CAD CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study



Similar documents
Prosthetic treatment planning on the basis of scientific evidence.

ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

TRI Product NewsFlash. December 2015

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

Restorative Guidelines

State-of-the-art for your prostheses

TITLE: Metal-Ceramic and Porcelain Dental Crowns: A Review of Clinical and Cost- Effectiveness

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

1- Fatigue-Resistance and Microleakage of CAD/CAM Ceramic and Composite Molar crowns

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Choosing the right type of abutment

Long-Term dental Implant Survival In Fully Endentulous Patients: A Month Follow-Up

Ridge Reconstruction for Implant Placement

Press Abutment Solutions

Osseointegrated implant connected with natural tooth using a semiprecision attachment: A clinical report

Aesthetics meets CAD/CAM in the dental surgery

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

IMMEDIATE CUSTOM IMPLANT PROVISIONALIZATION: A PROSTHETIC TECHNIQUE

IMPLANT DENTISTRY EXAM BANK

Seeing CAD/CAM in a new light.

SAME DAY VS. TRADITIONAL CROWNS. Which is the better choice? PRESENTED BY

Long-term success of osseointegrated implants

Resistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights

Milled Bar Overdentures-Protocol and Procedures

priti crown Your patients deserve you

BICON DENTAL IMPLANTS

CAD/CAM expands the scope of restorative dentistry

Implant Parts. A Radford Heath Guide 1

THE INFLUENCE OF COMPRESSIVE CYCLIC LOADING ON THE RETENTION OF CAST CROWN COPINGS CEMENTED TO IMPLANT ABUTMENTS

Modern Tooth Replacement Strategies & Digital Workflow

While the prosthetic rehabilitation of

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

education Although demographic factors and growing patient awareness of the benefits of dental implants

Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.

Richard P. Kinsel, DDS, a and Dongming Lin, DDS, MS, MPH b University of California, San Francisco, School of Dentistry, San Francisco, Calif

Reconstruction of the anterior maxilla with implants using customized zirconia abutments and all-ceramic crowns: a clinical case report

FABRICATING CUSTOM ABUTMENTS

Rehabilitation of Endondontically Failed Anterior teeth by Immediate Replacement and Loading of an Implant supported Crown: A Case Report.

All-on-4 treatment concept with NobelSpeedy Groovy

Implant Bar Overdenture Utilizing Locator Attachments

2016 Buy Up Dental Care Plan Procedure List

How to Achieve Shade Harmony With Different Restorations

A NE ALW L G T E H N ATE R G A LI TIO T N E R O S F DEN I T S A L N C OTE R G A O M L I D CS by Mark Gervais

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

ADA Insurance Codes for Laboratory Procedures:

Treatment planning for the class 0, 1A, 1B dental arches

Richmond Crown- A Conventional Approach for Restoration of Badly Broken Posterior Teeth

Comparison of survival and complication rates of toothsupported. fixed dental prostheses (FDPs) and implantsupported. crowns (SCs)

Zirconia implant abutments: A review.

More than a fixed rehabilitation.

Implants in your Laboratory: Abutment Design

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Peer Reviewed Bibliography

Accurate Transfer of Peri-implant Soft Tissue Emergence Profile from the Provisional Crown to the Final Prosthesis Using an Emergence Profile Cast

The Transition from Teeth to Implants and the Use of Post-ceramic Soldering

Retention of maxillary implant overdenture bars of different designs

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

The preservation or reproduction of a natural

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

Dental implants and Astra Tech

Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report

What is a dental implant?

Implants and all-ceramic restorations in a patient treated for aggressive periodontitis: a case report

Encode Impression System. Optimization By Design

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

Aesthetic resources in rehabilitation with implant-supported restoration in the anterior region: a clinical case

Abutment fracture in a bridge supported by natural teeth and implants

Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation

Together with Course Program 2014

Dental Implant Restoration

ATLANTIS abutments as individual as your patients

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Replacing Hopeless Retained Deciduous Teeth in Adults Utilizing Dental Implants: Concepts and Case Presentation

INSPIRED BY NATURE: CHRISTIAN FERRARI FULL FUNCTIONAL AND ESTHETIC MINIMALINVASIV RESTORATION USING IPS E.MAX CERAMICS

CEREC MUCH MORE THAN RESTORATIONS.

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Restoring missing teeth in the anterior maxilla with

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Accelerated Patient Rehabilitation

Computer Aided Designing-Computer Aided Milling in Prosthodontics: A Promising Technology for Future

Implant therapy using osseointegrated implants has

September 13-16, 2009

CAD/CAM technology supporting successful implant therapy

Class I and II Indirect Tooth-Colored Restorations

Regular C/X Prosthetics. Prosthetics

CDT 2015 Code Change Summary New codes effective 1/1/2015

Straumann. Time-tested

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

dental implants for tooth replacement be a confident you

ANNUAL INTERNATIONAL AESTHETIC WEEK

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

ZIRCONIA INFORMATION FOR DENTISTS. FAQ S from the dental practice ENGLISH

Transcription:

ADRF RESEARCH REPORT Australian Dental Journal 2009; 54: 12 16 doi: 10.1111/j.1834-7819.2008.01082.x CAD CAM to fabricate ceramic implant abutments and crowns: a preliminary in vitro study MA Alfarsi,* H Mehmet Okutan,à M Bickelà *College of Dentistry, King Khalid University, Saudi Arabia. School of Dentistry and Oral Health, Griffith University, Australia. àschool of Dentistry, The University of Queensland, Australia. ABSTRACT Background: This study evaluated the feasibility of fabricating implant abutments and crowns from pre-sintered feldspathic porcelain blocks using the chair-side CAD CAM, CEREC3D Ò system. Methods: Thirty-two implant analogues were divided into two groups. In the control group, prefabricated machined anatomical titanium (Ti) abutments were screw-retained to the analogues. In the test group, machined feldspathic porcelain abutments were cemented on prefabricated machined Ti links and screw-retained to the implant analogues. These feldspathic porcelain abutments were fabricated out of pre-sintered feldspathic porcelain blocks as duplicates of the abutments in the control group using the CAD CAM, CEREC3D Ò system. Thirty-two feldspathic porcelain crowns, also fabricated out of pre-sintered ceramic blocks, were then cemented with resin cement on all the abutments in both groups. All samples were subsequently subjected to fracture strength testing under static load. An unpaired t-test was used to compare fracture load values between the two groups. Results: The test group using feldspathic porcelain abutments and crowns showed statistically significant higher mean fracture strength than the control group with the Ti abutments and feldspathic porcelain crowns. Conclusions: This preliminary study showed that the chair-side CAD CAM technology can be utilized to fabricate customized ceramic abutments with their associated ceramic crowns using pre-sintered feldspathic porcelain blocks. Key words: Abutment, CAD CAM, ceramic, implant, prosthodontics. (Accepted for publication 8 July 2008.) INTRODUCTION Single tooth replacement with dental implants has become a routine dental treatment. Many studies have shown a success rate of more than 89 per cent over 10 years for implant-supported crowns, 1 with high levels of operator and patient satisfaction. 2 In the late 1990s, patient demand for rapid treatments to replace missing teeth prompted the development of techniques for immediate implant placement in fresh extraction sockets. Studies on immediate implant placement show success rates of 97 per cent over four years 3 with studies on the immediate loading of implants showing success rates of more than 90 per cent. 4 One drawback of these techniques is that patients still have to wait with or without temporary crowns until permanent crowns are fabricated and inserted. 5 Restoring natural teeth with ceramic crowns 5 can provide patients with more aesthetically pleasing restorations, with the strongest ceramics having comparable strengths to conventional ceramo-metallic alternatives. 6 Similarly, when ceramic abutments are used to restore single implants, highly aesthetic outcomes can be achieved, particularly when compared to conventional metal abutments. 7,8 Even though the strongest ceramics have lower fracture strengths when compared to their metallic counterparts, especially on oblique loads, 9 they still show acceptable clinical performance. 7 CAD CAM technology has proved its ability to fabricate prosthetic restorations with comparable quality to their counterparts fabricated with conventional techniques. 10,11 The expanding possibilities of CAD CAM allow fabrication of removable partial dentures, 12 complete denture teeth setup with virtual articulation, 13 implant-supported custom ceramic abutments 14 and implant-supported ceramic crowns on prefabricated Ti or ceramic abutments. 15 18 To date, however, there are no published data on utilizing chair-side CAD CAM technology to fabricate 12 ª 2009 Australian Dental Association

CAD CAM ceramic implant abutments implant-supported customized ceramic abutments with associated ceramic crowns from pre-sintered feldspathic porcelain blocks. Carrying out this procedure chair-side may offer a single-visit replacement of a missing tooth with an aesthetic permanent all-ceramic implant-supported crown. In addition, this procedure will save time and materials and, when combined with immediate loading of a dental implant, may fulfil the patient s demand of permanently replacing a missing tooth in only one visit. MATERIALS AND METHODS Thirty-two implant analogues (Neo system implant replica, Neoss Ò, UK) were embedded vertically in epoxy resin (Blue Star Ò, Dentalgeräte GmbH, Germany). They were then randomly assigned to two groups; a test and a control group with 16 samples each. A premolar implant configuration was used (Fig 1). In the control group, prefabricated anatomical Ti implant abutments (Neo Titanium prepable abutments, Neoss Ò, UK) were screw-retained to the implant analogues with Ti screws (Neo implant system laboratory screw, Neoss Ò, UK). In the test group, Neoss Ò Mono Neolinks Ò (Neoss Ò Neo Matrix System, Neoss Ò, UK) were screw-retained to the implant analogues using the same Ti screws (Fig 1). The Neolink Ò was dealt with as if it were a prepared tooth. Following the manufacturer s protocol of scanning a natural tooth, a digital impression of the Neoss Ò Neolink Ò was taken with the CEREC3D Ò intra-oral optical camera. Test n=16 CEREC abutments on Neolinks Implant analogues CEREC corwns Fracture test Control n=16 Titanium abutments Subsequently, using the CEREC3D Ò software (version 260 R2005), an abutment was designed to fit the Neolink Ò (Fig 2). The abutment was designed by a process called replication in order to copy the shape of the Ti abutments in the control group. The ceramic abutments were milled using pre-sintered feldspathic porcelain blocks (CEREC Ò VITABLOCS Ò Mark II, VITA Ò Zahnfabrik, Germany). Then they were etched (VITA Ò CERAMICS ETCH), treated with a singlecomponent silane-based coupling agent (VITASIL Ò, VITA Ò Zahnfabrik) and cemented to the Neoss Ò Neolink Ò with resin cement (PanaviaF Ò 2.0, Kuraray Medical Inc., Japan). To fabricate the ceramic crown, a second digital impression was taken of the previously milled and cemented ceramic abutment, as if it were a prepared tooth. The crown was CAD CAM fabricated using the same ceramic block. To finish off the procedure, the crown was cemented to the abutment with the same resin cement following the same cementing protocol. All specimens were loaded until fracture in a computer-controlled 4505 Instron machine (Instron Ò Corporation, Canton, MA, USA). Two layers of 0.3 mm thick tin foil were placed over the occlusal surfaces of the crowns to achieve an even stress distribution. 19 A perpendicular load was applied to the occlusal surface of the samples, with a crosshead speed of 1 mm min. The Instron computer software recorded the load required for fracturing the specimens (Table 1). Statistics For statistical analysis, an unpaired Student s t-test was used, with confidence intervals at 95 per cent considered statistically significant (p 0.05). RESULTS The test group using feldspathic porcelain abutments and crowns showed a higher mean fracture strength of 2.02 kn (± 0.95, S.D.). The control group with the Ti abutments and feldspathic porcelain crowns showed a mean fracture strength of 1.33 kn (± 0.52) (Fig 3). The difference between the two groups was statistically significant (p = 0.017) (Table 2). In both groups, only the ceramic components fractured with none of the Ti abutments fracturing (Fig 4). Fig 1. The study protocol and the two groups configurations. DISCUSSION This preliminary study utilized the chair-side CER- EC3D Ò system to fabricate custom feldspathic porcelain implant abutments and crowns. Although the laboratory version, CEREC Ò InLab Ò, is capable of fabricating such abutments, 14 the chair-side version is ª 2009 Australian Dental Association 13

MA Alfarsi et al. (a) (b) (c) Fig 2. (a) Screen captures of the ceramic abutment CAD designing procedure, (b) ceramic abutment design as a replica of the Ti abutment, and (c) the crown that was designed and milled the same way for both groups. Table 1. The recorded fracture loads 3.5 Control kn Test kn 0.52 0.24 0.73 0.26 0.92 1.14 0.94 1.22 0.99 1.76 1.00 1.82 1.01 1.88 1.15 2.10 1.27 2.22 1.41 2.35 1.62 2.36 1.71 2.62 1.81 2.76 2.00 2.81 2.00 3.00 2.27 3.77 FRACTURE LOADS IN kn 3.0 2.5 2.0 1.5 1.0 0.5 1.33 1.85 0.81 2.97 1.07 2.02 0.0 CONTROL TEST Fig 3. The mean and standard deviations of the two groups. The test group showed statistically significant higher fracture loads. not configured to do so. Since there are enough studies to support the use of the chair-side CEREC3D Ò system to fabricate high quality ceramic crowns, 10,18 the challenge was to adapt the chair-side CEREC3D Ò system to fabricate ceramic abutments. As there is no available abutments database for the chair-side CEREC3D Ò system, we had to manipulate the computer software to design an abutment. A process called replication was followed to design the abutments. The Ti abutments in the control group were copied in that process. There are several published case reports 16 19 on the use of the chair-side CAD CAM technology to fabricate ceramic implant-supported crowns, utilizing prefabricated Ti or ceramic abutments, in a single visit. Ti abutments are strong and predictable with aesthetically compromised outcome. 7,8 Ceramic abutments on the other hand, are more aesthetic with less, yet acceptable strength. 20,21 Both, however, may require manual grinding of the abutment to customize it which can be exhausting and time consuming. This study proposed a new technique to fabricate ceramic abutments using the chair-side CAD CAM technology. This procedure virtually eliminates the need for manual grinding of the abutment as all customization is performed during the design step on 14 ª 2009 Australian Dental Association

CAD CAM ceramic implant abutments Table 2. The statistical analysis. Student s t-test was used to compare the two groups Control Test Mean 1.33 2.02 95% confidence interval 0.94 thru 1.72 1.63 thru 2.41 for mean Standard deviation 0.52 0.95 Max 2.27 3.77 Median 1.21 2.16 Min 0.52 0.24 Average absolute deviation from median 0.43 0.72 Probability (p) 0.017 Fig 4. The static fracture test. The Instron machine with 5 kg cell is loading one of the control group specimens. None of the Ti abutments fractured. the computer screen. Thus, it is less exhausting to both the patient and the clinician. Since we had to manipulate the computer software to accept the abutment design, as mentioned earlier, the time required for designing and customizing the abutment, CAD portion, could not be calculated accurately. The time required to mill the abutment, CAM portion, was around 20 minutes. The CAD CAM of a crown consumed approximately 30 minutes as we used a premolar crown design from the available database. As an estimate, assuming we have an abutments database, the total procedure from imaging through to cementation can be carried out within one hour. The clinician s skill and training in the use of the CAD CAM machine has a huge impact on the time taken and the quality of the outcomes. Presence of a database for crowns was very helpful in reducing the amount of time needed for the CAD part. Screw-retaining a ceramic abutment to an implant is of concern. The retaining screw exerts a clamping force on the abutment to retain it, which may subject the ceramic to static stress leading to crack formation and eventual failure. 20 Ceramic abutment manufacturers have attempted to solve this problem and prevent such failures. Among those is Neoss Ò Company, with their Neolink Ò system. The Neolink Ò is a Ti connector with the purpose of forming an interface between the implant and the abutment. It is screw-retained to the implant. The screw is seated inside the Ti connector. As the ceramic abutment is cemented to the outer walls of the Neolink Ò, it is thus passively connected to the implant. 21 Also the Neolink Ò provided what the CEREC3D Ò recognized as a prepared tooth. This helped us in using the available software that only deals with natural teeth. Currently, the most successful ceramic implant abutments are zirconia (ZrO 2 ) ceramic abutments. 22 However, using a pre-made ZrO 2 block requires a sixhour sintering period at high temperature after milling as the ZrO 2 blocks are only partially sintered to enable easy and fast milling. 23 This prevents the single session fabrication of an abutment. To enable single session fabrication of the prosthesis, pre-sintered machineable feldspathic porcelain blocks were used to fabricate both the abutment and the crown. These blocks showed satisfying outcomes when used to fabricate crowns. 24,25 The static fracture strength test was used in this preliminary study to assess the validity of this new technique and the worthiness of developing it in more comprehensive studies using more clinically relevant criteria. 26 The aim was to investigate the fracture strength of the complete prosthesis fabricated with the proposed technique. Thus, the samples tested were complete prostheses, i.e. a feldspathic porcelain crown cemented to a feldspathic porcelain abutment cemented to a Ti link which was screwed to an implant. Since studies reporting the fracture strength of implant abutments investigate samples without crowns, i.e. abutments only, 27 direct comparison to this study was not possible. The statistically significant higher fracture strength values we encountered for the test group (2.02 kn) over the control group (1.33 kn) were not expected. In our belief, two factors may have enhanced the fracture resistance of the test group. The two layers of resin cements 28 and the larger bulk of the high quality porcelain. 24 More comprehensive studies are needed to clarify this. CONCLUSIONS This preliminary study showed that the chair-side CAD CAM technology can be utilized to fabricate customized ceramic abutments with their associated ceramic crowns using pre-sintered feldspathic porcelain blocks. This technique opens up the possibility of a new area for the application of the chair-side CAD CAM in implant dentistry. In addition, it promises for the single visit permanent replacement of a missing tooth. We recommend the need for future studies to further explore fatigue strength, marginal accuracy and adaptation. ª 2009 Australian Dental Association 15

MA Alfarsi et al. ACKNOWLEDGEMENTS M. Alfarsi was sponsored by a scholarship from King Khalid University. This research was part of his thesis submitted in partial fulfilment of the MDSc degree awarded in 2007 at The University of Queensland. This work was funded partly by Australian Dental Research Foundation grant number 32 2006, and Neoss Ò Australia. We appreciate the thoughtful editorial help provided by Dr Keith Doonan, Brisbane. REFERENCES 1. Bragger U, Karoussis I, Persson R, Pjetursson B, Salvi G, Lang NP. Technical and biological complications failures with single crowns and fixed partial dentures on implants: a 10-year prospective cohort study. Clin Oral Implants Res 2005;16:326 334. 2. Pjetursson BE, Karoussis I, Burgin W, Bragger U, Lang NP. Patients satisfaction following implant therapy. A 10-year prospective cohort study. Clin Oral Implants Res 2005;16:185 193. 3. Covani U, Crespi R, Cornelini R, Barone A. Immediate implants supporting single crown restoration: a 4-year prospective study. J Periodontol 2004;75:982 988. 4. Attard NJ, Zarb GA. Immediate and early implant loading protocols: a literature review of clinical studies. J Prosthet Dent 2005;94:242 258. 5. Raigrodski AJ. Contemporary materials and technologies for allceramic fixed partial dentures: a review of the literature. J Prosthet Dent 2004;92:557 562. 6. Pjetursson BE, Sailer I, Zwahlen M, Hammerle CHF. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns. Clin Oral Implants Res 2007;18:73 85. 7. Tan PLB, Dunne JT Jr. An esthetic comparison of a metal ceramic crown and cast metal abutment with an all-ceramic crown and zirconia abutment: a clinical report. J Prosthet Dent 2004;91: 215 218. 8. Schiroli G. Single-tooth implant restorations in the esthetic zone with PureForm ceramic crowns: 3 case reports. J Oral Implantol 2004;30:358 363. 9. Cho HW, Dong JK, Jin TH, Oh SC, Lee HH, Lee JW. A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns. Int J Prosthodont 2002;15:9 13. 10. Kelly JR. Developing meaningful systematic review of CAD CAM reconstructions and fiber-reinforced composites. Clin Oral Implants Res 2007;18(Suppl 3):205 217. Erratum in: Clin Oral Implants Res 2008;19:326 328. 11. Strub JR, Rekow ED, Witkowski S. Computer-aided design and fabrication of dental restorations: current systems and future possibilities. J Am Dent Assoc 2006;137:1289 1296. 12. Williams RJ, Bibb R, Eggbeer D, Collis J. Use of CAD CAM technology to fabricate a removable partial denture framework. J Prosthet Dent 2006;96:96 99. 13. Busch M, Kordass B. Concept and development of a computerized positioning of prosthetic teeth for complete dentures. Int J Comput Dent 2006;9:113 120. 14. Zöllner A, Benthaus K. CEREC labside implant restorations: custom-made abutments. In: Mörmann WH, ed. State of the art of CAD CAM restorations: 20 years of CEREC. UK: Quintessence Publishing, 2006. 15. Fritzsche G. Treatment of a single-tooth gap with a Cerec 3D crown on an implant: a case report. Int J Comput Dent 2004; 7:199 206. 16. Griffin JD Jr. Immediate definitive CAD CAM restoration of a non-submerged implant. Compend Contin Educ Dent 2005; 26:115 116, 118, 120 122 passim. 17. Petrungaro PS. Immediate one-stage implant placement and CAD CAM abutments for posterior restorations. Pract Proced Aesthet Dent 2003;15:595 599. 18. Hansen S. CEREC Chairside fabrication of suprastructures for immediately loaded implants. In: Mörmann WH, ed. State of the art of CAD CAM restorations: 20 Years of CEREC. UK: Quintessence Publishing, 2006:173 180. 19. Okutan M, Heydecke G, Butz F, Strub JR. Fracture load and marginal fit of shrinkage-free ZrSiO4 all-ceramic crowns after chewing simulation. J Oral Rehabil 2006;33:827 832. 20. Kern M. Clinical performance of all-ceramic restorations. In: Mörmann WH, ed. State of the art of CAD CAM restorations: 20 Years of CEREC. UK: Quintessence Publishing, 2006. 21. Neoss. http: www.neoss.com index.php?m=4&s=393&p=369. 2007. Access date: 9 June 2007. 22. Yildirim M, Fischer H, Marx R, Edelhoff D. In vivo fracture resistance of implant-supported all-ceramic restorations. J Prosthet Dent 2003;90:325 331. 23. Rego N. CAD CAM restorations: understanding the fabrication process. Dental Lab Products. March 2006. 24. Kelly R. Machinable ceramics. In: Mörmann WH, ed. State of the art of CAD CAM restorations: 20 years of CEREC. UK: Quintessence Publishing, 2006:29 38. 25. Zahran MH, El-Mowafy O, Tam LE, Watson PA, Finer Y. Fatigue resistance of all-ceramic molar crowns manufactured with CAD CAM technology. J Prosthodont 2008;17:370 377. 26. Kelly JR. Clinically relevant approach to failure testing of allceramic restorations. J Prosthet Dent 1999;81:652 661. 27. Butz F, Heydecke G, Okutan M, Strub JR. Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation. J Oral Rehabil 2005;32:838 843. 28. Fleming GJP, Maguire FR, Bhamra G, Burke FM, Marquis PM. The strengthening mechanism of resin cements on porcelain surfaces. J Dent Res 2006;85:272 276. Address for correspondence: Dr. Mohammed Alfarsi Centre for Medicine and Oral Health Griffith University 16 30 High Street Southport QLD 4215 Email: m.alfarsi@griffith.edu.au 16 ª 2009 Australian Dental Association