ALL-CERAMIC DENTAL IMPLANT SOLUTIONS



Similar documents
Implants of high-performance ceramic. vk-lange :44 Uhr Seite 1. One-piece precision implant. Made in Germany

Choose What Feels Right. Bridge vs. Dental Implant

IMPLANT DENTISTRY EXAM BANK

Standard Internal Hex

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

Modern Tooth Replacement Strategies & Digital Workflow

PureForm Ceramic System. Emulating nature. The perfect disguise.

World leading in innovative restorative and esthetic dental solutions.

Titanium versus Zirconium Implants

Implant Parts. A Radford Heath Guide 1

FABRICATING CUSTOM ABUTMENTS

Biomechanical and Clinical Attributes of Zirconia Dental Implants Two Case Reports

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Straumann Dental Implant System. Implant Selection Guide.

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

What Dental Implants Can Do For You!

Prosthodontist s Perspective

Restorative Guidelines

Renaissance of One-Piece Implants

Dental Laboratories. Procera provides you access to our multi-million dollar production facility

Like natural teeth. Treatment procedure with dental implants SINGLE TOOTH REPLACEMENT

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

NARROW DIAMETER implant

What is a dental implant?

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

More than a fixed rehabilitation.

WAX-UP AND CERAMIC EXTENSIVE COURSE Dr. Dario Adolfi Dr. Ivan Ronald Huanca

Gl GinGival level implant

priti crown Your patients deserve you

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

SAME DAY VS. TRADITIONAL CROWNS. Which is the better choice? PRESENTED BY

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

ATLANTIS abutments as individual as your patients

Rehabilitation of a complex case with zirconium dental implants

Press Abutment Solutions

Straumann Bone Level Tapered Implant Peer-to-peer communication

Full Crown Module: Learner Level 1

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

platform shifting Nobel Biocare is shifting gingival beauty to the next level

Restoring quality to life. Dental implants. A naturally better solution. Patient Education

How to Achieve Shade Harmony With Different Restorations

All-on-4 treatment concept with NobelSpeedy Groovy

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

Understanding Dental Implants

Simpl Implant Abutments with Atlantis CAD CAM Technology

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

dental implants for tooth replacement be a confident you

Dental implants and Astra Tech

DENT IMPLANT restoring qualit S: of LIfE

Like natural teeth. Treatment with dental implants is a safe, reliable and well-proven solution for permanently replacing one or more missing teeth.

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Guidance for implant removal. Straumann Dental Implant System

SAME DAY VS. TRADITIONAL CROWNS. Which is the better choice? PRESENTED BY

Company information for patients. More than Swiss precision. A better quality of life.

Structur. Structur 2 SC / Structur Premium EXCELLENT TEMPORARIES WITH STRUCTUR

Patient information on dental implants. More than just beautiful teeth. A comprehensive guide to dental implants.

PATIENT INFORM CONSENT for IMPLANT RESTORATION Rev

September 13-16, 2009

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Implant solutions. 3M True Definition Scanner. Precise. implant impressions. with incredible speed

Zirconium Abutments for Improved Esthetics in Anterior Restorations

dental implants for tooth replacement be a confident you

Bone augmentation procedure without wound closure

Dental Implant Options in Atrophic Jaws

procedures & products NOBELESTHETICS including Procera

The SATURN implant by Cortex Dental Industries

GINGIVAL LEVEL implant

Abutment Solutions For customized implant restorations fabricated with CEREC and inlab. Digital all around.

BICON DENTAL IMPLANTS

One Abutment - One Time

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

Implants in your Laboratory: Abutment Design

Straumann Dental Implants Confident smiles

PATIENT INFORMATION. A new quality of life with dental implants.

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

IMPLANT MENTOR PROGRAM

Regular C/X Prosthetics. Prosthetics

Procedures & Products Powered by Procera. All-on-4

Jacket crown. Advantage : Crown and Bridge

Dental Implants - the tooth replacement solution

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

High-Tech Ceramics Dental Implant System: Two Part Metal-Free Natural. User Manual. swiss made. giving nature a hand

Basic information on the surgical and prosthetic procedures. Straumann PURE Ceramic Implant


Implanting Brilliancy

Long-term success of osseointegrated implants

THE VOICE OF TECHNO-CLINICAL DENTISTRY

Removing fixed prostheses using the ATD automatic crown and bridge remover

While the prosthetic rehabilitation of

Procedures & Products. NobelEsthetics

Transcription:

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

Scientific Evidence Bone-to-implant contact of 78% at 3 months. One piece implant = no prosthetic connections References 1. One-year follow-up of first consecutive 100 zirconia dental implants in humans: a comparison of 2 different rough surfaces. Int J Oral Maxillofac Implants. 2007 May-Jun;22(3):430-5. 2. Erste klinishe Einjahresergebnisse von 100 Zirconoxidimplantaten. Ein Vergleich zwischen zwei unterschiedlich rauen Oberflächentypen. Implantologie 2007;15(4):429-436. 3. Zirconia implants and all-ceramic restorations for the aesthetic replacement of two central incisors.ejed 2008;3(2):175-185. 4. Ovoid Zirconia Implants: Anatomic Design for Premolar Replacement. Int J Period Rest Dent 2008; 28:609-615. 5. Ovale Zirkonoxidimplantate: Anatomisches Design als Ersatz für Prämolare. Int J Par Rest Zahn 2008;28:583-589. 6. Replacement of congenically missing maxillary permanent canine with a zirconium oxide dental implant and crown. A case report from an ongoing clinical study. Oral Surgery 2008;1(2):140-144. 7. Full mouth oral rehabilitation in a titanium allergy patient using zirconium oxide dental implants and zirconium oxide restorations A case report from an on-going clinical study. EJED; 2010 Summer; 5(2):190-203. 8. Five year success rate of first consecutive 831 zirconia dental implants in humans. A comparison of three different rough surfaces. JOMI 2010 Mar-Apr;25(2):336-44. Full articles available at: www.ceraroot.com/store/download/scientific-publications/

Company Oral Iceberg is a global leader in metal-free, holistic and esthetic implant dentistry. Having pioneered the latest research and developments in the field of zirconium oxide implant dentistry with the CeraRoot system, we have a philosophy of doing more to advance dental regeneration, restoration, and replacement, as well as patient care. With the CeraRoot implant system and CeraCrown prosthetic components, we deliver superior solutions that allow dental professionals to provide the best possible care to patients. Located in Barcelona, Spain, ORAL ICEBERG company is a global leader in zirconium oxide implant and restorative dentistry. Founded by Drs. Oliva in 1995, the company has experienced a great growth with the development of the CeraRoot zirconium oxide implant system and the CeraCrown prosthetic components. In collaboration with The Leading Dental Centers, research institutes and universities, we study and develop implants, prosthetic components and instruments for use in tooth replacement solutions. We also offer comprehensive training and services to the dental professionals worldwide, including training and education, which is provided in collaboration with the LDCW group. Our products are available worldwide through the online shop. Oral Iceberg encourages healthy living and social responsibility. ORAL ICEBERG, S.L. Josep Umbert, 128-08402 Granollers Barcelona - SPAIN Phone +34 938 614 841 Fax +34 938 792 373 www.ceraroot.com info@ceraroot.com Skype id: oral.iceberg ISO 13485 Our products are conformance with European Union regulations. K093595 Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician / dentist Health Canada 87566

Implants CeraRoot 12 FOR LATERAL OR LOWER INCISORS CeraRoot 21 FOR SMALL CENTRAL INCISORS AND CANINES CeraRoot 14 FOR PREMOLARS AND BICUSPIDS CeraRoot 11 FOR CENTRAL INCISORS AND CANINES CeraRoot 16 FOR MOLARS

Indications CeraRoot 12 CeraRoot 21 CeraRoot 11 CeraRoot 14 CeraRoot 16

Osseointegration The osseointegration that results from the enhanced bone formation and firm anchorage on Ice Surface is characterized by a remarkable bone-to-implant contact. Early loading is possible on CeraRoot implants when excellent stability is achieved in healthy patients with good bone quality. The unique properties of the Ice Surface accelerate the osseointegration process and achieve secondary stability sooner than machined or blasted surface ceramic implants. This means that early loading protocols can be achieved with more predictability thanks to earlier osseointegration. The latest clinical results on Ice Surface confirm exceptional maintenance of marginal bone level after 5 years. Ice Surface is currently being evaluated in several centers involving more than 800 CeraRoot implants placed in 378 patients. For the patient, this means the benefit of more bone more rapidly and the reliability of a long-term treatment outcome. CeraRoot is the first generation acid etched ceramic implant surface with more than 5 years clinical follow-up. The absence of a prosthetic connection due to its one-piece structure accelerates the healing process and preserves the surrounding bone.

Ice Surface is the first acid etched surface applied on a zirconium oxide ceramic implant. This new surface helps achieve optimal conditions for the integration between implant and bone and soft tissues. It is a rough surface especially designed for achieving faster and stronger osseointegration compared to machined zirconium oxide ceramic implants. The enhanced osseointegration and firmer anchorage in the surrounding tissues achieved with Ice Surface increase the predictability of implant treatment, especially in clinically demanding situations.

Mechanical Testing The strength and machining characteristics of yttrium reinforced - zirconium oxide (y-tzp) implants make this material ideal for the fabrication of durable, high-precision and highly esthetic ceramic implants and crowns. FIG. 1-30 0 Off-axis Fatigue Testing The material properties, in combination with the design and production process technology of the CeraRoot implant system, result in an excellent mechanical stability. To test the mechanical properties of the CeraRoot implant, fatigue strength testing according to the ISO 14801 standard was conducted. With 5 million validation cycles at 10 Hz at the same benchmark load as the titanium implants, the CeraRoot implant met all acceptance criteria. The angle of loading force was at 30º to the axis of the implant body (Fig.1). This test result show that the mechanical properties offered by implant type CeraRoot 11 indicated for Central Incisors and Canines has an excellent mechanical properties even in the most severe conditions. The simulation of 5.000.000 cycles is to simulate an oral environment function of about 20 years (Fig. 2). Zirconia has a flexural strength and fracture toughness almost twice as high as that of alumina, which makes zirconia very resistant to masticatory forces, while still maintaining an exact precision. These proven mechanical qualities allow the restorative team high flexibility for indication and application. Partially-stabilized zirconia powder with uniform dispersion of 3 mol % yttria exhibits superior sintering properties and higher aging resistance at a lower sintering temperature of 1350 0 C. Sintered bodies produced with primary powder show a fine crystal grain structure resulting in great improvements in strength, fracture toughness, as well as resistance to wear and aging. Zirconium Oxide has numerous applications such as materials for medical devices, industrial parts and everyday products. CeraRoot implants are manufactured with compositions according to ISO 13356. FIG. 2 - CeraRoot 11, Fatigue Test results Test with CeraRoot 11 Load (N) Nº. of cycles Static Mean of 3 implants 2730 1 Dynamic Mean of 8 implants 1967 5.000.000

the crown is available before the implant is inserted All CeraRoot implants have been designed to avoid any preparation of the abutment and prosthetic shoulder part. That is why each implant has its own indication. This makes zirconia stronger over time and provides a perfect fit between the implant and the crown. The professional can grind or polish the crown to its final shape and send it to the lab to be finished with porcelain layers or over-pressing technique. The CeraCrown can be used as: Impression coping Temporary crown Zirconia crown core CeraCrown 12 CeraCrown 21 CeraCrown 11 CeraCrown 14 CeraCrown 16 These products are intentionally designed to be easy to use in your daily practice. Combining the finest dental prosthetics with the world s only industrialized process customized crowns, we ensure you really can deliver functionality and esthetics to all your patients. CeraRoot s unique CeraCrown technology offers esthetic and functional dental restorations for all teeth. Based on the latest manufacturing technologies, the CeraCrown system provides completely individualized prosthetics with unbeatably precise fit for crowns. A combination of biocompatibility, beauty, and strength is guaranteed. Zirconia refracts and transmits light in much the same way as a natural tooth, thereby giving the restoration a natural looking appearance. In fact, the end result is often an improvement on nature. In thin periodontium type, the white body of the implant is never visible through the gum. Beautiful gingiva. Best biomaterials, surface, design and procedures created for maintaining and regaining natural soft tissue. Supra or paragingival cementation of the crowns has never been easier. CeraRoot 16 CeraCrown 16 Crown finished Assembling of CeraRoot and CeraCrown

Drill Sequence CeraRoot 12 FOR LATERAL OR LOWER INCISORS 1) pilot drill 2) 2.3 mm 3) 2.8 mm 4) 3.5 mm 5) 4.2 mm (only the first 3 mm) NO countersink! ATTENTION: Do NOT exceed 35N of torque during insertion of implant CeraRoot 21 FOR SMALL CENTRAL INCISORS AND CANINES 1) pilot drill 2) 2.3 mm 3) 2.8 mm 4) 3.5 mm 5) Countersink 21 ref. 004.021 CeraRoot 14 FOR PREMOLARS AND BICUSPIDS 1) pilot drill 2) 2.3 mm 3) 2.8 mm 4) 3.5 mm 5) Countersink 14 ref. 004.014 CeraRoot 11 FOR CENTRAL INCISORS AND CANINES 1) pilot drill 2) 2.3 mm 3) 2.8 mm 4) 3.5 mm 5) 4.2 mm 6) Countersink 11 ref. 004.011 CeraRoot 16 FOR MOLARS 1) pilot drill 2) 2.3 mm 3) 2.8 mm 4) 3.5 mm 5) 4.2 mm 6) Countersink 16 ref. 004.016

Instruments Implants SURGICAL PARTS Reference Description 001.001 Initial bur 2mm (triangle shaped) 001.002 Twist drill 2.3mm - steel 001.003 Twist drill 2.8mm - steel 001.004 Twist drill 3.5mm - steel 001.005 Twist drill 4.2mm - steel 001.006 Bur extension 001.007 Right-angle/Handpiece adapter 4x4 002.002 Twist drill 2.3mm - ceramic 002.003 Twist drill 2.8mm - ceramic 002.004 Twist drill 3.5mm - ceramic 002.005 Twist drill 4.2mm - ceramic 003.016 Countersink 16 - steel 003.011 Countersink 11 - steel 003.021 Countersink 21 - steel 003.014 Countersink 14 - steel 004.016 Countersink 16 - ceramic 004.011 Countersink 11 - ceramic 004.021 Countersink 21 - ceramic 004.014 Countersink 14 - ceramic 005.114 Mallet for implant 14 005.214 Impactor for implant 14 005.016 Transporter 16 Long- steel 005.017 Transporter 16 Short- steel 005.011 Transporter 11- steel 005.021 Transporter 21- steel 005.012 Transporter 12- steel 006.016 Transporter 16 Long- zirconia 006.017 Transporter 16 Short- zirconia 006.011 Transporter 11- zirconia 006.021 Transporter 21- zirconia 006.012 Transporter 12- zirconia 020.001 Big Surgical cassette empty 020.003 Small Surgical cassette empty 020.004 Ceramic tray 50x75 for disposal of drills 020.007 Surgical Kit with steel drills/instruments 020.008 Surgical Kit with ceramic drills/instruments 005.500 Steel Tweezers with zirconia tips 030.001 Torque Wrench 35N - titanium 030.002 Adapter 4x4 SHORT for Torque wrench 030.003 Adapter 4x4 LONG for Torque wrench 030.004 Torque Wrench Kit (030.001+ 030.002 + 030.003) 030.005 NobelBiocare adapter 030.006 Straumann adapter Reference Description CeraRoot 16 FOR MOLARS *a c s 160.010 CeraRoot 16 L= 10 mm 4.8-6.5-8 160.012 CeraRoot 16 L= 12 mm 4.8-6.5-8 160.014 CeraRoot 16 L= 14 mm 4.8-6.5-8 CeraRoot 11 FOR UPPER CENTRAL INCISORS AND UPPER CANINES 110.010 CeraRoot 11 L= 10 mm 4.8-6 - 6.5 110.012 CeraRoot 11 L= 12 mm 4.8-6 - 6.5 110.014 CeraRoot 11 L= 14 mm 4.8-6 - 6.5 CeraRoot 21 FOR UPPER CENTRAL INCISORS AND CANINES 210.010 CeraRoot 21 L= 10 mm 4.1-4.8-6 210.012 CeraRoot 21 L= 12 mm 4.1-4.8-6 210.014 CeraRoot 21 L= 14 mm 4.1-4.8-6 CeraRoot 14 FOR BICUSPIDS/PREMOLARS AND LOWER CUSPIDS 140.008 CeraRoot 14 L= 8 mm 3.5-4.8-5 140.010 CeraRoot 14 L= 10 mm 3.5-4.8-5 140.012 CeraRoot 14 L= 12 mm 3.5-4.8-5 140.014 CeraRoot 14 L= 14 mm 3.5-4.8-5 CeraRoot 12 FOR UPPER LATERAL AND LOWER INCISORS 120.010 CeraRoot 12 L= 10 mm 4.1-4.1-4.1 120.012 CeraRoot 12 L= 12 mm 4.1-4.1-4.1 120.014 CeraRoot 12 L= 14 mm 4.1-4.1-4.1 *a --> diameter of implant at apical level c --> diameter of implant at bone crest level s --> diameter of implant at shoulder level Drawings of parts are available on the website PROSTHETIC PARTS Reference Description 007.016 CeraCrown 16 - zirconia coping white color 017.016 CeraCrown 16 - zirconia coping A1 color 027.016 CeraCrown 16 - zirconia coping A2 color 007.011 CeraCrown 11 - zirconia coping white color 017.011 CeraCrown 11 - zirconia coping A1 color 027.011 CeraCrown 11 - zirconia coping A2 color 007.021 CeraCrown 21 - zirconia coping white color 017.021 CeraCrown 21 - zirconia coping A1 color 027.021 CeraCrown 21 - zirconia coping A2 color 007.014 CeraCrown 14 - zirconia coping white color 017.014 CeraCrown 14 - zirconia coping A1 color 027.014 CeraCrown 14 - zirconia coping A2 color 007.012 CeraCrown 12 - zirconia coping white color 017.012 CeraCrown 12 - zirconia coping A1 color 027.012 CeraCrown 12 - zirconia coping A2 color 008.116 Lab Analogue 16 for CeraRoot 16 - zirconia 008.111 Lab Analogue 11 for CeraRoot 11 - zirconia 008.121 Lab Analogue 21 for CeraRoot 21 - zirconia 008.114 Lab Analogue 14 for CeraRoot 14 - zirconia 008.112 Lab Analogue 12 for CeraRoot 12 - zirconia

CERAROOT TRAINING Visit www.ceraroot.com for available courses ORAL ICEBERG, S.L. Josep Umbert, 128-08402 Granollers Barcelona - SPAIN Phone +34 938 614 841 Fax +34 938 792 373 www.ceraroot.com info@ceraroot.com Skype id: oral.iceberg ISO 13485 Our products are conformance with European Union regulations. K093595 Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician / dentist Health Canada 87566 02/2012-009.150