Here to Support You. with Your Clinical Research. Personalized Support. Take Advantage of Our Lab. 24 Hour Access to Information. Technical Database



Similar documents
Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Oasis HLB Cartridges and 96-Well Plates

Improved Method for the Analysis of 31 Drugs of Abuse in Oral Fluid samples using the Thomson extreme FV by LC-MS/MS

AppNote 6/2011. Determination of Pain Management Drugs using Automated Disposable Pipette Extraction and LC-MS/MS KEYWORDS ABSTRACT

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Toxicology CPT Code Changes for 2016

Opiates in Urine by SAMHSA GC/MS

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Innovative vs Traditional

Simultaneous Quantitation of 78 Drugs and Metabolites in Urine with a Dilute-And-Shoot LC MS-MS Assay

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Advances in Steroid Panel Analysis with High Sensitivity LC/MS/MS. Kenneth C. Lewis 1, Lisa St. John-Williams 1, Changtong Hao 2, Sha Joshua Ye 2

SOLID PHASE EXTRACTION APPLICATIONS MANUAL

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Purification of reaction mixtures using flash chromatography.

Collection Instructions for ARUP Drug Screen Kit #49204

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

CORESTA RECOMMENDED METHOD N 72

AppNote 4/2014. Prep-and-Shoot : The Completely Automated Workfl ow for the Hydrolysis and Analysis of Urine Samples by LC/MS/MS.

How To Test For Contamination In Large Volume Water

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Tamsulosin Hydrochloride Capsules

A Novel Approach to Low Volume Sample Preparation

An In-Gel Digestion Protocol

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Overview. Purpose. Methods. Results

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Unique Bonding Chemistry

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Detection of Estrogens in Aqueous and Solid Environmental Matrices by Direct Injection LC-MS/MS

Genomic DNA Extraction Kit INSTRUCTION MANUAL

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Sample Preparation Using Solid Phase Extraction

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Determination of Tapentadol and its Metabolite N

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Solid Phase Extraction for Water Analysis. presented by

Epinephrine/Norepinephrine ELISA Kit

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

RealLine HCV PCR Qualitative - Uni-Format

Introduction. Methods. Sample Processing

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Protocol: HPLC (amino acids)

METHOD OF ANALYSIS. N methyl 2-pyrrolidone

Practical Aspects of Drug Testing in Human Hair

LC-MSMS - state of the art in endocrinology

Successful Sample Preparation Strategies for LC/MS/MS Analysis of Drugs in Complex Biological Matrices for Forensic Toxicology Applications

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

DUI in Southern Ohio MATT 2006

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

HiPer Ion Exchange Chromatography Teaching Kit

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

ORGANIC SAMPLE PREPARATION

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

UltraClean PCR Clean-Up Kit

Transcription:

Application Guide CLINICAL RESEARCH Complete solutions for vitamins, steroids, hormones, pain management drugs, therapeutic drug monitoring, and more Simplified, rapid cleanup procedures Accurate, reproducible results

Here to Support You with Your Clinical Research Personalized Support Your lab has its very own Technical Consultant that is available to assist with method development, optimization, troubleshooting, and product recommendations. Feel free to give them a call with any questions you may have! Get to Know Your Technical Consultant Support@phenomenex.com Take Advantage of Our Lab Our customers asked us for more support, we responded with PhenoLogix sm, a full-service analytical support laboratory. Let our PhenoLogix clinical research gurus save your lab time and money. Method development and optimization in our PhenoLogix laboratory On-site method development On-site hands-on training Explore PhenoLogix www.phenomenex.com/phenologix 24 Hour Access to Information Technical Database Access our vast database of technical notes, applications, webinars, and more. Search by industry, document type, and separation mode to easily find what you need. www.phenomenex.com/mylinks Tools Utilize our web tools to find product recommendations, create customized methods, and more. www.phenomenex.com/tools For Research Use Only. Not for use in diagnostic procedures. 214 Phenomenex, Inc. All rights reserved.

TABLE OF CONTENTS Steroids/Hormones and Related Compounds Aldosterone...4 Catecholamines...5 Corticosteroids...6-7 Estrogens...8-9 Histamine...1 Metanephrine and Normetanephrine...11 17-OH Progesterone...12-1 Steroids Panel...14-15 Testosterone...16 Therapeutic Drug Monitoring Antiepileptic Drugs...17 Antipsychotic Drugs...18 Digitoxin and Digoxin...19 Gabapentin...2 Tricyclic Antidepressants...21 Pain Panel/Pain Management Drugs Pain Panel...22-2 Amphetamines...24 Benzodiazepines...25 Opiates...26 Vitamin Testing 25-OH Vitamin D2 and D...27 25-OH Vitamin D and -epi-25-oh Vitamin D...28 Methylmalonic Acid (MMA)...29 Vitamin B6... Vitamin C...1 Forensic/Drugs of Abuse Nicotine and its Metabolites...2 Bath Salts... Ordering Information Sample Preparation...2-7 HPLC/UHPLC Columns...8-4 Looking for something else? Let us know, we can help you find a solution. By email: Support@phenomenex.com Phenomenex l WEB: www.phenomenex.com

Steroids/Hormones and Related Compounds Aldosterone from Serum Sample Preparation Pretreatment: Into individually labeled test tubes, combine.5 ml serum (or calibrator or QC sample), 1 ml 25 mm Ammonium bicarbonate (ph 8.9-9.), and.1 ml working internal standard solution. Solid Phase Extraction (SPE): Cartridge: Strata -X-A 6 mg/ ml Part No.: 8B-S12-UBJ (see pg. 5 for additional formats) Condition: ml 1 % Methanol Equilibrate: ml 25 mm Ammonium bicarbonate Load: Pretreated sample Wash 1: ml 25 mm Ammonium bicarbonate Wash 2: ml 25 % Methanol in Water Dry: 5 min at high vacuum Elute: 2x 1 ml Ethyl acetate/isopropanol/nh 4 OH (7:2:1) Evaporate: To dryness @ 5-55 C under a gentle nitrogen stream Reconstitute: 1 µl Methanol/Water (:7) containing ~1 ppm Estriol 29 1.e4 1.2e4 1.1e4 1 LC/MS/MS Conditions: Column: Kinetex 2.6 µm XB-C18 Dimension: 5 x. mm Part No.: B-4496-Y Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8775 Mobile Phase: A: Water B: Acetonitrile/Methanol (5:5). 4. 5. 5.1 7. 9 9 Flow Rate:.5 ml/min Column Temperature: 22 C Injection Volume: µl Detection: MS/MS (AB SCIEX API 5 ) Sample: 1. Aldosterone 2. Aldosterone-D7 1e4 9 8 7 6 2 5 4 2 1 App ID 29.5 1 1.5 2 2.5.5 4 4.5 5 5.5 6 6.5 min Representative calibration curve for Aldosterone. The method was linear across the concentration range of 1-1 ng/dl. 11 1 Analyte Q1 Q2 Aldosterone 1 59.1 189. Aldosterone 2 59.1 1.1 IS (Aldosterone-D7) 66.1 194.1 9 Analyte Area / IS Area 8 7 6 5 4 r=.999 2 5 1 15 2 25 5 4 45 5 55 6 65 7 75 8 85 9 95 1 ng/dl 4

Steroids/Hormones and Related Compounds Catecholamines by LC/UV 1874 mau 12 1 8 6 1 2 4 5 LC/UV Conditions: Column: Kinetex 2.6 µm C18 Dimension: 15 x 4.6 mm Part No.: F-4462-E Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8768 Mobile Phase: 5 mm Ammonium formate buffer (ph )/Methanol (97:) Flow Rate: 1.2 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: UV-Vis @ 28 nm Sample: 1. Norepinephrine 2. Epinephrine. L-DOPA 4. Dopamine 5. Serotonin 4 2 App ID 1874 2 4 6 min 8 1 12 5

Steroids/Hormones and Related Compounds Corticosteroids from Urine Sample Preparation Pretreatment: Dilute µl urine with µl DI Water with 1 µg IS (Cortisol-D4). Solid Phase Extraction (SPE): 96-Well Plate: Strata -X 6 mg/well Part No.: 8E-S1-UGB (see pg. 5 for additional formats) Condition: 1 ml Methanol Equilibrate: 1 ml Water Load: Pretreated sample Wash 1: 1 ml Water Wash 2: 1 ml 1 % Methanol in Water Elute: 2x 5 µl 2 % Formic acid in Ethyl acetate/isopropanol (85:15) Evaporate: To dryness @ 5 C under a gentle nitrogen stream Reconstitute: 1 µl Ammonium acetate/ammonium acetate in Methanol (5:5) LC/MS/MS Condtions Column: Kinetex 2.6 µm Biphenyl Dimensions: 5 x. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-928 Mobile Phase: A: 1 mm Ammonium acetate in Water B: 1 mm Ammonium acetate in Methanol.1.5 2...1 5. 4 4 9 9 4 4 Flow Rate:.4 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX API 4 ), ESI+ 6

Steroids/Hormones and Related Compounds 22169 7e5 6e5 5e5 4e5 e5 2e5 1e5 1. Prednisolone 2. Prednisone 2217.5 1 1.5 2 2.5.5 4 4.5 min 1 2 App ID 22169 Analyte Q1 Q Cortisone 1 61 16 Cortisone 2 61 121 Cortisol 1 6 121 Cortisol 2 6 9 Prednisolone 1 61 147 Prednisolone 2 61 17 Prednisone 1 59 147 Prednisone 1 59 27 Cortisol-D4 1 67 121 Cortisol-D4 2 67 1 4 1e6. Cortisol 8e5 4. Cortisone 6e5 4e5 2e5.5 1 1.5 2 2.5.5 4 4.5 min App ID 2217 4.4e5 4.2e5 4.e5.8e5.6e5.4e5.2e5.e5 2.8e5 2.6e5 2.4e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4. 1. Prednisolone 1. Prednisolone 2. Cortisone 2. Cortisone 2 1.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8..2.4.6.8 4. min 4.4 4.6 4.8 App ID 22678 4.2 Representative 22164 calibration curve for Cortisol. The method was linear across the concentration range of 1-2 ng/ml. 2.4 2.2 2. r =.9998 1.8 Analyte Area / IS Area 1.6 1.4 1.2 1..8.6.4.2 2 4 6 8 1 12 14 16 18 2 ng/ml 7

Steroids/Hormones and Related Compounds Estrogens Estrone and Estradiol LC/MS/MS Conditions 265 Estrone Estrone-D4 Estradiol Estradiol-D App ID 265 Column: Gemini µm NX-C18 Dimension: 5 x 2. mm Part No.: B-445-B Guard: SecurityGuard guard cartridge system Part No.: AJ-867 Mobile Phase: A:.5 mm Ammonium hydroxide in Water B:.5 mm Ammonium hydroxide in Methanol..5 2.5 5. 5.2 6. 1 1 8 9 1 1 Flow Rate:.55 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 4 ), ESI - Sample: 1. Estrone 2. Estrone-D4. Estradiol 4. Estradiol-D Analyte Q1 Q Estrone 269.1 145 Estradiol 271.12 145.1 Estrone-D4 (IS) 27.1 147.2 Estradiol-D (IS) 274.1 145.1 8

Steroids/Hormones and Related Compounds Estrogens Estriol LC/MS/MS Conditions 2654 28 26 24 22 2 18 16 14 12 1 8 6 4 2 2.8 Estriol 28 26 24 22 2 18 16 14 12 1 8 6 4 2 2.9.1.2. min 2.8 Estriol-D App ID 2654 2.9.1.2. min Column: Gemini µm C6-Phenyl Dimension: 5 x 2. mm Part No.: B-444-B Guard: SecurityGuard guard cartridge system Part No.: AJ-7914 Mobile Phase: A:.1 % 5. N Ammonium hydroxide in Water B:.1 % 5. N Ammonium hydroxide in Methanol..5.5 5. 5.1 6. 2 2 9 9 2 2 Flow Rate:.5 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 4 ), ESI - Sample: 1. Estriol 2. Estriol-D Analyte Q1 Q Estriol 287.6 171.1 Estriol-D 172.2 17.2 9

Steroids/Hormones and Related Compounds Histamine from Plasma Sample Preparation Pretreatment: Add 1.1 ml IS solution containing 4 ng/ml histamine-d4 and 1-methylhistamine-d prepared in DI water to 5 µl sample, blank, or plasma. Solid Phase Extraction (SPE): Cartridge: Strata -X-CW mg/ ml Part No.: 8B-S5-TBJ (see pg. 5 for additional formats) Condition: 1 ml 1 % Methanol Equilibrate: 1 ml DI Water Load: Pretreated sample Wash 1: 2 ml DI Water Wash 2: 2 ml Methanol Dry: 2 min at high vacuum Elute: 2x 25 µl initial mobile phase containing B/A (87:1), fortified to contain 5 % Formic acid LC/MS/MS Conditions Analyte Area / IS Area 4.e4 2.6e4.2e4 2.8e4 2.4e4 2.e4 1.6e4 1 1.2e4 8. 4..5 1. 1.5 2. 2.5..5 min 1.4e4 1.2e4 1.e4 8. 6. 4. 2. 7. 5. 89. 85 1. 8 75.5 1. 1.5 2. 2.5..5 min 7 65 6 55 5 45 4 5 25 2 15 1 5 1.5 1. 1.5 2. 2.5..5 min 4.e4 2.6e4.2e4 2.8e4 2.4e4 2.e4 1.6e4 1.2e4 8. 4..5 1. 1.5 2. 2.5..5 min 1.e4 9. 1 Representative 1.1e4 calibration curve for Histamine. The method was linear across a concentration range of.1-5 ng/ml. 5 1 15 2 25 5 4 45 ng / ml r =.999 App ID 265 Column: Luna µm HILIC Dimension: 1 x 2. mm Part No.: D-4449-B Guard: SecurityGuard guard cartridge system Part No.: AJ-828 Mobile Phase: A: Acetonitrile/DI Water/1 mm Ammonium formate, ph.2 (5:45:5) B: Acetonitrile/1 mm Ammonium formate, ph.2 (95:5). 1.5 2.5 2.6 4.5 8 8 8 Flow Rate:.6 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 5 ) Sample: 1. 1-Methylhistamine 2. N-Methylhistamine. Histamine Analyte Q1 Q Histamine 1 112.1 95. Histamine 2 112.1 68. 1-Methylhistamine 1 126.1 19. 1-Methylhistamine 2 126.1 96.9 N-Methylhistamine 1 126.1 95. N-Methylhistamine 2 126.1 68.1 Histamine-D4 116.1 68.1 Methylhistamine-D 129.1 68.1 1

Steroids/Hormones and Related Compounds Metanephrine and Normetanephrine from Plasma Sample Preparation Pretreatment: Dilute 5 µl plasma with 1 ml water. Solid Phase Extraction (SPE): Cartridge: Strata -X-CW mg/ ml Part No.: 8B-S5-TBJ (see pg. 5 for additional formats) Condition: 4 µl Methanol/Acetonitrile (5:5) Equilibrate: 4 µl DI Water Load: Pretreated sample Wash 1: 8 µl DI Water Wash 2: 2 ml Methanol/Acetonitrile (5:5) Dry: 2 min at high vacuum Elute: 2x 2 µl 5 % Formic acid in Acetonitrile/Methanol (5:5) Evaporate: To dryness @ 45 C under a gentle nitrogen stream Reconstitute: 1 µl Acetonitrile/1 mm Ammonium formate, ph.2 (95:5), cap immediately to prevent evaporation LC/MS/MS Conditions Intens ity, c ps Intens ity, c ps 7.8e4 7.e4 6.e4 5.e4 4.e4.e4 2.e4 1.e4 7.8e4 7.e4 6.e4 5.e4 4.e4.e4 2.e4 1.e4 1 2.5 1. 1.5 1 2 4 5 min 4 2. 2.5..5 4. 4.5 5. 5.5 min Metanephrine-D Intens ity, cps 4.e4.5e4.e4 2.5e4 2.e4 1.5e4 1.e4 5. Normetanephrine-D 1 2 4 5 min Column: Luna µm HILIC Dimension: 5 x 2. mm Part No.: B-4449-B Guard: SecurityGuard guard cartridge system Part No.: AJ-828 Mobile Phase: A: Acetonitrile/1 mm Ammonium formate, ph.2 (95:5) B: Acetonitrile/Water/1 mm Ammonium formate, ph.2 (5:45:5). 2.51.1 6. 1 Flow Rate:.4 ml/min Column Temperature: 22 C Injection Volume: µl Detection: MS/MS (AB SCIEX API 5 ) Sample: 1. Metanephrine 2. Metanephrine-D. Normetanephrine 4. Normetanephrine-D Inte nsity, c ps 5578 5 4 2 1 Metanephrine 1 2 4 5 min Intens ity, cp s 1955 18 16 14 12 1 8 6 4 2 Normetanephrine 1 2 4 5 min App ID 1797 Analyte Q1 Q Metanephrine 18.4 148.2 Metaneprhine-D 18.4 151.2 Normetanephrine 166.4 14.2 Normetanephrine-D 169.4 17.2 11

Steroids/Hormones and Related Compounds 17-OH Progesterone from Serum Sample Preparation Pretreatment: Dilute.25 ml of sample with 1 ml DI Water and.1 ml IS solution (1 ng/ml Testosterone-D and ng/ml 17-OH-Progesterone-D8 in Methanol/DI Water (5:5). Solid Phase Extraction (SPE): Cartridge: Strata -X-A mg/1 ml Part No.: 8B-S12-TAK (see pg. 5 for additional formats) Condition: 1 ml 1 % Methanol Equilibrate: 1 ml DI Water Load: Pretreated sample Wash: 6 µl 5 % Methanol Dry: 2 min at high vacuum Elute: 2x 6 µl 1 % Methanol Evaporate: To dryness @ 5-55 C under a gentle nitrogen stream Reconstitute: 25 µl 2 % Acetonitrile in.1 % Formic acid 12

Steroids/Hormones and Related Compounds LC/MS/MS Conditions 2652 2.4e4 2.2e4 2.e4 1.7e4 1.6e4 1.4e4 1.2e4 1.e4 8 6 4 2 1 2.5 1 1.5 2 2.5.5 4 min 4.5 min App ID 2652 Column: Gemini µm NX-C18 Dimension: 5 x 2. mm Part No.: B-445-B Guard: SecurityGuard guard cartridge system Part No.: AJ-867 Mobile Phase: A:.1 % Formic acid in DI Water B:.1 % Formic acid in Acetonitrile. 2.5 4.5 4.6 6. 2 75 75 2 2 Flow Rate:.4 ml/min Column Temperature: 22 C Injection Volume: 25 µl Detection: MS/MS (AB SCIEX API 4 ) Sample: 1. Testosterone 2. 17-OH Progesterone Analyte Q1 Q 17-OH-Progesterone 1 1. 97.2 17-OH-Progesterone 2 1. 19.2 17-OH-Progesterone-D8 1 9. 1.1 17-OH-Progesterone-D8 2 9. 11.2 Representative calibration curve for 17-OH Progesterone. The method was linear across the concentration range of 1-1, pg/ml. 1 9 8 7 Analyte Area / IS Area 6 5 4 r =.9988 2 1 1 2 4 5 6 7 8 9 1.e 4 pg / ml 1

Steroids/Hormones and Related Compounds Steroids Panel LC/MS/MS Conditions 2655 1.8E6 1 2 7 1.6E6 1 1.4E6 1.2E6 1.E6 8.E5 8 6.E5 4.E5 2.E5 4 5 6 9 11 App ID 2655 4 5 6 7 8 9 1 11 12 min Column: Kinetex 2.6 µm C18 Dimension: 1 x. mm Part No.: D-4462-Y Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8775 Mobile Phase: A: Water B: Methanol. 2.. 7. 1. 1.2 1. 1.2 16. 1 1 4 7 8 95 95 1 1 Flow Rate:.55 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 4 ) Sample: 1. DHEAS 2. Cortisol. Corticosterone 4. 11-Deoxycortisol 5. Androstenedione 6. Estradiol 7. Testosterone 8. 17-OH Progesterone 9. DHEA 1. Progesterone 11. 25-OH Vitamin D 14

1. 2.. 4. 5. 6. 7. 8. 9. 1. 11. 12. 1. 14. 15. 16. 17. 18. 19. 2. Steroids/Hormones and Related Compounds Analyte Q1 Q Q DHEAS 271.1 21.1 25.2 Cortisol 6.1 115.1 121. Corticosterone 47.1 121.1 91. 11-Deoxycortisol 47.1 97. 19. Androstenedione 287.1 19. 97.1 Estradiol (water loss) 255.1 144. 159.1 Testosterone 289. 19. 97. 17-OH Progesterone 1. 97. 19. DHEA 271.2 21.1 25.2 Progesterone 15.1 19. 97. 25-OH Vitamin D 8. 91. 65. Representative calibration curves for Testosterone, 17-OH Progesterone, Progesterone, and Estradiol. The method was linear across a concentration range of.1-2. ng/ml. 22. 21. r =.9969 2.9 2.8 r =.996 2. 2.6 19. 18. 17. Testosterone 2.4 2.2 17-OH Progesterone 16. 2. Analyte Area / IS Area 15. 14. 1. 12. 11. 1. 9. 8. 7. 6. 5. 4. % CV < 7.56% % accuracy > 94.% Analyte Area / IS Area 1.8 1.6 1.4 1.2 1..8.6 % CV < 9.8% % accuracy > 94.6%..4 2..2 1... 1. 2.. 4. 5. 6. 7. 8. 9. 1. 11. 12. 1. 14. 15. 16. 17. 18. 19. 2. ng/ml ng/ml 18. 2.8 17. 16. r =.9981 2.6 2.4 r =.9951 15. 14. 1. Progesterone 2.2 2. Estradiol Analyte Area / IS Area 12. 11. 1. 9. 8. Analyte Area / IS Area 1.8 1.6 1.4 1.2 7. 1. 6. 5. 4.. % CV < 8.45% % accuracy > 94.4%.8.6.4 % CV < 9.88% % accuracy > 94.2% 2. 1..2.. 1. 2.. 4. 5. 6. 7. 8. 9. 1. 11. 12. 1. 14. 15. 16. 17. 18. 19. 2. ng/ml 1. 2.. 4. 5. 6. 7. 8. 9. 1. 11. 12. 1. 14. 15. 16. 17. 18. 19. 2. ng/ml 15

Steroids/Hormones and Related Compounds Total Testosterone from Plasma Sample Preparation Pretreatment: Dilute.25 ml of sample with 1 ml DI Water and.1 ml IS solution (2 ng/ml Testosterone-D in methanol). Solid Phase Extraction (SPE): Cartridge: Strata -X-A mg/ ml Part No.: 8B-S12-TBJ (see pg. 5 for additional formats) Condition: 1 ml 1 % Methanol Equilibrate: 1 ml DI Water Load: Pretreated sample Wash 1: 6 µl 5 % Methanol Dry: 2 min at high vacuum Elute: 2x µl 1 % Methanol Evaporate: To dryness @ 5-55 C under a gentle nitrogen stream Reconstitute: 5 µl 25 % Hydroxylamine to form oxime and heat for 2844 5-6 min at 6-65 C then add 2 µl 5 % Formic acid in DI Water.6e5.4e5.2e5.e5 2.8e5 2.6e5 2.4e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2 1 LC/MS/MS Conditions Column: Gemini µm NX-C18 Dimension: 5 x 2. mm Part No.: B-445-B Guard: SecurityGuard guard cartridge system Part No.: AJ-867 Mobile Phase: A: 1 mm Ammonium formate in Water with.1 % Formic acid B: 1 mm Ammonium formate in Acetonitrile with.1 % Formic acid. 1.5 2.5 2.6 5. 2.e4.5 1. 1.5 2. 2.5..5 4. 4.5 min 9 9 Flow Rate:.4 ml/min Column Temperature: 5 C Injection Volume: 25 µl Detection: MS/MS (AB SCIEX API 5 ) Sample: 1. Testosterone 2. Testosterone-D. Epitestosterone App ID 2844 Representative calibration curve for Testosterone. The method was linear across the concentration range 1-1 ng/dl. 59 55 5 Analyte Area / IS Area 45 4 5 25 2 Analyte Q1 Q Testosterone 1 4. 124. Testosterone 2 4. 112. Testosterone-D 1 7. 112. Testosterone-D 2 7. 124. 15 1 5 1 2 4 5 6 7 8 9 1e4 ng/dl Note: the quantitation is based on the testosterone-oxime derivative See Performance Characteristics of a Novel Tandem Mass Spectrometry Assay for Serum Testosterone. Kushnir, Mark M, et. al. ARUP Institute for Clinical and Experimental Pathology, Salt Lake City, UT 8418, USA. Clin Chem 52:12-8. 26 Jan. Therapeutic Drug Monitoring 16

Therapeutic Drug Monitoring Antiepileptic Drugs LC/MS/MS Conditions 22155 4.e5.8e5.6e5.4e5.2e5.e5 2.8e5 2.6e5 2.4e5 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4. 1 1 2 2 4 5 6 7 4 App ID 22155 min Column: Kinetex 2.6 µm Biphenyl Dimension: 5 x 2.1 mm Part No.: B-4462-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-929 Mobile Phase: A: Water with.1 % Formic acid B: Methanol with.1 % Formic acid...1 6. 2. 95 2. 2. Flow Rate:.5 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX Triple Quad 45) Sample: 1. Pregabalin 2. Gabapentin. Levetiracetam 4. Lamotrigine 5. Zonisamide 6. Lacosamide 7. MHD 17

Therapeutic Drug Monitoring Antipsychotic Drugs LC/MS/MS Conditions 22154 6.2e5 6.e5 6 5.5e5 5.e5 4.5e5 4.e5.5e5.e5 2.5e5 2 4 2.e5 1.5e5 1.e5 5.e4 1 5 7 8 App ID 22154. 1 1 2 4 min Column: Kinetex 2.6 µm Biphenyl Dimension: 5 x 2.1 mm Part No.: B-4462-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-929 Mobile Phase: A: Water with.1 % Formic acid B: Methanol with.1 % Formic acid. 5. 5.1 5. 95 5. Flow Rate:.5 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX Triple Quad 45) Sample: 1. Olanzapine 2. Clozapine. 9-OH-Risperidone 4. Risperidone 5. Norquetiapine 6. Quetiapine 7. Ziprasidone 8. Aripiprazole 18

Therapeutic Drug Monitoring Digitoxin and Digoxin from Plasma Sample Preparation Pretreatment: Dilute 1 ml plasma with 2 ml DI water and spike with 1 µl of 4 ng/ml oleandrin IS. Solid Phase Extraction (SPE): Cartridge: Strata -X mg/ ml Part No.: 8B-S1-TBJ (see pg. 5 for additional formats) Condition: 2 ml 1 % Methanol Equilibrate: 2 ml 1 mm Ammonium acetate Load: ml Pretreated sample Wash: 1 ml 1 mm Ammonium acetate/1 mm Ammonium acetate in Methanol (5:5) Dry: 1 min at high vacuum Elute: 2x 6 µl 1 % Methanol Evaporate: To dryness @ 5-55 C under a gentle nitrogen stream Reconstitute: 1 µl Methanol/Water (5:5) LC/MS/MS Conditions 42 4 8 6 4 2 28 26 24 22 2 18 16 14 12 1 8 6 4 2 1 2.5 1 1.5 2 2.5.5 4 4.5 min App ID 19692 Column: Kinetex 2.6 µm C8 Dimension: 5 x 2.1 mm Part No.: B-4497-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8784 Mobile Phase: A: 1 mm Ammonium acetate B: 1 mm Ammonium acetate in Methanol. 2.5 2.51 5. 5 1 5 5 Flow Rate:.4 ml/min Column Temperature: C Injection Volume: 4 µl Detection: MS/MS (AB SCIEX API 4 ) Sample: 1. Digoxin 2. Oleandrin. Digitoxin Analyte Q1 Q Digoxin 798.4 651.4 Oleandrin (IS) 577.2 7.2 Digitoxin 782.4 65.4 19

Therapeutic Drug Monitoring Gabapentin from Plasma Sample Preparation Pretreatment: 1. Transfer 1 µl plasma to a.5 ml centrifuge tube 2. Add 1 µl IS/1 % TCA solution to the centrifuge tube, mix briefly. Centrifuge @ 14, rpm for 1 min 4. Transfer 1 µl supernatant to an autosampler vial and QS to 1 ml with water. LC/MS/MS Conditions 2649 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 min App ID 2649 Column: Kinetex 2.6 µm C18 Dimension: 5 x 2.1 mm Part No.: B-4462-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8782 Mobile Phase: A: 5 mm Ammonium formate B: Acetonitrile. 1...1 5. 9 Flow Rate:.4 ml/min Column Temperature: 22 C Injection Volume: 4 µl Detection: MS/MS (AB SCIEX API ) Sample: 1. D4-Gabapentin 2. Gabapentin 2

Therapeutic Drug Monitoring Tricyclic Antidepressants from Plasma Sample Preparation Pretreatment: Dilute 5 µl plasma with 1 ml 1 mm Sodium acetate buffer (ph 5) Solid Phase Extraction (SPE): Cartridge: Strata -X-Drug B mg/ ml Part No.: 8B-S128-TBJ (see pg. 4 for additional formats) Condition: NOT REQUIRED Equilibrate: NOT REQUIRED Load: 5 µl Pretreated sample Wash 1:.8 ml 1 mm Sodium acetate, ph 5 Wash 2:.8mL Methanol Dry: 8-1 min at high vacuum Elute:.4 ml Methanol/Acetonitrile (5:5) plus 2% Ammonium hydroxide Evaporate: To dryness @ 45 C under a gentle nitrogen stream Reconstitute: 5 µl initial mobile phase 297 LC/MS/MS Conditions 6.7e5 6.5e5 7 6.e5 5.5e5 5.e5 4.5e5 4.e5.5e5.e5 2.5e5 2.e5 1.5e5 1.e5 5.e4 1 2 4 6 5 8 9 1 11 12 1 14 5 1. 1.5 2. 2.5..5 4. 4.5 min App ID 297 Column: Kinetex 2.6 µm C18 Dimension: 5 x 2.1 mm Part No.: B-4462-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8782 Mobile Phase: A:.1% Formic acid in Water B:.1% Formic acid in Methanol..5 4. 4.1 5. 4 8 8 4 4 Flow Rate:.5 ml/min Column Temperature: 22 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX API 4 ), ESI+ Sample: 1. Doxepin 2. DM-Doxepin. Imipramine-D 4. Imipramine 5. Desipramine-D 6. Desipramine 7. Nortriptyline-D 8. Nortriptyline 9. Amitriptyline 1. Protriptyline-D 11. Protriptyline 12. Clomipramine-D 1. Clomipramine 14. DM-Clomipramine Analyte Q1 Q Protriptyline 164.2 191.1 Nortriptyline 264. 191.2 DM-Doxepin 266.2 17.1 Desipramine 267.2 28.2 Protriptyline-D 267.2 191.1 Nortriptyline-D 267. 191.2 Desipramine-D 27.2 28.2 Amitriptyline 278.2 191.2 Doxepin 28. 17.1 Imipramine 281. 28.2 Imipramine-D 284.2 28.1 DM-Clomipramine 1.2 242.2 Clomipramine 15.2 242.2 Clomipramine-D 81.2 242.2 21

Pain Panel/Pain Management Drugs Pain Panel Sample Preparation We have provided several sample preparation methods to choose from depending on the goals of your analysis. Solid Phase Extraction (SPE): recommended when working with low concentrations of target analyte Protein Precipitation/β-Glucuronidase Removal: rapid removal of β-glucuronidase Pretreatment for SPE and Protein Precipitation: Urine Acid Hydrolysis Enzymatic Hydrolysis 1. To 2 ml urine sample, add 5 µl concentrated 1. Dilute 5 µl urine with 1 µl buffer* and 2 µl of hydrochloric acid. 1,, units/ml β-glucuronidase in a 96-well 2. Heat at 9 C for 2 hours. collection plate.. Add 2 ml of 2 mm Sodium acetate buffer (ph 4.). 2. Vortex for 5-6 seconds. 4. Add 1 ml of 6 N Potassium hydroxide (KOH). Vortex.. Incubate in a water bath at 62 C for minutes. 5. Centrifuge for 5-6 minutes at 4. If performing SPE, transfer sample to a 96-well collection 5,-5,5 rpm (2-22 C). plate or autosampler vial, seal and centrifuge for 1 6. Verify ph of sample is between 4. 6.. minutes at 2, rpm. Load supernatant onto Strata-X- 7. Load pretreated sample directly onto Drug B sorbent (see procedure below.) If performing rapid Strata-X-Drug B sorbent (see procedure below). removal of β-glucuronidase, load sample directly onto Impact Protein Precipitation plate (see procedure below). Serum / Plasma / Saliva 1. Dilute plasma/serum :1 with 1 % Acetic acid. 2. Vortex.. Centrifuge for 5-6 minutes at,-,5 rpm (2-22 C). 4. Load pretreated sample directly onto Strata-X- Drug B sorbent (see procedure below). For Ultra Clean and Concentrated Samples *Buffer prepared by adding 8 ml deionized water and 111 ml glacial acetic acid to a 1 L volumetric flask, adjust final volume to the line with a 5 % KOH solution and mix by inversion. Strata-X-Drug B SPE Steps Procedure designed for 6 mg bed mass Strata-X-Drug B and can be adjusted for smaller or larger bed masses. Condition: Not required Equilibrate: Not required Load: Pretreated sample (see above for pretreatment recommendations) Wash: 2 ml of 1 mm Sodium acetate buffer (ph 5.) Wash 2: 2 ml Methanol Elute: 2 ml Ethyl acetate/isopropanol/ammonium hydroxide (ph 5.) (7:2:1) Evaporate: to dryness under a stream of Nitrogen at 5 C Reconstitute: 1 ml 15 % Methanol Inject: 5 μl Reduce solvent consumption; no conditioning or equilibration required! For Rapid Removal of Proteins (Ex. β-glucuronidase) Impact Protein Precipitation (PPT) Steps 1. Load µl Acetonitrile to the wells of an Impact Plate 2. Load 1 µl hydrolyzed sample directly onto the Impact Plate. Vortex for 2 minutes at maximum possible speed 4. Apply vacuum at 2-7 inches Hg for 2- minutes and collect filtrate in a collection plate New long drip format now available! Part no. CE-7566 22

Pain Panel/Pain Management Drugs LC/MS/MS Conditions 22121 5.2e6 5.e6 4.8e6 4.6e6 4.4e6 4.2e6 4.e6.8e6.6e6.4e6.2e6.e6 2.8e6 2.6e6 2.4e6 2.2e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e5 6.e5 4.e5 2.e5. 1 2 4 min App ID 22121 Column: Kinetex 2.6 µm Biphenyl Dimensions: 5 x. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic Acid in Water B:.1 % Formic Acid in Methanol. 2.5.5.51 5. 1 1 1 1 1 Flow Rate:.7 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX API 5 ) Analyte Q1 Q Retention Time (min) Morphine 286.2 152 1.8 Oxymorphone 2.1 227 1.44 Hydromorphone 286.2 185 1.5 Amphetamine 16.1 91 1.68 Naloxone 28.1 165.2 1.78 Methamphetamine 15.1 91.2 1.84 Codeine.1 152.1 1.85 MDA 18.1 1 1.86 Oxycodone 16.2 241 1.92 Naltrexone 42.2 267.1 1.94 Hydrocodone.1 199.1 1.96 MDMA 194.1 16.2 1.99 MDEA 28.2 16.2 2.11 Norfentanyl 2.2 84.1 2.2 Tramadol 264.2 58.1 2.24 Benzoylecgonine 29.2 168.1 2. Meperidine 248.2 22 2. Meprobamate 219.2 158.2 2.5 Norbuprenorphine 414. 8.2 2.41 Fentanyl 7.2 15.1 2.6 Buprenorphine 468. 55.2 2.6 Flurazepam 88.2 15.1 2.7 Analyte Q1 Q Retention Time (min) Carisoprodol 261.2 176.2 2.7 PCP 244. 91 2.74 Propoxyphene 4.2 266. 2.75 Sufentanil 87.2 28.2 2.77 6-MAM 28.1 165.2 2.8 Midazolam 26.1 291.1 2.8 Normeperidine 24.1 16.2 2.85 EDDP 278. 24.2 2.95 Methadone 1.2 265.2 2.98 Lorazepam 21 275.1 2.98 Clonazepam 16 27.1. Norpropoxyphene 8.2 1.1.5 Oxazepam 287.1 241.5 Hydroxyalprazolam 25.1 297.12 Nordiazepam 271.1 14.12 Flunitrazepam 14.1 268.2.21 Temazepam 1.1 255.1.24 Alprazolam 9.1 281.26 Diazepam 285.1 19.1.7 2

Pain Panel/Pain Management Drugs Amphetamines from Urine Sample Preparation Pretreatment: Dilute 2 ml with 1 ml 1 mm Phosphate buffer (ph 6.) spiked with IS and.5 M Sodium periodate. Mix/vortex and incubate at room temperature for 2 minutes. Solid Phase Extraction (SPE): Cartridge: Strata -X-Drug B 6 mg/6 ml Part No.: 8B-S128-UCH (see pg. 4 for additional formats) Condition: NOT REQUIRED Equilibrate: NOT REQUIRED Load: Pretreated sample Wash 1: 2 ml 1 mm Sodium acetate, ph 5 Wash 2: 2 ml Methanol Dry: 8-1 min at high vacuum Elute: 2 ml Ethyl acetate/isopropanol/ammonium hydroxide (7:2:1) Evaporate: Add µl.5 N Methanolic hydrochloride. Evaporate to dryness @ 45 C under a gentle nitrogen stream. Reconstitute: 1 ml 1 % Methanol in.1 % Formic acid LC/MS/MS Conditions 7.e5 4 9 6.5e5 6.e5 5.5e5 7 5.e5 4.5e5 4.e5.5e5.e5 2 5 2.5e5 1 2.e5 1.5e5 1.e5 5.e4 6 8 1 App ID 19598. 1.1 1.15 1.2 1.25 1. 1.5 1.4 1.45 1.5 1.55 1.6 1.65 1.7 1.75 1.8 1.85 1.9 1.95 2. 2.5 2.1 2.15 min Column: Kinetex 2.6 µm C18 Dimension: 5 x 2.1 mm Part No.: B-4462-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8782 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol 1 1 7 7 Flow Rate:.4 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 4 ) Sample: 1. D11-Amphetamine 2. Amphetamine. D14-Methamphetamine 4. Methamphetamine 5. D5-MDA 6. MDA 7. D5-MDMA 8. MDMA 9. D5-MDEA 1. MDEA 24

Pain Panel/Pain Management Drugs Benzodiazepines from Urine Sample Preparation Pretreatment: To 2 ml urine add 1 µl β-glucuronidase solution (contains 5 F units/ml Patella Vulgata in 1 mm Acetate buffer, ph 5.) and vortex. Hydrolyze for hours at 6 C. Let cool and add 1 µl of 1 mm Phosphate buffer (ph 6.). Centrifuge for 5 minutes at 5 rpm and discard pellet. Solid Phase Extraction (SPE): Cartridge: Strata -X-Drug N mg/ ml Part No.: 8B-S129-TBJ (see pg. 4 for additional formats) Condition: NOT REQUIRED Equilibrate: NOT REQUIRED Load: Pretreated sample Wash 1: 2 ml Acetonitrile/Water (2:8) Dry: 8-1 min at high vacuum Elute: 2 ml Ethyl acetate/isopropanol (85:15) Evaporate: To dryness @ 45 C under a gentle nitrogen stream Reconstitute: 5 µl initial mobile phase LC/MS/MS 2219 Conditions 7.e5 6.e5 5.e5 4.e5.e5 2.e5 1.e5 1 2 4 5 6 min App ID 2219 Column: Kinetex 2.6 µm Biphenyl Dimensions: 5 x. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol..5 2. 4.5 4.51 5.5 7. 1 1 25 8 85 85 1 Flow Rate:.6 ml/min Injection Volume: 1 µl Column Temperature: 4 C Detection: MS/MS (AB SCIEX API 5 ) Analyte Q1 Q Retention Time (min) Alprazolam 1 (quantifier) 9.1 281.1 5.85 Alprazolam 2 (confirmation) 9.1 25.1 5.85 Clonazepam 1 16. 27.1 5.5 Clonazepam 2 16. 214.2 5.5 Diazepam 1 285.1 19.1 6.1 Diazepam 2 285.1 154. 6.1 Flunitrazepam 1 14.1 268.2 5.78 Flunitrazepam 2 14.1 29.2 5.78 Flurazepam 1 88.2 15.1 5.12 Flurazepam 2 88.2 14.1 5.12 Hydroxyalprazolam 1 25.1 297. 5.65 Hydroxyalprazolam 2 25.1 216.1 5.65 Lorazepam 1 21. 275.1 5.45 Lorazepam 2 21. 229.1 5.45 Midazolam 1 26.1 291.1 5.2 Midazolam 2 26.1 249.1 5.2 Nordiazepam 1 271.1 14. 5.7 Nordiazepam 2 271.1 165.1 5.7 Oxazepam 1 287.1 241. 5.54 Oxazepam 2 287.1 269.1 5.54 Temazepam 1 1.1 255.1 5.8 Temazepam 2 1.1 177.1 5.8 25

Pain Panel/Pain Management Drugs Opiates from Urine Sample Preparation Pretreatment: To 2 ml urine add 5 µl concentrated Hydrochloric acid. Heat at 9 C for 2 hours. Add 2 ml 2 mm Sodium acetate buffer (ph 4.). Add 1 ml 6 N Potassium hydroxide then vortex. Centrifuge for 5 minutes at 5 rpm. Solid Phase Extraction (SPE): Cartridge: Strata -X-Drug B 6 mg/6 ml Part No.: 8B-S128-UCH (see pg. 4 for additional formats) Condition: NOT REQUIRED Equilibrate: NOT REQUIRED Load: Pretreated sample LC/MS/MS 2218 Conditions Wash 1: 2 ml 1 mm Sodium acetate buffer, (ph 5.) Wash 2 2 ml Methanol Dry: 8-1 min at high vacuum Elute: 2 ml Ethyl acetate/isopropanol/ammonium hydroxide (7:2:1) Evaporate: To dryness @ 45 C under a gentle nitrogen stream Reconstitute: 5 µl initial mobile phase 2.e6 1.e6 App ID 2218. 1 2 4 5 6 min Column: Kinetex 2.6 µm Biphenyl Dimensions: 5 x. mm Part No.: B-4622-Y Guard: SecurityGuard ULTRA Biphenyl Cartridges Part No.: AJ-928 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol Gradient: Time (min)..5 2. 4.5 4.51 5.5 7. 1 1 25 8 85 85 1 Flow Rate:.6 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX API 5 ) Analyte Q1 Q Retention Time (min) 6-MAM 1 (quantifier) 28.1 165.2.65 6-MAM 2 (confirmation) 28.1 211.2.65 Codeine 1.1 152.1.6 Codeine 2.1 115.1.6 EDDP 1 278. 24.2 5.6 EDDP 2 278. 186.2 5.6 Fentanyl 1 7.2 15.1 5.1 Fentanyl 2 7.2 188.1 5.1 Hydrocodone 1.1 199.1.84 Hydrocodone 2.1 128.1.84 Hydromorphone 1 286.2 185. 2.76 Hydromorphone 2 286.2 128. 2.76 Meperidine 1 248.2 22. 4.48 Meperidine 2 248.2 174.1 4.48 Methadone 1 1.2 265.2 5.5 Methadone 2 1.2 15. 5.5 Morphine 1 286.2 152. 2.26 Morphine 2 286.2 165. 2.26 Naloxone 1 28.1 212..51 Naloxone 2 28.1 25.1.51 Naltrexone 1 42.2 267.1.82 Naltrexone 2 42.2 212.1.82 Norfentanyl 1 2.2 84.1 4.24 Norfentanyl 2 2.2 15. 4.24 Normeperidine 1 24.1 16.2 4.47 Normeperidine 2 24.1 188.1 4.47 Norpropoxyphene 1 8.2 1.1 5. Norpropoxyphene 2 8.2 14.2 5. Oxycodone 1 16.2 241..76 Oxycodone 2 16.2 256..76 Oxymorphone 1 2.1 227. 2.44 Oxymorphone 2 2.1 198.1 2.44 Propoxyphene 1 4.2 266. 5.2 Propoxyphene 2 4.2 91.1 5.2 Tramadol 1 264.2 58.1 4.2 Tramadol 2 264.2 42.1 4.2 26

Vitamin Testing 25-OH Vitamin D2 and D from Serum Sample Preparation 1. Add 5 µl of precipitating reagent containing internal standard to a 1.5 ml centrifuge tube 2. Pipette 1 µl serum into the centrifuge tube. Vortex 2- sec 4. Inspect each tube to ensure no unmixed sample remains in the bottom of the tube. A homogenous mixture is critical. If unmixed sample remains at the bottom of the tube, dislodge by inverting and tapping, then re-vortex. 5. Centrifuge 15 min at 1, rpm 6. Transfer 1914 supernatant into a sample vial without disturbing the pellet LC/MS/MS Conditions 6.e4 5.e4 4.e4.e4 2.e4 1.e4 25-OH Vitamin D-d6 (IS).6.7.8.9 4. 4.1 4.2 4. 4.4 4.5 4.6 min 1.14e4 1.e4 8 6 4 2 25-OH Vitamin D2.6.7.8.9 4. 4.1 4.2 4. 4.4 4.5 4.6 min 1.6e4 1.4e4 1.2e4 1.e4 8 6 4 2 25-OH Vitamin D.6.7.8.9 4. 4.1 4.2 4. 4.4 4.5 4.6 min App ID 1914 Column: Kinetex 2.6 µm C18 Dimension: 5 x 4.6 mm Part No.: B-4462-E Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8768 Mobile Phase: A:.5 % Formic acid in Water B: 5 mm Ammonium acetate with.1 % Formic acid in Water..8.4 4.8 6. 8 8 1 1 8 Flow Rate: 1 ml/min Column Temperature: 5 C Injection Volume: 5 µl Detection: MS/MS (AB SCIEX API 4 ) Analyte Q1 Q 25-OH Vitamin D2 95. 29. 25-OH Vitamin D 8.2 257.2 25-OH Vitamin D-d6 89. 26. 27

Vitamin Testing 25-OH Vitamin D and -epi-25-oh Vitamin D LC/MS/MS Conditions 1 2.4e6 2.2e6 2.e6 1.8e6 1.6e6 1.4e6 1.2e6 1.e6 8.e5 6.e5 4.e5 2.e5 2 App ID 2.5 1 1.5 2 2.5.5 4 4.5 5 min Column: Kinetex 2.6 µm PFP Dimension: 1 x 2.1 mm Part No.: D-4477-AN Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8787 Mobile Phase: A:.1 % Formic acid in Water B:.1 % Formic acid in Methanol. 2..8.81 6. 75 8 8 75 75 Flow Rate:.4 ml/min Column Temperature: 22 C Injection Volume: 2 µl Detection: MS/MS (AB SCIEX API 5 ) Sample: 1. 25-OH Vitamin D 2. 25-OH Vitamin D2. -epi-25-oh Vitamin D Analyte Q1 Q 25-OH Vitamin D2 95. 29. 25-OH Vitamin D/Epi-D 8.2 257.2 25-OH Vitamin D-d6 86.2 257.2 25-OH Vitamin D (sec trans) 8.2 229.1 25-OH Vitamin D2 (sec trans) 95. 269.2 Representative calibration curves of 25-OH Vitamin D2 and 25-OH Vitamin D. The method was linear across the concentration range of 2.5-1 ng/ml..4.2..28.26.24.22.2.18.16.14.12.1.8.6.4.2. Analyte Area / IS Area 25-OH Vitamin D2 5 1 15 2 25 5 4 45 5 55 6 5 7 75 8 85 9 95 1 ng/ml App ID 26 Analyte Area / IS Area 1.2 1.1 1..9.8.7.6.5.4..2.1. 25-OH Vitamin D 5 1 15 2 25 5 4 45 5 55 6 5 7 75 8 85 9 95 1 ng/ml App ID 27 28

Vitamin Testing Methylmalonic Acid (MMA) from Urine or Serum Sample Preparation Pretreatment: Dilute 1 µl serum or urine with.5 ml 25 mm Ammonium formate and 5 µl IS. Solid Phase Extraction (SPE): Cartridge: Strata -X-AW mg/1 ml Part No.: 8B-S8-TAK (see pg. 5 for additional formats) Condition: 1 ml 1 % Methanol Equilibrate: 1 ml 25 mm Ammonium formate Load: Pretreated sample Wash:.5 ml Methanol/Water (5:5) Dry: 5-1 min at high vacuum Elute: 2x 6 µl 2 % NH 4 OH in Methanol Evaporate: To dryness @ 45-5 C under a gentle nitrogen stream Reconstitute: 2 µl.1 % Formic acid in Water LC/MS/MS Conditions 2.6e5 2.4e5 2 2.2e5 2.e5 1.8e5 1.6e5 1.4e5 1.2e5 1.e5 8.e4 6.e4 4.e4 2.e4 1 App ID 2586..2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 2.6 2.8 min Column: Gemini µm C18 Dimension: 1 x. mm Part No.: D-449-Y Guard: SecurityGuard guard cartridge system Part No.: AJ-7596 Mobile Phase: A:.1 % Formic acid in Water B: 1 mm Ammonium formate in Methanol with.1 % Formic acid 15 95 95 15 15. 1.5 2.5 2.51 4.5 Flow Rate:.7 ml/min Column Temperature: 4 C Injection Volume: 1 µl Detection: MS/MS (AB SCIEX API 4 ), ESI- Sample: 1. Succinic acid 2. Methylmalonic acid (MMA) 29

Vitamin Testing Vitamin B6 from Plasma or Serum by HPLC-Fluorescence Sample Preparation 1. Thaw plasma samples and plasma/serum spiked calibrators or pre-manufactured calibration standards and controls at ambient temperature. Protect from light. 2. Pipette 2 µl plasma blank, calibration standards, controls and plasma samples into appropriately labeled.6 ml amber microcentrifuge tubes. a. Briefly vortex the calibrators and controls immediately prior to sampling. b. Mix the plasma samples by gentle inversion immediately prior to sampling. c. Protect the tubes from light.. Add µl of 1 mg/ml semicarbazide/glycine solution into all the tubes containing samples; cap the tubes, vortex for 15 sec. 4. Incubate in the dark at room temperature for min. 5. Uncap the tubes; add 25 µl of 2 % meta-phosphoric acid to the controls and samples. 6. Recap the tubes and vortex for sec. 7. Centrifuge for 5 min at 14, rpm at room temperature. Note: The relative centrifugal force (RCF) = 16, g. 8. Transfer 15 µl of supernatant to an amber autosampler glass Verex vial. 9. Cover the vial with a screw cap and place it in the autosampler at room temperature HPLC-Fluorescence Conditions mau 9 8 7 6 5 4 2 1 14 1 2 1 2 4 5 6 min Representative calibration curve for Pyridoxal 5 -phosphate. The method was linear across the concentration range of 6.25-2 nmol/l. App ID 2684 Column: Gemini µm NX-C18 Dimension: 1 x 4.6 mm Part No.: D-445-E Guard: SecurityGuard guard cartridge system Part No.: AJ-868 Mobile Phase: A: 2 mm Sodium phosphate and 1. ml Acetic acid in 1 L DI water, ph 6 B: Acetonitrile/Methanol (7:). 5. 5.1 6. 7. 5 6 95 5 5 Flow Rate: 1 ml/min Column Temperature: 5 C Injection Volume: µl Detection Fluorescence, Ex 6, Em 45 Sample: 1. Pyridoxal 5 -phosphate 2. 4-Pyridoxic Acid. Pyridoxal 12 1 Analyte Area / IS Area 8 6 4 r=.9999 2 5 1 15 2 25 nmol / L

Vitamin Testing Vitamin C from Plasma or Serum by LC/UV Sample Preparation Rapid Protein Precipitation: 1. Add µl cold 5 % Meta-phosphoric acid (4 C) to the wells of an Impact Protein Precipitation Plate (see pg. 7 for ordering information) 2. Add 1 µl plasma/serum directly into the 5 % Meta-phosphoric acid. Mix 5 times by aspirating with same pipette tip 4. Centrifuge* the Impact plate at 5 g (with collection plate underneath) for 5 min at 4 C. Purified filtrate is collected in the collection plate. * A vacuum manifold may be used however 25 Hg vacuum pressure must be applied for up to 1 minutes or until sample is completely pulled through the Impact plate LC/UV Conditions 21441 mau 14 Vitamin C 12 1 8 6 4 2 Uric Acid 1 2 4 5 6 min Representative calibration curve for Vitamin C. The method was linear across a concentration range of Vitamin - 1 µg/ml. C in Human Plasma by Impact Plate (Kinetex 5 µm, XB-C18, 15 x 4.6 mm + Guard) App ID 21441 Column: Kinetex 5 µm XB-C18 Dimension: 15 x 4.6 mm Part No.: F-465-E Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8768 Mobile Phase: A:.1 % Formic acid in Water B: Acetonitrile..5.6 5. 5.1 7. 1 1 Flow Rate:.8 ml/min Column Temperature: 22 C Injection Volume: µl Detection UV-Vis @ 245 nm Sample: 1. Vitamin C (ascorbic acid) 2. Uric acid Analyte Area / IS Area 25 2 15 1 r=.9999 5 2 4 6 8 1 12-5 µg/ml 1

Forensic/Drugs of Abuse Nicotine and Metabolites from Urine Sample Preparation Pretreatment: Dilute.5 ml urine with.5 ml of 2 mm Ammonium acetate, ph 4, and 1 µl IS. Solid Phase Extraction (SPE): Cartridge: Strata -X-C 6 mg/ ml Part No.: 8B-S29-UBJ (see pg. 5 for additional formats) Condition: 2 ml 1 % Methanol Equilibrate: 2 ml Ammonium acetate buffer Load:.5 ml Pretreated sample Wash 1: 2 ml Ammonium acetate buffer Wash 2 2 ml % Methanol in Water Dry: 5 min at high vacuum Elute: 2x 2 ml 1.5 % Ammonium hydroxide in Methanol Evaporate: To dryness @ 55 C under a gentle nitrogen stream Reconstitute: 5 µl Acetonitrile/2 mm Ammonium bicarbonate (1:9) LC/MS/MS Conditions 1.6e5 1.5e5 1.4e5 1.e5 1.2e5 1.1e5 1.e5 9.e4 8.e4 7.e4 6.e4 5.e4 4.e4.e4 2.e4 1.e4. 1 2 4 5.5 1. 1.5 2. 2.5..5 4. 4.5 min Analyte Q1 Q Nicotine 16.1 12.1 Nicotine-D4 167.1 16. Cotinine 177.1 8.1 Cotinine-D 18.1 8.1 Nornicotine 149.1 8.1 Nornicotine-D4 15.1 84.1 -OH-cotinine 19.1 8.1 -OH-cotinine-D 196.1 8.1 Anabasine 16.1 12.1 App ID 2222 Column: Gemini µm NX-C18 Dimension: 5 x 2. mm Part No.: B-445-B Guard: SecurityGuard guard cartridge system Part No.: AJ-867 Mobile Phase: A: 2 mm Ammonium bicarbonate B: Acetonitrile...1 5. 1 75 1 1 Flow Rate:.5 ml/min Column Temperature: 25 C Injection Volume: 1 µl Detection MS/MS (AB SCIEX API 4 ), ESI+ Sample: 1. Nornicotine 2. -OH-Cotinine. Anabasine 4. Cotinine 5. Nicotine Representative calibration curve for Nornicotine. The method was linear across a concentration range of 1-5 ng/ml. Analyte Area / IS Area 14 1 12 11 1 9 8 7 6 5 4 r =.9997 2 1 2 4 6 8 1 12 14 16 18 2 22 24 26 28 2 4 6 8 4 42 44 46 48 5 ng/ml 2

Forensic/Drugs of Abuse Bath Salts LC/MS/MS Conditions 279 4.8e6 4.5e6 1 2 4.e6.5e6.e6 2.5e6 2.e6 1.5e6 1.e6 5.e5. 4.5 1. 1.5 2. 2.5..5 4. 4.5 5. 5.5 min App ID 279 Column: Kinetex 2.6 µm C18 Dimension: 5 x. mm Part No.: B-4462-Y Guard: SecurityGuard ULTRA guard cartridge system Part No.: AJ-8775 Mobile Phase: A: 1 mm Ammonium formate B:.1 % Formic acid in Methanol.. 4. 4.1 5 1 1 5 Flow Rate:.5 ml/min Column Temperature: 22 C Injection Volume: 5 µl Detection MS/MS (AB SCIEX API 4 ) Sample: 1. Methamphetamine 2. Methylone. Mephedrone 4. MDPV

Solid Phase Extraction (SPE) Capitalize on Cleanliness without Sacrificing Recovery With Strata-X polymeric SPE sorbents the guesswork that leads to lengthy method development is eliminated. Unique selectivities have been developed to cover a diverse spectrum of analytes, simplifying the method development process for fast and efficient sample preparation. Strata -X SPE Sorbents Find the best Strata-X sorbent for your target analytes Acidic Compounds Neutral Compounds Basic Compounds Strong Acids (pka < 2) Strata-X-AW Weak Acids (pka 2 4) Strata-X-A Neutral Compounds Strata-X Weak Bases (pka 8 1) Strata-X-C Strong Bases (pka > 1) Strata-X-CW Reversed Phase & Weak Anion-Exchange Reversed Phase & Strong Anion-Exchange Reversed Phase Reversed Phase & Strong Cation-Exchange Reversed Phase & Weak Cation-Exchange Strata-X-Drug SPE Sorbents Choose from 2 different phases that are designed and quality control tested for drugs of abuse analysis. Ordering Information Strata-X-Drug B for BASIC drugs of abuse Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S128-TAK 1 ml (1/box) Tube 1 mg 8B-S128-AAK 1 ml (1/box) mg 8B-S128-TAK 1 ml (1/box) mg 8B-S128-TBJ ml (5/box) 6 mg 8B-S128-UBJ ml (5/box) 6 mg 8B-S128-UCH 6 ml (/box) 6 mg 8B-S128-UCL 6 ml (2/box) Giga Tube 1 mg 8B-S128-EDG 12 ml (2/box) Strata-X-Drug N for NEUTRAL drugs of abuse Format Sorbent Mass Part Number Unit Price Tube mg 8B-S129-TAK 1 ml (1/box) mg 8B-S129-TBJ ml (5/box) 6 mg 8B-S129-UBJ ml (5/box) 6 mg 8B-S129-UCH 6 ml (/box) 6 mg 8B-S129-UCL 6 ml (2/bag) 1 mg 8B-S129-ECH 6 ml (/box) 96-Well Plate 1 mg 8E-S129-AGB 2 Plates/box mg 8E-S129-TGB 2 Plates/box 6 mg 8E-S129-UGB 2 Plates/box 96-Well Plate 1 mg 8E-S128-AGB 2 Plates/box mg 8E-S128-TGB 2 Plates/box 6 mg 8E-S128-UGB 2 Plates/box SPE Method Development Tool Create a Customized Method in Under 1 Minute and Receive a FREE Sample of Strata-X 1. Visit www.phenomenex.com/mdtool and create a customized SPE method by inputting your target analyte, sample matrix, and sample volume. 2. After using the SPE Method Development Tool, request a free sample by clicking on the Request Free Sample button. 4 Phenomenex l WEB: www.phenomenex.com

Ordering Information Strata -X Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S1-TAK 1 ml (1/box) 6 mg 8L-S1-UBJ ml (5/box) Tube mg 8B-S1-TAK 1 ml (1/box) mg 8B-S1-TBJ ml (5/box) 6 mg 8B-S1-UBJ ml (5/box) 1 mg 8B-S1-EBJ ml (5/box) 1 mg 8B-S1-ECH 6 ml (/box) 2 mg 8B-S1-FBJ ml (5/box) 2 mg 8B-S1-FCH 6 ml (/box) 5 mg 8B-S1-HBJ ml (5/box) 5 mg 8B-S1-HCH 6 ml (/box) 96-Well Plate 1 mg 8E-S1-AGB 2 Plates/Box mg 8E-S1-TGB 2 Plates/Box 6 mg 8E-S1-UGB 2 Plates/Box On-line Extraction Cartridge Description Part No. Unit/Box Price Strata-X on-line extraction M-S-B-CB ea cartridge, 2 x 2. mm Cartridge holder, 2 mm CH-5845 ea Strata-X-C Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S29-TAK 1 ml (1/box) 6 mg 8L-S29-UBJ ml (5/box) Tube mg 8B-S29-TAK 1 ml (1/box) mg 8B-S29-TBJ ml (5/box) 6 mg 8B-S29-UBJ ml (5/box) 1 mg 8B-S29-EBJ ml (5/box) 1 mg 8B-S29-ECH 6 ml (/box) 2 mg 8B-S29-FBJ ml (5/box) 2 mg 8B-S29-FCH 6 ml (/box) 5 mg 8B-S29-HBJ ml (5/box) 5 mg 8B-S29-HCH 6 ml (/box) 96-Well Plate 1 mg 8E-S29-AGB 2 Plates/Box mg 8E-S29-TGB 2 Plates/Box 6 mg 8E-S29-UGB 2 Plates/Box On-line Extraction Cartridge Description Part Number Unit Price Strata-X-C on-line extraction M-S48-B-CB ea cartridge, 2 x 2. mm Cartridge holder, 2 mm CH-5845 ea If Strata-X SPE products do not perform as well or better than your current SPE product of similar phase, mass and size, return your products with comparative data within 45 days and keep the Strata-X SPE product for FREE! Strata-X-CW Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S5-TAK 1 ml (1/box) Tube mg 8B-S5-TAK 1 ml (1/box) mg 8B-S5-TBJ ml (5/box) 6 mg 8B-S5-UBJ ml (5/box) 1 mg 8B-S5-ECH 6 ml (/box) 2 mg 8B-S5-FBJ ml (5/box) 2 mg 8B-S5-FCH 6 ml (/box) 5 mg 8B-S5-HBJ ml (5/box) 5 mg 8B-S5-HCH 6 ml (/box) 96-Well Plate 1 mg 8E-S5-AGB 2 Plates/Box mg 8E-S5-TGB 2 Plates/Box 6 mg 8E-S5-UGB 2 Plates/Box Description Part Number Unit Price Strata-X-CW on-line extraction M-S6-B-CB ea cartridge, 2 x 2. mm Cartridge holder, 2 mm CH-5845 ea Strata-X-A Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S12-TAK 1 ml(1/box) Tube mg 8B-S12-TAK 1 ml (1/box) mg 8B-S12-TBJ ml (5/box) 6 mg 8B-S12-UBJ ml (5/box) 1 mg 8B-S12-EBJ ml (5/box) 1 mg 8B-S12-ECH 6 ml (/box) 2 mg 8B-S12-FBJ ml (5/box) 2 mg 8B-S12-FCH 6 ml (/box) 5 mg 8B-S12-HBJ ml (5/box) 5 mg 8B-S12-HCH 6 ml (/box) 96-Well Plate 1 mg 8E-S12-AGB 2 Plates/Box mg 8E-S12-TGB 2 Plates/Box 6 mg 8E-S12-UGB 2 Plates/Box Strata-X-AW Format Sorbent Mass Part Number Unit Price Tab-Less Tube mg 8L-S8-TAK 1 ml(1/box) Tube mg 8B-S8-TAK 1 ml (1/box) mg 8B-S8-TBJ ml (5/box) 6 mg 8B-S8-UBJ ml (5/box) 1 mg 8B-S8-EBJ ml (5/box) 1 mg 8B-S8-ECH 6 ml (/box) 2 mg 8B-S8-FBJ ml (5/box) 2 mg 8B-S8-FCH 6 ml (/box) 5 mg 8B-S8-HBJ ml (5/box) 5 mg 8B-S8-HCH 6 ml (/box) 96-Well Plate 1 mg 8E-S8-AGB 2 Plates/Box mg 8E-S8-TGB 2 Plates/Box 6 mg 8E-S8-UGB 2 Plates/Box Don t forget your vacuum manifold, collection plates, and sealing mats p. 6. Phenomenex l WEB: www.phenomenex.com 5

Phospholipid Removal Phospholipid Removal Solutions Eliminate Ion Suppression with Phree Phospholipid Removal Products Consistently remove > 99% of phospholipids to increase LC/MS sensitivity Simultaneously remove interfering proteins No additional time required, the Phree method can be performed in the same amount of time as a protein precipitation procedure Skip the method development; one method for acids, bases, and neutrals How it Works: Remove Proteins Solvent Shielding Technology prevents dripping of organic solvent, allowing for protein precipitation within the wells of the Phree Phospholipid Removal Product. Eliminate Phospholipids The Phree sorbent selectively removes phospholipids from precipitated plasma samples. Proteins Phospholipids Target Analyte Phree Phospholipid Removal Products Part No. Description Unit Price 8B-S1-TAK Phree Phospholipid Removal 1 ml Tube 1/box 8E-S1-TGB Phree Phospholipid Removal 96-Well Plates 2/box Accessories Collection Plates (deep well, polypropylene) AH-7192 96-Well Collection Plate 5 µl/well 5/pk AH-719 96-Well Collection Plate 1 ml/well 5/pk AH-7194 96-Well Collection Plate 2 ml/well 5/pk AH-865 96-Well Collection Plate, 2 ml Square/Round-Conical 5/pk AH-866 96-Well Collection Plate, 2 ml Round/Round, 8 mm 5/pk AH-7279 96-Well Collection Plate, 1 ml/well Round, 7 mm 5/pk Sealing Mats AH-8597 Sealing Mats, Pierceable, 96-Square Well, Silicone 5/pk AH-8598 Sealing Mats, Pre-Slit, 96-Square Well, Silicone 5/pk AH-861 Sealing Mats, Pierceable, 96-Round Well 7 mm, Silicone 5/pk AH-862 Sealing Mats, Pre-Slit, 96-Round Well 7 mm, Silicone 5/pk AH-86 Sealing Mats, Pierceable, 96-Round Well 8 mm, Silicone 5/pk AH-864 Sealing Mats, Pre-Slit, 96-Round Well 8 mm, Silicone 5/pk AH-762 Sealing Tape Pad 1/pk Vacuum Manifolds AH-62* SPE 12-Position Vacuum Manifold Set, for tubes ea AH-624* SPE 24-Position Vacuum Manifold Set, for tubes ea AH-895 96-Well Plate Manifold, Universal with Vacuum Gauge ea *Manifolds include: Vacuum-tight glass chamber, vacuum gauge assembly, polypropylene lid with gasket, male and female luers and yellow end plugs, stopcock valves, collection rack assemblies, polypropylene needles, lid support legs. Waste container included with 12-positive manifold. If Phree Phospholipid Removal products do not perform as well or better than your current phospholipid removal products, send in your comparative data within 45 days and keep the Phree Phospholipid Removal product for FREE! 6 Phenomenex l WEB: www.phenomenex.com

Protein Precipitation Impact Rapid Protein Precipitation Quickly cleanup sample by passing biological samples through the Impact filter Increase sensitivity of your analysis by eliminating proteins which contribute to baseline noise Increase reproducibility with the leak-free membrane, preventing premature sample breakthrough and incomplete protein precipitation How it Works: Proteins Target Analyte Impact Protein Precipitation Plates Part No. Description Unit Price Impact Precipitation Plates CE-7565 Impact Protein Precipitation, Square Well, Filter Plate, 2 ml CE-7566 Impact Protein Precipitation, Square Well, Filter Plate, 2 ml, Long Drip 2/box 2/box Impact Starter Kit for Protein Precipitation CE-821 Impact Protein Precipitation Plate (2 ea) Collection Plate 2 ml (2 ea) Sealing Mat, Santoprene (AH-8199) (2 ea) ea Don t forget your vacuum manifold, collection plates, and sealing mats p. 6. If Impact does not perform as well or better than your current protein precipitation plate with similar specifications, send in your comparative data within 45 days and keep the Impact product for FREE! Phenomenex l WEB: www.phenomenex.com 7

Thrive with Kinetex Core-Shell Technology! Complete Scalable Solution from UHPLC to HPLC Core-Shell Technology UHPLC HPLC 1. µm 1.7 µm 2.6 µm 5 µm Incredible UHPLC efficiency and performance gains Six Highly Functional Stationary Phases Phase Selectivity Kinetex Biphenyl Excellent reversed phase and aromatic retention and selectivity Kinetex C18 Kinetex XB-C18 Kinetex C8 Kinetex Phenyl-Hexyl Kinetex HILIC 2 % higher efficiency than fully porous 1.7 μm columns General hydrophobic selectivity and increased retention of polar basic compounds Excellent hydrophobic selectivity and increased retention of polar acidic compounds Less hydrophobic than a C18 phase Greater retention and separation of aromatic hydrocarbons Increased polar retention under HILIC conditions Better Performance than Fully Porous Particles Achieve sub-2 μm performance on HPLC and UHPLC systems Solid Core μm or better efficiencies at 5 μm pressures for HPLC methods Porous Shell Using sol-gel processing techniques that incorporate nano structuring technology, a durable, homogeneous porous shell is grown on a solid silica core. This highly optimized process combined with industry leading column packing technology produces highly reproducible columns that generate extremely high plate counts. Fully Porous Kinetex Core-Shell Average Efficiency Gain with Kinetex* Fully Porous Kinetex Core-Shell Average Efficiency Gain with Kinetex* 5 µm VS 5 µm 9 % Higher 1.7 µm VS 1.7 µm 2 % Higher µm VS 2.6 µm 85 % Higher 1.7 µm VS 1. µm 5 % Higher * May not be representative of all applications Ordering Information SecurityGuard 5 μm Minibore Columns (mm) ULTRA Cartridges Phases 5 x 2.1 1 x 2.1 /pk Biphenyl B-4627-AN D-4627-AN AJ-929 XB-C18 B-465-AN D-465-AN AJ-8782 C18 B-461-AN D-461-AN AJ-8782 C8 B-468-AN D-468-AN AJ-8784 Phenyl-Hexyl B-46-AN D-46-AN AJ-8788 for 2.1 mm ID SecurityGuard ULTRA Cartridges require holder, Part No.: AJ-9 SecurityGuard 5 μm MidBore Columns (mm) ULTRA Cartridges Phases 5 x. 1 x. /pk Biphenyl B-4627-Y D-4627-Y AJ-928 XB-C18 B-465-Y D-465-Y AJ-8775 C18 B-461-Y D-461-Y AJ-8775 C8 B-468-Y D-468-Y AJ-8777 Phenyl-Hexyl B-46-Y D-46-Y AJ-8781 for. mm ID 8 Phenomenex l WEB: www.phenomenex.com