DIRECT STRIKE PROTECTION. CAT Terminal, Gold, Model III



Similar documents
SURGE PROTECTIVE DEVICES

Power surges can also be generated by equipment in your facility such as:

Telecommunication Line Protectors

1. Franklin Rod Performance 2. LEC/DAS Performance

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

SANS : 2008 CODE OF PRACTICE THE WIRING OF PREMISES Part 1 : Low Voltage Installation

Unified requirements for systems with voltages above 1 kv up to 15 kv

Grounding Demystified

Gas Discharge Tubes GTCX26-XXXM-R05 Series

Current Probes. User Manual

Security Cameras, CATV, GPS & Satellite Protection. White Paper

Waveguide Access Point WGA631. Product Guide

Research RF Sputtering Packages

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Reliability in Surge Protection. Security Systems.

428 MY HOME Structured cabling system for the home sector

CATALOGUE SURGE PROTECTION LOW VOLTAGE

Good EMC Design Principles: cable routing

CODE OF PRACTICE FOR EARTHING AND BONDING SYSTEM FOR SIGNALLING EQUIPMENTS SPECIFICATION NO. RDSO/SPN/197/2008 SIGNAL DIRECTORATE

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Video Camera Installation Guide

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

Gas Discharge Tubes GTCX36-XXXM-R05 Series

Power over Ethernet plus Isolation requirements. David Law 3Com

Wireless Broadband Surge Protection

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Technical Data. Dimensions

ALARMLINE ANALOGUE Linear Heat Detection System

How to design SMPS to Pass Common Mode Lightning Surge Test

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Quick Connect. quick - simple - efficient.

Rack mounted telephone- and leased line modem for industrial applications

ELEMKO reserves the right to modify, add or remove any information included in this catalogue, if necessary. Every updated version of the catalogue

Gas Discharge Tubes GTCX38-XXXM-R10 Series

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

RCD Inspection Log Book

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

LC/LCD ranges level controllers

Features. Picture. Specifications

R.C.C.B. s two-pole LEXIC

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Liquid Level Limit Switch liquiphant T FTL 20

MTL Surge Technologies. Product Overview

contents my HOmE - STrUCTUrEd CaBLing SYSTEm FOr THE HOmE SECTOr

Mitel DECT Base Stations

Consultants Handbook

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

EMC Engineering Guidelines For Automation Systems PS 4 PS /97 AWB GB

LOXONE 12 Channel Amplifier

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

ADM1TE 5/30A DIN rail single phase two wire energy meter

Introduction to Data Centre Design

Thyristor-controlled power supplies and battery chargers

Cable Guide. Cables, Connectors & Tools for installation of quality networks. TRIAX - your ultimate connection

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

Technical Article MS-2443

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

T Substation Maintenance and Commissioning Test Equipment

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

Operating Instructions

E-STOP relays, safety gate monitors

Intersection Preassembled 19-inch Rack

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Current Monitoring Kit QUICK START GUIDE

Contact expansion modules

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Application Guide to RF Coaxial Connectors and Cables

SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits

Telephone- and leased line modem for industrial applications TD-36

AMP CO Plus Insert for Cat. 6 A Applications

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Current Monitoring Kit

IP DSLAM IDL Quick Installation Guide

Guide to the electrical parameter classifications of IEC and IEC safety standards

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

White Paper: Electrical Ground Rules

5SV Residual Current Protective Devices

Vibration Monitoring System Adash 3600

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Model RI ICE Pack Impressed Current Electronic Package the remedy for Mag headaches Typical Applications:

Bourns Resistive Products

Cables. Accessories. For Force, Torque and Strain Sensors

A series of technology briefs spanning Tyco Electronics product portfolio

Structured Cabling, Earthing & Equipotential Bonding

INTERNATIONAL STANDARD

Series 510 Submersible Level Transmitters

Transcription:

Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd is a fully owned Australian manufacturer and supplier of direct strike lightning, surge and transient protection equipment and earthing products to a wide range of industries throughout the world. LPI s 4-Step Approach to Lightning Protection It is the strategic aim of our company to be able to provide a complete packaged solution. LPI has identified 4 key steps when considering the complete approach to lightning protection. Our system design approach includes: 1 Definition and provision of area protection 2 Creation of a bonded earthing system 3 Protection of power lines 4 Protection of signal, data and communication lines DIRECT STRIKE PROTECTION CAT I-G CAT II-G CAT III-G CATIGI-G HVSC-PM LSR 1 STORMASTER-ESE-15 STORMASTER-ESE-15-GI STORMASTER-ESE-30 STORMASTER-ESE-30-GI STORMASTER-ESE-50 STORMASTER-ESE-50-GI STORMASTER-ESE-60 STORMASTER-ESE-60-GI LWS LWS - Tester CAT Terminal,, Model I CAT Terminal,, Model II CAT Terminal,, Model III CAT Terminal for connection to 2 inch GI Pipe,, Model I High Voltage Shielded Cable per metre Lightning Strike Recorder Stormaster, ESE 15, Air Terminal, Stormaster, ESE 15, Air Terminal,, GI Connector Stormaster, ESE 30, Air Terminal, Stormaster, ESE 30, Air Terminal,, GI Connector Stormaster, ESE 50, Air Terminal, Stormaster, ESE 50, Air Terminal,, GI Connector Stormaster, ESE 60, Air Terminal Stormaster, ESE 60, Air Terminal,, GI Connector * Stainless steel Stormaster ESE terminals available upon request Lightning Warning System LPI s Lightning Warning System is designed for the early warning of an approaching storm front. The LPI LWS sounds an alarm on the approach of a lightning discharge and allows all personnel to take precautionary action to protect themselves from the dangers of a lightning discharge. Lightning Warning System Lightning Warning System Tester Guardian Lightning Protection System 5 LPI s Guardian System 5 provides a purpose designed package for direct strike lightning protection Family of Controlled Advanced Triggering Terminals (CAT) with the design based on the latest research High Voltage Shielded Cable (HVSC) is a purpose designed insulated downconductor which greatly reduces the risk of side flashing Lightning Strike Recorder (LSR 1) to effectively count strikes captured by the Guardian System The Guardian System 5 is an economical and simple to install solution Installations in over 20 countries worldwide Tested in compliance to IEC Test Standard: IEC 60-1:1989 Stormaster ESE Air Terminal LPI offers a selection of models from within it s ESE range of terminals All terminals have been tested to standard NFC 17-102 Economical and easy to install LPI also offers an extensive range of conventional lightning protection products and accessories. Contact LPI or an authorised representative for product details. Suitable Applications include sporting events such as golf and football, mining, defence and explosive environments Detects lightning activity within approximately 15 km Warning and alert status All clear signal

EARTHING AND B ONDING LPI provides an extensive range of earthing products for the installation of a low impedance earthing system. Whether you are installing a dedicated lightning earth or a facility earth grid it is essential to ensure personnel safety and provide an effective earth which will limit disruptions to services. LPI Exoweld The use of LPI EXOWELD exothermic welding process is a safe and efficient way of providing a permanent connection between conductors. LPI EXOWELD connections will not corrode or rust with age No water ingress like bolt type, crimping and compression connections Current carrying capacity equal to that of the conductor Economical and simple to install Contact LPI or an authorised representative for details on the LPI EXOWELD range of products. Earth Rods and Accessories LPI offers a range of earthing products and accessories as part of its packaged solution for the complete approach to lightning protection. The LPI range includes a complete selection of copperbonded steel earth rods, clamps, tapes, braids and pre-engineered ground grids and meshes. Contact LPI or an authorised representative for details on our full range of earth rods and accessories. Earth Enhancing Compounds LPI offers a selection of earth enhancing compounds for the treatment of soil in and around an earthing system to reduce the soil resistivity and lower ground impedance. Ground Resistance Improvement Powder (GRIP) is supplied in 10kg and 40kg kits and is particularly effective in difficult sites such as sandy soils and rocky ground. LPI RESLO is an economical treatment compound which is supplied in 10kg bags and is best suited to sites where excessive soil resistivity is not considered a problem. GRIP-10 GRIP-40 RESLO-10 Ground Resistance Improvement Powder 10kg Ground Resistance Improvement Powder 40kg Resistance Lowering Compound 10kg Bag Independent test reports available Transient Earth Clamp The LPI Transient Earth Clamp provides equipotential bonding under transient conditions by forming a closed circuit, whilst remaining in open circuit under normal operating conditions. The TEC should be used where separate earthing systems are installed. Ordering Code Transient Earth Clamp, TEC100 DC Sparkover voltage >350V DC, Impulse Current (limp) 100kA 10/350µs Max discharge current (Imax) 150kA 8/20µs Insulated Joint Protector The LPI Insulated Joint Protector is designed for the protection of insulated joints in oil and gas pipelines. The IJP is connected directly across the insulated joint, should the insulated joint voltage exceed the breakdown voltage of 350V the IJP will immediately conduct the surge current to ground. Ordering Code Insulated Joint Protector, IJP100 DC Sparkover voltage >350V DC, Impulse Current (limp) 100kA 10/350µs Max discharge current (Imax) 150kA 8/20µs Type approval: II 2GD EEx m II T3 Earth Bars and Inspection Pits EPIT-P EB400 DL-4751 DL-5502 Polymer Earth Pit, Rated + 5 Tonne Earth Bar, 400mm x 80mm x 98mm, 6 Way Disconnecting Link, 6 Way earth bar, 475mm x 80mm x 98mm, single disconnect link Disconnecting Link, 6 Way earth bar, 550mm x 80mm x 98mm, twin disconnect links * Contact LPI or an authorised representative for details on the full range of LPI earth bars and inspection pits.

SHUNT POWERLINE PROTECTION LPI offers a wide selection of technologies and products which are available for transient protection of the mains power supply at the point of entry to your facility. These products / technologies are represented in two categories - shunt protection and series protection. Ideal for robust equipment such as air conditioning, pumps and motors Point of entry protection Energy diversion only, voltage clamping devices installed between each phase and neutral or earth on mains switch board Class I Protectors, (Spark Gap based) per IEC 61643 SGT50-25 SG60 NE100 Din Mount Spark Gap L-N, L-E protection, 240VAC Nominal, 50kA 10/350µs Din Mount Spark Gap L-N, L-E protection, 440VAC Nominal, 60kA 10/350µs Din Mount Spark Gap N-E protection, 240VAC Nominal, 100kA 10/350µs Single phase and Three phase protectors fitted into steel enclosures (IP55) are available as 1PPM and 3PPM. Ask LPI for further details. Class II Protectors, (MOV based) per IEC 61643 SST150 SS140-275 SS140-480 3XSS140-275+NE15 Din Mount, L-N, L-E protection, 240VAC Nominal, (385V Uc), 50kA 8/20µs Din Mount L-N, L-E protection, 110-240VAC Nominal, (275V Uc), 40kA 8/20µs Din Mount L-N, L-E protection, 240VAC Nominal, (480V Uc), 40kA 8/20µs Din Mount 3 phase L-N and NE protection, 110-240VAC Nominal, (275V Uc), 40kA 8/20µs SST150, and both SS140 products all contain changeover alarm contacts and indicators. The 3XSS140-275+NE15 only has indicators (no alarms contacts).

SERIE S POWERLINE PROTECTION Series Powerline Protection, is the best available protection for sensitive electronics such rectifiers, switchmode power supplies, and other mission critical equipment. The Series Filter reduces the rate of rise of any transient overvoltage to acceptable levels, and also reduces the overall magnitude of the transient voltage the equipment receives. Low Current Single Phase Filters PLSF-6A PLSF-10A PLSF-16A Power line surge filter, 1 Ph, Din Mount, 240V AC, 3 Mode L-N, L-E, & N-E protection, 10kA 8/20µs Primary Protection per mode, 5kA 8/20µs Secondary Protection per mode, 15kA N-E Protection Variants available with 6A, 10A, 16A load current capacity Single and Three Phase Surge Filters Standard Surge Filter Order code: SF X YY A-NE Where X is number of phases, and YY is circuit current rating per phase. Other voltages available on request. Standard Surge Filter specifications: All units can withstand overvoltage and fault conditions in accordance with IEC 61643 requirements. All units incorporate non saturating inductors combined with high reliability capacitors to form an effective low pass filter, incorporating shunt protection elements on the line and load sides. Number of Current Phases X Rating YY 1 or 3 32A, 63A Surge filter with Class II protection applied P-N, 100kA 8/20µs line side protection, 50kA 8/20µs load side protection per phase. 100kA 10/350µs N-E 1 or 3 125A, 200A Surge filter with Class I protection applied P-N, 50kA 10/350µs, 135kA 8/20µs line side protection, 50kA 8/20µs load side protection per phase. 100kA 10/350µs N-E 3 315A, 400A, Surge filter with Class I protection applied P-N, 50kA 10/350µs, 135kA 630A, 800A, 8/20µs line side protection, 50kA 8/20µs load side protection per phase. 1000A, 1250A 100kA 10/350µs N-E TELECOMMUNIC ATION PROTECTION Din Mount Data and Telephone Line Protectors D2 Series : D2XYY Where X is the operating current and YY is the nominal operating voltage. D2 Series Din Mount Data Protectors Operating Current X Nominal Operating Voltage YY D = 300mA 06, 15, 30, 50, 100 H = 1250mA 06, 15, 30, 50, 100 V = 4000mA 06, 15, 30, 50, 100 * For example: D2H15 = D2 Series Protector, Operating current =1250mA, Nominal Operating Voltage = 15V. * Consult Technical Data Sheet for detailed specifications. D3 Series Din Mount Telephone Line Protectors D3TA D3T Telephone Line Protector, ISDN / ADSL / PCM Circuits, Operating Current 140mA, 20kA 8/20µs, Single Pair Telephone Line Protector, Analogue Circuit, Operating Current 120mA, 20kA 8/20µs, Single Pair D2 Series Surge Current Rating 20kA (8/20µs), DIN mount & suitable for protection of signal & data-lines for computer, data communication, instrumentation, broadcasting and industrial control interfaces. D2 Series used directly with EIA Standard interfaces RS-232, RS422, RS-423, RS-485 and with 4-20mA instrumentation loops. D3TA - DIN mount telephone line protector, suitable for ISDN, ADSL and PCM circuits. D3T - DIN mount telephone protector suitable for analogue phone lines.

TELECOMMUNIC ATIONS PROTECTION Telephone and Data Line Protectors TLP-K10 VHS-K10-72 VHS-K10-230 Telephone Pair Protector, 10 Pair, 1 MHz, 144kbits/s, 190V, a+b+e 20kA 8/20µs, Multistage, Krone LSA Very High Speed, 10 Pair, 12 MHz, 8Mbits/s, 72V, a+b+e 20kA 8/20µs, Multistage, Krone, LSA Very High Speed, 10 Pair, 12 MHz, 8Mbits/s, 230V, a+b+e 20kA 8/20µs, Multistage, Krone, LSA Telephone and Data Line Protection Multistage / over voltage protection Plugs directly into a Krone disconnect block 10 Line and single line protected KRONE, KRONE LSA and PROFIL are registered Trade Marks of KRONE GmbH Germany. Protection of RF Feeder Cables & High Speed Coaxial Cable Data Lines For protection against transients on coaxial antenna RF feeder cables RF-NMF-90 RF Protector, 20kA, 72V 108V, N Type M to F Simple plug in installation RF-BNC-90 RF Protector, 20kA, 72V 108V, BNC Type M to F High impulse rating of 20kA 8/20µs RF-NB-90 RF Protector, 20kA, 72V 108V, N Type F to F (Bulkhead) Characteristic impedance: 50 Ohms RF-NMF-350 RF Protector, 20kA, 280V 420V, N Type M to F and 75 Ohms where applicable RF-BNC-350 RF Protector, 20kA, 280V 420V, BNC Type M to F RF-NB-350 RF Protector, 20kA, 280V 420V, N Type F to F (Bulkhead) RF-NMF-600 RF Protector, 20kA, 480V 720V, N Type M to F RF-BNC-600 RF Protector, 20kA, 480V 720V, BNC Type M to F RF-NB-600 RF Protector, 20kA, 480V 720V, N Type F to F (Bulkhead) CF-90 RF / High Speed coaxial cable data line protector, 90V, 20kA, 75 Ohms C75-BNC90 CCTV Circuit, 20kA, 90V, 75 Ohm, BNC Type GSM 7/16F-7/16F GSM Protector, 20kA, 50V, 50 Ohms, Frequency range 890 960 MHz, Female to Female* GSM 7/16M- 7/16F GSM Protector, 20kA, 50V, 50 Ohms, Frequency range 890 960 MHz, Male to Female* * 1800 & 1900 MHz versions available on request. Computer & Data Equipment Protectors RS232 9-9 Pin RS232 9-9 Pin (9 Pin Protected), 50A 10/1000 Wave Shape RS232 25-9 Pin RS232 25-9 Pin ( 9 Pin Protected), 50A 10/1000 Wave Shape RS232 25-25 Pin RS232 25-25 Pin (25 Pin Protected), 50A 10/1000 Wave Shape RS422 25-25 Pin RS422 25-25 Pin (25 Pin Protected), 50A 10/1000 Wave Shape Local Area Network Protector LAN RJ45 Cat6 LAN, RJ45, 100 Base T Protector, Cat 6 Load Cell Protector ILC36V Load Cell Surge Protector, 4 or 6 wire application, 36V High performance surge protectors for computers, terminals and printers Moulded construction Low clamping voltage Standard RS-232C Male / Female 9 & 25 pin Simple Plug in operation CAT 6 / 1000Mbits application Low Attenuation Compact Design Designed for protection of sensitive strain gauge measuring equipment Protects against excitation overvoltage Low capacitance Disclaimer LPI maintains a policy of on-going product development, specifications are subject to change without notice. Application detail, illustrations and schematic drawings are representative only and should be used as guides. It should be noted that 100% (100 percent) protection level for direct strike lightning and surge and transient protection equipment is not possible and cannot be provided due to the lightning discharge process being a natural atmospheric event. Copyright 2007 Lightning Protection International Pty Ltd. LIGHTNING PROTECTION INTERNATIONAL PTY. LTD. ABN 11 099 190 897 16 Mertonvale Circuit, Kingston Tasmania, Australia 7050. Telephone: + 61 3 6227 1955 Facsimile: + 61 3 6229 1900 Email: info@lpi.com.au Web: www.lpi.com.au BR-SUM-V6