Improving SCADA Operations Using Wireless Instrumentation



Similar documents
Environmental Monitoring: Guide to Selecting Wireless Communication Solutions

SCADA Systems. Make the most of your energy. March 2012 / White paper. by Schneider Electric Telemetry & Remote SCADA Solutions

The data can be transmitted through a variety of different communications platforms such as:

Wireless Ethernet LAN (WLAN) General a/802.11b/802.11g FAQ

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Wireless Field Data Backhaul

Defining the Smart Grid WAN

METHODS OF GATHERING EGM DATA Stephen Easley TXU Lone Star Pipeline

Southern Utah Water SCADA Project and Dispelling Myths regarding 900MHz Spread Spectrum Technology:

Considerations for Hybrid Communications Network Technology for Pipeline Monitoring

Product Overview. Steve Erickson

Video Architectures Eyes on the Future: The Benefits of Wireless Technology for Fixed Video Surveillance

The cost and performance benefits of 80 GHz links compared to short-haul GHz licensed frequency band products

Tnet WIRELESS MESH SENSOR NETWORKS

Choosing the Right Industrial Wireless Network

Secure Wireless Infrastructure

Network Communications System. Redefining Intelligent Utility Communications

Can I Cost-Effectively Monitor Critical Remote Locations?

Telemetry & Remote SCADA Solutions. Make the most of your remote assets

Introduction To SCADA and Telemetry

CHOOSING A WIRELESS IMPLEMENTATION STRATEGY AND APPLICATIONS

FIBRE TO THE BTS IMPROVING NETWORK FLEXIBILITY & ENERGY EFFICIENCY

Wi-Fi Why Now? Exploring New Wireless Technologies for Industrial Applications

Wireless solutions for water and wastewater management

MAXIMIZING YOUR DATA CENTER INFRASTRUCTURE: CENTRALIZED MANAGEMENT AND WIRE-FREE ENVIRONMENTAL MONITORING

MOTOROLA S CANOPY WIRELESS BROADBAND PLATFORM

Troubleshooting Slow Internet Common Causes

Wireless Remote Video Monitoring

EKT 331/4 COMMUNICATION NETWORK

Wireless Remote Video Monitoring

Microwave Photonic Systems Inc. Joshua L. Korson & Richard J. Stewart

CHAPTER 1 1 INTRODUCTION

ENVIRONMENTAL MONITORING SYSTEM WITH WORLD-WIDE COVERAGE AND BIDIRECTIONAL COMMUNICATION VIA INMARSAT SATELLITE NETWORK

Wireless Internet. Is an system to provide connectivity to customers to the Internet. Service Provider (WISP) TECHNICAL INFO.

Motorola Wireless Broadband. Point-to-Multipoint (PMP) Access Network Solutions

HUAWEI Enterprise AP Series ac Brochure

Wireless Networking for Small Businesses, Branches and Home Offices

Totally Wireless Video Security

Motorola s Wireless Broadband Point-to-Point Solutions. The PTP 100, 400 & 600 Series Part of Motorola s MOTOwi4 portfolio

Chapter 6 Telecommunications, Networks, and Wireless. Computing

LoRaWAN. What is it? A technical overview of LoRa and LoRaWAN. Technical Marketing Workgroup 1.0

Testing, maintenance and operation of Electronic Flow Computers for the Gas Industry

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications

Iknaia Asset and Personnel Tracking Management System for the Construction Industry

ZyXEL Smart Antenna - The solution to Wi-Fi challenges

White Paper. Wireless Network Considerations for Mobile Collaboration

The Economics of Gigabit 4G Mobile Backhaul

Demystifying Wireless for Real-World Measurement Applications

Maricopa County Regional Wireless Systems An AZTech White Paper on Wireless Systems Being Used in ITS

Are apps available for Virtual Water Assistant? No. We use a mobile website.

Unidirectional Transmitter/ Receiver Units Introduction

PLICSMOBILE: Measurement data via the mobile network

Wireless Feasibility Survey And Site Survey For Sandersville, GA. Jay Sexton and Jeffrey Lee Georgia Tech Research Institute

Portable Wireless Mesh Networks: Competitive Differentiation

AMI and DA Convergence: Benefits of Growing Your Smart Grid Infrastructure with a Multi Technology Approach

Getting the Most Out of Your WirelessHART System

Overcoming IP Address Issues with GPRS Remote Monitoring and Alarm Systems

SCADA Security: Challenges and Solutions

MSRC Best Practices. Communications Infrastructure Security, Access & Restoration Working Group

2.4G Bluetooth Datalink & ipad Ground Station User Guide V1.02

No Wires No Limits With Smart Wireless Technology. V.Suresh Senior Sales Manager Emerson Process Management

INTRODUCTION TO COMMUNICATION SYSTEMS AND TRANSMISSION MEDIA

Deploying In-Building Wireless Solutions

Testing Gateway LTE Performance

App coverage. ericsson White paper Uen Rev B August 2015

Application Note License-Exempt Gigabit Ethernet Microwave Radio Applications

Guide for Performing a Wireless Site Survey. 2.4 GHz IEEE g/802.11b/

Narrowband and Broadband Access Technologies

Early Warning Fire Detection and Integrated Security Solution. System Overview

ZoneFlex Smart n 5GHz Outdoor Wireless Bridge. The First Centrally Managed n 5GHz Outdoor Wireless Bridge BENEFITS

Section 2: Overview of Wireless Broadband Networks

communication over wireless link handling mobile user who changes point of attachment to network

the amount of data will grow. It is projected by the industry that utilities will go from moving and managing 7 terabytes of data to 800 terabytes.

RC:

The evolution of data connectivity

Telecom Applications:

Telemetry, Monitoring & Asset Tracking: M2M Terminal Application Dynamics for Oil & Gas

Why WireFree: Wireless Gas Detection System Basics and Benefits

General Camera Information and use for NuAire Biological Safety Cabinets (BSC) and Isolators

Deploy WiFi Quickly and Easily

WIRELESS INSTRUMENTATION TECHNOLOGY

Wireless Process Control Network Architecture Overview

Accelerated Cellular Extender: Model 6200-FX Accelerated View Remote Management

Bosch IP An introduction to IP technology and the future of CCTV. Bosch IP Network Video Product Guide

LEASED-LINE REPLACEMENT

wireless triple play network -

Understanding Range for RF Devices

SkyWay-Mobile. Broadband Wireless Solution

WI-FI VS. BLUETOOTH TWO OUTSTANDING RADIO TECHNOLOGIES FOR DEDICATED PAYMENT APPLICATION

Rethinking Small Cell Backhaul

Iknaia Asset and Personnel Tracking Management System for the Healthcare Industry

Transcription:

Improving SCADA Operations Using Wireless Instrumentation April 2010 / White paper by Hany Fouda Make the most of your energy

Summary Executive Summary... p 2 Introduction... p 3 The Evolution of Wireless... p 4 Wireless Instrumentation is a Different Game... p 5 Addressing the Wireless and Data Integration Challenges... p 7 Conclusion... p 8

Executive summary The purpose of this paper is to explore the particular ways in which operators can tightly integrate wireless instrumentation networks with SCADA and realize the full benefits of such an integrated solution. White paper on Improving SCADA Operations 02

Introduction Integrating wireless instrumentation with SCADA systems can drive operational efficiency and reduce deployment costs. The use of wireless instruments in pipelines and gas production operations has been gaining momentum over the past few years. Driven by cost cutting measures and the need to gain more operational visibility to meet regulatory requirements, wireless instruments eliminate expensive trenching and cabling while providing access to hard-to-reach areas using self-contained, batterypowered instruments. However, SCADA engineers and operators are facing the challenge of integrating wireless instrumentation networks with other communication infrastructure available in the field. Managing and debugging dispersed wireless networks presents a new level of complexity to field operators that could deter them from adopting wireless instrumentation despite the exceptional savings. This paper will look into the particular ways in which operators can tightly integrate wireless instrumentation networks with SCADA and realize the full benefits of such an integrated solution. White paper on Improving SCADA Operations 03

The Evolution of Wireless Since Guglielmo Marconi sent the first telegraph signal across the Atlantic, wireless became part of our everyday lives. However, the last ten years have seen a dramatic change not only in the radio technology but more importantly in how we use it as consumers and oil and gas professionals. Gas producers and pipeline companies have relied for many years on long range wireless technology to transmit and distribute critical operational data using a wide range of technologies, including satellite, VHF, UHF and license-free spread spectrum. As more consumers lined up to acquire the latest Smart Phones with embedded Wi-Fi, Bluetooth and broadband capabilities, the price of radio modules has plummeted over the past three years. This has made it easy on industrial vendors to integrate radio modules into a long list of devices and sensors. As a result, the O&G industry has seen an increase in wireless instrumentation, also broadly known as wireless sensor networks, offered from major process control and SCADA suppliers. Wireless became the holy grail of the industry with editors and pundits predicting double digit annual growth and a $1.2 billion market by 2012. The business case behind deploying wireless instrumentation is a compelling one. By eliminating cabling and trenching, you can dramatically reduce the cost of deployment by as much as 70%. Since wireless instrumentation is battery powered, they are much easier to deploy in the field relative to their conventional counterparts. Wired systems can take days or weeks to be properly installed. Wireless instruments require only the sensor to be installed in the process, saving hours or days and valuable resources. Other instruments can be added as needed. Safety and compliance with environmental requirements are major driving factors. In gas production, during the initial flowback period, using wireless pressure sensors reduces the risk to personnel who would otherwise need to be in close proximity to a volatile and toxic well in order to read manual pressure gauges and to report on production readiness. During the flowback period before a wired solution can be installed, wireless pressure sensors put the well analyst in touch with the well enabling remote trending and analysis. EPA regulations in many regions require the use of a Vapour Recovery Unit (VRU) to burn off residual gases from separators and condensate tanks. An easy to install wireless temperature sensor can monitor the VRU and report an alarm condition if the flame goes out. White paper on Improving SCADA Operations 04

Wireless Instrumentation is a Different Game So if the business case is that strong and the return on investment is solid, why are some still reluctant to deploy wireless instrumentation in their facilities? There are three main reasons: 1. Reliability In industrial applications, reliability is a major concern. Wireless instrumentation must be as reliable as conventional wired units. Even in simple applications like remote monitoring, users come to expect a certain level of reliability and network availability. Wired systems are much easier to diagnose and trace because the medium, the wire, is physically there or could be dug out. Wireless, on the other hand, uses the invisible free space as a medium. Radio signals are subject to free space attenuation, where the signal loses strength at a rate proportional to the square of the distance travelled. Radio signals are subject to reflection as a result of structure, trees, water bodies and buildings. Furthermore, interference from near-by wireless systems such as cell towers adds more challenges. RF design is getting better in addressing many of these issues. By designing highly sensitive radio receivers, using the transmit power more efficiently and high gain antennas, engineers were able to establish highly reliable RF point-to-multipoint links. 2. Adaptability Wireless instrumentation networks are required to adapt to the existing environment. It is not practical to move a well head, a compressor, tank or a separator just to create a reliable wireless link. In long range SCADA networks, it would be much easier to locate a 30 foot tower in the field to allow for line-of-sight consideration. It might also be easier to increase the height of the tower to extend the range and avoid obstruction. Wireless instrumentation networks do not have that luxury. It is sometimes difficult to find a location for an access point or base radio that provides reliable communication with the wireless instruments. Relocating the access point or base radio to improve the RF link with one sensor could result in degrading the links with other sensors in the same network. Adaptability can be addressed by using lower frequency bands, such as the license-free 900 MHz, which tend to provide better coverage, longer range and better propagation characteristics allowing the signal to penetrate obstacles. Also, high gain external antennas that can be mounted as high as possible on a structure allow access to hard-toreach sensors which could be located at the bottom of a tank. Improved receive sensitivity of radio modules also plays a crucial role in ensuring network adaptability to various industrial environments. White paper on Improving SCADA Operations 05

3. Integration Most gas production, processing plants and pipeline facilities have some level of wireless capability in place. Long range proprietary SCADA networks, backhaul point-to-point networks and local wireless area networks are some of the common systems deployed. Each of these networks is being used for a specific purpose such as control data transmission, high bandwidth communication and video surveillance. Engineers and operators are facing the challenge of integrating wireless instrumentation networks with other communication infrastructure available in the field. Managing and debugging dispersed wireless networks presents a new level of complexity to field operators that could deter them from adopting wireless instrumentation despite the exceptional savings. The wireless networks integration dilemma is more apparent in SCADA systems. Since wireless instrumentation networks are supposed to tie into the same SCADA infrastructure available at site in order to relay valuable operating data to the SCADA host, having the ability to manage the complete infrastructure as one network becomes essential. Moreover, having the ability to access hard-toreach areas and gather new data points that were not economically viable before, gives the operator better visibility into the process and plant operations. However, this data has to end up somewhere in the system in order to be monitored, analyzed and leveraged. SCADA systems are normally designed to handle a certain number of data points or tags. Scaling up the system to handle additional data points and integrate them in trends and reports could be costly. Despite the abundance of tools to capture, process and analyze data in the process control market, ensuring data integration is still a major problem. Some SCADA systems even have a separate historian module that must be purchased as an addon to handle the flood of data as a result of adding wireless instrumentation networks. White paper on Improving SCADA Operations 06

Addressing the Wireless and Data Integration Challenges A new breed of advanced wireless instrumentation base station radios or gateways is now emerging in the marketplace to address this need. This new generation of gateways integrate both a wireless instrumentation base radio and a long range industrial radio in the same device. The wireless instrumentation base radio has a Modbus data port, allowing an external Modbus Master to poll information from the base radio about its own status as well as the status and process values of its field units. It also has a diagnostics port, allowing the connection of the network management software for sensor configuration and diagnostics. Both of these data streams are sent simultaneously through an advanced long range serial or Ethernet radio network. This is how it works in practice: The wireless instrumentation base radio and all field units must have the RF Channel and Baud Rate set identically. The integrated long range remote radio is configured as a remote device relaying information to a Master radio at the main SCADA center. The available two serial ports on the radio are configured to tunnel Modbus polling and diagnostic data simultaneously to the wireless instrumentation base radio. This allows operators to manage and diagnose the wireless instrumentation network through the existing long range SCADA infrastructure. Live data and status information for all field units are displayed in a separate view or integrated in the SCADA host. On the data integration front, modern SCADA host software offers a fully integrated environment that includes an integrated and scalable historian to handle more additional data without going through expensive and sometimes lengthy upgrades. Developing the SCADA screens based on templates allow engineers to add data points easily and rapidly in their systems. Each field unit must then have its RF ID set to a unique value. This value will be used later for Modbus polling of the data. The base radio s Modbus serial port baud rate must be set to match that of the long range radio. The base radio s Device ID must be set. This value will be required later for Modbus polling of the system. White paper on Improving SCADA Operations 07

Conclusion As the adoption of wireless instrumentation networks increases, users will be faced with a number of challenges to ensure the reliability, adaptability and tight integration with their existing infrastructure. New RF and antenna designs help to address reliability and adaptability challenges. This leaves wireless and data integration with the existing SCADA infrastructure as one of the critical challenges to be resolved. Luckily, hybrid gateways, where sensor network base radio and long range radio are integrated, allow users to view, manage and diagnose their dispersed wireless systems from a single point. Similarly, advanced SCADA host software, with an integrated historian and rapid development environment using templates, can facilitate the integration of new data points generated by a growing network of wireless sensors. White paper on Improving SCADA Operations 08

Schneider Electric Telemetry & Remote SCADA Solutions 48 Steacie Drive, Kanata, Ontario K2K 2A9 Canada Direct Worldwide: 1 (613) 591-1943 Fax: 1 (613) 591-1022 Toll Free within North America: 1 (888) 267-2232 www.schneider-electric.com Document Number TBULM01012-28 This document has been printed on recycled paper April 2011 tk 2011 Schneider Electric. All rights reserved.