Application Procedures For Electricity Connection To Consumers Electrical Installations In The New Electricity Market



Similar documents
How to Apply For Electricity Connection

APPLICATION FOR RENEWAL OF LICENCE TO USE OR OPERATE AN ELECTRICAL INSTALLATION (Please read Explanatory Notes before completing the Forms)

Application of Electrical Installation Licence

METERING CODE. Energy Market Authority of Singapore

This letter accompanies Ofgem's attached section 11A formal licence modification notice and also details:

Connecting to the network information pack Version 2

TRANSMISSION SERVICE RATE SCHEDULE Effective from 1 April 2015

KERALA STATE ELECTRICITY REGULATORY COMMISSION

(dd/mm/yyyy) Landlord (1) Name: NRIC No. (4) : Address: Landlord (2) Name: NRIC No. (4) : Address: Landlord (3) Name: NRIC No.

Effective 15 Jul 2015 Conditions of Service for Contestable Consumers

PROPERTY MANAGEMENT AGREEMENT [HEREINAFTER REFERRED TO AS. hereby appoint QUADRANT PROPERTY MANAGEMENT LTD

11. Assessment of service 12. S-phase supply 13. Water heaters NORTHERN TERRITORY OF AUSTRALIA ELECTRICITY BY-LAWS T ABLE OF PROVISIONS

LANDLORD INFORMATION PACK FOR RESIDENTIAL LETTINGS AND PROPERTY MANAGEMENT

Competition in Electricity Supply: State of Play

KERALA STATE ELECTRICITY REGULATORY COMMISSION

BANK Of ZAMBIA REQUIREMENTS FOR DESIGNATING A PAYMENT SYSTEM

LANDLORD AGENT AGREEMENT

New electricity connection, substantial increase in load and major headworks

NORTHERN IRELAND ELECTRICITY Ltd STATEMENT OF CHARGES FOR USE OF. THE NORTHERN IRELAND ELECTRICITY Ltd ELECTRICITY DISTRIBUTION SYSTEM

A Guide To Your Real Estate Purchase

Dated Tuesday, 24 March 2015

I USE OF SYSTEM CHARGES EFFECTIVE FROM 1 APRIL 2015

SoftNET APPLICATION FOR SUBSCRIBING TO SOFTNET OF SOFTWARE TECHNOLOGY PARK GUWAHATI

ASIC Corporations (Distribution of Basic Deposit and General Insurance Products) Instrument 2015/XX

CITY GAS HANDBOOK ON GAS SUPPLY. Version 2

MAP06/07 End-to-End Process Diagram (E2E) Change Proposal Form

SA Power Networks Planning for Solar PV? Customer information guide to network connected solar PV inverter systems

Customer Installation Safety Plan. March 2015

Distributed Generation Standards under the ENC Licence

APPLICATION FORM FOR SIPP CLIENTS

Robertson Property Management Sole Agency Agreement

KEPPEL GAS GAS SUPPLY HANDBOOK

China Company Registration Package #FICE102 - Shanghai Trading Company Registration and Bank Account Opening

RISK PURCHASING GROUP REGISTRATION PACKET

STANDARD INTERCONNECTION AGREEMENT FOR CUSTOMER-OWNED TIER 2 RENEWABLE GENERATION SYSTEMS (Greater than 10 kw and Less than or Equal to 100 kw)

Application for Self-Exclusion from Non-Casino Gambling Operators

Leasing scheme information

TERMS AND CONDITIONS

Model Renewable Energy Wheeling Agreement under Renewable Energy Certificate (REC) scheme

INSURANCE (INSURANCE AGENTS) RULES 2009 ARRANGEMENT OF RULES PART I - PRELIMINARY PART II - DUTIES OF AN INSURANCE AGENT

Green Power Connection Net Energy Metering Engineering Review Process in Delaware and Speeding Up the Application Fee Process

THE GAMING AND POOL BETTING (CONTROL AND TAXATION) ACT. Statutory Instrument The Gaming and Pool Betting (Control and Taxation) Regulations.

GUYANA No. of 2011 REGULATIONS. Made Under. CREDIT REPORTING ACT (Cap. 84:01)

CONSULTATION PAPER FOR PROPOSED MODIFICATIONS TO THE TRANSMISSION CODE

Company Account Opening Form

Charges for Water and Sewerage Services to Non- Household Premises 2015/16

MAHARASHTRA ELECTRICITY REGULATORY COMMISSION, MUMBAI

SCHEDULE FIT TIER 1 AND TIER 2

Re: Connection to the Electricity Distribution System at: [GV_SINGLE_LINE_ADDR_PREM]

How To Connect A Distributed Generation Facility In Illinois

ELECTRICITY [CH

Unitil Energy Systems, Inc. Interconnection Standards For Inverters Sized Up To 100 kva

MEDIUM VOLTAGE SUBSTATION PRACTICES Medium Voltage (MV) is defined as: 1000V< MV 44kV

Vision. Mission. Shared values

SCHUYLER DEPARTMENT OF UTILITIES SCHUYLER, NEBRASKA ELECTRIC RATES

Standard terms and conditions

RESIDENTIAL SERVICE SCHEDULE R

STATEMENT OF CHARGING METHODOLOGY FOR USE OF ELECTRICITY NORTH WEST LIMITED S ELECTRICITY DISTRIBUTION NETWORK

THE SUSTAINABLE ENERGY AUTHORITY OF IRELAND PURCHASE ORDER TERMS AND CONDITIONS OF PURCHASE

Declaration of beneficial ownership

CENTRAL BANK OF CYPRUS

Schedule GS-3 LARGE GENERAL SERVICE SECONDARY VOLTAGE I. APPLICABILITY AND AVAILABILITY

TENDER DOCUMENTS PROCUREMENT OF GOODS PRICE QUOTATIONS. Public Procurement Board. Accra, Ghana

A Supplier Guide to Providing Services and Commodities to NEW YORK UNIVERSITY F&CM CONTRACT MANAGEMENT

Standard conditions of the Electricity Distribution Licence

Title 20 PUBLIC SERVICE COMMISSION. Subtitle 50 SERVICE SUPPLIED BY ELECTRIC COMPANIES. Chapter 02 Engineering

NORTH CAROLINA INTERCONNECTION PROCEDURES, FORMS, AND AGREEMENTS. For State-Jurisdictional Generator Interconnections. Effective June 16, 2009

Cannon SuperDogs Investment Application

Standard conditions of electricity supply licence

Account-Opening For Non-individual Customers

Networks. ESB Networks Ltd Basis of Charges for Connection to the Distribution System. Commercial and Customer Asset Management ESB Networks Ltd.

GAUTENG PROVINCE DEPARTMENT OF ECONOMIC DEVELOPMENT. GAUTENG LIQUOR ACT, 2013 (ACT No. OF 2013) GAUTENG LIQUOR REGULATIONS, 2013

Smart Meters Programme Schedule 2.5. (Security Management Plan) (CSP South version)

SOUTH DAKOTA DIVISION OF INSURANCE 124 S Euclid Ave, 2 ND Floor Pierre, South Dakota (605)

2015 No ELECTRICITY GAS. The Electricity and Gas (Standards of Performance) (Suppliers) Regulations 2015

BUSINESS BANKING FACILITIES APPLICATION FORM

Date of submission of IDA Application: Note: LMEP submission must be prior to IDA Resolution

MANDATORY PROVIDENT FUND SCHEMES AUTHORITY. IV.25 Guidelines on Electronic System for Transmission of Data on Transfer of Accrued Benefits

Application for Approved (Overseas/Local) Third Party Inspection Agency for Lifting Equipment

This document explains the service you are being offered and how you will pay for it.

NOTICE 658 OF 2015 INDEPENDENT COMMUNICATIONS AUTHORITY OF SOUTH AFRICA ELECTRONIC COMMUNICATIONS ACT, 2005 (ACT NO. 36 OF 2005), AS AMENDED:

Daily Daily Network Network Network Energy Rates Step Rates Capacity. Price Rates Rates

GAS SUPPLY CODE. Energy Market Authority Of Singapore

To complete the process for a net metering interconnection, please follow the steps below:

PROCEDURES ON IMPORTATION AND REGISTRATION OF A CLASSIC CAR IN SINGAPORE

Schedule 6VP LARGE GENERAL SERVICE VARIABLE PRICING

MANDATE KAAP AGRI LIMITED. INSTRUCTION TO BUY and/or SELL SHARES

ATTACHMENT G. Network Operating Agreement

New York invoice. Date: Thursday, October 10, 2013 Invoice No: Professional services rendered Notes Year 1

PPS TAX FREE INVESTMENT ACCOUNT APPLICATION FORM

RENTAL PROPERTY SET UP QUESTIONNAIRE & TERMS OF SERVICE

CORPORATE ACCOUNT. ...we make the difference

BUSINESS BANKING FACILITIES APPLICATION FORM

Account-Opening For Non-individual Customers

Application Form Freelance Photographers

inspect and estimate the rental value of your premises advertise and market as may be necessary

Certified Installer Partnership Code of Practice

Conditions means the standard terms and conditions set out in this document;

Transcription:

Application Procedures For Electricity Connection To Consumers Electrical Installations In The New Electricity Market October 2002 Forms & presentation material will be published in the EMA website www.ema.gov.sg Page 1 of 13

SCOPE OF PRESENTATION 1. Submission of Consultation Form 2. Submission of Application a. For Direct Connection Load 45 kva b. For Indirect Connection Load 45 kva c. For Direct Connection Load > 45 kva d. For Indirect Connection Load > 45 kva Page 2 of 13

SUBMISSION OF CONSULTATION FORM Procedure for New Electricity Market 1. Connection Applicant may seek consultation on the supply scheme & technical requirements at the conceptual level by submitting Consultation Form through the LEW to PowerGrid. 2. PowerGrid needs info such as site plan, gross floor area, usage of premises, supply requirement & expected date of completion. Page 3 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD 45 kva 1. The LEW shall submit an Application Form with 2 copies of site plan, on behalf of the customer, when applying for a new or modified connection to the Transmission System. 2. PSL shall endeavour to send the quotation for electricity supply connection to the customer within 10 business days. 3. Customer pays Service Connection Charge within the validity period of the quotation. Page 4 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD 45 kva 4. Upon receipt of payment, PowerGrid will commence work and inform the customer and LEW on completion 5. Customer has to open an account and pay deposit to PSL if he has not already done so. The LEW shall submit a copy of Certificate of Compliance(COC) and Application for Inspection of Electrical Installation Form (CS/5) on behalf of the customer. (Please note: First-time inspection is free-of-charge, however re-inspection will be charged accordingly.) Page 5 of 13

SUBMISSION OF APPLICATION FOR INDIRECT CONNECTION LOAD 45 kva 1. Customer to open an account and pay deposit to PSL if he has not already done so. 2. The LEW shall submit a copy of Certificate of Compliance(COC) and Application for Inspection of Electrical Installation Form (CS/5) on behalf of the customer together with the landlord s consent on Form CS/3 or CS/3H and book an appointment for inspection and turn-on. (Please note: First-time inspection is free-of-charge, however re-inspection will be charged accordingly.) Page 6 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD > 45 kva 1. The LEW shall submit an Application Form with 2 copies of site plan, on behalf of the customer. 2. PSL shall advise the LEW & customer on the approval of the application & technical requirements within 10 business days for connections up to 22kV, within 60 business days for 66kV connections and within 100 business days for 230kV connections. For Non-Contestable Customer 3. For Service without sub-station, the procedure is the same as for Direct Connection Load 45 kva. 4. For Service with sub-station, LEW shall proceed to submit sub-station plan & metering requirements to PowerGrid for clearance. Page 7 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD > 45 kva For Non-Contestable Customer 5. PSL shall send the Quotation, Supply Agreement & Deposit amount required for Opening of A/C to customer. 6. On receipt of payment of service connection charge & signed supply agreement, PowerGrid will commence work & inform LEW & customer on completion. 7. Customer shall proceed to open an account with PSL and apply to EMA for LEI. 8. LEW submits a copy of Certificate of Compliance (COC) and books an appointment for energisation of service connection at PSL Installation Section, St James Office. Page 8 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD > 45 kva For Contestable Customer 3. All customers must make an application to PSL for classification as Contestable Customer. 4. Upon classification as a Contestable Consumer, PSL shall send the Quotation, Consumer Connection Agreement (CCA), Opening of A/C Form, GIRO Form, & Request For Installation of Meter Form (CS/6) to customer. 5. On receipt of payment of service connection charge & signed Consumer Connection Agreement, PowerGrid will commence work & inform LEW & customer on completion. 6. The customer shall subscribe and install one dedicated telephone line per metering point to be used for the purpose of remote meter reading. Page 9 of 13

SUBMISSION OF APPLICATION FOR DIRECT CONNECTION LOAD > 45 kva For Contestable Customer 7. Customer submits the application form to open an a/c together with a security deposit (if applicable) to PSL. LEW is also required to submit copy of the duly completed Form CS/6 to PSL. LEW shall liaise directly with PowerGrid to install meter. 8. PSL notifies LEW to apply to EMA for LEI. 9. LEW books an appointment for energisation of service connection at PSL Installation Section, St James Office. Page 10 of 13

SUBMISSION OF APPLICATION FOR INDIRECT CONNECTION LOAD > 45 kva 1. When the premises is ready for installation of meters, the LEW/Customer has to open an account and pay deposit to PSL if he has not already done so and submit Form CS/7 for Request for Installation of Meter. 2. The LEW shall proceed to liaise with the Meter Section of PowerGrid to have the meters installed. 3. PSL shall then advise LEW to proceed to apply to EMA for LEI before the supply is turned on. 4. After the meters are installed, the LEW shall submit a copy of Certificate of Compliance and confirm the account activation date(which is the proposed turn-on date), with PSL. Page 11 of 13

SUBMISSION OF APPLICATION FOR INDIRECT CONNECTION LOAD > 45 kva 5. The LEW shall be responsible for arranging the energisation of the service connection with the relevant party where the connection is taken via landlord s switchboard such as HDB, JTC or private multimetered buildings. 6. Landlord s LEW will issue Statement of Turn-on of Electricity upon successful turn-on. Impt: For Contestable Customer, the customer shall subscribe and install a dedicated telephone line per metering point to be used for the purpose of remote metering. Page 12 of 13

THE END These procedures and forms can be obtained from the Handbook. For more information on Supply Application & Contract, you can refer to the Handbook How to apply for Electricity Connection or contact PSL at 68238284/68238340. (PowerGrid is finalising on the Handbook and will soon make it available.) Page 13 of 13

CERTIFICATE OF COMPLIANCE [Regulation 5(2) of the Electricity (Electrical Installations) Regulations 2002] Particulars of Electrical Installation Name of Consumer : Address of Installation : Electrical Installation Licence No. MSS Account No. Approved load & Supply Voltage: kw Volts Generator(s) Installed: Operated in parallel with PowerGrid s supply. No. of generator: Rating: kva Standby generator. No. of generator: Rating: kva Not applicable Certification by Licensed Electrical Worker I certify that the above-mentioned Electrical Installation complies with the requirements of the Electricity (Electrical Installations) Regulations 2003 and the Singapore Standards CP 5. I further certify that the technical requirements as stipulated by the person responsible for turning on the switchgear which controls the supply of electricity to the said electrical installation have been complied with. I hereby request for the energisation of the supply line to the said Electrical Installation on (date). Name & Signature of LEW Licence No. Date Copy to: Market Support Services Licensee REF: E(EW)REG R5(2)

STATEMENT OF TURN-ON OF ELECTRICITY [Regulation 5(4) of the Electricity (Electrical Installations) Regulations 2002] ELECTRICITY SUPPLY TO (Name of Applicant) AT (Address of Installation) ELECTRICAL INSTALLATION LICENCE NO* : I agree that the above-mentioned electrical installation is suitable for connection to the electrical system. I certify that the supply line to the installation has been energised on at. (date) (time) Name & Signature of person responsible for Licence No. Date energisation of supply line I acknowledge that the supply line has been energised on the date and time indicated above. Name & Signature of LEW requesting for Licence No. Date energisation of supply line I acknowledge that the supply line has been energised on the date and time indicated above and confirm that I will be responsible for the operation of this electrical installation hereafter. Name & Signature of LEW responsible for the Licence No. Date operation of the electrical installation* I acknowledge that the supply line has been energised on the date and time indicated above. Name & Signature of Applicant NRIC / Passport No. Date * This form is applicable to an electrical installation exceeding 45 kva or a licensed electrical installation. REF: E(EI)REG R5(3)