Improving Workflow Efficiency using the Trimble R10 with SurePoint. Marco Wuethrich Trimble Applications Specialist



Similar documents
Frequently Asked Questions (FAQs)

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

MGL Avionics Compass operation and calibration

User checks and maintenance of laboratory balances

T-TOUCH EXPERT User s Manual

How To Control Gimbal

Information regarding the Lockheed F-104 Starfighter F-104 LN-3. An article published in the Zipper Magazine #48. December Theo N.M.M.

KNOWLEDGE BASE ARTICLE Zero Voltage Transmission (ZVT) Technology. Basics of the GPZ 7000 Technology: Zero Voltage Transmission (ZVT)

Solar Shading Android Application v6.0. User s Manual

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Introduction to Trimble Access. The Next Generation of Survey Controller S-0102

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

IP-S2 Compact+ 3D Mobile Mapping System

Leica DNA digital levels Advantages that move you ahead

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

BL-DBK150A DUAL BATTERY 12v 150 AMP SMART SYSTEM

DISSOLVED OXYGEN METER Model : DO-5509

Sensor Fusion Mobile Platform Challenges and Future Directions Jim Steele VP of Engineering, Sensor Platforms, Inc.

product. Please read this instruction before setup your VenomXTM.

Accuracy and Tuning in CNC Machine Tools

Exploring Magnetism. DataQuest

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

SuperNav for Heavy Equipment

Motion Sensing with mcube igyro Delivering New Experiences for Motion Gaming and Augmented Reality for Android Mobile Devices

ANDROID APPS DEVELOPMENT FOR MOBILE AND TABLET DEVICE (LEVEL II)

THE NEED TO IMPLEMENT CONSTRUCTION DEFORMATION SPATIAL MONITORING SYSTEMS IN ROMANIA

The Basics of Robot Mazes Teacher Notes

Frequently Asked Whip Mix Articulator Questions

Advanced Surveying Control Services for Building the Vertical Cities.

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

How To Use Gss Software In Trimble Business Center

LW A. Wireless Auto Dial Alarm System. Sentry Plus User Manual By Global Gadgets

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

Experiment 6: Magnetic Force on a Current Carrying Wire

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

PART 1 - INTRODUCTION...

Subminiature Load Cell Model 8417

Trimble Field Link Software

Innovative measurement technology for real professionals.

THE STRUCTURAL HEALTH MONITORING SYSTEM OF THE RION ANTIRION BRIDGE CHARILAOS TRIKOUPIS. Akis Panagis

Fundamentals of Mass Flow Control

Leica 3D Disto Recreating the real world

Wrap Tracker 6TC. User Guide

3 LEVELLING & SURVEYING

Practical Alignment Tools and Techniques

MOBILE CALL GSM alarm system

understanding sensors

OPERATION MANUAL INFRARED THERMOMETER

AlcoScan AL-5000 User s Manual

Penmap Surveying for Everyone. Visit us on: A TRIMBLE COMPANY

Monitoring Ground Vibration arising from Piling and Civil Engineering Projects

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Milwaukee USER MANUAL

Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge

Home Alarm System. Product Description

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Workholding systems. Magnetic clamping plates M-TECS SP 50 M-TECS SP 70

Velocity AV-2. Introduction. 1 Features. Artificial horizon and advanced magnetic compass indicator. Operating Manual English 1.04

Contents OVERVIEW WORKFLOW PROBLEM. SOLUTION. FEATURE. BENEFIT 4 5 EASY STEPS TO CALIBRATE YOUR LENSES 5

SkEye. Planetarium and PUSHTO guide for Android. Written for SkEye Pro 2.1 and SkEye Free 5.1. Harshad RJ 15 th November 2011

Model UT713 OPERATING MANUAL

Trimble TerraSync User Guide for Laser GPS Offset

Solar Tracking Controller

USB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright Pico Technology Limited. All rights reserved.

Print then Cut Calibration

Network Enabled Battery Health Monitoring System

reach trucks UNS/UHS, USS, UFS & URF Nissan Forklift Europe B.V. CEN-RT-NFE/ Printed in the Netherlands

Coal Handling Plant Alignment Standards For Shaft To Shaft Alignment. By Makarand Joshi M.Tech

Solar Tracking Application

G-PORTER. Portable GPS Tracker GP-102 User s Manual

IP-S3 HD1. Compact, High-Density 3D Mobile Mapping System

RS DIGITAL THERMOMETER

Autos Limited Ghana Vehicle Tracking Business Proposal

SUUNTO AMBIT2 USER GUIDE

The software beyond the climatic. Environment simulation

The Basics of Navigation

Computer Lane Monitor for Windows

71M6521 Energy Meter IC. Real Time Clock Compensation. The Challenge. The RTC in the 71M6521D/F. Theory of Operation APPLICATION NOTE

MIT510/2, MIT520/2 and MIT1020/2

GPS/GSM Personal Tracking Device

Toroidal Conductivity Sensor

APPLANIX POSITION AND ORIENTATION SYSTEMS FOR LAND VEHICLES (POS LV)

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

ix3m Dive Computer Installable Apps Manual ver. 1.1

LEICA DNA digital levels Advantages that move you ahead. LEICA DNA digital levels

Best Practices for Reducing Transmitter Life Cycle Costs

T-TOUCH II User s Manual

SBB Infrastructure, Measurement and Diagnostic Technology.

Experiment 3: Magnetic Fields of a Bar Magnet and Helmholtz Coil

Sensors and Cellphones

TOYOTA SAS Guide. site:

Security GSM Alarm System

Free Fall: Observing and Analyzing the Free Fall Motion of a Bouncing Ping-Pong Ball and Calculating the Free Fall Acceleration (Teacher s Guide)

Magnetic Fields and Their Effects

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

Transcription:

Improving Workflow Efficiency using the Trimble R10 with SurePoint Marco Wuethrich Trimble Applications Specialist

Content Trimble SurePoint technology Trimble R10 (1) ebubble, (2) tilt auto-measure and (3) tilt compensated points: Hardware sensors Calibrations and environment Demo Examples of using R10 with SurePoint How do you achieve an improved workflow efficiency Summary of Trimble SurePoint Questions

Trimble SurePoint Built into Trimble S-Series total stations for many years Ensures precise measurements Remains aimed at target to guard against: Sinkage Accidental bumps Pressing key with excessive force And more

Trimble SurePoint in GNSS SurePoint technology has been expanded to GNSS receivers: ebubble Tilt auto-measure Compensated points Improves field time efficiency by 30-50% automatic measurements and no leveling Enables traceability of pole tilt information Enables measuring points which were not directly accessible before

ebubble

ebubble An electronic bubble displayed on measure and stakeout forms in Trimble Access software

ebubble What Does It Do For You? No need to continuously monitor the display of the controller and the physical pole-bubble at same time Enables you to keep the pole more stable during measurement No need to be close to the pole Eliminates errors: Not properly calibrated physical bubbles Not temperature affected like physical bubble Traceability: records tilt data for every single measured point

ebubble Hardware and Environments Dual axis accelerometer Sense acceleration R10 leveling gravity Provides tilt information g Any environment is suitable for accelerometers (almost) These notes also count for tilt auto-measure (to follow)

ebubble Calibrations Why is calibration needed? To adjust and align dual axis accelerometer with local gravity field To ensure accuracy of tilt information (and stored with measured points) What if I don t calibrate? Degrades the accuracy of the measured coordinates

ebubble Calibrations How often is (re-)calibration needed? When: the R10 suffers severe abuse, e.g. pole drop you enter an area with significantly different local gravity conditions, e.g. a massive granite mountain reaching the user-defined calibration age limit current inside temperature of the R10 is more than 30ºC compared to the last calibration warning message shown

ebubble Calibrations Is there something I need to take care of while calibrating? Pole straightness: a bent pole will directly affect the accuracy of the calibration, especially when you use a different pole for the actual measurements Bubble reference: calibrate against properly calibrated physical bubble Pole stability: receiver should be as vertical and as stable as possible, a bipod (or similar) helps the most

ebubble Options and Calibrations

ebubble Options and Calibrations

ebubble Options and Calibrations Needed for ebubble and tilt auto-measure Needed for tilt compensated points

ebubble Options and Calibrations

ebubble Important note: Always operate the R10 with the LED panel facing towards you; this ensures that the ebubble acts in the same direction as a physical bubble does on a pole Traceability Jobs/Review Job

Tilt Auto-Measure

Tilt Auto-Measure An automated tilt-triggered point measurement

Tilt Auto-Measure What Does It Do For You? Uses ebubble to trigger a fully automated point measurement point measurement starts as soon as the R10 is level Speeds up the point measurement workflow, especially when there are a lot of points needed to be measured Eliminates the slight tilt deflection when pressing the Measure key helps keeping the pole 100% steady from the moment the measurement starts

Tilt Auto-Measure

Tilt Auto-Measure

Tilt Auto-Measure Options

Compensated Points

Compensated Points Measures points which compensate for a tilted pole (up to 15º)

Compensated Points What Does It Do For You? Uses internal tilt and compass sensors to determine the spatial relationship between the Trimble R10 and the tip of the survey pole Allows you to directly measure points which were not accessible before with GNSS receivers or only through time-consuming offsetting technique Eliminates the need of having the pole always level for measurements Saves you time-consuming getting the pole level set up

Compensated Points Hardware and Environments Magnetometer Senses any magnetic field: We want to sense earth s local magnetic field and compare to R10 internal magnetic model Good environment en.wikipedia.org Away from any metal objects or objects that generate magnetic fields Bad environment Vehicles & heavy machinery High voltage overhead or underground power lines Metal reinforced buildings and more.

Compensated Points Hardware and Environments

Compensated Points Calibrations Why is calibration needed? To determine the R10 s magnetic characteristics in the ideal earth s magnetic field in the area To align magnetic model with the axis of the R10 What if I don t calibrate? Tilt corrected coordinates will be wrong Degrades the accuracy of the measured coordinates

Compensated Points Calibrations How often is (re-)calibration needed? When you enter an area with a different local magnetic environment Otherwise the same rules apply as the tilt sensors for ebubble and tilt auto-measure NOTE: every time you recalibrate the tilt sensor, it invalidates the magnetometer model alignment and therefore a new calibration is needed Are there additional considerations I need to be aware of while calibrating? Stay far away from any magnetic disturbance! Calibrating the magnetometer near sources of magnetic disturbance does not "correct" for the interference caused by these objects!

Compensated Points Calibrations

Compensated Points Calibrations

Compensated Points Calibrations

Compensated Points Options and Calibrations Magnetometer calibration Magnetometer alignment

Compensated Points Can Trimble Access detect a bad environment? Yes: if the sensed local gravity field does not match the expected (model) gravity field, Trimble Access will show you Magnetic field disturbed

Compensated Points Traceability and magnetic disturbance

Compensated Points Magnetic disturbance 0-9: Correctly calibrated magnetometer and environment is free of magnetic interference 10-50: Magnetometer is not correctly calibrated AND / OR moderate magnetic disturbance in the environment Trimble Access will show warning in status line and ask for confirmation upon storing the point 51-99: Magnetometer is not correctly calibrated AND / OR severe magnetic disturbance in the environment Trimble Access will not be able to store the point unless the pole's tilt distance is <0.4inch (1 cm) of level

Examples of R10 with SurePoint

Examples of R10 with SurePoint

Examples of R10 with SurePoint

Examples of R10 with SurePoint

Examples of R10 with SurePoint

Examples of R10 with SurePoint

How Do You Achieve an Improved Workflow Efficiency? Make sure your ebubble is ON every time you measure a point Enable the following options in your Survey Styles or under Measure Points/Options: Tilt auto-measure Auto store point Auto abandon Zero key press for repeated point measurement

How Do You Achieve an Improved Workflow Efficiency? Auto store point automatically stores the point when the preset occupation time and precisions have been met

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency? Auto abandon automatically abandons points that experience excess tilt, or excess movement, during the measurement process and the process is restarted

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency? Start using compensated points : For difficult to access points no need to offset anymore Repeated topographic points eliminates leveling time

How Do You Achieve an Improved Workflow Efficiency?

How Do You Achieve an Improved Workflow Efficiency? If you follow these settings. You save approx. 30%-50% of your time by: Automatically triggering point measurements for each single point less button clicks for the same goals Not having to level the pole for every single point Points are more precise: Focus on one thing (ebubble only!) during measurement. No continuously swap monitoring of time to go and physical bubble. No pole deflection due to pressing buttons

Summary of Trimble SurePoint Faster data collection Measure points that were previously inaccessible Eliminate common sources of GNSS measurement error 100% traceability Reduce operator fatigue Improve operator safety

Find out more Visit our Partner Pavilion and see a demo of the R10 with SurePoint technology Chat with one of our friendly and helpful Trimble staff. They are happy to help and explain it to you

Thank you - Questions