HEAVY WATER LEAK DETECTOR



Similar documents
OPL BASIC. Dosing System for Professional Laundry machines. Contents

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT

Centro-Matic Automatic Lubrication Systems System Controls

Ammonia Detection System Codes and Design Specifications

HVAC Processes. Lecture 7

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electric Flow Boiler

Power consumption (kw)

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

How To Use A Power Supply Unit (Upu)

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Sanitary Type Electronic Flow Switches

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Model: DC-A2IO Advanced HVAC Controller

Adsorption air dryers ADS 1 215

TMS TANK MANAGEMENT SYSTEM

RRV934. Multi-controller. Synco living

Streaming Potential System (SPT1000, SPD1000)

Water Leak Detection System

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

LC/LCD ranges level controllers

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

User s Manual AURORA 1.2K/2.2K

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

EQUIPMENT SPECIFICATIONS

S300 Series Dust Monitors

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

Rackmount Intelligent Pressure Scanners

PBX Series Quick Fit Connector Bimetallic Steam Traps

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Oil and Coolant Circulating Heating System. Model - OCSM

NMC Pro System Manager

Conventional Fire Detection and Extinguishant Control System Specification

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

PRODUCT PROFILE FEATURES

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

Inova SV125 Machine Number

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

Fundamentals of Mass Flow Control

Morrison Bros. Co. General Product Specifications

Application Note. ipix A Gamma imager to support various applications

Micro Motion 3098 Gas Specific Gravity Meter

SMART SENSOR COLLECTION

PART 1 - INTRODUCTION...

The On-Board Refueling Vapor Recovery (ORVR) Evaporative Emission (EVAP) system.

Fire Pump Controllers Remote Alarm Panels

Butterfly Valves PN 6/10/16 for flanged connection

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Fire Alarm System Monitoring - CAN/ULC-S561-03

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

ECOCIAT. Domestic hot water heat recovery unit

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Module 6 Engine Control Module (ECM)

Triple Waveband Infra-Red Flame Detection

IRT Eurocard. Types DAX-3200

TTC-IIS Series Up to 11 LPM Free Flow

Electronic Flow Switches

ARB AIR LOCKER Air Operated Locking Differentials

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Solenoid valves 2/2-way direct-operated Type EV210A

Series 510 Submersible Level Transmitters

ORGANIC SAMPLE PREPARATION

The L&J Engineering Model MCG 1500SFI Servo Gauge

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Turbocharger system components, servicing

Typical Aluminum GFM Mass Flow Meter

Technical Guide 08/15/14

A Practical Guide to Free Energy Devices

In-Line Electronic Flow Switches

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Kompressoren. Adsorption Dryer AD

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

ThermoSorb Desiccant Dryers

Medical Air Systems: Scroll

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

DLP-PU/E Instruction Manual

The Axial Flow Valve. Class 300/ SERIES

HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS

Thyristor-controlled power supplies and battery chargers

Transcription:

HEAVY WATER LEAK DETECTOR WEB www.overhoff.com

MODEL 1925 HEAVY WATER LEAK DETECTOR (HWLD) LOW LEVEL REAL TIME TRITIUM-IN-WATER MONITOR This monitor has been designed for real time low-level detection of tritium in water in the industrial environment of nuclear power plants. Low MDA, reliability, ruggedness and simplicity of operation is what sets this monitor apart from laboratory type of the equipment. The primary purpose of the Model 1925 is to detect the leak of heavy water in nuclear power plants that utilize CANDU reactors; however, it can be used for other purposes such as monitoring changes in tritium content of ground water, rivers, lakes or ocean currents. MINIMUM DETECTABLE ACTIVITY (MDA) The unit detects tritium decay with Photo Multiplier Tubes (PMT) working in coincidence mode. Use of highly effective PMTs, specially designed sampling cell to minimize cosmic radiation and Cherenkov effects and 1 lead shielding provide for low background noise of only one count per second with a counting efficiency of 30%. MDA is 3.7kBq/L. RESPONSE TIME The unit is equipped with up to 6 inputs for sampling 6 individual lines. The response time from when sample enters the system until the unit starts to respond is 3 minutes and in 9 minutes the full value of tritium concentration in the sample is displayed on the screen. Each sample line is sampled for 10 minutes so that the effect of residual activity from the previous line is minimized. REMOTE MONITORING AND ALARMING The instrument is equipped with 4-20mA output for remote monitoring as well as with 2 alarm outputs and malfunction outputs in the form of dry, fail-safe, relay contacts. Alarms are adjustable and by default are set at 100kBq/L (Hi Alarm) and 110kBq/L (Hi-Hi Alarm). HWLD:PAGE 1

DATA RECORDING The instrument is equipped with Serial Data Recorder that utilizes Microdrive card to store up to five years worth of readings in daily files. This information is in text format that is easily extractable to Excel for analysis and graphic presentation. PRESSURE REGULATING EQUIPMENT Pressure of input sample streams can be up to 103 kpa. This pressure is immediately reduced to 2-3psi via Pressure Regulating Valves (PRV). Each PRV is associated with Pressure Relieve Valve set to open at 100 kpa, therefore, the pressure in the system can never be more than 100 kpa, which makes it safe to handle. This also makes the instrument Class 6 Nuclear Device. FULLY INTEGRATED PACKAGE Model 1925 is a completely self-contained instrument for real time observation of tritium concentration in water. The instrument is mounted inside of the 200cm tall steel enclosure with reinforced anchoring feet and locked access. Liquid scintillator is connected to the unit externally and it is stored inside of the polyurethane drum of 23 liters. This quantity of liquid scintillator is sufficient for 60 days of continuous, 24/7 operation. The main subassemblies are: 1. Sample water input lines 2. External cooling loop input/output lines 3. Internal cooling loop complete with chiller, chiller pump and plumbing 4. PRV and RV system with manifolds 5. Water purification system (oil-in-water and micron filter) 6. Sample water pump 7. Detection module 8. Data acquisition electronics module 9. System control module 10. Waste water output line, RV output line and sample bypass output lines COOLING SYSTEM In order to have maximum efficiency of the liquid scintillator, solution that is tested inside of the sample cell is kept between 12 C and 20 C. This is achieved by internal cooling loop system, which is a closed loop cooling system with its own pump and chiller unit. If the unit operates in extreme temperatures (more than 45 C) external cooling loop is provided, where user shall provide chilled water from its own source. HWLD:PAGE 2

PLC CONTROL Sampling of input lines and control of alarms and pumps is done by PLC unit placed inside of the System Control Module. There is an alarm provided in case of PLC failure as well as manual override so that the operation can be continued manually until PLC is replaced. Manual operation is a backup system; the unit normally operates in automatic mode. ROUTINE MAINTENANCE Scheduled maintenance of consumables is required. Liquid scintillator needs to be replenished every 2 months and sample water filters need to be replaced. Also, periodic check of the efficiency and background is recommended if there is a possibility of increased background contamination and due to standard lifecycle of electronics components. ANNUAL INSPECTION AND SERVICE It is recommended that the instrument be inspected and serviced on an annual basis to ensure continuing trouble free operation. All components of the instrument should be inspected and instrument re-calibrated. REPAIR Equipment failures of a minor nature can be repaired under local supervision by the operator of the equipment. When necessary, the manufacturer (Overhoff Technology Corporation (OTC)) can dispatch service personnel for quick remediate action. DOCUMENTATION All OTC equipment is accompanied by complete documentation, which includes the following: 1. User and Maintenance Manual that contains: a. Theory of operation b. Installation instructions c. Operation instructions d. Calibration procedure e. Suggested maintenance f. Repair instructions g. Drawings, diagrams and schematics Training will be provided by the manufacturer, free of charge. Assistance with commissioning is also available by the manufacturer (OTC). HWLD:PAGE 3

MODEL 1925 TECHNICAL SPECIFICATION MEASUREMENT RANGE: RESOLUTION (SENSITIVITY): 3.7kBq/L 130kBq/L 1.0kBq/L MINIMUM DETECTABLE LIMIT: 3.7kBq/L at confidence level of 95% DISPLAY: RESPONSE RATE: MEASUREMENT METHOD: DETECTOR: SIGNAL PROCESSING: MEASUREMENT ALARM SET POINT: DATA RECORDING: SAMPLING/MIXING SYSTEM: SAMPLE CELL: WASTE MANAGEMENT: 6 Digit Vacuum Fluorescent Display 3 min beginning of the response, 9 min full value displayed Liquid Scintillation Counting Dual PMT coincidence counter surrounded by multi-element shielding Electronic signal processing of coincident pulses for tritium specific wave shapes (height and duration) Can be manually adjusted Serial Data Recorded with Microdrive card Dual head, low flow rate pump. Liquid scintillator and sample mixed at the sample cell. Stainless steel cell, volume 5cc with fused silica windows and Viton O-rings for sealing. Waste water output lines with Swagelok fittings are provided, user to provide waste collection system. TEMPERATURE: 0 C to 50 C HUMIDITY: 0 to 95 % R. H. SEISMIC: ELECTRICAL: MECHANICAL: DIMENSIONS: Withstands modest shock Power 110/230VAC, 5A Self contained, mounted on a steel frame with lifting eyes for easy transport. 31.5in x 23.6in x 84.0in (800mm x 600mm x 2133mm) WEIGHT: 1100 lb (500 kg) HWLD:PAGE 4

PARTS LIST PARTS LIST FOR MODEL 1925 HEAVY WATER LEAK DETECTOR Qty Req d 2 kits 10 each 10 each Part No. 614C359C2 608F6370C2 609F6075C2 614D6360C2 686B6295C2 565C6289C2 564F6852C2 564E6851C2 544E6165C2 545A6259C2 601B533C2 601c6534C2 584A6217C2 601D6535C2 611C7017C2 584C6373C2 653D6010C2 817D7186C2 160F6019C2 Description Photo Multiplier Tube Ass y Pre-Amplifier PCB Ass y Comparator PCB Ass y Display PCB Ass y Alarm/Relay PCB Ass y Pump Kit Viton O-ring Viton O-ring Relief Valve 3 way Solenoid Valve Level Switch Level Switch Filter Cartridge Dual Pressure Switch Rtd, 3 Wire Class Filter Element Armature Brush Eprom Spray Can with Touch up paint HWLD:PAGE 5 WEB www.overhoff.com