AudiaVOIP. Operation Manual



Similar documents
MCA Series Multi-Channel Amplifiers. Operation Manual

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

IMPORTANT SAFETY INSTRUCTIONS

DATA SHEET TESirAFOrTÉ Ai TESirAFOrTÉ AVB Ai

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

Digital Satellite Receiver

Model PS-4001 Power Supply User Instructions

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

VoiceTone T1 USER S MANUAL

ZaapTV HD509N. User s Guide. How to use the HD509N set-top box

User Manual DIGITAL MONITOR SPEAKERS MS /MS. 24-Bit/192 khz Digital 40/20-Watt Stereo Near Field Monitors

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Spider IV 15. Pilot s Handbook Manuel de pilotage Pilotenhandbuch Pilotenhandboek Manual del Piloto 取 扱 説 明 書

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

dedicated KVM switch and rackmount screen technology User Manual IP-S101 Combo KVM Extender Designed and manufactured by Austin Hughes

The Bouncer Bluetooth Stereo Speaker

Fast Track Solo Guide

TABLETOP CONTROLLER USER'S MANUAL

Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export

2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X

Operation Manual. Multi Channel Power Amplifier DPA-430L

ES-3305P V2 / ES-3308P V2. Quick Installation Guide / v1.0

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

VOIP Business Phone User Guide

Power Supply Guide Version 1.0 for D-Show

igroove SXT Owner's Manual

DMX USB PRO. User Manual.

Universal Host. Desktop Digital Hybrid. User Guide. JK Audio

WAVE BLUETOOTH MUSIC ADAPTER

QUICK INSTALLATION. 8-Port Telephony Gateway. Model: SPA8000

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

Tone Hammer 500. Owners Manual. Manual Version 1.0

C24-CAMANL Video Server/Encoder

BroadBand PowerShield. User Manual

Kinivo 301BN HDMI Switch

undx2io 2-in/2-out Dante Wallplate


MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

User Guide USB 2.0 LAPTOP DOCKING STATION WITH VIDEO N2953

Focusrite Saffire 6 USB. User Guide

HDVD 800. Pure audio in perfection. Instruction manual

VS-0202 VS User Manual

HD udta Quick-Start Guide

2 series II COMPANION MULTIMEDIA SPEAKERS

DIGITAL CABLE TV RECEIVER OPERATION MANUAL DVB-C8080AL DIGITAL CABLE RECEIVER DEAR CONSUMER

USER MANUAL VS92A / VS94A / VS98A

DVI Video Splitter USER MANUAL VS-162 / VS-164

INSTRUCTION MANUAL MODEL PCD-88

8-Port PoE Network Switch

PB-1000 SB-1000 POWERED SUBWOOFERS OWNER S MANUAL

ATA User Manual. iinet ATA Telephone Adapter. Setting up for ADSL and VoIP. For model F1PG200ENau

PoE+ Extender Switch User's Manual. Rev W

8-Port HDMI Switch USER MANUAL VS0801H

ANTENNA DISTRIBUTION SYSTEM USER'S GUIDE

Advantium 2 Plus Alarm

Gateway Port Replicator User Guide

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio

innkeeper PBX Desktop Digital Hybrid User Guide JK Audio Warranty

User guide Conference phone Konftel 100

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LabelWriter. Print Server. User Guide

HDMI Matrix Switch USER MANUAL VM0404H

CMP30. User Manual.

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

IFS SP-PoE Splitter User Manual

7 High-Resolution Digital Photo Frame

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

Wave/PC Interactive System USB Adapter Kit. Installation Guide

HP-1000E v2. User s Manual. Powerline Ethernet Adapter. HP1000E v2 User s Manual

FB-500A User s Manual

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Caller-ID on your TV!

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Gigabit Ethernet Switch 10/100/1000 Mbps GS605 / GS608. Installation Guide

StructureScan HD Module. Installation Guide ENGLISH

aseries A13B Mini Bullet Camera User Manual

PRO MPA II. ART PRO MPA II Microphone Preamplifier USER S GUIDE

User and Installation Guide

USB 2.0 to 10/100Mbps Ethernet Adapter UE User Manual

Congratulations on your HomePortal purchase. To install your HomePortal and configure your home network, follow these steps.

To Purchase This Item, Visit BMI Gaming (800) Owner s Manual

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

300Mbps Wireless-N Access Point/Repeater

USER GUIDE LOUDBOX MINI

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

OWNER S MANUAL PB-2000 SB-2000 POWERED SUBWOOFERS

reflecta Super 8 Scanner

IP Box Camera ACM Ver Hardware User s Manual

Zetron Desktop Microphone Manual F

4 Port VGA Video Audio Switch with RS232 control

Neets Control SieRRa II. Installation Manual

How To Use A Fortivoice Phone On A Cell Phone On An Ipad Or Ipad (For A Sim Sim) On A Simplon (For An Ipod) On An Iphone Or Ipod (For Ipad)

COMPANION 2 Series II MULTIMEDIA SPEAKERS

Transcription:

AudiaVOIP Operation Manual July 2012 Biamp Systems, 9300 SW Gemini Drive, Beaverton, Oregon 97008 U.S.A. (503) 641-7287 www.biamp.com

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. 5) Do not use this product near water. 6) Clean only with dry cloth. 7) Do not block ventilation openings. Install in accordance with the manufacturer s instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other product (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong. The third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the product. 11) Only use attachments/accessories specified by the manufacturer. 12) Use only with equipment rack, cart, stand or table designed to provide adequate mechanical strength, heat dissipation and securement to the building structure. When a cart is used, use caution when moving the cart and product combination to avoid injury from tip-over. 13) Unplug this product during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the product has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the product, the product has been exposed to rain or moisture, does not operate normally, or has been dropped. WARNING - To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. WARNING - This product employs Safety Grounding and must be connected to a MAINS socket that is properly grounded to provide a protective earthing connection. WARNING Speaker terminals marked with the symbol are Hazardous Live. External wiring connected to these terminals requires installation by qualified electrical installer. Disconnect Device - The MAINS plug is used to disconnect MAINS power and must remain readily operable. Explanation of safety related symbols - Product labeling and the operation manual may use the internationally recognized symbols defined below to note safety messages. Lightning Bolt: Hazardous Live voltages present when this unit is in operation. Do not touch terminals marked with this symbol while the unit is connected to live power. Exclamation Point: Replace components (i.e. fuses) only with the values specified by the manufacturer. Failure to do so will compromise safe operation of this unit. Important Safety Instructions_Speaker Terminals 2

TABLE OF CONTENTS AUDIAVOIP.... 4 Features.... 4 REAR PANEL... 5 Preloaded DAP File... 5 Card Configuration................................................ 5 EXAMPLE CONFIGURATION.... 6 CONNECTING TO A NETWORKED SYSTEM.... 7 ASSIGNING DIFFERENT IP ADDRESSES... 12 AUDIAVOIP SPECIFICATIONS.... 13 Block Diagram.... 13 WARRANTY... 14 FCC COMPLIANCE... 15 EC DECLARATION... 16 EU ROHS COMPLIANCE... 17 3

AudiaVOIP AudiaVOIP AudiaVOIP is a dedicated version of AudiaFLEX NC, the benchmark in digital audio systems for demanding professional sound installations. AudiaVOIP provides the same easy- to- use software and functional algorithms, available in AudiaFLEX with the added ease of a predefined fixed I/O configuration and factory loaded DAP file optimized for VoIP teleconferencing. The intuitive software provides audio system design capabilities via PC computer, and allows easy selection, viewing, and calibration of numerous audio components: mixers, combiners, matrixes, equalizers, filters, crossovers, dynamics, routers, delays, remote controls, meters, generators, diagnostics, etc. Once a system design is compiled, it is downloaded into AudiaVOIP, where it can then be controlled via third- party systems such as AMX and Crestron, via davinci software, and/or via dedicated Audia remote control panels. For more complete instructions, see the software Help file or the printable Help document. FEATURES Sona Acoustic Echo Cancellation (AEC) Comes preconfigured with: 12 AEC inputs 4 mic/line inputs 4 line outputs 2 amplified outputs 2 VoIP lines Configuration/control via PC/laptop Remote control panels for levels, presets, etc. Third-party control via RS-232 Built-in diagnostic tools Remote function control via Ethernet CE marked, UL listed and RoHS compliant Covered by Biamp Systems five year warranty Ability to select, view and calibrate: Mixers standard, automatic, matrix, combiners Equalizers graphic, parametric, feedback Filters HPF, LPF, high shelf, low shelf, all-pass Crossovers 2-way, 3-way, 4-way Dynamics leveler, comp/limiter, ducker, ANC Routers 2x4 ~ 56x56 Delays 0 ~ 2000ms Controls levels, mutes, presets, schedulers, logic gates, RS-232 commands, etc. Meters signal present, peak, RMS Generators tone, pink noise, white noise Diagnostics transfer function 4

RISK OF ELECTRICAL SHOCK. DO NOT OPEN. AudiaVOIP REAR PANEL AudiaVOIP 100-240V~ 50/60Hz Serial Control Port CAUTION BIAMP SYSTEMS Made in USA, US and Imported Parts www.biamp.com 150 Watts CobraNet connections only primary secondary in use / conductor link / activity LEDs In 21 Out 3 In 22 In 19 Out 5 In 20 In 17 Out 7 In 18 link/act full duplex In 15 Out 9 In 16 In 13 Out 11 In 14 In 11 Out 13 In 12 In 9 Out 15 In 10 In 7 Out 17 In 8 In 5 Out 19 In 6 In 3 Out 21 In 4 In 1 Out 23 In 2 U.S. pat. no. 4,922,536 24VDC 1.5A Out 4 Out 6 Out 8 VoIP Out 10 Out 12 Out 14 Out 16 Out 18 Out 20 Out 22 Out 24 52SJ Model: Audia link Ethernet term hi lo Remote Control Bus N24138 class 2 wiring YELLOW connectors = AMP OUTPUTS BLACK connectors = OUTPUTS ORANGE connectors = AEC INPUTS GREEN connectors = INPUTS AudiaVOIP comes preconfigured with 4 mic/line inputs, 12 AEC inputs, 4 line outputs, 2 amplified outputs and 2 VoIP lines. The device comes preloaded with a default software configuration file that is able to be customized to meet a wide range of applications. Preloaded DAP File Card Configuration The fixed configuration is achieved with the following cards: Card Slot Channel Default Software Configuration file connection Input Output IP-2 1 1 Program Left 2 Program Right IP-2 2 3 Codec Receive Left 4 Codec Receive Right AEC-2HD 3 5 Room Microphone 1 6 Room Microphone 2 AEC-2HD 4 7 Room Microphone 3 8 Room Microphone 4 AEC-2HD 5 9 Room Microphone 5 10 Room Microphone 6 AEC-2HD 6 11 Room Microphone 7 12 Room Microphone 8 AEC-2HD 7 13 Room Microphone 9 14 Room Microphone 10 AEC-2HD 8 15 Room Microphone 11 16 Room Microphone 12 VoIP-2 9 17 17 VoIP Telephone Line 1 18 18 VoIP Telephone Line 2 OP-2e 10 19 Codec Transmit Left 20 Codec Transmit Right OP-2e 11 21 Auxiliary Output A 22 Auxiliary Output B PA-2 12 23 4 or 8 Ω Room Speakers Channel 1 24 4 or 8 Ω Room Speakers Channel 2 5

LEDs in use / conductor link / activity RISK OF ELECTRICAL SHOCK. DO NOT OPEN. EXAMPLE CONFIGURATION Third Party Control System Graphical User Controls Serial Port for interface to external control systems: Can receive control information (controlling dialer, room levels, etc.) Send serial strings to other devices (control lighting and camera systems, etc.) 2 VoIP extensions for internal and external telephone conferencing (Sona AEC processing removes all echo from audio delivered to callers) VoIP Network Audio inputs from video codecs Presentation audio sources (PC, DVD, Projector Audio) 100-240V~ 50/60Hz Serial Control Port CAUTION BIAMP SYSTEMS Made in USA, US and Imported Parts www.biamp.com 150 Watts primary CobraNet connections only secondary In 21 Out 3 In 22 In 19 Out 5 In 20 In 17 Out 7 In 18 link/act full duplex In 15 Out 9 In 16 In 13 Out 11 In 14 In 11 Out 13 In 12 In 9 Out 15 In 10 In 7 Out 17 In 8 In 5 Out 19 In 6 In 3 Out 21 In 4 In 1 Out 23 In 2 U.S. pat. no. 4,922,536 24VDC 1.5A Out 4 Out 6 Out 8 VoIP Out 10 Out 12 Out 14 Out 16 Out 18 Out 20 Out 22 Out 24 52SJ Model: Audia link Ethernet term hi lo Remote Control Bus N24138 class 2 wiring YELLOW connectors = AMP OUTPUTS BLACK connectors = OUTPUTS ORANGE connectors = AEC INPUTS GREEN connectors = INPUTS Ethernet Control Interface Audia DSP programming interface Interface to external control systems Interface to Biamp controllers, davinci, RED-1 or ipad Dialer App Audio outputs to video codecs (Sona AEC Processing removes all echo from audio delivered to far end) Audio outputs to recorders, external amplifiers, etc. RED-1 Control Network Two 30W speaker circuits. Direct drive 4, 6, or 8Ω speakers or 70/100V distributed circuits (external transformers required) 6

CONNECTING TO A NETWORKED SYSTEM 1. Install Audia software on a Windows PC. Download from here: http://www.biamp.com/products/audia/downloads.aspx 2. Minimum PC requirements: Windows 7 (32-bit), Vista (32-bit), or XP Professional SP2/SP3 (32-bit) 256MB RAM Pentium 4 1.5GHz or faster 10/100 Base-T Ethernet Card 1280x1024 screen resolution (recommended) 3. Assign an IP address to the PC. The PC must have a unique IP address before it can communicate with an Audia device. Please note that AudiaVOIP does not support DHCP or Zero Conf (Link Local) addressing. Windows XP users: Go to Control Panel > Network and Internet > Network Connections. Confirm the Local Area Connection you will be using. Right click and select Properties. Windows 7 users: Go to Control Panel > Network and Sharing Center. Click on Local Area Connection. 7

CONNECTING TO A NETWORKED SYSTEM The Local Area Connection Status Dialog will open. Select Properties. The Local Area Connection Properties Dialog will open. Double-Click Internet Protocol Version 4 (TCP/IPv4). 8

CONNECTING TO A NETWORKED SYSTEM The Internet Protocol Version 4 (TCP/IPv4) Properties will open. Update the IP address and Subnet mask to the same range as the AudiaVOIP default. The IP address should be 192.168.1.x (x=1-254). Subnet mask should be 255.255.255.0. Click OK when complete. Close Network. 4. Connect the PC to the network. There are two ways to connect a PC and AudiaVOIP system together. Direct connection: Attach a crossover Ethernet cable from the PC s 10/100 Base-T network card to the AudiaVOIP Ethernet port. You can easily determine if an Ethernet cable is a crossover by looking at the conductors on the RJ-45 connectors. If the wiring of pins 1,2, 3 and 6 is different on both ends, it is a crossover Ethernet cable. 9

CONNECTING TO A NETWORKED SYSTEM Connecting via Ethernet switch: Attach a straight-through Ethernet cable from the PC s 10/100 Base-T network card to a 10/100 Base-T Ethernet switch. Straight-through Ethernet cables connect transmit pins directly to receive pins (pin 1 to pin 1, pin 2 to pin2, pin 3 to pin3, etc.). You can easily determine if an Ethernet cable is straightthrough by looking at the conductors on the RJ-45 connectors. If the wiring is identical on both ends, it is a straight-through Ethernet cable. 5. Power up Audia devices. Connect the supplied power cord to a grounded AC mains voltage of 100-240VAC @50/60Hz. Connect the other end of the power cord to the power entrance located on the rear of the Audia unit. Note the status of the front panel LED s. Under normal conditions, all LED s will remain green once power-up sequence has completed. 6. Connect the Audia device to the network. Direct connection: Attach a crossover Ethernet cable from the PC s 10/100 Base-T network card to the AudiaVOIP Ethernet port. You can easily determine if an Ethernet cable is a crossover by looking at the conductors on the RJ-45 connectors. If the wiring of pins 1,2, 3 and 6 is different on both ends, it is a crossover Ethernet cable. Connecting via Ethernet switch: Attach a straight-through Ethernet cable from the PC s 10/100 Base-T network card to a 10/100 Base-T Ethernet switch. Straight-through Ethernet cables connect transmit pins directly to receive pins (pin 1 to pin 1, pin 2 to pin2, pin 3 to pin3, etc.). You can easily determine if an Ethernet cable is straightthrough by looking at the conductors on the RJ-45 connectors. If the wiring is identical on both ends, it is a straight-through Ethernet cable. 7. Configure NIC in the Audia software. Open Audia software and select the correct network interface card. From the Audia menu go to Tools > Options. Click on the Network tab, then press Select NIC. 10

CONNECTING TO A NETWORKED SYSTEM 8. Connect to the network with Audia software. Open the Audia software. Connect to the network by going to File > Network > Connect to network. Select the required device listed in the System List and press Connect to System. The software will connect and allow real time user control. When required changes have been made, disconnect the PC from the Audia system by going to File > Network > Disconnect from Audia system. Finally, disconnect the PC from the network by going to File > Network > Disconnect from network. 11

ASSIGNING DIFFERENT IP ADDRESSES All AudiaVOIP units ship from the factory with an assigned IP address of 192.168.1.101. When using more than one device in a system, each device must have a unique IP address. Audia device IP addresses must be different from any IP address that will be used in this system. AudiaVOIP does not support DHCP or Zero Conf (Link Local) addressing. Please note that adjusting Audia IP addresses will stop system audio. 1. In the Audia software, go to File > Network > Connect to network. 2. Once you are connected, go to File > Network > Perform Audia Device Maintenance > Select desired Audia device > Set IP address. 3. Update the IP Address, Subnet mask and Gateway values to the new settings. 4. Click OK when complete. 5. Close Device Maintenance when complete. 6. Connect to the system and restart the audio. Note: To avoid conflict issues that occur when connecting multiple Audia devices with the same IP number, be sure to only connect one Audia device at a time to the Ethernet switch when assigning IP addresses. 12

AudiaVOIP SPECIFICATIONS AudiaVOIP SPECIFICATIONS Frequency Response (20Hz~20kHz @ +4dBu): +0/-0.4dB Phantom Power: +48 VDC (7mA/input) THD+N (20Hz~20kHz @ +4dBu): line level < 0.006% mic level < 0.04% Input Gain Range (variable trim): Sampling Rate: 0dB ~ +66dB 48kHz EIN (20Hz~20kHz, 66dB gain, 150Ω): -125dB A/D - D/A Converters: 24-bit Dynamic Range (20Hz~20kHz, 0dB): > 107dB Power Consumption (100~240VAC 50/60Hz): < 150 watts Maximum Gain (input channels): Crosstalk (channel-to-channel @ 1kHz): line level mic level Output Impedance (balanced): 66dB < -80dB < -75dB 200Ω Dimensions: height width depth Weight (max. - fully loaded with PA-2 cards): 3.5 inches (89mm) 19 inches (483mm) 11.15 inches (283mm) 15.25 lbs. (6.9kg) Input Impedance (mic/line balanced): Maximum Output (balanced): Maximum Input (mic/line): 8kΩ +24dBu +24dBu Compliance: AES48-2005 Grounding & EMC practices EU Directive 2002/95/EC, RoHS directive CE marked UL / C-UL listed AudiaVOIP AudiaFLEX BLOCK DIAGRAM TCP/IP Control Comms Remote Control Bus RS-232 MicroProcessor Memory CobraNet Control Comms Analog Inputs A/D DSP Cluster D/A Analog Outputs 13

WARRANTY BIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMENT DESCRIBED IN THIS MANUAL 1. BIAMP Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BIAMP Systems dealer, subject to theterms and conditions set forth below. 2 If you notify BIAMP during the warranty period that a BIAMP Systems product fails to comply with the warranty, BIAMP Systems will repair or replace, at BIAMP Systems option, the nonconforming product. As a condition to receiving the benefits of this warranty, you must provide BIAMP Systems with documentation that establishes that you were the original purchaser of the products. Such evidence may consist of your sales receipt from an authorized BIAMP Systems dealer. Transportation and insurance charges to and from the BIAMP Systems factory for warranty service shall be your responsibility. 3. This warranty will be VOID if the serial number has been removed or defaced; or if the product has been altered, subjected to damage, abuse or rental usage, repaired by any person not authorized by BIAMP Systems to make repairs; or installed in any manner that does not comply with BIAMP Systems recommendations. 4. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. All server-based devices are warranted for 3 years only. 5. This warranty is in lieu of all other warranties, expressed or implied. Biamp Systems disclaims all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. 6. The remedies set forth herein shall be the purchaser s sole and exclusive remedies with respect to any defective product. 7. No agent, employee, distributor or dealer of Biamp Systems is authorized to modify this warranty or to make additional warranties on behalf of Biamp Systems. Statements, representations or warranties made by any dealer do not constitute warranties by Biamp Systems. Biamp Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. 8. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty. 9. Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use arising out of the purchase, sale, or use of the products, even if BIAMP Systems was advised of the possibility of such damages. 072012_585.0381.90A 14

FCC COMPLIANCE FCC NOTICE - CLASS B DIGITAL DEVICE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in either a residential or commercial installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) Reorient or relocate the receiving antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected or 4) Consult the dealer or an experienced radio/tv technician for help. 15

COMPLIANCE DoC DSPA201207 EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that our delivered version the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. Any alterations to the product not agreed upon and directed by Biamp Systems Corporation will invalidate this declaration. Brand Name: Audia Product Description: Audio Digital Signal Processors and Control Accessories DSP Models: AudiaFLEX CM, AudiaFLEX NC, AudiaFUSION, AudiaSOLO 4X12, AudiaSOLO 8X8, AudiaSOLO 12X4, AudiaVOIP AudiaFLEX I/O Cards: AEC-2HD, IP-2, OP-2e, PA-2, TI-2, VoIP-2 AudiaFUSION Amplifier Cards: AM-600, AM-600c Low Voltage Accessories/Controls: LOGIC BOX, NPS-1, RED-1, RED-1F, RCB HUB, RP-L1, RP-L2, RP-S4, SELECT 8, VOLUME 8, VOLUME/SELECT 8, VCB Applicable EC Directives: Applicable Harmonized Standards: LVD Directive (2006/95/EC) Safety EN 60065:2002 IEC 60065:2001 + Amd 1:2005 EMC Directive (2004/108/EC) Emissions EN 55103-1:1996, Environment E2 Immunity EN 55103-2:1996, Environment E2 R&TTE Directive (1999/5/EC) Terminal Equip. TBR-21 (AudiaFLEX with TI-2 only) RoHS Directive (2011/65/EU) RoHS Recast Special Considerations for Product Environment or Compliance: Shielded cabling must be used for system connections. DSP Platform provides Low Voltage Limited Energy for controls. RED-1, RED-1F, use only CE marked Power over Ethernet (PoE) device. Technical Documentation File, Location and Contact: Biamp Systems Corporation phone: (503) 641.7287 9300 S.W. Gemini Drive fax: (503) 626.0281 Beaverton, OR USA 97008 e-mail: compliance@biamp.com Authorized Representative: Larry Copley, Compliance Engineer Authorized Signature: Date and Place Issued: March 2010, Beaverton, Oregon USA Revised: July 2012 16

COMPLIANCE RoHS COMPLIANT This Biamp product, including all attendant cables and accessories supplied by Biamp, meets all requirements of EU Directives 2002/95/EC of January 27, 2003, and 2005/618/EC of August 18, 2005, the EU RoHS Directives. An EU RoHS Materials Content Declaration document may be obtained at www.biamp.com The following information is presented to comply with the requirements of Chinese law SJ/T11363-2006 有 害 物 质 表 (Hazardous Substances Table) Biamp Systems Corporation 数 字 信 号 处 理 器 (Digital Signal Processor) 型 号 AudiaVOIP Pb 铅 有 毒 有 害 物 质 或 元 素 (Substances) Hg Cd Cr+6 PBB PBDE 汞 镉 六 价 铬 部 件 名 称 (Part Name) 设 备 机 箱 (Equipment Chassis) X O X O O O 电 源 线 (Power Cord) O O O O O O 插 拔 式 接 线 端 子 (Plug-in Terminal Blocks) O O O O O O 手 册 和 其 他 书 面 文 档 (Manual and Paper Documents) O O O O O O 包 装 箱 和 所 有 包 装 材 料 (Box and Packing Materials) O O O O O O 0: 表 示 该 部 件 所 有 均 质 材 料 中 的 这 种 有 毒 有 害 物 质 低 于 SJ/T11363-2006 的 限 制 要 求. X: 表 示 该 部 件 中 至 少 有 一 种 均 质 材 料 所 含 的 这 种 有 毒 有 害 物 质 高 于 SJ/T11363-2006 的 限 制 要 求. 在 电 触 头 和 ( 或 ) 镀 镉 所 含 的 均 质 材 料 中, 镉 及 其 化 合 物 的 含 量 可 以 超 过 0.01%, 但 欧 盟 指 令 91/338/EEC( 根 据 欧 盟 指 令 76/769/EEC) 限 制 销 售 和 使 用 某 些 危 险 物 质 和 制 剂 部 分 中 所 禁 止 的 用 途 除 外 在 以 下 一 种 或 多 种 物 质 所 含 的 均 质 材 料 中, 铅 及 其 化 合 物 的 含 量 可 以 超 过 0.1%: 1) 电 子 元 器 件 中 玻 璃 内 所 含 的 铅 2) 铅 在 钢 材 中 是 作 为 一 种 合 金 元 素, 含 量 可 达 0.35% 3) 铅 在 铝 材 中 是 作 为 一 种 合 金 元 素, 含 量 可 达 0.4% 4) 铅 在 铜 材 中 是 作 为 一 种 合 金 元 素, 含 量 可 达 4% 5) 高 熔 点 类 焊 料 中 的 铅 ( 即 铅 料 合 金, 铅 含 量 超 过 85%) 6) 电 子 陶 瓷 部 件 内 的 铅 7) 由 两 种 以 上 元 素 组 成 的 焊 料 中 所 含 的 铅, 用 于 连 接 针 脚 和 微 处 理 器 包 装, 其 中 铅 的 含 量 超 过 80% 但 低 于 85% 8) 顺 应 针 连 接 系 统 内 的 铅 9) 倒 装 芯 片 封 装 中 半 导 体 芯 片 及 载 体 之 间 形 成 可 靠 连 接 所 用 焊 料 中 的 在 正 常 使 用 情 况 下, 中 国 环 保 使 用 期 限 为 10 年, 条 件 是 : 环 境 温 度 为 (Ambient Temperature) 0-40C (32-104 F) 湿 度 为 0-95%, 无 凝 结 海 拔 高 度 为 0-10,000 英 尺 气 流 不 受 阻 碍 没 有 水 或 其 他 液 体 进 入 任 何 部 件 电 源 为 100-240 Vac, 50/60 Hz; 150W (Power Supply) 部 件 没 有 损 坏 ( 损 坏 部 件 应 立 即 修 理 ) 由 工 厂 授 权 人 员 使 用 批 准 的 材 料 进 行 所 有 维 修 17