Redundant Array of Independent Disks (RAID)



Similar documents
Samsung Data Migration v.3.0 Introduction and Installation Guide

Samsung Magician v.4.5 Introduction and Installation Guide

RAID Basics Training Guide

technology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels

Samsung Portable SSD T1

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

Intel RAID SSD Cache Controller RCS25ZB040

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

RAID 6 with HP Advanced Data Guarding technology:

How To Create A Multi Disk Raid

Benefits of Intel Matrix Storage Technology

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

Intel RAID Software User s Guide:

RAID Storage System of Standalone NVR

IBM ^ xseries ServeRAID Technology

Intel RAID Controllers

User Guide - English. Embedded MegaRAID Software

SAN Conceptual and Design Basics

USER S GUIDE. MegaRAID SAS Software. June 2007 Version , Rev. B

IncidentMonitor Server Specification Datasheet

How to choose the right RAID for your Dedicated Server

ServeRAID H1110 SAS/SATA Controller for IBM System x IBM System x at-a-glance guide

ServeRAID M5015 and M5014 SAS/SATA Controllers for IBM System x IBM Redbooks Product Guide

TECHNOLOGY BRIEF. Compaq RAID on a Chip Technology EXECUTIVE SUMMARY CONTENTS

Samsung SSD Magician DC. User guide Ver Samsung Electronics Co.

High Availability Server Clustering Solutions

Enclosure Management Cabling Guide for Intel C200 and C600 Series Chipset Based Server Systems with Hot-Swap Drive Enclosures

Performance Brief: MegaRAID SAS 9265/9285 Series

RAID HARDWARE. On board SATA RAID controller. RAID drive caddy (hot swappable) SATA RAID controller card. Anne Watson 1

Configuring RAID for Optimal Performance

ZOTAC RAIDbox User s Manual

Guide to SATA Hard Disks Installation and RAID Configuration

Intel RAID. INTEL raid

Intel RAID Software User s Guide:

Intel RAID Software User s Guide:

PIONEER RESEARCH & DEVELOPMENT GROUP

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

RAID: Redundant Arrays of Independent Disks

Guide to SATA Hard Disks Installation and RAID Configuration

Intel RAID Software User s Guide:

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

RAID Technology Overview

Intel RAID Software User s Guide:

GENERAL INFORMATION COPYRIGHT... 3 NOTICES... 3 XD5 PRECAUTIONS... 3 INTRODUCTION... 4 FEATURES... 4 SYSTEM REQUIREMENT... 4

Configuring ThinkServer RAID 100 on the TS140 and TS440

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

This chapter explains how to update device drivers and apply hotfix.

PENTEK S TALON 27XX SERIES RECORDING SYSTEMS

SSDs and RAID: What s the right strategy. Paul Goodwin VP Product Development Avant Technology

Configuring ThinkServer RAID 100 on the Lenovo TS430

HP Smart Array Controllers and basic RAID performance factors

QuickSpecs. PCIe Solid State Drives for HP Workstations

RAID Utility User Guide. Instructions for setting up RAID volumes on a computer with a Mac Pro RAID Card or Xserve RAID Card

Getting Started With RAID

Hardware RAID vs. Software RAID: Which Implementation is Best for my Application?

RAID Utility User s Guide Instructions for setting up RAID volumes on a computer with a MacPro RAID Card or Xserve RAID Card.

RAID EzAssist Configuration Utility Quick Configuration Guide

Definition of RAID Levels

Performance Report Modular RAID for PRIMERGY

High-Performance SSD-Based RAID Storage. Madhukar Gunjan Chakhaiyar Product Test Architect

Accelerating Server Storage Performance on Lenovo ThinkServer

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

Intel Solid- State Drive Data Center P3700 Series NVMe Hybrid Storage Performance

Intel RAID Software User s Guide:

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Best Practices for Optimizing SQL Server Database Performance with the LSI WarpDrive Acceleration Card

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

WebBIOS Configuration Utility Guide

Converged storage architecture for Oracle RAC based on NVMe SSDs and standard x86 servers

Storage is in Our DNA. Industry-leading 12Gb/s and 6Gb/s Storage Solutions RAID Adapters, Host Bus Adapters, and SAS Expander

Intel Rapid Storage Technology

MSM Software Feature Difference Between the MR Controller and the IR Controller

The Shortcut Guide to Balancing Storage Costs and Performance with Hybrid Storage

Implementing Enterprise Disk Arrays Using Open Source Software. Marc Smith Mott Community College - Flint, MI Merit Member Conference 2012

RAID 5 rebuild performance in ProLiant

Intel RAID Premium Features

White Paper A New RAID Configuration for Rimage Professional 5410N and Producer IV Systems November 2012

AirWave 7.7. Server Sizing Guide

Accomplish Optimal I/O Performance on SAS 9.3 with

RAID OPTION ROM USER MANUAL. Version 1.6

Storage Technologies for Video Surveillance

The Revival of Direct Attached Storage for Oracle Databases

an analysis of RAID 5DP

Optimizing SQL Server AlwaysOn Implementations with OCZ s ZD-XL SQL Accelerator

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

Intel RAID Web Console 2 and StorCLI Command Line Tool

Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations. Database Solutions Engineering

Intel Matrix Storage Manager 8.x

Distribution One Server Requirements

WHITE PAPER FUJITSU PRIMERGY SERVER BASICS OF DISK I/O PERFORMANCE

An Affordable Commodity Network Attached Storage Solution for Biological Research Environments.

MegaRAID Configuration Software

ServeRAID M5000 Series Performance Accelerator Key for IBM System x Product Guide

MS Exchange Server Acceleration

NVMe SSD User Installation Guide

DELL TM PowerEdge TM T Mailbox Resiliency Exchange 2010 Storage Solution

Dell SAS RAID Storage Manager. User s Guide. support.dell.com

Transcription:

For Data Centers Redundant Array of Independent Disks (RAID) Combine and control multiple storage devices for better performance and reliability Application note 2014 Samsung Electronics Co.

1. What is? RAID is a disk configuration technology that contains multiple disk drives as an array and operates using striping and/or mirroring methods to provide better performance, error tolerance and more storage capacity at a moderate cost. RAID is widely used as a storage solution in servers and storage systems for stability and performance improvement. 2. What are the different operating methods RAID uses? RAID uses the following operating methods : - Striping : Dividing a body of data into blocks and spreading the data blocks across several partitions on numerous drives. Striping is primarily used to increase performance. - Mirroring : Replicating data onto two or more disks to provide good fault tolerance. Data mirroring can be performed without data loss or system stoppages if a fault occurs. According to the disk configuration methods when using striping and mirroring, RAID can be differentiated into the following levels. (Only some levels are described below.) 1) RAID 0 RAID 0 writes data to two or more drives alternately to provide the best performance. RAID 0 has a simple design, is easier to implement and has no overheads for parity. However, data is stored on only one disk. So, if one disk fails, data stored within those disks is lost since it does not use parity. For this reason, RAID 0 has very limited usage, like an SSD read cache. 2) RAID 1 RAID 1 provides a redundant, identical copy of a disk, yielding good fault tolerance. Replacement of a faulty disk does not affect any data loss or system stoppages. However, usable capacity is limited by the smallest capacity and the write performance is lower than RAID 0 since it writes data twice. Also, RAID 1 has a large storage overhead and a high cost/capacity ratio. 3) RAID 5 RAID 5 uses disk striping with parity across three or more disks. Data redundancy is provided by the parity information. Since data and parity information are arranged on the disk array, two types of information are always on different disks. If one disk fails, just replace it with a new disk and the array rebuilds itself. RAID 5 has a higher read rate and makes good use of capacity. The drawbacks of RAID 5 are slower write rates and slower rebuild times. 01 Samsung SSD Application Note for Data Centers

4) RAID 10 (1+0) RAID 10 is a combination of RAID 1 (mirroring) and RAID 0 (striping). RAID 10 uses a striped array of disks, which mirrors identical sets of striped disks. This array level uses at least four disks, and additional disks must be added in even numbers. The data is first placed into mirrored pairs at the lower level. Next, the controller selects a member from each mirrored pair and stripes the data into a new logical volume. Since RAID 10 writes in a random fashion, it performs best with a write-intensive application. The drawback is that RAID 10 is expensive. 3. How do I use the RAID feature? RAID technology also can be differentiated into software RAID and hardware RAID by a management authority, but it uses the same RAID configuration levels described in the previous chapter. - Software RAID : Generally, the operating system (OS) manages the RAID group using the CPU resource of the server or storage system. The Linux OS normally supports software RAID 0, RAID 1, RAID 5, RAID 6 and more, while the Microsoft Windows OS supports RAID 0, RAID 1, RAID 5, etc. - Hardware RAID : Hardware RAID is managed by RAID-supporting Host Bus Adapters (HBAs), and their supportable RAID level is different by specification of the RAID on Chip (RoC) in the HBAs. Since hardware RAID uses the RoC resource, it offloads the CPU in the system. Most importantly, users should determine their suitable RAID configuration by considering the required storage capacity, performance, cost and mean time between failures (MTBF) of the drives. Below is a table that describes each RAID s characteristics for reference. RAID level Minimum required drives Fault tolerance* Random performance Sequential performance Storage utilization Cost RAID 0 2 None 100% $ RAID 1 2 50% $ RAID 5 3 (R) (W) 67-94% (N-1)/N % $$ RAID 6 4 (R) (W) 50-88% (N-2)/N % $$$$ RAID 10/01 4 50% $$$$ * Fault tolerance : Keep in mind that RAID is not a replacement for backups. Backups are essential for any system. 02 Samsung SSD Application Note for Data Centers

4. Samsung SSDs for data centers are Samsung SSD 845DC PRO and 845DC EVO support RAID at any level and are compatible with the most used HBA and RAID controller card products. The table below describes the interoperable HBA and RAID controller card models. The compatibility list will be updated continuously. HBA and RAID controller Samsung SSD Manufacturer Product category 6Gb/s SATA + SAS HBA HBA 12Gb/s SATA + SAS HBA LSI RAID controller card (6Gb/s) 845DC EVO RAID controller card (12Gb/s) Intel RAID controller card (6Gb/s) Model LSI SAS 9206-16e LSI SAS 9207-4i4e/8i/8e LSI SAS 9205-8e LSI SAS 9212-4i4e LSI SAS 9201-16e/16i LSI SAS 9200-8e LSI SAS 9211-4i/8i LSI SAS 9300-4i/4i4e/8i/8e LSI SAS 9311-4i4e (OEM) LSI SAS 9311-8i (OEM) MegaRAID SAS 9240-4i/8i MegaRAID SAS 9286(CV)-8e/8eCC MegaRAID SAS 9270-8i MegaRAID SAS 9271-8i/8iCC/4i MegaRAID SAS 9285(CV)-8e MegaRAID SAS 9266-4i/8i MegaRAID SAS 9265-8i MegaRAID SAS 9280-24i4e/16i4e/8e/4i4e MegaRAID SAS 9260-16i/4i MegaRAID SAS 9260DE-8i MegaRAID SAS 9260CV-8i/4i MegaRAID SAS 9261-8i MegaRAID SAS 9341-4i/8i MegaRAID SAS 9361-4i/8i Intel RAID Controller RS2WC080 Intel RAID Controller RS2WC040 Intel RAID Controller RS25NB008 Intel RAID Controller RS2SG244SNGL Intel RAID Controller RS2WG160 Intel RAID Controller RS2PI008(DE/SNGL) Intel RAID Controller RS2BL080 Intel RAID Controller RS2BL040 Intel RAID Controller RS2MB044 Intel RAID Controller RS2VB080 Intel RAID Controller RS2VB040 Most importantly, to decide which RAID configuration to use, make sure you do your own research so you can make an informed decision on choosing the correct RAID configuration. RAID is not a replacement for backups. Backups are essential for any system. 03 Samsung SSD Application Note for Data Centers

DISCLAIMER SAMSUNG ELECTRONICS RESERVES THE RIGHT TO CHANGE PRODUCTS, INFORMATION AND SPECIFICATIONS WITHOUT NOTICE. Products and specifications discussed herein are for reference purposes only. All information discussed herein may change without notice and is provided on an AS IS basis, without warranties of any kind. This document and all information discussed herein remain the sole and exclusive property of Samsung Electronics. No license of any patent, copyright, mask work, trademark or any other intellectual property right is granted by one party to the other party under this document, by implication, estoppels or otherwise. Samsung products are not intended for use in life support, critical care, medical, safety equipment, or similar applications where product failure could result in loss of life or personal or physical harm, or any military or defense application, or any governmental procurement to which special terms or provisions may apply. For updates or additional information about Samsung products, contact your nearest Samsung office. COPYRIGHT 2014 This material is copyrighted by Samsung Electronics. Any unauthorized reproductions, use or disclosure of this material, or any part thereof, is strictly prohibited and is a violation under copyright law. TRADEMARKS & SERVICE MARKS The Samsung logo is a trademark of Samsung Electronics. Intel is a registered trademark of Intel Corporation. Linux is a registered trademark of Linus Torvalds. Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and/or other countries. All other company and product names may be trademarks of the respective companies with which they are associated. 04 Samsung SSD Application Note for Data Centers