understanding Septic Tank Systems

I N C O R P O R A T E D

Transcription:

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 1 ENVIRONMENTAL MANAGMENT OF PHARMACEUTICAL WASTES: EXPERIENCE FROM EGYPT Abou-Elela S. I 1, Abou Taleb. E, Ali.M, Badr. N and Abdel Halim. W. 2 1 Water Pollution Research Department, National Research Center, Giza, Egypt 2 Housing and Building National Research Center, Giza, Egypt ABSTRACT Wastewater management in two companies representing the pharmaceutical industry was investigated and implemented. The results showed that the integration of the pollution prevention approach followed by an equalization tank reduced the organic load up to 70%, while further chemical treatment using either alum or ferric chloride aided with lime produced a quality of effluent suitable for restricted irrigation or safe disposal. In the second case study, the implementation of waste minimization approach followed by the construction and implementation of an equalization tank eliminated the needs for the construction of a full-scale treatment plant. All the proposed solutions were documented with cost benefit analysis and engineering designs for implementation. Keywords: Pharmaceutical wastewater, pollution prevention, primary treatment, chemial coagulation. 1. INTRODUCTION Pharmaceutical industry produces hazardous, toxic, and high strength organic liquid wastewater. The most toxic contaminant is antibiotics, analgesic, and antiinflammatory drugs. The presence of these hazardous wastes can cause serious damage to the environment especially surface water, Stackelberg et. al [1]. Recently pharmaceutically active compounds such as liquid-regulating drugs, analgesics, antibiotics, antiseptics, hormones and chemotherapy and beta blocking heart drugs were detected in wastewaters streams and groundwater resources. Pharmaceutically active compounds are mainly ubiquitous at low concentrations in water bodies that receive sewerage treatment plants effluents. Also, the lake of toxicity, information in drinking water standards give rise to concern over the potential of these compounds to occur in drinking water and thus to affect human health through chronic exposures, Sim &Lee [2]. Therefore, control and treatment of such wastes are of potential concern. Pharmaceutical wastewater can be treated using different techniques. Activated sludge was used for different therapeutic groups with diverse physicochemical properties, Horden et. al [3]. Pilot-scale membrane bioreactor exhibited enhanced elimination of several pharmaceutical residues poorly removed by the activated sludge systems, Gros et. al [4]. Solar-Photo-Fenton was studied to be used

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 2 for non-biodegradable drugs. The efficiency of the system was over 95% of which 33% corresponds to the solar photochemical process, Badawy et. al [5]. Advanced oxidation treatment using low pressure UV light coupled with hydrogen peroxide (UV/H2O2) was also evaluated. The removal efficiency varied between no observed removal and 90% depending on the kind of pharmaceutical itself, Rosario et. al [6]. High pressure driven membranes such as nano-filtration membrane and a reverse osmosis membrane are considered to be effective for control and treatment of pharmaceuticals wastewater, Kimura et. al [7]. The enantio selective degradation of pharmaceuticals was evaluated, Sirton et. al [8]. It can be similar under prevailing aerobic and anaerobic conditions. Recently, the antibiotic fermentation wastewater was treated using combined poly ferric sulfate coagulation, Pengxing and Zhisum [9]. Anaerobic treatment of a chemical synthesis based pharmaceutical wastewater in a hybrid up-flow anaerobic sludge blanket (UASB) reactor was taken place lately. The hybrid UASB reactor was found to be more effective at organic loading rate of 8 kg COD/m 3.d with a COD removal efficiency of 72%. It was concluded that this system could be a suitable treatment of chemical synthesis-based pharmaceutical wastewater, Oktem et. al [10]. However, most of the previous stated works were based on laboratory scale for end-of-pipe treatment. Recently, management and in-plant control of industrial wastes is becoming a major concern, Abou-Elela et. al [11]. Due to increasing environmental awareness associated with industrial waste, companies must now incorporate waste management and prevention strategies into industrial process. A wide range of pollution prevention opportunities could be implemented with significant financial advantages for factories, as well as reducing environmental pollution Abou Elela et. al. [12]. Therefore, the aim of this study is the application of any possible low cost/no cost pollution prevention and/or cleaner production technologies for pharmaceutical wastes prior to simple treatment approaches. The proposed solutions were implemented and documented with engineering design and it can be replicated in similar pharmaceutical industry. 2. MATERIAL AND METHODS 2.1 Industrial Auditing The two companies under investigation produce tablets, capsules, ointments, dry and liquid syrups and creams. The first company is located at 6 th of October industrial city, while the other one located in a highly density residential area in Giza Governorate. Both companies discharge their wastewater, without any treatment, into public sewage net work. Before applying any management system,industrial auditing of the two facilities was carried out. It was a systematic review of the different manufacturing processes and operating designs to locate the sources of pollution and identify the quality of wastewater. The audit was to monitor the environmentally damaged activities, compliance with legislation, opportunities for reductions,utilization, waste minimization strategies, effectiveness of existing management

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 3 controls, potential remediation program and pollution prevention measures with relatively short payback periods. 2.2 Sampling Locations and Waste Characterization Collection of composite samples, from different manufacturing departments, and the end of-pipe was carried out on hourly basis as well as during the working shifts. All departmental samples as well as treated effluents were subjected to physicochemical analysis according to APHA (2005). 2. 3 in Plant Control and Treatability Studies 2.3.1 Application of in-plant Control Measures The opportunity of the implementation of any possible in-plant control measures was investigated. This included good housekeeping, reduction of wasted material, minimization of organic load and reuse of wastewater. All the proposed solutions were documented by engineering design for implementation. 2.3.2 Primary Treatment Due to the great variations in the quality and quantity of the end-of-pipe during the three working shifts, design and construction of an equalization tank was recommended as a pre-request for any further treatment. 2.3.3 Post Treatment After applying the in-plant control measures and implementation of an equalization tank, wastewater was subjected to chemical coagulation using different coagulants namely; alum alone or ferric chloride aided with lime. The ph of the end-of-pipe was raised to 10 with lime then it was decreased to ph 8 using FeCl 3.In case of alum, no ph adjustment was carried out since the initial ph of wastewater was around 6.5. Optimum ph and doses of coagulants were investigated using jar test procedure. Schematic diagrams of the proposed management trains for case studies (1) and (2) are shown in Figures (1-2) Raw wastewater waswaswastewa ter In-plant Control Equalization Equalization Disposable into Sewage Network Chemical Coagulation Sedimentation Reuse ewage Network Sludge handling Figure (1): Treatment Train for Case Study (1) Raw wastewater In plant control Equalization Disposal into sewage network Figure (2): Treatment Train for Case Study (2)

mg/l Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 4 3. RESULTS AND DISCUSSION 3.1 Case Study (1) 3.1.1 Characterization of Wastewater Industrial auditing revealed that the main source of wastewater was due to the wash and cleaning of equipments after each batch in the different manufacturing plants. The results obtained in Figure (3) indicated that the main contamination comes from ointment and syrup department due to the cleaning and washing of reaction vessels, using hot water, and prior to any new batch. Average value of chemical oxygen demand (COD) in washing water reached 35950 mg/l with a corresponding average concentration of oil and grease around 2359 mg/l. However, average results of wastewater analysis from research and development department were complying with the Ministerial Decree for wastewater discharge into public sewage network. In addition, the results showed that the end-of-pipe was violating the regulatory standards for wastewater disposal into public sewage network. The average chemical oxygen demand (COD) and biological oxygen demand (BOD) values were 2450 and 1223 mg/l, respectively. 100000 10000 1000 Samples Ointment and syrup Samples End of pipe Samples Research and development 100 10 1 COD BOD TSS Ammonia TKN Oil&grease Soluble sulphides Figure (3): Characteristics of Wastewater from Different Manufacturing Plants during First Shift 3.1.2 Application of in Plant Control Measures 3.1.2.1 Oil and Fat Removal from the Ointment Manufacturing Plant Departmental analysis showed that the main source of pollution was coming from the ointment department during the cleaning process of equipment and manufacturing tanks. The oil and fat content reached 2359 mg/l. Therefore, manual removal of residual fat in the manufacturing tanks was carried out using paper towels followed by rinsing with hot water. This approach reduced the concentration of oil and grease from 2359 mg/l to 480 mg/l. The contaminated towels were collected and sent off site for safe disposal. The other source of pollution was the accumulation of fat on the surface of different manholes in the company. Regular cleaning for all manholes in the company was highly recommended. Application of the in plant control measure removed up to 79% of COD, 70% of BOD and 69% of oil and grease in the wastewater from ointment department as shown in Table (1) and Figure (4).

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 5 Table (1): Application of in-plant Control Measures in Ointment Production Plant Parameters Units Before inplant control After in-plant control % Removal PH 6.5 6.6 COD mgo 2 /l 35950 7625 79 BOD mgo 2 /l 12000 3633 70 TSS mg/l 660 488 26 Total settle mg/l 1.6 0.85 47 able solids (10 min) Total settle mg/l 3.5 0.87 75 able solids (10 min) Ammonia mgn/l 2.8 5.8 TKN mgn/l 49.3 35 70 T.P mgp/l 7 2 71 Oil & Grease mg/l 2359 480 69 Figure (4): Application of in-plant Control Measures in Ointment Department 3.1.2.2 Characterizations of Composite Wastewater Samples during the Whole Day In order to get concrete performance for the quality of the end-of-pipe, composite samples were collected and analyzed during 24 hrs operation.the results obtained in Table (2) indicated that the parameters under consideration namely; COD, BOD, total suspended solids(tss),total kjeldahl nitrogen(tkn ) and total phosphorus(t.p) were complying with wastewater discharge into public sewage network. Corresponding residual average values were 574, 343, 81 and 2.2 mg/l. This indicated the need of an equalization tank. Table (2): Characteristics of End-of-Pipe during 24 Hours Operation Parameters End-of-pipe (24 hours samples) Ministerial Min Max Average Decree 44/2000 ph 6.3 7.2 6-9 COD 305 832 573.7 1100 BOD 280 450 343.3 600 TSS 46 103 81.3 800 Ammonia 6.7 28 11.2 25 TKN 16.3 61.5 23.7 100 T.P 0.2 4.6 1.2 25

mg/l Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 6 3.1.2.3 Equalization The objective of equalization of flow is to minimize or control fluctuations in wastewater characteristics in order to provide optimum conditions for subsequent treatment processes, also to provide capacity for controlled discharge of wastes to municipal system in order to distribute waste loads more evenly. Therefore, design, construction, and implementation of an equalization tank were carried out. The volume of the tank was 18 m 3 and the working hours /day was 5hrs.A schematic diagram of the proposed equalization tank is shown in Figure (5). Figure (5): Schematic Diagram of Equalization Tank 3.1.3 Chemical Coagulation-Sedimentation In order to improve the quality of the end-of-pipe for possible reuse in restricted irrigation within the facility, chemical treatment of the effluent from equalization tank was subjected to chemical treatment, using different coagulants. The coagulants used were ferric chloride aided with lime (Ferrite method), while the second coagulant was alum. The average doses of lime, ferric chloride and alum were 240, 182 and 300 mg/l, respectively. The obtained results are shown in Figure (6). The percentage removal values of COD, BOD, and TSS were 75.4, 74.3, and 96.5, respectively when ferrite method was used. Better removal values were achieved when alum was used. Removal rates of COD, BOD and TSS were 84,94,and 96 %. However, ferric chloride aided with lime was recommended due to the quality of the sludge produced, which was more stable and settled easily compared with the sludge produced from alum. A schematic diagram of the proposed chemical treatment unit is shown in Figure (7) 700 Equalization Tank 600 500 FeCl3+lime Alum 400 300 200 100 0 COD BOD TSS Figure (6): Residual concentration of COD, BOD, and TSS in the Chemically Treated Effluent

mg/l Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 7 Figure (7) Schematic Diagram of the Chemical Treatment Unit 3.1.4 Overall Efficiency of the Management System for Case Study (1) Average overall efficiency of the control and treatment of wastewater in the first company is shown in Figure (8). TSS was almost removed, while the COD and BOD percentage removals were 92.3 and 92.8 %, respectively. 3000 Raw wastewater 2500 2000 1500 Inplant control Equalization (24) Equalization followed by chemical treatment 1000 500 0 COD BOD TSS 3.2 Case Study (2) Figure (8): Efficiency of the Proposed Management System This is a very old and huge company located in a highly populated residential area. The number of employees is 3000, distributed in three shifts. Wastewater discharged from the company (500 m 3 /day) was highly contaminated with organic matters as presented by COD, BOD and fats. 3.2.1 Sources of Pollution in the Company From the plant survey, it was found that the main sources of pollution are: Maintenance of cars and buses, washing of cars and changing oil in garage. Washing of manufacturing equipments and mixing tanks after each batch.

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 8 Floor washing and open circuit cooling water. Municipal wastewater. The results showed that the cream department and the garage are the primary sources of pollution.the concentration of oil & grease and COD reached 2272 mg/l, 9612 mgo 2 /l in cream department.in addition it reached 966 mg/l, 4126 mgo 2 /l in the garage. Accordingly, it was found necessary to remove fats and grease prior to any further treatment. 3.2.2 Application of Pollution Prevention and in-plant Control Measures 3.2.2.1 Oil Removal from Garage Plant survey indicated that bad housekeeping occurred at this site. Great seepage and spill of oil on the floor took place. Moreover, changeable oil was dumped in an open channel connected to an existing on-site payara. In addition, the washing water of cars and buses were contaminated with oil, detergent and suspended solids. These oily wastes reached the final effluent and aggravated the pollution load. Therefore, two approaches for minimizing oil wastewater were carried out. First approach: is the elimination of the open channel and collecting the changeable oil in barrels for sale. Second approach: Design, construction, and implementation of oil trap chamber within the site as shown in Figure (9). Assembling of floated oil was done at the end of the shift; then the amount collected in barrels 20 liters capacity and sent to the Petroleum Company for re- use. Periodical oil & fat removal from the manhole of the end-of-pipe Figure (9) Oil Trap Chamber

mg/l Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 9 These solutions reduced the oil & fat and COD concentrations in the garage site by 97.05%, 98.17% respectively. 3.2.2.2 Minimization of Fat Contamination in Washing Water of Equipments and Reaction vessels of Ointments & Cream The manufacturing equipments and machines are washed with hot water after each batch. To minimize the fat concentration in washing water, cleaning of residual fat was carried out by using rolls of paper to remove residual ointments then assembled prior to safe disposal in a sanitary landfill. This was followed by hot water cleaning. By implementing this approach the organic load represented by COD and BOD were decreased from 9612, 5382 mgo 2 /l to 1063, 606 mgo 2 /l, while the concentration of oils and grease reduced from 2272 to 276 mg/l with a percentage removal of 87.85%. 3.2.2.3Control and Safe Disposal of Refused and Expired Medicines The rejected medicines either liquids or solids were dumped directly to the sewage network which cause sudden chock loads to the sewage network. This problem was overcome by segregation and collection of either liquid or solids rejected medicine in separate tanks. These wastes are currently send to the Egyptian Cement Company, for safe disposal and destruction. 3.2.2.4Equalization Composite samples collected during the working shifts on hourly basis indicated that the quality of the wastewater varied from hour to hour and even from shift to shift (Figure10).Therefore, it was found necessary to equalize the flow before final discharge. Figure (11) illustrate the engineering design of the proposed model of equalization tank. 3.2.2.5Overall Efficiency of the Management System for Case Study (2) Application of in-plant control measures followed by equalization tank produced an effluent complying with the National Regulatory Standards and eliminated the needs for construction of a full-scale treatment plant as shown in Table (3). 1800 1600 1400 1200 1000 800 600 400 200 0 1 2 3 4 5 6 7 8 9 10 11 12 No of samples during working shifts Figure ( ) Variation of COD,TSS, Turbidity during three working shifts Turbidity NTU Chemical oxygen demand /l2mgo Figure (10) Variation of COD, TSS, turbidity during three working shifts

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 10 Figure (11) Schematic Diagram of Equalization Tank, Case Study (2) Table (3) Characterization of Wastewater after Applying Management System Parameters Unit Final Effluent Ministerial Decree 44/2000 ph- value -- 6.1 6-9 Turbidity NTU 130 --- Chemical oxygen demand mgo 2 /l 470 1100 Biological oxygen demand mgo 2 /l 205 600 Total Suspended Solids mg/l 185 800 Oil & grease mg/l 38 100 4. CONCLUSIONS Application of in-plant control measures prior to treatability studies reduces the organic load as represented by COD and BOD by 78, 69.7%, respectively. By applying the in-plant control measures followed by the implementation of an equalization tank produced a quality of effluent complying with the National Regulatory Standards for wastewater discharge into public sewage network. Moreover chemical treatment using ferric chloride aided with lime after in-plant control and equalization resulted in an effluent suitable for reuse in restricted irrigation. The removal efficiencies of COD, BOD and TSS reached 98.7%, 92.3 % and 92.8%, respectively. REFERENCES [1] Stackelberg P. E., Furlong E. T., Meyer M. T., Zaugg S. D., Henderson A., Reissman D. B., Persistence of pharmaceutical compounds and other organic wastewater contaminants in a conventional drinking water treatment plant, Journal Science of the total environment, 329 (2004), pp 99-113.

Sixteenth International Water Technology Conference, IWTC 16 2012, Istanbul, Turkey 11 [2] Sim W.J., Lee J.W., Oh J.E., Occurrence and fate of pharmaceuticals in wastewater treatment plants and rivers in Korea, Environmental pollution 158, (2010), pp 1938-1947. [3] Horden B.K., Dinsdale R.M., Guwy A.J., The removal of pharmaceuticals, personal care products endocrine disruptors and illicit drugs during wastewater treatment and its impact on the quality of receiving waters,, Water research,43 (2009), pp 363-380. [4] Gros M., Ginebreda M., Barcelo D., Removal of pharmaceuticals during wastewater treatment and environmental assessment using hazard indexes, Environmental international, 36 (2010), pp 15-25. [5] Badawy M.I., Abdel-Wahaab R., Kalliny A.S., Fenton-biological treatment process for the removal of some pharmaceuticals from industrial wastewater, Journal of Hazardous materials, (2009), pp 567-574. [6] Rosario-Orhz F., Wert E.C., Snyder S.A., Evaluation of UV/H 2 O 2 treatment for the oxidation of pharmaceuticals in wastewater, Water research 44 (2010), pp 1440-1448. [7] Kimura K., Iwase T., Keta S., Watanabe Y. Influence of residual organic macromolecules produced in biological wastewater treatment processes on removal of pharmaceuticals by NF/RO membranes, Water research 43 (2009), pp 3751-3758. [8] Sirton C., Zapata A., Oller I., Gernjak W., Aguera A., Malats Decontamination of industrial pharmaceutical wastewater by combining solar-photo-fenton and biological treatment, Water research 43 (2009), pp 661-668. [9] Pengxing Zi, Zhisum De, Poly ferric treatment of antibiotic fermentation wastewater by combine of sulfate coagulation, Fenton and sedimentation Process, Journal of Hazardous Materials, (2009), pp 1264-1268. [10] Abou-Elela S.I, Fayza A. Nasr, Hanan S Ibrahim. Nagwa M. Badr, Askalany M, Pollution prevention pays off in a board paper mill Journal of Cleaner Production,16, 2008, pp 330-334. [11] Abou-Elela S. I. and Zaher,F., Pollution prevention in oil and soap industry Case study,wat.sci.tec.,vol.38, (1998) pp.139-144. [12] Oktem Y.A., Ince O., Donnelly P., Ince B.K., Anaerobic treatment of a chemical synthesis pharmaceutical wastewater in a hybrid up flow anaerobic sludge blanket reactor. Bio resource technology, 99 (5), (2008), pp 1089-1096. [13] Standard methods for the examination of water and wastewater, APHA, WPCF, 2005.