PVC - DR 18 HDPE - DR



Similar documents
MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

INJECTION MOLDING COOLING TIME REDUCTION AND THERMAL STRESS ANALYSIS

RESISTANCE OF PE4710 PIPING TO PRESSURE SURGE EVENTS IN FORCE MAIN APPLICATIONS

SECTION 603 SANITARY SEWER FORCE MAINS

Application Note #49 RF Amplifier Output Voltage, Current, Power, and Impedance Relationship

Mechanical Joint Restraints

PPI TN-27/2009. Frequently Asked Questions. HDPE Pipe for Water Distribution and Transmission Applications

Pressure drop in pipes...

MANUFACTURER'S CERTIFICATION SCHEDULE 40 PVC PIPE And SCHEDULE 80 PVC PIPE

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Ductile Iron Pipe Couplings

Polyethylene Piping Distribution Systems for Components of Liquid Petroleum Gases TR-22

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

EVALUATION ACCORDING TO ASTM F

Notes on Polymer Rheology Outline

Surge Pressure in Plumbing Pipe Materials

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

LEE S SUMMIT USES PIPE BURSTING TO BROADEN ITS ASSET MANAGEMENT TOOLBOX AND REHABILITATE POTABLE WATER DISTRIBUTION SYSTEM

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

PEX Pipes for Service Line Applications

Fatigue Analysis of an Inline Skate Axel

Autodesk BIM 360. Jerker Hägglund, Autodesk Northern Europe AEC/ENI Technical Specialist. Image created in Autodesk 3ds Max software.

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

AN EXPLANATION OF JOINT DIAGRAMS

1.50mm Height 2220 Package Top View Full Color Chip LEDs Technical Data Sheet. Part No.: LL-R5050RGBC-001

Closed Loop Pressure Control for the Extrusion Process

PANTONE Solid to Process

M n = (DP)m = (25,000)( g/mol) = 2.60! 10 6 g/mol

Theory, Application, and Sizing of Air Valves

Pacific Pump and Power

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Modern Construction Materials Prof. Ravindra Gettu Department of Civil Engineering Indian Institute of Technology, Madras

7000 Series Buccaneer

Solid shape molding is not desired in injection molding due to following reasons.

Pantone Matching System Color Chart PMS Colors Used For Printing

Worldwide tank building applications using PP-Sheets: The effect of Foaming on properties

Advances in scmos Camera Technology Benefit Bio Research

How To Color Print

Design Project 2. Sizing of a Bicycle Chain Ring Bolt Set. Statics and Mechanics of Materials I. ENGR 0135 Section 1040.

Figure CPT Equipment

Austin San Antonio Beaumont

DISTRIBUTION PIPING MATERIALS: BUILDING HYDRONIC SYSTEM MANAGEMENT. Jim Riley, Texas A&M University February 10, 2015

Modifying Colors and Symbols in ArcMap

Mineral Insulated Cable A cable for today and tomorrow!

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Polyethylene Pressure Pipe

SORTING PLASTICS FOR RECYCLING INTRODUCTION

What is a mold? Casting. Die casting. Injection Molding Machine. Injection Molding Design & Manufacturing II. Spring 2004

POLY DRUMS. LAB PACK - OVERPACK - SALVAGE DRUMS The Best Drums in the Field CONTENTS: What s the difference?

Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations

Supporting document to NORSOK Standard C-004, Edition 2, May 2013, Section 5.4 Hot air flow

How Management Decisions Make or Break Plant Uptime

3D Printing Design Guidelines Sierra College CACT

10/9/2012. Poultry Farm Water Supply. Alabama Burglar & Alarm System. Industry Upgrades. Drinkers Fans Water Supply

PEX Pipes for Plumbing Applications

Effect of Sterilization Techniques on Polymers

Standard Specifications, Standard Test Methods and Codes for PE (Polyethylene) Piping Systems

Green Thread Product Data

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

Force Main Condition Assessment: New Technologies & Case Studies

PVC PIPE PERFORMANCE FACTORS

ELECTRICAL SAFETY RISK ASSESSMENT

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

STRAUB-PLAST-PRO Technical Manual

PMS Reflex Blue C Mining PMS 8401C

Understanding Plastics Engineering Calculations

FATIGUE CONSIDERATION IN DESIGN

Understanding, Identifying & Analyzing Box & Whisker Plots

Ford Pipe Repair Products The Ford Meter Box Company, Inc.

Open Channel Diffusers

PETROLEUM DISPENSING. Catalog # Supersedes Catalog # Air & Multipurpose General Purpose Heavy Duty Push-on.

Acceleration Introduction: Objectives: Methods:

Long term performance of polymers

Standard Specifications For Private Sewer Laterals

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

AMPLITUDE AND FORCE PROFILING: STUDIES IN ULTRASONIC WELDING OF THERMOPLASTICS

check valve slam A methodology for predicting

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

Secondary Containment Comparison ATI Ultra COAT vs HDPE

SuperTan Extended (STE) Capacitors, Wet Tantalum Capacitors with Hermetic Seal

pvc well casing & drop pipe

MarketSmith Pattern Recognition Users Manual

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard

Activities/ Resources for Unit V: Proportions, Ratios, Probability, Mean and Median

Prestressed Concrete Pipe Fitness for Service and Repair

HANDLEY CURB BOXES. 2 Inch Curb Box Cast Iron Collar. 2 Inch Gas Curb Boxes. 2 Inch Water Curb Boxes. Superior Grade Curb Box Parts and Accessories

Wear Resistant Thermoplastic Compounds

2.0 DESIGN CRITERIA FOR WATER DISTRIBUTION SYSTEMS

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Transcription:

24 22 2 1 PVC - DR 18 - Pressure Class 15 1 4 2 HDPE - DR 17 - Pressure Class 1 2 3 4 5 6 7 8 9 1 When comparing differences in a materials performance characteristics, such as between HDPE and PVC, it is important to make sure that you are making an accurate and equal comparison of the same characteristic exhibited in an identical situation The following graphs are used to show the differences found in the pressure class performance exhibited by HDPE SDR 17 and PVC DR 18 in relation to a common occurrence found in all water distribution systems; that being fluctuations (many time sudden and significant) in the flow velocity of water In the following graphs, the BLUE LINE will depict PVC DR 18 Pressure Class 15 pipe and the ORANGE LINE will depict HDPE SDR 17 Pressure Rated for psi operations It is important for us to note and to understand from the beginning of this comparison that the term PRESSURE CLASS does not - and never has had the same performance definition for HDPE as it does for PVC For the purpose of providing an equitable comparison we will be referring to the WORKING PRESSURE RATING** of each material in an identical system scenario ** NOTE In the most general sense, the WORKING PRESSURE RATING is the maximum pressure you can put a thermoplastic pipe (amorphous and semi-crystalline) under all normal operating conditions and expect no ruptures during its service life (I e field pressure rating, not laboratory)

24 22 2 1 1 PVC DR 18 - Pressure Class 15 Maximum Surge Capacity 188 psi (Operating Pressure + Surge Pressure) (PR) @ fps Maximum Operating Pressure 15 psi @ 2 fps (WPR) 188 (Max Design Pressure) - 38 (2 fps Surge Potential) The surge potential for a 2 fps change in flow velocity = 38 psi (1 fps = approx. 19 psi based on a non-linear scale) The Working Pressure (Maximum Allowable Operating Pressure) must be varied in relation to flow velocity changes in order for PVC to maintain its minimum design life. 4 2 15 (Pressure Class & Max Operating Pressure) 1 2 3 4 5 6 7 8 9 1 PVC - DR 18 The operational limits of PVC are categorized in terms of PRESSURE CLASS The term PRESSURE CLASS indicates the pipe s maximum allowable operating pressure (also known as it s maximum working pressure rating WPR ) and is based on the PVC s pressure rating (maximum operating pressure @ fps with no allowance for surge) minus a surge potential that is calculated from a baseline flow velocity of 2 fps EXAMPLE: PVC - DR 18 - Pressure Class 15 has a long term fatigue service life based on a zero velocity total pressure capacity of 188 psi It has a maximum allowable operating pressure (WP) of 15 psi with a surge allowance of 38 psi based on a 2 fps flow velocity 188 (PR) - 38 (Ps) = 15 (WP) = 15 PC The Pressure Class for a PVC pipe is directly related to the pipes specific DR The ridged PVC material can only accommodate anticipated pressure surges by de-rating the maximum allowable operating pressure (Working Pressure) in direct proportion to any changes experienced in system flow velocities As flow velocities increase more of the PVC pressure capacity is consumed by surge pressure Surge pressures are a result of changes in flow velocity and are approx 19 psi per every 1 fps change in a DR 18 PVC pipe Any increases in flow velocity will require a reduction in the allowable operating pressure (working pressure) in order to ensure that the surge capacity of the material will not be exceeded and the long term fatigue service life will not be reduced

24 22 2 HDPE DR 17 - Pressure Class Maximum Max Surge Capacity 2 psi (Operating Pressure + Surge Pressure) 1 1 4 The Working Pressure (Constant Allowable Operating Pressure) does not need to be varied in relation to flow velocity changes in order for HDPE to achieve its minimum design life. (PR) is determined by a calculation based on the Pipe DR and the HDS with a typical safety factor of 2. (Pressure Class & Constant Operating Pressure) + (2% Safety Factor) 2 1 2 3 4 5 6 7 8 9 1 2 (Max Pressure) HDPE - DR 17 Due to the significant material differences and performance characteristics found in PVC and HDPE, the term PRESSURE CLASS has no equivalent definition that effectively links the two materials together Today, when looking to implement the use of HDPE based on an equivalent PVC Pressure Class, it is imperative that you know beforehand what the range of your WORKING PRESSURES (operational pressures) will be and then you need to match your systems specific operational needs to the performance characteristics of the HDPE s SDR which is typically categorized as the PRESSURE RATING HDPE s PRESSURE RATING is based on its maximum allowable operating pressure and it indicates the upper limit of the pipe s constant operating pressure (also known as it s working pressure rating WPR This PRESSURE RATING not only identifies the constant and sustainable operating pressure that does not have to be changed or reduced in relation to changes in the flow velocity of water; it also includes the pipes ability to accommodate an infinite number of anticipated pressure surges at 15% of its stated operating pressure in addition to accommodating a highly significant number of pressure surges at 2% of its stated operating pressure EXAMPLE: 5 (5% of PR) 15 psi (for infinite surges) (PR) + = (% of PR) 2 psi (for occasional surges)

24 22 2 1 1 4 2 Area Where HDPE & PVC Perform Equally In a system with a Working Pressure (Operating Pressure) up to psi and a water velocity of 5 fps or less 1 2 3 4 5 6 7 8 9 1 Having distinguished the differences in the terms PRESSURE CLASS and PRESSURE RATING as it is used for PVC and HDPE, and having defined some of the performance limitations associated with the interpretations of those terms; we will now look at some of the implications of the two materials using a comparative scenario based on the parameters established by each of the materials related pressure class and pressure rating The first area we will notice is an area where both materials function equally DR for DR The light blue area highlighted in this chart identifies the specific operational range found within a distribution system where HDPE SDR 17 pressure class and PVC DR 18 pressure class 15 will perform equally well You will note that within this area the operating pressures (working pressures) do not exceed psi and the flow velocities do not exceed 5 fps

24 22 2 1 1 4 2 Area Where Static Strength of PVC is Superior to HDPE Area Where HDPE & PVC Perform Equally In a system with a Working Pressure (Operating Pressure) up to psi and a water velocity of 5 fps or less 1 2 3 4 5 6 7 8 9 1 In this chart we are able to identify a small area where the STATIC STRENGTH of the PVC (due to its higher hoop-stress capability) is actually superior to the HDPE It must be noted however that we are talking specifically about static strength not dynamic strength The ridged material characteristic of an amorphous plastic such as PVC makes it an ideal choice for pressure containment systems as long as the system will not experience any dynamic changes or cyclic events (pumps turning on and off - water hammer - etc ) within the system The trade off for having a greater static strength however, is a significant reduction in the fatigue or cyclic resistance of the material It is for this reason that the maximum operating pressure of an amorphous plastic such as PVC must be de-rated in relation to the flow velocities it will experience The surge pressures experienced within a closed system that are associated with sudden or cyclic changes in flow velocity will: a) quickly subject the material to pressures beyond its capacity (short term result), or b) bring the material to its point of fatigue failure (long term result)

24 22 2 1 1 4 2 Area Where Static Strength of PVC is Superior to HDPE Area Where HDPE & PVC Perform Equally In a system with a Working Pressure (Operating Pressure) up to psi and a water velocity of 5 fps or less HDPE DR 17 Safe Area For Infinite Recurring Surges ( fps - 4.7 fps) 1 2 3 4 5 6 7 8 9 1 In this chart we begin to see that the flexible, semi-crystalline material characteristic of HDPE exhibits a higher capacity for tolerating surge pressures This is due to the materials interconnected and entangled molecular structure The unique performance characteristic of the HDPE polymer chains disentangling (flexing) under sudden stress and then returning to its normal state, provides the HDPE with the ability to absorb some of the energy generated by the pressure surge This inherent mechanism provides the HDPE with a built in safety factor for surge stresses As we can see in this graph, up to 15% of the HDPE s Pressure Rating (PR) is safe for an infinite number of cycles This gives HDPE a unique operational area (indicated by the darker blue area) that allows for the working pressure in a HDPE system to remain constant and unchanged at flow velocities of 5 fps and lower with no de-rating required

24 22 2 PVC DR 18 - Pressure Class 15 design Max 188 psi (Operating Pressure + Surge Pressure) 1 1 4 2 Area Where Static Strength of PVC is Superior to HDPE Area Where HDPE & PVC Perform Equally In a system with a Working Pressure (Operating Pressure) up to psi and a water velocity of 5 fps or less HDPE DR 17 Safe Area For Infinite Recurring Surges ( fps - 4.7 fps) PVC DR 18 Must Be De-Rated To Accommodate Operating Pressures In Relation To Flow Velocities Above 5 fps 1 2 3 4 5 6 7 8 9 1 We all know that in the real world most systems are going to experience flow velocities that exceed 5 fps That requires a closer look at the dynamic effect that changes in flow velocity will have on the different pipe materials We stated earlier that as flow velocities increase, the maximum allowable operating pressure (working pressure) in a PVC system must be de-rated in direct proportion to the flow velocity change This critical area is highlighted in red and as can be seen, the maximum allowable working pressure must be significantly reduced in order to accommodate the increases in surge pressure This de-rating and reduction of working pressure must be done so that the maximum working pressure + pressure surge, will not exceed the surge capacity of the pipe system (indicated by dotted green line) and compromise both the systems overall integrity and cause a reduction in the PVC s fatigue life cycle Pressures that go beyond this limit indicated by the green line exceed system limits as defined by the AWWA for PVC pipe (The fatigue life of PVC pipe is not all inclusive It must be calculated for each DR using a specific flow velocity, at a specific static pressure (hoop stress) In the case of DR 18 PC15 - the fatigue life of the PVC pipe is determined to be able to withstand 48,965 surge events before material failure takes place This equates to 2 surge events per day for 5 years or 6 surge events per hour for 15 years) [2 cycles = 1 Surge Event, 97,89 cycles = 48,945 surge events]

24 22 2 1 HDPE DR 17 - Safe Area For Occasional Surges 4.8 fps - 1 fps (> 1 million cycles or 6 cycles per hour for 19 years) 1 Area Where Static Strength of PVC is Superior to HDPE Area Where HDPE & PVC Perform Equally HDPE DR 17 Safe Area For Infinite Recurring Surges PVC DR 18 ( fps - 4.7 fps) 4 Must Be De-Rated To In a system with a Working Pressure Accommodate Operating 2 (Operating Pressure) up to psi and Pressures In Relation To Flow a water velocity of 5 fps or less Velocities Above 5 fps 1 2 3 4 5 6 7 8 9 1 Once again, even with flow velocities exceeding 5fps, the unique performance characteristics of HDPE exhibit a higher tolerance for resisting surge pressures An additional inherent safety factor up to 2% of its Pressure Rating (PR), gives HDPE a unique safety area (indicated by the yellow area) that allows for the operating pressure in a HDPE system to remain constant and unchanged at flow velocities between 5 fps and 1 fps still with no de-rating required All the while maintaining the capability of accepting and resisting a finite yet highly significant number of occasional cyclic events, surge events or sudden changes in pressure without having any impact on the long term performance of the pipe material (Like PVC, the fatigue life of HDPE pipe is not all inclusive It must be calculated for each DR using a specific flow velocity, at a specific static pressure (hoop stress) In the case of SDR 17 - the fatigue life of the HDPE pipe is determined to be able to withstand > 5 million surge events which is equivalent to about 273 surge events per day - or 11 surge events per hour for 5 years - or 6 events per hour for > 19 years ) [2 cycles = 1 Surge Event, 1 million cycles = 5 million surge events]

24 22 2 1 1 4 2 Area Where Static Strength of PVC is Superior to HDPE Area Where HDPE & PVC Perform Equally In a system with a Working Pressure (Operating Pressure) up to psi and a water velocity of 5 fps or less Area where HDPE is superior to PVC PVC DR 18 Must Be De-Rated To Accommodate Operating Pressures In Relation To Flow Velocities Above 5 fps 1 2 3 4 5 6 7 8 9 1 As you can see by the area highlighted in green, what we have is a significant area where DR for DR, the performance capabilities of the HDPE are clearly superior to those of the PVC

Pressure Surge in DR 18 PVC System (Operating at psi @ 8 fps) 24 22 2 Pressures above the green line exceed AWWA limits for PVC pipe according to AWWA C9 & AWWA M23. 221 psi (WP + PS) 1 1 4 PVC PC 15 141 psi ( PS) Maximum Allowable Operating Pressure should not exceed 47 psi psi (WP ) 2 1 2 3 4 5 6 7 8 9 1 PVC - DR 18 Pressure Surge in SDR 17 HDPE System Operating at psi @ 8 fps 24 22 2 1 1 4 Safe Area For Occasional Surges 4.8 fps - 1 fps (> 1 million cycles or 6 cycles per hour for 19 years) Safe Area For Infinite Recurring Surges ( fps - 4.7 fps) HDPE PR 85 psi ( PS) 185 psi (WP + PS) psi (WP ) Operating Pressure does not need to be de-rated! 2 1 2 3 4 5 6 7 8 9 1 HDPE - DR 17

HDPE SDR 17 @ psi @ 1 fps Semi-Crystalline Thermoplastic Pressure Rating - psi Pressure Class - Working Pressure Rating - psi (remains constant no de-rating required) Surge Capacity - 2 psi Total (WP + 5% of Pressure Rating for Infinite Surges, or % of Pressure Rating for Occasional Surges (WP) + (Ps) 85 = 185 psi This falls comfortably within the HDPE Pressure Class s Safe for Occasional Surge zone. Cyclic Resistance to material failure** >1 million events, or 273 events per day for 5 years, or 11 events per hour for 5 years, or 6 events per hour for >19 years Method of Joining Type of Restraints - Heat Fusion - N/A in totally fused system PVC DR 18 @ psi @ 1 fps Amorphous Thermoplastic Pressure Rating @ fps (no surge allowance) - 188 psi Pressure Class - 15 Working Pressure Rating - 15 psi @ 2 fps WP must be decreased to no more than 47 psi because the flow velocity is at 8fps otherwise the surge capacity will be exceeded i.e. (WP) 47 + (Ps) 141 = 188 psi Surge Capacity - (WP) + (Ps) 141 = 221 188 psi Total (WP + Ps) The PVC Prssure Class 15 Surge Capacity in this scenario is exceeded by 33 psi according to AWWA C9 & AWWA M23 Cyclic Resistance** to material failure 48,945 events, or 2 events per day for 5 years, or 6 events per hour for 15 years (assuming WP is correctly adjusted with flow velocity changes otherwise these figures will be significantly reduced) Method of Joining Type of Restraints - Gasketed - Push On - Bolt on, or Thrust Blocks