How Lightning Safety Practices Differ in Wind Energy, Sports and Construction Applications



Similar documents
LIGHTNING SAFETY: OUTDOOR COMMUNITY PREPARDNESS FACILITY: POINT OF CONTACT:

ATHLETIC TRAINERS OPERATING POLICIES AND PROCEDURES PENNSYLVANIA STATE ATHLETIC CONFERENCE

Alabama A&M University Sports Medicine. Athletic Injury and Medical Policy

Athletics Department Emergency Action Plan

Emergency Action Plans. Department of Athletics

SPORTS MEDICINE POLICIES AND PROCEDURES

GE Wind Turbine Climbing Rules and Rescue from Height

Safe Work Procedure. Purpose To ensure all employees are educated and prepared in the event of a lightning storm.

Keller ISD Weather Emergency Procedures Extracurricular Activities

EMERGENCY RESPONSE PLAN. This Emergency Response Plan describes the functions and procedures of USA Track & Field,

A Detailed Analysis of Lightning Deaths in the United States from 2006 through 2013

Beloit College Athletic Training Mission Statement. Hours of Operation. Athletic Training Department rules

Emergency Action Plan

Gurnee Park District T-ball/Lil Sluggers Parent Manual

8. MEDICAL EMERGENCY ACTION PLAN

SUSPENSION OF AN INTERCOLLEGIATE FOOTBALL GAME DUE TO LIGHTNING

Game 6 Innings 6 Innings 6 Innings 6 Innings 6 Innings 7 Innings 7 Innings. No No No Yes Yes Yes Yes. No Restrictions

Specific heat conditions will determine activity restrictions during practice according to the following:

Oregon Youth Soccer Association Weather Related Safety Precautions

Emergency Management is responsible for coordinating the City of Houston s preparation for and response to emergency situations.

EMERGENCY PROCEDURES Revised July Do Not Remove

SUNY Cobleskill Sport and Exercise Department Emergency Action Plan

Virginia Beach Little League Local Rules (By Laws) Fall, 2015

Lightning is the most dangerous and frequently

Vaisala s NLDN U.S. National Lightning Detection Network / ADVANCED TOTAL LIGHTNING TM. SCIENTIFIC ACCURACY. PROVEN RELIABILITY.

Evaluation of the "StrikeGuard" Lightning Alarm Sensor Using Lightning Location System (LLS) Lightning Data

Needham Baseball Managers and Coaches Code of Conduct

Wind Turbine Risk. Dr Phillip Bratby

SEAWORLD ORLANDO LIGHTNING INCIDENT FAILURE OF THE SECOND GENERATION EARLY STREAMER EMISSION LIGHTNING ROD

LAGC Construction Site Hurricane Preparedness Plan

Construction Industry Safety History CSTM 102

Factors to Consider When Developing an Evacuation Plan

Drug Testing and Student-Athletes in Nebraska

Level 1 Award in Health and Safety in a Construction Environment

Implementation Date: May 5, Table of Contents. Section Description Page. 1.0 Description Initial Response 2

Adapting to Climate Change Through Asset Management Planning. Tiffany Batac David Rose, PhD Parsons Brinckerhoff

Girl Scouts Louisiana East Emergency Preparedness Patch program for Girl Scout Brownies Seniors

ILLINOIS SEVERE WEATHER FACTS

ADVENTURE ISLAND LIGHTNING INCIDENT. REPORT ON THE DEADLY FAILURE OF AN EARLY STREAMER EMISSION LIGHTNING ROD [Revision 1)

MODEL ORDINANCE FOR WIND ENERGY FACILITIES IN PENNSYLVANIA. This Ordinance shall be known as the Wind Energy Facility Ordinance for [municipality].

Fall Protection Plan for Residential Roofing Construction. Tim Graboski Roofing, Inc.

State Of Wisconsin Department of Military Affairs

Guidance to CBs, Clubs and Schools on Serious Injury Management

TROY UNIVERSITY ATHLETIC TRAINING DEPARTMENT EMERGENCY PHONE NUMBERS

Stanford University Presents The Stanford Track & Field Invitational April 1-2, 2016 Cobb Track and Angell Field COLLEGE/OPEN ENTRY INFORMATION

Work at Height / Falling Objects

Student-Athletes. Guide to. College Recruitment

Pennsylvania Flood Safety Awareness Week March 6-10th, 2015

Providing drivers with actionable intelligence can minimize accidents, reduce driver claims and increase your bottom line. Equip motorists with the

A Publication of Encharter Insurance. The Insurance Guide To: DISASTERS A GUIDE TO CONVERTING PROSPECTS INOT USTOMERS

Thunderstorm Basics. Updraft Characteristics (Rising Air) Downdraft Characteristics (Air Descends to the Ground)

Student Athletic Trainer Policy and Procedure Handbook. Southwestern Oklahoma State University

Overhead Power Line Safety for Contractors

University of Washington Athletics Department Internship Program

Central Office Emergency Preparedness Plan

UNIVERSITY OF WASHINGTON ATHLETIC TRAINING INTERNSHIP PACKET

Emergency Communication: Fixed telephone line in GA office , office , and office phone

Garrett Middle School Athletic Handbook

PIAA News Updates PIAA Sports Medicine Advisory Committee. Topics Recently Addressed. New High School PIAA Guidelines Michael Cordas, Jr., D.O.

THE UNIVERSITY OF SHEFFIELD WORK AT HEIGHT POLICY

FIELD AND FACILITY PERMIT APPLICATION NAME: ADDRESS: PHONE: (H) (W) (C) SPORT. Name of Organization, Team, Club Etc.

University of St. Thomas Club Sports Program

NCAA Convention Indianapolis, Indiana January 6, 2006 Creating a Safe and Secure Competitive Venue

SITE SPECIFIC FALL PROTECTION PLAN

Church safety solutions April 2008

Lab 10. Solar and Wind Power

Response and Recovery

EMERGENCY PREPAREDNESS

RISD Hurricane Preparedness

How To Prevent Accidents At Work

Utah High School Girls Golf State Championships:

Brevard College Policies and Procedures Manual Policies and Procedures Manual

Backcountry Avalanche Rescue Reference

EMERGENCY COMMUNICATION PLAN

Sports Specific Safety. Golf. Sports Medicine & Athletic Related Trauma SMART Institute 2010 USF

Play it Safe in the Heat Tips for Coaches and Parents

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

Brewton-Parker College Sports Medicine Student Athlete - Medical Policies & Procedures

High Voltage. Hazards

REGATTA SAFETY ADVISER

Floods are too much water on normally dry land. Rivers can flood after heavy rain has fallen over a long period of time. River flooding can last

EVENT RISK ASSESSMENT EXAMPLE / 04

SOCCER NOVA SCOTIA REFEREE DEVELOPMENT COMMITTEE REFEREE HANDBOOK

The Application of Rope Access Methods in the Construction, Inspection, Repair and Maintenance of Wind Turbines

NCAA CATASTROPHIC INJURY INSURANCE PROGRAM FREQUENTLY ASKED QUESTIONS

News, Media and Press Conferences

Strategic Planning Administration Budget Development Compliance Personnel Management Facilities & Capital Improvements Revenue Optimization

SPONSORSHIP PROPOSAL

High-voltage systems. Identifying high-voltage overhead conductors

FMCSA Webinar Nov.18th to Examine Large Truck Crash Fatalities Involving Pedestrians & Bicyclists. New Technology for Better Fleet Management

COACH PITCH RULES (7-8 Year Olds) COACHES SHOULD MEET TO DISCUSS GROUND RULES PRIOR TO EVERY GAME

PLANNING TOOL FOR FUTURE LEAGUE NEEDS

SECTION VI SPORT ADMINISTRATION

EARTHQUAKE SAFETY IN THE WORK PLACE

Chippewa County Courthouse Security Emergency Procedures. Dial FIRE POLICE AMBULANCE

Using Renewable Energy to Pump Water

(3) CATEGORY III means a permanent heliport facility. (4) COMMISSION means the City of Austin Airport Advisory Commission.

APRIL 1989 LAW REVIEW WRESTLING CLASS SPARKS BATTLE OF THE EXPERT WITNESSES

THOMPSON SCHOOL DISTRICT CHECKLIST FOR ATHLETIC PARTICIPATION. Part A - PARENT PERMIT FOR ATHLETIC PARTICIPATION AND INSURANCE COVERAGE

Role of the Athletic Trainers:

Transcription:

How Lightning Safety Practices Differ in Wind Energy, Sports and Construction Applications Don Leick, Director of Product Management, Telvent DTN Introduction Lightning safety concerns and practices can differ considerably in different applications. The response to the same thunderstorm by a wind farm, a construction company, and a baseball team can be quite different. This paper will compare and contrast real-world concerns and practices of wind farms, collegiate athletics, and the construction industry. This includes differing lightning notification times, considerations for resuming activity, and risk profiles. It will also include discussion of special factors such as the pressure to resume activity when fans are present. Some possible reasons for differences are provided, along with some recommendations to improve the adoption of safety practices and tools in commercial applications, and reduce the risk of death or severe injury from lightning. Telvent DTN has years of experience providing lightning safety tools to most of the leading wind farm operators and turbine manufacturers in the US, several hundred American colleges and universities, and is the leading provider of specialized weather services for construction in the US. This experience will provide the basis for discussing actual issues and practices in these safety applications. Lightning Notification Procedure This paper assumes the availability of best-practice tools: an effective national lightning detection network and the ability to communicate that lightning danger directly to the affected people. This communication can occur via a text message, which can also trigger an audible alarm on the phone. This paper further assumes a best practice procedure as follows: 1. An Advisory notification when lightning is in the area but not close enough to require evacuation. This enables the affected parties to begin necessary preparations, be aware of the need to diligently watch for a warning, or avoid starting activities that may increase risk. 2. A Warning notification when suspension of activities must occur and a safe location must be sought. 3. An All-clear notification when there has been no lightning within the area for a prescribed period of time.

The distance that one sets for the advisory and warning notifications varies based primarily on how long it takes to evacuate, that is, how long it takes to suspend activities and reach safety. Overview of the Different Applications Three different common lightning applications have been selected to illustrate how different lightning safety practices can be-- even when using the same lightning safety tools. Following is a brief description of each to help understand the risk with each application. Then the applications will be compared and contrasted. The three applications discussed are: 1. Wind farms: This primarily involves maintenance workers up in the turbine. The height of the wind turbine increases lightning strike risk. The long time it takes to get down from the tower also increases risk, and increases the needed evacuation time. 2. Construction: Of special concern are cranes and cement boom trucks, but the risk applies to any construction worker, especially those at heights, such as roofers. 3. Collegiate athletics: This involves any outdoor sports, both for the safety of participants and fans: baseball, track & field, football, and so on. Each of these safety applications will be discussed further, as follows. Wind farm safety Wind farms are booming worldwide. With that is a booming need to keep maintenance workers safe. Wind turbines are notoriously high-maintenance, and on any given day a maintenance crew will typically be up in the turbine (the nacelle or turbine housing) at the top, or hub, of a tower. The turbine is typically 80 meters (over 250 feet) above ground. This poses a special lightning risk in two ways: 1) The towers are also essentially large lighting rods. There is even some suspicion that turbines are even more prone to lightning strikes than other structures of similar height. 2) The evacuation time the towers represents is also significant. The turbine is reached by steep winding stairs inside the tower. When a worker needs to evacuate, typically it can take up to 20 minutes to get down, with equipment & safety harnesses involved, and into the safety of their truck. Further some operations want employees out of the wind farm entirely due to possible danger of turbine blades exploding when struck by lightning. So the lead time required here is significant. There is also the factor that it is inefficient and tiring to start and stop and work when you have to climb such a tower. So turbine

maintenance workers really want to avoid having to suspend work but at the same time are acutely sensitive to the lightning danger and will suspend work immediately if needed. Here are typical wind farm lightning alert procedures 1 : Notification range: 50 miles. Workers will go up in the turbines (will not start work) when lightning is within 50 miles of the wind farm. Warning (evacuation) range: 30 miles. Stop work in turbines and come down. All clear range and time: 50 miles and 15 minutes. Work in turbines can resume when there has been no lightning within this time distance for 15 minutes. The lightning safety risk at wind farms is widely known. The use of lightning safety measures is widespread. We believe most US wind farm maintenance organizations have lightning safety tools and similar practices as described here. Construction safety Especially as we look ahead to spring and summer, lightning can be a serious risk for exposed construction crews. Work is often occurring in open areas, such road construction and excavation. Roofing and high rise construction crews are also at increased risk due to heights. Operators of tall equipment, such as cranes and cement pumps, are at additional risk. This equipment often has an open cab leaving the operator exposed and vulnerable to lightning. The National Lightning Safety Institute recommends that construction workers be aware of the threat when lightning is 20-40 miles from the site, and suspend activities and evacuate when lightning is within 10 miles 2. However, from our experience there are relatively few risk management guidelines. Most construction companies do not have standard lightning safety policies. However, typically the larger the organization, the greater the awareness and the greater the likelihood that the organization has standard safety practices and tools. Collegiate Athletics Clearly outdoor athletics pose a greater risk for lightning. You have open athletic venues with light poles, flagpoles, metal fences and little or no shelter. Baseball dugouts don t provide lightning protection for players as they are not fully enclosed. Open, metal bleachers are contributing factors to the lightning risk for fans. For lightning evacuation, the NCAA uses a standard warning of an 8 mile radius for all Outdoor Spring/Fall Regional and Championship events (such as baseball or track & field tournaments). Since the time it takes to get to safety into a bus, car, or inside a

stadium - the 8 mile radius is generally a good distance. Golf events or large spectator crowds may require a longer evacuation time which would mandate a larger warning radius. A 30-minute all-clear time is the standard operating procedure (play can resume when there has been no lightning within 8 miles for 30 minutes). The adoption of lightning safety procedures and best practices in collegiate athletics is a priority and top concern for administration. Compare and Contrast Here is a compare and contrast view of the risk and practices in the different applications: Application Lightning risk Safety Tool Adoption Advisory range Warning (evacuation) range All clear range & time Wind farms Very high Very high 50-60 miles 30 miles 50 miles, 15 minutes Construction High Low Varies Varies Varies Collegiate Athletics High Moderate to High Varies. 15 miles is common 8 miles 8 miles, 30 minutes Here are a few observations on the practices. Evacuation time should drive the warning range, and it does. For example, wind farms have a long evacuation time (up to 20 minutes) and thus a long warning range. Another factor is the size of some wind farms, which can be up to 25 miles. Athletics often have a short evacuation time, though not always, and thus have a much shorter warning range. One rule of thumb for warning range is to start with 6 miles and add a mile for each 2 minutes of evacuation time needed (thus never less than 7 miles). This rule of thumb starts with the fact that the National Weather Service recommends you already be to safety when lightning is within 6 miles. And secondly, the average thunderstorm travels at about 25 miles per hour (almost a half mile per minute). When the all clear range is larger the all clear time can be shorter.

Why does one see such a large variation in the adoption of lightning safety tools, if the above is an accurate assessment? Following is some speculation on the reasons for the some of the differences in adoption of best tools and practices. The lightning danger in wind farms is obvious. Even the wind turbines themselves are carefully designed to mitigate damage from lightning. So the personnel risk and the need to reduce that risk seems to be widely understood. Also, often the organizations that have personnel at wind farms are large, sophisticated companies. They recognize the need to watch out for their employees well being and they understand the potential litigation costs if their employees are killed or injured by lightning. While not as great a risk as wind farms, Construction companies still have significant risk, but generally seem to have little concern about lightning safety. Wind farms and construction companies are both commercial entities -- why the great difference? Our speculation is that it is primarily an awareness issue. Construction companies appear to have less awareness of the risk and lower acceptance of the tools available to mitigate risk. Collegiate athletics have historically had good awareness of lightning danger. The NCAA has communicated the risk well 3. The long held and widely known threat of lightning on golf courses may also help. Also, athletic trainers play a key role. Here you have trained professionals on site at the events whose primary job is the health and welfare of the athletes. NATA, the National Athletic Trainer Association, has done a good job of promoting lightning safety practices with athletics trainers 4. What has been sometimes lacking is the corresponding awareness of what to do about the lightning risk. The 30/30 flash bang method, has severe limitations. Frequently you will not be able to hear lightning when it is closer than 8 miles (depending on wind direction and terrain). And one can make mistakes when correlating the thunder to the right flash. So the availability of lightning safety tools and practices can improve safety. One of the benefits of a lighting safety tool is having a non-subjective standard for making suspend/resume decisions. There can be great pressure from coaches, officials or fans to not suspend play. Similarly there can be pressure to resume play prematurely. Having a standard practice and an objective means to make those decisions can be invaluable. This helps take some of the personnel pressure off the trainer, and may be a factor in adoption too. Overall Conclusions and Recommendations Here are some general conclusions that perhaps can be drawn: 1. The awareness of risk is important in whether lightning safety tools are adopted. 2. The awareness of tools is also important. If the risk is known, but its believed little can be done about that risk, you will see low adoption.

3. Having a safety professional involved helps adoption greatly. No tool or practice can provide 100% lightning safety, but here are some recommendations to improve lightning safety in the applications discussed in this paper, and in commercial lightning safety applications in general: For lightning safety organizations: 1. Promote the effectiveness of lightning detection networks and alerting tools. Often merely the flash/bang (count) method is cited to determine how near lightning is and to gage the risk. Safety organization recommendations today are lagging the technology and best practices for lightning safety. 2. Provide standard specific recommendations for advisory ranges, warning ranges and all clear times for different safety applications. Construction companies or universities should not have to determine these themselves. These recommendations should be based on sound scientific research, such as the typical speed of thunderstorms and the unpredictability of the specific location of lightning strokes from a cell. While some applications, such as wind farms and collegiate athletics, have usually developed good approximate guidelines, more standardized guidelines would help speed adoption of lightning safety tools, and help ensure they are being properly used. For end-user organizations: 3. Take advantage of modern lightning safety tools, and have a standard for employees for advisory ranges, warning ranges and all clear times that is appropriate for the application. Make it known in advance that the standard will be adhered to if lightning occurs, so there is no debate later when prompt action needs to be taken. REFERENCES 1 Don Leick, Telvent DTN, Safety Issues that Impact Wind Farms, www.telvent.com/en/business_areas/environment/solutions_overview/energy/wind.cf m 2 National Lightning Safety Institute, Lightning Safety for Outdoor Workers, http://www.lightningsafety.com/nlsi_pls/outdoor_workers.html 3 2008-2009 NCAA Sports Medicine Handbook, Guideline 1d Lightning Safety, pages 13-15

4 National Athletic Trainers Association Position Statement: Lightning Safety for Athletics and Recreation, http://www.nata.org/statements/position/lightning.pdf Journal of Athletic Training 2000;35(4):471 477