DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST



Similar documents
The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Minimum Design Criteria for the permitting of Gravity Sewers

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

SANITARY SEWER SPECIFICATIONS

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Chapter 9 Sanitary Sewers

Sanitary Sewer Overflow (SSO) Incident Report Form

CHAPTER 3 STORM DRAINAGE SYSTEMS

FY08 SEWER POINT REPAIRS BID TABULATION

Design of Sewage Pumping Stations by John Zoeller, PE, CEO/President

SECTION FACILITY STORM DRAINAGE PIPING

CITY OF SALEM DEPARTMENT OF PUBLIC WORKS ADMINISTRATIVE RULES CHAPTER 109 DIVISION 003 SANITARY SEWER COLLECTION SYSTEM

OAR52 A-1 (September, 1981)

SECTION 5: SANITARY SEWER SYSTEM DESIGN

CLEANING, INSPECTION, AND TESTING OF SEWERS

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

CHAPTER 6 SEWER SYSTEM DESIGN STANDARDS

CHAPTER 5. Storm Sewer

Land Disturbance, Erosion Control and Stormwater Management Checklist. Walworth County Land Conservation Department

Type of Sewer Systems. Solomon Seyoum

Ameren Callaway Energy Center-Water Treatment Plant Sedimentation Basins #5 &#6, MO , Construction Permit No. CP , Callaway County

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

SEWER LINE EXTENSION DESIGN CHECKLIST

Standards for Water, Sewer, and Sewage Lift Station Design

Module 7: Hydraulic Design of Sewers and Storm Water Drains. Lecture 7 : Hydraulic Design of Sewers and Storm Water Drains

Module 9: Basics of Pumps and Hydraulics Instructor Guide

SECTION 3 SANITARY SEWER DESIGN

Emerging Technologies in Wastewater Collection Systems

Stormwater/Wetland Pond Construction Inspection Checklist

2010 Residential Water Heater Replacement Check List

SECTION 7 UNDERDRAIN SERVICE

CITY UTILITIES DESIGN STANDARDS MANUAL

Fire Pump Plan Review March 2010

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

Recommended Standards for Wastewater Facilities

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION 5 DRAFTING STANDARDS

City of Edmonton Page 1 of 5 Foundation Drain Discharge Collection System Guideline November, 2005

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

SECTION 7- STORM SEWER

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Components of a Basement Flooding Protection Plan: Sewer System Improvements. November 2000

3A General Information A. Concepts... 1 B. Conditions... 1

Town House Center Highway North Huntingdon, PA 15642

SECTION 812 SEWER LINE, MANHOLE AND WET WELL CLEANING

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

TOPOGRAPHICAL SURVEY REPORT - PART OF L.R No. 7413/11 Done on February 2015 at International Union for Conservation of Nature (IUCN) Eastern African

SEWER CLEANING, INSPECTION AND ASSESSMENT

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

2006 Codes. Please verify the following before calling for inspection

City of La Quinta Public Works Department - Storm Drain Plan Review Checklist

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

CITY OF FARMERSVILLE, TEXAS

CHAPTER 11 STORM DRAINAGE

BMP #: Dry Wells / French Drains

SEDIMENT/STORMWATER MANAGEMENT BASIN CONSTRUCTION CHECKLIST

CITY OF ANN ARBOR PUBLIC SERVICES PLAN REVIEW CHECKLIST

8.1.3 General Design Guidelines. The following guidelines shall be used when designing inlets along a street section:

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

SECTION 5 - STORM DRAINS

DESCRIPTION OF STORMWATER STRUCTURAL CONTROLS IN MS4 PERMITS

STORM DRAINS CHAPTER 7

Top 10+ Mistakes of DWV plumbing design

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

Section 2100-Trenching and Tunneling

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

SANITARY SEWER DESIGN CRITERIA AND POLICIES FOR CITY OF PUEBLO, COLORADO

SECTION GRAVITY SANITARY SEWERS

APPENDIX M-2 SANITARY SEWER TECHNICAL MEMORANDUM. Stadium Reconstruction EIR

Section 402. STORM SEWERS

Collection Systems Technology Fact Sheet Sewers, Conventional Gravity

Sewage Compliance Form Instructions

City of Lubbock Public Works Engineering Design Standards and Specifications

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

Specifications for Residential Property Owners Connection to New Public Sewer

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

When Should Examination Preparation Begin?

RECOMMENDED STANDARDS for WASTEWATER FACILITIES

2.0 BASIC CONCEPTS OF OPEN CHANNEL FLOW MEASUREMENT

SANITARY SEWER BACKUP. Causes & Prevention

CLARK COUNTY REGIONAL FLOOD CONTROL DISTRICT HYDROLOGIC CRITERIA AND DRAINAGE DESIGN MANUAL SECTION 800 STORM SEWER SYSTEMS TABLE OF CONTENTS

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

COMBINED SEWER OVERFLOW OPERATIONAL AND MAINTENANCE PLAN SUMMARY

Engineering Specifications February, 2004 Schedule H to Bylaw 7452, Subdivision Bylaw Page 18

Sanitary Waste & Vent TS Friday 9:00am 12:00pm Peter Kraut PE

CHAPTER 11 STORM DRAINAGE

Transcription:

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST CERTIFICATION 1. Did the engineer submit a certificate of completion utilizing the appropriate page of the issued permit? Yes No N/A 2. Was the certificate of completion fully executed by a P.E.? 3. Were the construction record drawings submitted? 4. Were the construction record drawings stamped, signed, and dated by the design engineer? 5. Were the engineering calculations submitted? 6. Were the engineering calculations stamped, signed, and dated by the design engineer? REFERENCES AND DOCUMENTATION 1. Did all materials used in the design comply with accepted standards, good engineering standards, and are they in compliance with 15A NCAC 2H.022, as well as minimum design criteria? PUMP DESIGN 1. Are the pumps designed to convey raw, unscreened wastewater? 2. Does the pump selection meet the duty requirements, as well as the physical and chemical characteristics of the wastewater being conveyed? 3. Are the pumps capable of passing three-inch solids, trash, or stringy materials? 4. If the answer to 3 is no, are mechanical means of solids reduction utilized? (Manual bar screens are not acceptable) - 1 - Final 10-04

5. Are the pump suction and discharge openings a minimum of four inches for all pumps except grinder pumps? NUMBER AND CAPACITY OF PUMPS 1. Are the pumps capable of conveying the peak hourly wastewater flow with the largest single pump out of service? 2. Is the capacity of the pump capable of pumping the built-out design flow? 3. Has a peaking factor of at least 2.5 been used to calculate the peak hourly wastewater flow? 4. Is the pump capable of maintaining a minimum velocity of 2.0 fps through its suction and discharge piping and the force main? PUMP SELECTION METHODOLOGY 1. Were pump curves submitted? 2. Was a system curve plotted? 3. Was static head calculated? 4. Was friction head calculated? 5. Were minor losses (i.e. fittings, valves, etc.) calculated? 6. If applicable, was pressure head calculated? 7. Was total dynamic head calculated? 8. Was the proper Hazen-Williams friction coefficient used? CYCLE AND PUMP RUN TIMES 1. Is automatic pump alternation provided? 2. Are the pumps operating between two and eight times per hour at design daily flow? - 2 - Final 10-04

3. If the pumps cycle less than two times per hour, have odor control and corrosion measures been considered? 4. Are pump run times excessive? SITE SELECTION AND SECURITY 1. Is the pump station site served by a hard surface road with a minimum width of 12 feet, constructed with a minimum of a six-inch layer of compacted ABC stone, and located above the 100-year flood elevation? 2. Is the pump station site/structure secure? 3. Is adequate lighting provided? 4. Are OSHA-required safety placards provided and readily visible? STRUCTURAL DESIGN 1. Are all of the pump station structures protected from vehicular traffic? 2. Are buoyancy calculations for all structures included? 3. Are the structures protected from the 100-year flood by elevating the structures at least 2 feet above that elevation, or provide water tight ports of entry? 4. Are fillets or sloped bottoms of the pump station designed to avoid the accumulation of grit and solids? 5. Are there projections into the wet well that would allow deposition of solids under normal operating conditions? 6. Is there sufficient submergence of the pumps or pump suction piping to prevent vortexing? 7. Is there sufficient submergence of submersible pumps to prevent overheating? 8. Is the wet well of sufficient depth to provide emergency storage volume? - 3 - Final 10-04

PIPING AND VALVES Yes No N/A 1. On pumps, except grinder pumps, is the suction and/or discharge piping a minimum of four inches in diameter and capable of passing three-inch solids? 2. Is the velocity of the wastewater within the suction and/or discharge piping between two and eight feet per second? 3. Is there a full-closing shut-off valve on the discharge piping of each pump, or on the suction piping of each dry well pump? 4. Is there a check valve on the discharge piping of each pump? 5. Are there flexible pipe joints between pump station structures to allow for settlement? 6. Is cross-connection control for potable water provided? APPURTENANCES 1. Can all pumps and equipment be readily removed from the pump station or wet well? VENTILATION 1. Does the pump station have adequate ventilation to meet all codes and standards? 2. Does the pump station have a gooseneck-type vent that has an elevation set two feet above the 100-year flood elevation and contains an insect/bird screen of corrosion-resistant material? 3. For pump stations having a dry well or other enclosed pump station structure into which routine operator entry is required, is a positive pressure ventilation system provided? OTHER EQUIPMENT 1. Does the pump station have a heater(s) and/or humidifier? 2. Is the floor of the pump station sloped to facilitate drainage? - 4 - Final 10-04

3. If gravity drainage is not possible, is the station provided with sump pump? FORCE MAIN DESIGN 1. Except for grinder pumps, is the force main a minimum of four-inch diameter? 2. Is the velocity of the wastewater within the force main a minimum of two feet per second? 3. Is adequate blockage/anchorage supplied? 4. Is protection required for surge and/or water hammer? 5. Are air release and/or vacuum relief valves required? 6. Is there either a minimum of three feet of cover over the force main or ferrous pipe material used? 7. Is adequate separation maintained between the force main, natural features, utilities, etc.? GRAVITY SEWERS 1. Is the collection system designed at built-out flow quantities? 2. Does the downstream sewer receiving the proposed flow have the capacity to carry its peak flow plus the peak flow of the proposed system? 3. If the proposed sewer is a public gravity sewer, is the minimum diameter eight inches? 4. If the proposed sewer is a private gravity sewer, is the minimum diameter six inches? 5. Is ferrous pipe material used if the gravity sewer has less than three feet of cover? 6. Is the gravity sewer designed above minimum slope for the diameter pipe utilized? - 5 - Final 10-04

7. Is the gravity sewer designed to flow half full at average daily design flow? 8. Is the gravity sewer designed to maintain a minimum flow velocity of two feet per second? 9. Is the gravity sewer installed on uniform slope between manholes? 10. When the velocity of the wastewater exceeds 15 feet per second, has high velocity protection been provided? 11. When gravity sewer slopes are equal to or greater than 20 percent, has the sewer been anchored? 12. Does the gravity sewer have straight alignment between manholes? 13. When a smaller sewer joins a larger one, has the larger sewer been lowered sufficiently to maintain the same energy gradient? 14. Have the proper pipe materials and couplings been utilized for the conditions in which the pipe is being installed (e.g. industrial waste, exceptional external loads, etc.)? MANHOLES 1. Does the distance between manholes exceed 425 feet? If so, has documentation been included with the record drawings showing that the owner has the capability to perform cleaning and maintenance at the greater distances? 2. Where cleanouts are utilized in lieu of manholes on private sewers, does the distance between clean outs exceed 100 feet? 3. Is an outside drop pipe, fully encased in concrete (or ferrous material), provided for a sewer entering a manhole 2.5 feet above the manhole invert? 4. Is the minimum diameter of the manhole four feet with a minimum access diameter of 22 inches? 5. Is the minimum diameter for an inside drop manhole five feet? 6. If applicable, is a bench having a minimum slope of ½ inch per foot (4 percent) provided on either side of every manhole channel? - 6 - Final 10-04

7. Is the invert elevation of any service lateral, service connection, or drop manhole pipe above the bench service? 8. Are the manholes protected from a 100-year flood? 9. Where high flow velocities are expected, are the manholes protected against displacement? 10. Where corrosive conditions are expected, are the manholes protected against the corrosive materials? SEWERS IN RELATION TO STREAMS AND OTHER BODIES OF WATER 1. Are the tops of all sewers entering or crossing a stream sufficiently deep below the stream bed to protect the sewer line? 2. Are the sewers located along streams, lakes, or impoundments at least 10 feet outside the stream bank? 3. Is there a minimum of 50 feet between sewers and waters classified as WS-II, WS-III, B, SA, ORW, HGW, or SB? 4. Are the sewer stream crossings as near perpendicular to the stream flow as possible? 5. Are the sewers entering or crossing streams constructed of ferrous pipe with mechanical joints? 6. For aerial crossings, is the sewer protected from freezing and pier supports from frost heave or settlement? 7. Is proper joint technology, such as flanged or restrained joints, adequately supported to prevent excessive flexion, or a combination of both utilized? 8. Are aerial sewers designed such that the bottom of the pipe is above the 25-year flood elevation of the stream? 9. Are anti-seepage collars utilized where there is a potential to drain wetlands? - 7 - Final 10-04

PROTECTION OF POTABLE WATER SUPPLIES AND STORM SEWERS Yes No N/A 1. Are there any physical connections between a public or private water system and a sewer or sewer appurtenance? 2. Is a minimum of 100 feet maintained between any private or public water supply and the proposed sewer? 3. Is ferrous pipe material utilized if a minimum of 100 feet cannot be maintained between a private or public water supply and a proposed sewer? 4. If a sewer is proposed within 200 feet of an existing water works unit, were all basins, wells, or other treatment units shown on the plans? 5. Was the proposed sewer line designed a minimum of 10 feet horizontally from a proposed water main, or was there a minimum distance of 18 inches vertically between the bottom of the waterline and the top of the sewer? (Water and sewer cannot be placed in the same ditch.) 6. If the vertical and horizontal distances between a water line and the proposed sewer line cannot be obtained, do the materials for both the water and sewer ferrous pipe meet the public water supply design standards? 7. Is there a minimum separation of 12 inches between storm sewers and sanitary sewers, or is ferrous pipe material specified? 8. When water and sewer lines cross without maintaining 18 inches separation, is the sewer constructed of ferrous pipe material, or is either the water line or sewer line in a water tight carrier pipe extending 10 feet either side of the crossing? END