Pace Analytical e-report



Similar documents
APPENDIX C. DATA VALIDATION REPORT

Appendix C Data Validation Report

APPENDIX II TIER I CHECKLIST

Third Party Data Validation: What you need to know and do!

ANALYTICAL SUMMARY REPORT

Certifications: New York (EPA: NY00906, ELAP: 11078), New Jersey (NY026), Connecticut (PH-0337), Massachusetts (M-NY906), Virginia (1884)

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

Introduction. The following definitions may help you better understand the components of the data report.

Analytical Data Package Reports

APPENDIX L DATA VALIDATION REPORT

CERTIFICATE OF ANALYSIS

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

CLIENT NAME: MISC AGAT CLIENT ON, ON (403) ATTENTION TO: Chantell Cambal

Laboratory Data Management. August 2011

This report contains the analytical results for the samples received under chain of custody by TestAmerica on October 29, 2010.

Ecology Quality Assurance Glossary

1 Quality Assurance and Quality Control Project Plan

METHOD 8082A. POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

Approvals [Signature On File]

Quality Assurance Manual

Drip Club 2540 Corporate Place, Suite B103 Monterey Park, CA 91754

DATA QUALITY OBJECTIVES

DATA VALIDATION STANDARD OPERATING PROCEDURES FOR CONTRACT LABORATORY PROGRAM ROUTINE ANALYTICAL SERVICES

New Jersey Department of Environmental Protection Division of Remediation Management Response Site Remediation Program

STANDARD OPERATING PROCEDURES

DATA QUALITY ASSESSMENT AND DATA USABILITY EVALUATION TECHNICAL GUIDANCE

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Sample Management SOP 2v8 Page 1 STANDARD OPERATING PROCEDURE NO. 2 SAMPLE MANAGEMENT REVISION LOG. Revision Number Description Date

Technical Guidance Manual for the Implementation of the Hawai`i State Contingency Plan. Interim Final SECTION 10

How To Test For Contamination In Large Volume Water

Medical Cannabis Laboratory Approval Program

QUALITY ASSURANCE PLAN

APPENDIX L META ENVIRONMENTAL FORENSIC REPORTS

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

Quality Assurance Plan

Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program

ASSURING THE QUALITY OF TEST RESULTS

QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE

Bryte Chemical Laboratory Quality Assurance Manual

Vieques Island Biota Sampling Project. Data Validation Report; October 14, 2005 Revision 1 January 26, 2006 Page 1

CHAPTER ONE TABLE OF CONTENTS 1.0 INTRODUCTION... 1

Minnesota Pollution Control Agency. Quality Assurance Project Plan Guidance

METHOD POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Laboratory Information Management System (LIMS) in EMRL

Version 1.0 September, Jean W. Munch and Paul E. Grimmett

MIDLAND AREA SOIL SAMPLING MIDLAND, MICHIGAN

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

QA/QC. Standard methods in field. QA/QC in the field. QA/QC in analysis

Quality Assurance Plan

Proficiency Testing In A Global Analytical Environment Benefits & Challenges. AOAC September 2007

QUALITY ASSURANCE PROJECT PLAN FOR BROWNFIELDS/VOLUNTARY CLEANUP PROGRAM SITES

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Electronic Data Validation Using the Locus Environmental Information Management System. Tricia Walters Locus Technologies

State Water Resources Control Board Environmental Laboratory Accreditation Program

ATTACHMENT 2. BMP Monitoring Plan Template

APPENDIX F Data Validation Program Memorandum

Life & Times of a PM2.5 Filter: Quality Control in the Laboratory and Beyond

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Determination of Total Suspended Solids (TSS) and Total Volatile Solids (TVS) in Waters of Fresh/Estuarine/Coastal Waters

APPENDIX 7-B SUGGESTED OUTLINE OF A QUALITY ASSURANCE PROJECT PLAN

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

GUIDELINES FOR USE BY CLASS A LICENSEES IN MEETING SNP REQUIREMENTS JULY 1996

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

A Guide to Analytical Laboratory Services

HORIZONTAL concerning the layout, editorial and technical content, this document needs revising. In order to harmonize all documents within

APPENDIX N. Data Validation Using Data Descriptors

DMA-1 Direct Mercury Analyzer

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Standard Operating Procedure for Document Storage, Archival, and Retrieval

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

CEDEN. California Environmental Data Exchange Network

DRAFT Changes to 25 Pa. Code Chapter 252 For Discussion Purposes Only January 21, 2015 CHAPTER 252. ENVIRONMENTAL LABORATORY ACCREDITATION

This example of a completed sampling plan worksheet has been included to illustrate the information

Laboratory Quality Assurance Manual

MILESTONE H E L P I N G C H E M I S T S

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

4 QUALITY ASSURANCE 4.1 INTRODUCTION

How To Get Blood Test Records From A Blood Alcohol Test

Quality Assurance For Environmental Laboratories

Transcription:

Date Issued: July 28, 2014 Pace Analytical e-report Report prepared for: ATLANTIC TESTING LABORATORIES, LTD 22 CORPORATE DR CLIFTON PARK, NY 12065 CONTACT: Derek Converse ---------------------------------------------- Project ID: CT6607 SLC BOE BLDG COURT ST. ENTRANCE Sampling Date(s): July 17, 2014 Lab Report ID: 14070650 Client Service Contact: Kelly Miller (518) 346-4592 ext. 3844 ---------------------------------------------- Analysis Included: PCB Analysis Test results meet all National Environmental Laboratory Accreditation Conference (NELAC) requirements unless noted in the case narrative. The results contained within this document relate only to the samples included in this report. Pace Analytical is responsible only for the certified testing and is not directly responsible for the integrity of the sample before laboratory receipt. This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. Dan Pfalzer Laboratory Director Certifications: New York (EPA: NY00906, ELAP: 11078), New Jersey (NY026), Connecticut (PH-0337), Massachusetts (M-NY906), Virginia (1884) Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone: 518.346.4592 internet: www.pacelabs.com Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 1 of 17

This page intentionally left blank. Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 2 of 17

Table of Contents Section 1: CASE NARRATIVE... 4 Section 2: QUALIFIERS... 6 Section 3: SAMPLE CHAIN OF CUSTODY... 8 Section 4: SAMPLE RECEIPT...11 Section 5: GC - PCB...13 Section 6: Quality Control Samples (Lab)...15 1 2 3 4 5 6 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 3 of 17

1 CASE NARRATIVE Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 4 of 17

July 28, 2014 CASE NARRATIVE This data package (SDG ID: 14070650) consists of 1 caulk sample received on 07/19/2014. The sample is from Project Name: CT6607 SLC BOE BLDG COURT ST. ENTRANCE. This sample delivery group consists of the following samples: Lab Sample ID Client ID Collection Date AR23105 CT6607PI01-071711 07/17/2014 11:55 1 Sample Delivery and Receipt Conditions (1.) All samples were delivered to the laboratory via FEDEX delivery service on 07/19/2014. (2.) All samples were received at the laboratory intact and within holding times. (3.) All samples were received at the laboratory properly preserved, if applicable. PCB Aroclor Analysis Analysis for PCB Aroclors was performed by method SW-846 8082A. Samples were extracted by Soxhlet Extraction Method (EPA - Method 3540C). The following technical and administrative items were noted for the analysis: (1.) The concentration results for Aroclor 1254 were flagged (AF) to denote that an altered Aroclor pattern was observed. Please see form for details. Respectfully submitted, Kelly A. Miller Project Manager S:\Lims Data\1407\14070650\Package\CN_14070650_Rev00.doc Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 5 of 17

2 QUALIFIERS Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 6 of 17

Qualifier Definitions Organic Laboratory Qualifiers B - Denotes analyte observed in associated method blank or extraction blank. Analyte concentration should be considered as estimated. D - Surrogate recovery not evaluated against control limits due to sample dilution. E - Denotes analyte concentration exceeded calibration range of instrument. Sample could not be reanalyzed at secondary dilution due to insufficient sample amount, quick turn-around request, sample matrix interference or hold time excursion. Concentration result should be considered as estimated. 2 J - Denotes an estimated concentration. The concentration result is greater than or equal to the Method Detection Limit (MDL) but less than the Practical Quantitation Limit (PQL). P - Indicates relative percent difference (RPD) between primary and secondary gas chromatograph (GC) column analysis exceeds 40 % or indicates percent difference (PD) between primary and secondary gas chromatograph (GC) column analysis exceeds 25 %. U - Denotes analyte not detected at concentration greater than the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilution factors. Z - Chromatographic interference due to polychlorinated biphenyl (PCB) co-elution. * - Value not within control limits. Inorganic Laboratory Qualifiers B - Denotes analyte observed in associated method blank or digestion blank. Analyte concentration should be considered as estimated. E - Denotes analyte concentration exceeded calibration range of instrument. Sample could not be reanalyzed at secondary dilution due to insufficient sample amount, quick turn-around request, sample matrix interference or hold time excursion. Concentration result should be considered as estimated. J - Denotes an estimated concentration. The concentration result is greater than or equal to the Method Detection Limit (MDL) but less than the Practical Quantitation Limit (PQL). U - Denotes analyte not detected at concentration greater than the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilution factors. * - Value not within control limits. QA_QUALIFIERS_LIST_090413_REV01_01 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 7 of 17

SAMPLE CHAIN OF CUSTODY 3 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 8 of 17

Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 9 of 17 3

Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 10 of 17 3

SAMPLE RECEIPT 4 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 11 of 17

SAMPLE RECEIPT REPORT 14070650 Pace Analytical Services, Inc. 2190 Technology D rive S chenectady, N Y 12308 P hone: 518.346.4592 Fax: 518.381.6055 CLIENT: ATLANTIC TESTING LABORATORIES, LTD PROJECT: CT6607 SLC BOE BLDG COURT ST. ENTRANCE LRF: 14070650 REPORT: ANALYTICAL REPORT EDD: YES LRF TAT: 1 WEEK RECEIVED DATE: 7/19/2014 09:45 SAMPLE SEALS INTACT: NA SHIPPED VIA: FEDEX 1,2 SAMPLES PRESERVED PER METHOD GUIDANCE: YES SHIPPING ID: 770639782582 3 SAMPLES REC'D IN HOLDTIME: YES NUMBER OF COOLERS: 1 DISPOSAL: BY LAB (45 DAYS) CUSTODY SEAL INTACT: YES COC DISCREPANCY: NO COOLER STATUS: CHILLED 5 TEMPERATURE(S): 5.0 C COMMENTS: CLIENT ID (LAB ID) TAT-DUE Date 4 DATE-TIME SAMPLED MATRIX METHOD TEST DESCRIPTION CT6607PI01-071711 (AR23105) 1 WEEK 07-28-14 7/17/2014 11:55 Caulk EPA 8082A PCB Analysis QC REQUEST 1The ph preservation check of Oil and Grease (Method 1664) is performed as soon as possible after sample receipt and may not be included in this report. 2 The ph preservation check of aqueous volatile samples is not performed until after the analysis of the sample to maintain zero headspace and is not included in this report. 3 Samples received for ph analysis are not marked as a hold time exceedance here. SW-846 methods suggests analysis to be done within 15 minutes of sample collection. Because of transportation time it is not possible for the laboratory to perform the test in that time. Sample Certificates of Analysis reports are noted as such. 4 Samples arriving at the laboratory after 4:00 pm are assigned a due date as if they arrived the following business day unless other arrangements have been made. 5All samples which require thermal preservation shall be considered acceptable when received greater than 6 degrees Celsius if they are collected on the same day as received and there is evidence that the chilling process has begun, such as arrival on ice.control limits are between 0-6 Degrees Celsius. Control limits do not apply for metals analysis. Reporting Parameters and Lists 4 EPA 8082A - PCB Analysis - (ug/g) Aroclor 1016 Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Aroclor 1268 Total PCB Amount > RL This report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc. Page 1 of 1 2190 Technology Drive Schenectady, NY 12308 Phone 518.346.4592 Fax 518.381.6055 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 12 of 17

GC - PCB 5 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 13 of 17

Analytical Sample Results Job Number: 14070650 Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone: 518.346.4592 Fax: 518.381.6055 Client: ATLANTIC TESTING LABORATORIES, LTD Project:CT6607 SLC BOE BLDG COURT ST. ENTRANCE Client Sample ID: CT6607PI01-071711 Lab Sample ID: 14070650-01 (AR23105) Collection Date: 07/17/2014 11:55 Sample Matrix: CAULK Received Date: 07/19/2014 09:45 Percent Solid: N/A Batch ID Method Date Analyst Init Wt./Vol. Final Vol. Column Analysis 1: GC10F-1141-8 SW-846 8082A (PCB) 07/25/2014 17:12 JKA NA NA Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm Prep 1: 27642 EPA 3540C 07/24/2014 16:20 MBG 1.52 g 25.0 ml NA Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File ID Aroclor 1016 12674-11-2 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1221 11104-28-2 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1232 11141-16-5 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1242 53469-21-9 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1248 12672-29-6 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1254 11097-69-1 3.27 0.328 1.00 AF GC10F-1141-8 Aroclor 1260 11096-82-5 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1262 37324-23-5 ND 0.328 1.00 U GC10F-1141-8 Aroclor 1268 11100-14-4 ND 0.328 1.00 U GC10F-1141-8 Total PCB Amount > RL 1336-36-3 3.27 1.00 GC10F-1141-8 5 Limits 1 Surrogate CAS No. % Recovery (%) Q File ID Tetrachloro-meta-xylene 877-09-8 92.6 60.0-140 GC10F-1141-8 Decachlorobiphenyl 2051-24-3 95.0 60.0-140 GC10F-1141-8 1Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. ND: Denotes analyte not detected at a concentration greater than the PQL. PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample. AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern. This report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone 518.346.4592 Fax 518.381.6055 www.pacelabs.com Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 14 of 17

Quality Control Samples (Lab) 6 Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 15 of 17

Quality Control Results Method Blank Job Number: 14070650 Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone: 518.346.4592 Fax: 518.381.6055 Client: ATLANTIC TESTING LABORATORIES, LTD Project:CT6607 SLC BOE BLDG COURT ST. ENTRANCE Client Sample ID: Method Blank (AR23105B) Lab Sample ID: PBLK-67 Collection Date: N/A Sample Matrix: CAULK Received Date: N/A Percent Solid: N/A Batch ID Method Date Analyst Init Wt./Vol. Final Vol. Column Analysis 1: GC10F-1141-6 SW-846 8082A (PCB) 07/25/2014 16:47 JKA NA NA Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm Prep 1: 27642 EPA 3540C 07/24/2014 16:04 MBG 10.1 g 25.0 ml NA Analyte CAS No. Result (ug/g) PQL Dilution Factor Flags File ID Aroclor 1016 12674-11-2 Aroclor 1221 11104-28-2 Aroclor 1232 11141-16-5 Aroclor 1242 53469-21-9 Aroclor 1248 12672-29-6 Aroclor 1254 11097-69-1 Aroclor 1260 11096-82-5 Aroclor 1262 37324-23-5 Aroclor 1268 11100-14-4 Total PCB Amount > RL 1336-36-3 ND 1.00 U GC10F-1141-6 6 Limits 1 Surrogate CAS No. % Recovery (%) Q File ID Tetrachloro-meta-xylene 877-09-8 91.2 60.0-140 GC10F-1141-6 Decachlorobiphenyl 2051-24-3 102 60.0-140 GC10F-1141-6 1Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. ND: Denotes analyte not detected at a concentration greater than the PQL. PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample. This report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone 518.346.4592 Fax 518.381.6055 www.pacelabs.com Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 16 of 17

Quality Control Results Lab Control Sample (LCS) Job Number: 14070650 Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone: 518.346.4592 Fax: 518.381.6055 Client: ATLANTIC TESTING LABORATORIES, LTD Project:CT6607 SLC BOE BLDG COURT ST. ENTRANCE Client Sample ID: Lab Control Sample (AR23105L) Lab Sample ID: LCS-67 Collection Date: N/A Sample Matrix: CAULK Received Date: N/A Percent Solid: N/A Batch ID Method Date Analyst Init Wt./Vol. Final Vol. Column Analysis 1: GC10F-1141-7 SW-846 8082A (PCB) 07/25/2014 16:59 JKA NA NA Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm Prep 1: 27642 EPA 3540C 07/24/2014 16:05 MBG 10.2 g 25.0 ml NA Analyte Spiked CAS No. Added LCS LCS Limits 1 (ug/g) (ug/g) % Rec. Q (%) Aroclor 1254 11097-69-1 1.22 1.14 93.0 70.0-130 1Qualifier column where '*' denotes value outside the control limits. Note: RPD criteria does not apply if either the sample and duplicate sample are not detected. Limits 1 Surrogate CAS No. % Recovery (%) Q File ID Tetrachloro-meta-xylene 877-09-8 90.8 60.0-140 GC10F-1141-7 Decachlorobiphenyl 2051-24-3 101 60.0-140 GC10F-1141-7 1Qualifier column where '*' denotes value outside the control limits or 'D' denotes value was diluted out. ND: Denotes analyte not detected at a concentration greater than the PQL. PQL (Practical Quantitation Limit). Denotes lowest analyte concentration reportable for the sample. 6 This report may not be reproduced except in full, without the written approval of Pace Analytical Services, Inc. 2190 Technology Drive Schenectady, NY 12308 Phone 518.346.4592 Fax 518.381.6055 www.pacelabs.com Pace Analytical Services, Inc. July 28, 2014 14070650 - Page 17 of 17