Amino Acid Analyzer L-8900



Similar documents
Protocol: HPLC (amino acids)

Appendix 5 Overview of requirements in English

QUANTITATIVE AMINO ACID ANALYSIS. Aurélie Lolia Applications Manager, Biochrom Ltd

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Smartline HPLC by design

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

DETERMINATION OF AMINO ACID CONTENT IN ROMANIAN SALAMI BY ION-EXCHANGE CHROMATOGRAPHY

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Application Note. Determination of Amino acids by UHPLC with automated OPA- Derivatization by the Autosampler. Summary. Fig. 1.

Application Note. Determination of 17 AQC derivatized Amino acids in baby food samples. Summary. Introduction. Category Bio science, food Matrix

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Chapter 28: High-Performance Liquid Chromatography (HPLC)

23 The Thermal Conductivity Detector

How To Test For Contamination In Large Volume Water

Purification of reaction mixtures using flash chromatography.

INSTRUCTIONS Edition AC

ChromQuest 5.0 Chromatography Data System

Mitos P-Pump. product datasheet

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Image Area EXCEPTIONAL PERFORMANCE FOR CHALLENGING MERCURY ANALYSES. FIMS 100 and 400. Flow Injection Mercury Systems

Determination of Food Dye Concentrations in an Unknown Aqueous Sample Using HPLC

ÄKTA system Training Guide

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Rapid and Reproducible Amino Acid Analysis of Physiological Fluids for Clinical Research Using LC/MS/MS with the atraq Kit

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

Using the AS Automated Sampler in the Simultaneous, Sequential, and Concentrate Modes

C196-E056F LC-2010HT. Shimadzu High-performance Liquid Chromatograph

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

Analysis of protein hydrolysates and oxidized hydrolysates are done using Pickering s Sodium columns and eluants.

Analysis of Vegetable Oils by High Performance Liquid Chromatography

Ultra High Performance Liquid Chromatograph. Nexera XR C196-E082B

Introduction to the ACQUITY UPLC H-Class Amino Acid Analysis System

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Determination of Calcium and Magnesium in Brine

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

C196-E056C LC-2010HT. Shimadzu High-performance Liquid Chromatograph

STANFORD UNIVERSITY MASS SPECTROMETRY 333 CAMPUS DR., MUDD 175 STANFORD, CA

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

FMA-80 Fluorescence Mercury Analyzer

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Gel Filtration Standard

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

ORIGINAL SCIENTIFIC PAPER. Gabriella POHN. Éva VARGA-VISI SUMMARY KEY WORDS

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Method Development for Size-Exclusion Chromatography of Monoclonal Antibodies and Higher Order Aggregates

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

ORGANIC SAMPLE PREPARATION

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

designed to never let you down PerkinElmer Series 200 HPLC Systems

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

MILESTONE H E L P I N G C H E M I S T S

SCION SQ Series GC-MS

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

Online Infrared Flue Gas Analyzer Gasboard 3000

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

A Complete Solution for Method Linearity in HPLC and UHPLC

PINNACLE PCX BUFFERS REAGENTS COLUMNS CHROMATOGRAMS AMINO AMINO ACID ANALYSIS PRODUCTS

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

HPLC Basics, Equipment, and Troubleshooting

State of the Art Energy Efficient Data Centre Air Conditioning

Successful HPLC Operation. A Troubleshooting Guide Version 1.1

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Waters 2695 Separations Module

SUCRALOSE. White to off-white, practically odourless crystalline powder

RapidFire for High Throughput Screening in early Drug Discovery

POROS CaptureSelect affinity columns for highspeed quantification of IgG Fc fusion proteins

Office of Contracts Administration Purchasing

Tuning & Mass Calibration

GC-xt. The most flexible GC /GC-MS liquid sample injector

The Theory of HPLC. Gradient HPLC

DMA-1 Direct Mercury Analyzer

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

A new concept for isotope ratio monitoring LC/MS. A Wide Range of Applications

Analyzing Small Molecules by EI and GC-MS. July 2014

Background Information

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

High Sensitivity MS Determination of Carryover in a New Autosampler Design

ERDOSTEINE - MONOGRAPH.

Transcription:

Amino Acid Analyzer L-8900

VWR - Hitachi Your Partner in Amino Acid Analysis Hitachi has manufactured more than 1800 Amino Acid Analysers for over 40 years. The new Amino Acid Analyser Model L-8900 is the culmination of the technology and expertise earned from the extensive experience in manufacturing of Amino Acid Analysers during that time. Hitachi offers the best solution to amino acid analysis worldwide. 1. 2. 3. 4. A high-speed, real-time feedback control system of the pump ensures excellent flow rate stability. The gradient elution capability enables the operator to optimise the application to a shorter runtime. A built-in degasser for all eluents stabilises the pump flow and improves the injection and peak area precision. By using a degasser for the washing solution of the autosampler best precision of the injection volume is achieved. Carry-Over is minimised by the free programmable washing procedure. The ion exchange resin of the separation column is based on 3 µm particles. This guarantees an excellent resolution of sample peaks and enhances the quality of the analysis.

L-8900 The instrument excellently meets all requirements for analyzing physiological and hydrolysated amino acids using post-column derivatisation. The instrument is designed to be the best on the market in terms of quality, safety, separation performance, robustness, operability and cost per analysis. The complete system is CFR 21 Part 11 compliant; Pre-Assigned Report Templates for the results are available. 5. 6. 7. 8. The L-8900's unique post column delivery design mixes the two ninhydrin reagents just prior to amino acid derivatisation. Therefore the solutions can be stored for over one year without refrigeration. The L-8900 features a special reaction column to maintain good separation of the sample zones and yet offering high sensitivity and highspeed analysis. The diamonds-packed reactor has an extremely long life-time without any tendency for blocking. An internally programmed shut-off procedure that acts independently on the software control prevents contaminations of the reaction column even in case of software or instrument failure. The reference wavelength of the dual beam detector stabilises the baseline, enhances the detection sensitivity and minimises the effect of lamp ageing.

1. Autosampler Variable sample volume: 0.1-100 µl Cooling option available 1. 2. Pumps Buffer and Ninhydrin delivery with flowoptimized HPLC pumps 2. 8. 3. 3. Degasser Degassing of all necessary buffers and reagents 8. Waste Collector Integrated in the system, with special waste gas absorbing filter L-8900

4. Column Oven 7. 4. Very stable with quick response due to Peltier heating 7. Photometer 5. 2-channel-detector with a reference wavelength 5. Reactor 6. Reaction column with special diamond packing 6. Buffer Cabinet Reagents and buffers are kept under inert gas atmosphere Analyzer Status Screen Gray background: OFF Yellow background: ON Maintenance buttons Manual control buttons

The Amino Acid Analyzer Standard protein hydrolysate, 30 min. Column size: 4.6 x 60 mm, Fast feedstuff analysis, 40 min. Column size: 4.6 x 60 mm, Extended protein hydrolysate with amino sugars, glucosamine and galactosamine

L-8900 High-resolution physiological fluid analysis Column size: 4.6 x 60 mm, Optimised physiological programm for special amino acids of certain children s metabolism diseases Column size: 4.6 x 60 mm, High-speed physiological sample analysis Column size: 5.4 x (25 + 25) mm,

The Amino Acid Analyzer L-8900 Technical Specifications Pumps: - Dual plunger system with electronic compensation of the solvent compressibility and with elimination of the residual pulsation - Automatic pump plunger wash function - Constant pressure mode for column packing - Leak sensor Flow rate: 0.05 to 1.00 ml/min. Max. pressure: 20 MPa Flow rate precision: 0.075 % RSD or 0.02 min. SD Flow rate accuracy: +/- 2 % Autosampler: Injection precision: Carry-Over: - Direct injection, rack of 200 samples (cooling rack optional) - Injection volume: 0.1 to 100 µl - Leak sensor, vial sensor RSD 1.0 % (Gly, His) < 0.1 % for Asp Column oven: Column - Peltier-heated - Temperature range: 20 to 85 degrees (1 degree steps) - diffrent Types are available Reactor: - Heating block - Temperature range: 50 to 140 degrees (1 degree steps) Photometer: - Diffraction grating - Filter photometer, measures two wavelength: 570 nm and 440 nm, reference: 700 nm - Cell volume: 8 µl Performance: - Analysis time: Approx. 30 min. for hydrolysate (Standards) Approx. 60 min. for physiological fluids (Standards) - Precision of peak retention time: RSD 0.3 % (Arg), 0.5 % (Ala) - Precision of peak area: RSD 1.0 % (Gly, His) - Detection limit: 3 pmol (S/N = 2, Asp) Software: - EZ Chrom Elite TM, Control and integration software - fulfills the requirements of the FDA 21CFR Part 11 VWR International GmbH Scientific Instruments Hilpertstr. 20A D - 64295 Darmstadt Germany Fax: ++ 49-61 51-39 72-1 01 e-mail: chrom-instruments@de.vwr.com www.vwr.com