DOE Award Number: TITLE PAGE. Phase I Topical Report. Don L. Hanosh



Similar documents
Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2

VOYAGER 570G. 744A Sprayer Control

Radioactive Waste Storage Facility and Tank System Design Criteria Standards

ANAEROBIC/ANOXIC TANKS

Drilling Rigs and Well Technology. RAPID RIGS AND WELL TECHNOLOGY Cairn India Limited.

Enhanced Oil Recovery (EOR) in Tight Oil: Lessons Learned from Pilot Tests in the Bakken

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

IRRIGATION PUMPING Table of Contents - Section 900

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Maryland Containment System Testing Protocol. The individual performing the inspection and testing as outlined in this protocol must be either:

Specifications for Residential Property Owners Connection to New Public Sewer

How To Use A Water Source Heat Pump

AE-1483 Ground-source Heat Pumps. Carl Pedersen Energy Educator

Handbook. Purchasing Guidelines. API Monogram Equipment. Purchase API Specs online at

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Recommended Practices Associated with Hydraulic Fracturing Operations

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

Objectives. Describing Waterflooding. Infill Drilling. Reservoir Life Cycle

Septic Tank Use & Maintenance Tips

Frequently Asked Transmission Pipeline Questions

FLOWBACK & PRODUCTION TESTING SERVICES

Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle

SECTION 22 LIGHTNING PROTECTION SYSTEM

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

OSU Extension FACT SHEET

TABLE OF CONTENT

Understanding and Caring for Your Septic System

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Chapter 1 Introduction

Underground Storage Tanks

NEW SERVICE INSTALLATION STEPS. Common Slow Downs. Other Necessary Steps

MAINTENANCE OF WHEELMOVE IRRIGATION SYSTEMS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Transformer Deluge Systems

I. Introduction. 10 minutes

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

environment briefing02

Exploration for natural gas

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Using Renewable Energy to Pump Water

Floor Heating Warehouse.co.uk

Using Virtualization to Help Move a Data Center

Waste Oil Handling, Spill Containment & Lighting

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Cathodic Protection Use On Tank Bottoms & Underground Piping In Power Generation Plants

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Operators manual Basic water heater

Free Stall Cleaner System with Cable. A new generation of equipment and systems. GEA Farm Equipment Houle

Trailer-mounted or van-integrated

Zero Discharge Water Management for. Horizontal Shale Gas Well Development

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

4" SUBMERSIBLE PUMPS

Specifications for Lightning Protection. ASAE Engineering Practice

Derived Intervention Levels for Tritium Based on Food and Drug Administration Methodology Using ICRP 56 Dose Coefficients (U)

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

V47 Series Temperature Actuated Modulating Water Valves

Tax Executives Institute

MANURE COLLECTION AND TRANSFER SYSTEMS IN LIVESTOCK OPERATIONS WITH DIGESTERS. A. C. Lenkaitis GEA Farm Technologies Inc. (Houle USA), Naperville, IL

Isolation of Battery Chargers Integrated Into Printed Circuit Boards

Vertical Pumps for the Oil & Gas Industry

Contract No: Disclaimer:

SUMP PUMP DISCHARGES INFORMATIONAL PACKET

DEEPSEALSM SERVICE SOLUTIONS

SANTA FE COUNTY'S OIL DEVELOPMENT ZONING ORDINANCE

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

Guidelines for Preparing for a Temporary Steam Plant

SECTION 8 Industrial Facilities Field Investigation

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

CHAPTER 4 WELL COMPLETION AND MAINTENANCE

Construction Specifications for Keyhole Pavement Coring and Reinstatement

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

WWTP RETROFIT. Smith & Loveless Inc. Also in this issue: Do You Have Emergency Backup? Aging Clarifiers Retrofit to Like New

GRU Purchasing Material Group Codes

FLUID FLOW Introduction General Description

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

GAS INSTALLERS MANUAL CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IPS PLASTIC GAS SERVICE PIPING


Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

DEPARTMENT OF CODES AND BUILDING SAFETY FLOOD RECOVERY INFORMATION

Dynamic Vulnerability Assessment

INSTALLATION INSTRUCTIONS

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

2-DFINITE ELEMENT CABLE & BOX IEMP ANALYSIS

LIFELINE PIPELINE RESTORATION AND SEISMIC MITIGATION

Arkansas Natural Gas Severance Marketing Costs

INNOVATIVE ELECTROMAGNETIC SENSORS

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

Self Purging Liquid Trap (SPLT ) User s Manual

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Transcription:

TITLE PAGE Report Title: Using Cable Suspended Submersible Pumps to Reduce Production Costs to Increase Ultimate Recovery in the Red Mountain Field in San Juan Basin Region Type of Report: Phase I Topical Report Reporting Start Date: October 16,2003 Reporting End Date: July 3 1,2004 Principal Authors: Don L. Hanosh Report Issue Date: August 2004 DOE Award Number: DE-FC26-03NT15422 Submitting Organizations: Enerdyne LLC 12814 Central Blvd. SE Albuquerque, NM 87123 1.

DISCLAIMER: This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, expressed or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. ABSTRACT: A joint venture between Enerdyne LLC, a small independent oil and gas producer, and Pumping Solutions Inc., developer of a low volume electric submersible pump, suspended from a cable, both based in Albuquerque, New Mexico, has re-established marginal oil production from the Red Mountain Oil Field, located in the San Juan Basin, New Mexico by working over 17 existing wells and installing submersible pumps. STATElMENT OF PROJECT OBJECTIVES Resume marginal oil production operations in the Red Mountain oil fields located in McKinley County, New Mexico by installing a cable suspended electric submersible pumping system (HDESP), determine if this system can reduce lifi costs making it a more cost effective production system for similar oil fields within the region, and if warranted, drill additional wells to improved the economics. Two Phases of work have been defined in the DOE Form 4600.1 Notice of Financial Assistance Award for this project, in which the project objectives are to be attained through a joint venture between Enerdyne LLC (Enerdyne), owner and operator of the fields and Pumping Solutions Inc. (PSI), developer of the submersible pumping system. Upon analysis of the results of each Phase I, the DOE will determine if the results justify the continuation of the project and approve Phase I1 to proceed or terminate the project and request that the wells be plugged. Ths topical report shall provide the DOE with Phase I results and conclusions reached by Enerdyne. 2.

PHASE I The objective of Phase I was to attempt to establish marginal oil production. This was accomplished by selecting 17 wells Withm the oil fields, removing existing equipment when necessary, cleaning out each casing, treating the pay zone of each well for minor skin damage, temporarily installing a HDESP in each well, and determining the oil cut of the production. And to operate the field for a period of approximately one year to find out if electric submersible pumps are more cost effective to operate verse a typical beam pump system. HDESP A newly developed pumping system, the HDESP consists of a 3 % diameter light weight low volume electric submersible oil well pump that functions by hydraulically actuating diaphragms with st small hydraulic pump and electric motor. This gives the pump the ability to pump low viscosity fluids as well as abrasives given up by the reservoir. By increasing the length of the diaphragms and or the size of the electric motor, the pumping capacity increases. Its stainless steel construction allows the pump to be deployed in corrosive down hole environments without damage to the components. It is suspended, in the well, using a!a D stainless steel cable to which the electric power cable and 5/8 reinforced polyethylene tubing, with a burst pressure of 2500 psi, are tied. The stainless steel cable is tied off at the wellhead while the power cable and tubing pass through. The entire system can be deployed, continuously, by one man operating the CSPS trailer, a 16 winch trailer that is equipped with hydraulically actuated spools that feed or gather the cables and tubing simultaneously. For this project, the HDESP appears to be perfectly suited to handle the field conditions and reservoir characteristics of the Red Mountain: the lack of reservoir pressure that exists due to the shallow nature of the pay requires a pump that can pump off without damagmg the pump. Those wells that experience sand entry into the wellbore from the formation require a pump that will not jxematwely wear out from sand abrasion to its components. During the winter months it is extremely dificult to prevent low volume wells, that produce fresh water, from freezing and splitting wellhead fittings and valves or metal flow lines, therefore a production system is needed that is not exposed to weather conditions. And, because the field is remote, a production system that has no above ground moving parts that require maintenance or can harm livestock or other native animals is most beneficial. At the date of this report all HDESP pumps are pumping with exception of one that was lost down hole during installation and one other that apparently has experienced a down hole electric motor wiring failure. 3.

Well Tie-in After a HDESP was installed, a 4 x 18 x 32 concrete pad, designed with openings to fit around the wellhead and also allow the electric cable and tubing to pass through, was place over the wellhead, production tubing and power cable, and the well was tied-into a power supply and gathering system. A 20 amp disconnect and 240 volt timer were mounted adjacent to the starter on the wooden post and wired together through plastic flex conduit. A power supply cable was run to the well in a 24 deep trench from the main power souce, buried and then wired into the &sconnect. The production tubing was coupled and run, underground, to a production tank. The wellhead was then covered by bolting a 8 x l6 x 22 metal box to the concrete base. The location was fenced with pipe panels or t-posts and barbed wire and the well was produced for approximately one hour per day. RESULTS HDESP Only one HDESP pump has failed to date. It apparently has an electric motor wiring problem down hole because it will not operate past the start mode. Production The original pian for oil production was to allow each well to pump for a couple of days or until the well pumped off and then calculate the oil cut. The results would determine if the well was economic. It was found that the typical well made 8+ bbls. of fluid per day in the first four weeks of initial production, with the pump operating two hours per day. The average oil cut was calculated at 15%. With a few weeks of pumping, the production tanks would be full and the produced water would require disposal. Once all wells were online, it was apparent that the volume of produced water was too great to manage. Therefore addrtional tanks have been placed within the field to handle tfie fluid volume, after all the wells were tie-in permanently. Approximately 6000 of electrical cable and flow line were laid and buried within 24 deep trenches to permanently tie-in the producing wells. This task consumed most of the summer months. During this process, most wells were required to be shut-in and or produced sporadically. Currently, all producing wells are tie-in and capable of producing. 4.

Economics With current oil prices, the field is marginally profitable. Oil production is at approximately 6 BOPD with the potential of 15-20 BOPD once all wells are allowed to produce on a regular extended schedule. The big question, as in the past, is what to do with the produced water. Because the Red Mountain is unique, in that oil occurs with fresh water, a plan is being designed to put the fresh water to a beneficial use on the surface that will have a positive impact economically. CONCLUSIONS & RECOMMENDATIONS Oil Production Marginal oil production has been re-established at the Red Mountain Oil Field using the cable suspended pumping system. However, in the previous topical report, it was recommended that in order fur the field to be economic, produced water must be reintroduced into the reservoir to maintain reservoir pressure to increase oil production and as a method of water disposal. This recommendation may still be necessary. But, gwen the present need for fiesh water in northwestern New Mexico, more specifically, the Navajo Nation, it is prudent to take full advantage of this basic resource. Although the produced water is suitable or livestock consumption as is, a more beneficial use is now under consideration. With assistance from the United States Department of Agriculture, an area will be designated for a fann plan. The soil will be analyzed to determine a suitable crop, given existing conditions, and determine the chemical content of the produced water to find out if there are any dissolved solids the would hinder plant growth. Once this information is gathered, a farm plan can be designed for the quantity of water the field is capable of malung. If this type of plan can be implemented, it would improve the economics of the field significantly. 5.