ENGINEER S LIST OF APPROVED ITEMS POTABLE WATER SYSTEM



Similar documents
WATER SERVICE 2

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

Section 3510: Reclaimed water Pipes, Valves, and Appurtenances February 11, 2011

SECTION STORM DRAINAGE SYSTEM

Chapter 6 Material Specifications

SECTION POLYVINYL CHLORIDE (PVC) PIPE

INDEX. Sec. No. Items Page Nos.

Standard Specifications for Installation and Repairs of Water and Sewer Service Lines

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

MS-3/2009 HDPE (High Density Polyethylene) Pipe and Fittings Specification for Buried Potable Water

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION PVC PRESSURE PIPE AWWA C900

SECTION FIRE HYDRANTS

September 2012 Brunswick County Engineering Department Revision 1.0. Technical Specification GRAVITY SANITARY SEWER SYSTEM

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

DIVISION 4300 STORM DRAINAGE

Pipe Repair Products A complete selection for all types of pipe

STANDARD SPECIFICATION SECTION POLYVINYL CHLORIDE (PVC) PRESSURE PIPE (AWWA C900)

SECTION PRECAST CONCRETE UTILITY STRUCTURES

For a building with a crawl space, see Figure

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION SANITARY SEWER PIPE

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

MATERIAL SPECIFICATION MANUAL

REFER TO SPECIFICATIONS AND STANDARD PLANS FOR DETAILED WATER METER, METER VAULT, AND SERVICE LINE REQUIREMENTS

Style 07 Zero Flex Rigid Coupling. Style 75 Flexible Coupling. Style 77 Flexible Coupling 11. Description

SECTION DUCTILE IRON PIPE AND FITTINGS

American- Darling 5¼" B-84-B-5.

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

PART C MATERIAL SPECIFICATIONS

SANITARY SEWER SPECIFICATIONS

SECTION DUCTILE-IRON PIPE AND FITTINGS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

8D.1 BALL ANGLE METER VALVES - 3/4" & 1" P B E B B B-24267

Model Specification 509 DRISCOPLEX 4200 and DRISCOPLEX 4300 Gravity Flow Sanitary Sewer

SECTION PRECAST CONCRETE STRUCTURES

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SECTION 603 SANITARY SEWER FORCE MAINS

SECTION 200: STORM SEWER CONSTRUCTION STANDARDS

Engineering Specifications

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

MOBILE AREA WATER AND SEWER SYSTEM. Section 12. Sanitary Sewer Standard Specifications

City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014

Specifications for Residential Property Owners Connection to New Public Sewer

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Morrison Bros. Co. General Product Specifications

Hose Clamps & Fittings

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

SECTION STORM DRAINAGE TABLE OF CONTENTS

SECTION FACILITY STORM DRAINAGE PIPING

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Standard Specifications For Private Sewer Laterals

How To Replace A Reverse Osmosis Water Tank

Wastewater Capital Projects Management Standard Construction Specification

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

PLUMBING VALVES HOUSTON ORLANDO GREENVILLE 800/ / / TOTAL MAINTENANCE SOLUTIONS

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

LIST PRICE BOOK MALLEABLE CAST IRON PRESS FITTINGS FOR SCH BLACK & GALVANIZED STEEL PIPE

APCO SLOW CLOSING AIR/VACUUM VALVES

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

ASTM C76, Class III, Wall B, except as modified herein. Clean natural sand, ASTM C33. Artificial or manufactured sand will not be permitted.

Section 2100-Trenching and Tunneling

SECTION STORM DRAIN SYSTEM

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

08.08 Vic-Check Valves

Copper Meter Resetters

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

Learning Objectives. History of Vacuum Testing for Precast. Vacuum Testing. Terminology and purpose

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

REQUEST FOR QUOTE STANDING OFFER NO SUPPLY AND DELIVERY OF WATERWORKS FITTINGS

Double-Headed Screw 1. 3/4" FIP x 3/4" MIP x 1/4" hole 2. 3/4" Fip x 3/4" MIP. Feed Water Connector 1. 1/2" FIP x 1/2" MIP x 1/4" OD 2. 3.

Rules and Regulations for Water Service Lines Water Services Department

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

ITEM II - SANITARY GRAVITY SEWER PIPE, FITTINGS, & ACCESSORIES

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Ford Service Saddles and Tapping Sleeves

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

TECHNICAL SPECIFICATION

SECTION GROUND WATER STORAGE TANKS

Guide Specification Precast Concrete Products

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Utility Marking Trace Wire Guide

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

General Guidelines for Repairing Buried PE Potable Water Pressure Pipes

Transcription:

ENGINEER S LIST OF APPROVED ITEMS POTABLE WATER SYSTEM General 1. All products must be NSF 61 approved for potable water service 2. All products with brass or bronze must be lead free 3. Advanced written approval from the City Engineer is required to use products. Page 1

Standard 857 Fire Hydrant and Lateral / Fire Hydrant Location 1. Fire Hydrant a. Use: an active fire protection measure. All areas i. Maximum distance from fire hydrant to all sides of structure: 1. Commercial: 450 feet (300 foot supply, 150 foot hose) 2. Residential: 650 feet (500 foot supply, 150 foot hose) ii. Color: 1. Body: Cotati Green to match existing City fire hydrants. 2. Top/Nozzle Caps: Reflective paint color to match NFPA 291 designation, as follows: a. Light Blue: 1,500 gpm or greater (Class AA) b. Green: 1,000 1,499 gpm (Class A) c. Orange: 500 999 gpm (Class B) d. Red: Less than 500 gpm (Class C) iii. Testing: All hydrants shall be flow tested in a manner acceptable to the City, including collection of static and residual system pressures. CLOW F75 CLOW F76 Residential (one 4½-inch and one 2½-inch outlets) Commercial (one 4½-inch and two 2½-inch outlets) Page 2

Standard 863 3/4 & 1 Water Service For 5/8 x 3/4 & 1 Meters 2. Tracing Wire d. Use: to assist in locating pipes and service lines after they have been buried in the ground. e. Specifications iv. TWHN solid core v. Blue vi. Insulated copper wire #14 vii. Fasten to pipe viii. UL listed, CSA Certified f. Approved Products Pro-Trace 3. Tracing Wire Service Splice a. Use: Splicing the copper service tracer wire into the water main copper tracer wire b. Split Nut Specifications i. High strength bronze alloy split nut with copper pressure bar ii. Sized to accommodate splice of two 14 AWG wires iii. UL listed, CSA Certified c. Splice Protector Specifications i. Clamshell-like outer plastic closure to encapsulate the splice ii. UL Approved iii. Specifically designed for electrical applications up to 600 volts or equivalent by providing a permanent water tight seal. d. Approved Products Split Nut Grainger 6CYZ5 e. Approved Products Splice Protector UraSeal ES200SV 4. Water Service Line a. Use: Customer water service line from water main HPDE Only i. Blue ii. AWWA C901 / ASTM D2737 iii. PE4710 High Density Polyethylene (HDPE) iv. SDR 9 (250 psi pressure class) Page 3

Standard 863 3/4 & 1 Water Service For 5/8 x 3/4 & 1 Meters v. Copper Tube Size (CTS) HPDE Only Performance Pipe Driscoplex 5100 Ultraline Centennial CenCore 5. Water Service Insert (HDPE Service Only) a. Use: Insert for connections on both ends of HDPE water service lines i. Stainless Steel A.Y. McDonald 6133T 6. Tapping Service Saddle a. Use: Tap for customer water service line i. Female Iron Pipe Thread (FIPT) ii. 200 psi working pressure iii. Sealed EPDM O-ring outlet iv. Brass or bronze body / flattened silicon bronze double straps (ACP/DIP ONLY) v. Brass or bronze body / 304L stainless steel double straps (C900 ONLY) ACP/DIP Only Mueller BR2B Jones J-979 Ford 202B d. Approved Products C-900 Only Mueller BR2S Jones J-969 Ford 202BSD 7. Ball Corporation Valves f. Use: Customer water service line shut off at water main g. Specifications i. Male Iron Pipe Thread (MIPT) for Service Saddle ii. Copper Tube Size (CTS) Compression Connection for new water services Page 4

Standard 863 3/4 & 1 Water Service For 5/8 x 3/4 & 1 Meters iii. Copper Tube Size (CTS) Pack Joint Connection for retrofit water services iv. 100 psi working pressure v. ANSI/AWWA C800 vi. Brass alloy body (ASTM B62) h. Approved Products Mueller B-25028 8. Angle Meter Ball Valves g. Use: Customer water service shut off on both sides of water meter h. Specifications i. Copper Tube Size (CTS) Compression Connection for water service ii. Female Iron Pipe Thread (FIPT) for house side connection iii. Meter swivel nut for meter connections iv. 100 psi working pressure v. ANSI/AWWA C800 vi. Brass alloy body (ASTM B62) i. Approved Products Street Side Mueller B-24258 Jones J-1963WSG a. Approved Products House Side Mueller B-24265 Jones J-1966W 9. Meter Boxes and Covers a. Use: Vault to access angle meter stops and customer meters i. High density reinforced concrete box ii. Non-settling shoulders iii. Reinforce concrete lid with Probe Hole (Non-Traffic Only) iv. Polypropylene face: ASTM D1693 v. Steel Checker Plate Cover, 6-inch round self-closing reading lid (Traffic Only) Boxes (3/4 Meter) Old Castle Precast B12Box (Christy) Page 5

Standard 863 3/4 & 1 Water Service For 5/8 x 3/4 & 1 Meters d. Approved Products Boxes (1 Meter) Old Castle Precast B16Box (Christy) e. Approved Products Lids (3/4 Meter) Old Castle Precast B12P / B12-61G (Traffic) f. Approved Products Lids (1 Meter) Old Castle Precast N16RP / B16-61G (Traffic) Page 6

Standard 864 1 Dual Meter Service 1. U Branch Connection a. Use: Yoke to split service at property line for 2 customer meters i. Copper Tube Size (CTS) Compression Connection for water service ii. Male Iron Pipe Thread (MIPT) for meter connection iii. Bronze / Brass Mueller H-15363 2. Angle Meter Ball Valves a. See Standard 863, House Side Page 7

Standard 883 Air And Vacuum / Air Release Valve 1. Air/Vacuum Relief Valve a. Use: Release air, break vacuum on water main line i. Solid cylindrical HDPE floats ii. Barrel: Stainless Steel AISI 304L iii. Top/Bottom Flange: Stainless Steel AISI 304 iv. National Pipe Thread (NPT) screwed inlet/outlet v. Minimum pressure rating: 276 psi Vent-o-mat RBX-1621 2. Angle Ball Valve Inlet to Air/Vacuum Relief Valve a. Use: Shut off for air/vacuum relief valve at utility vault i. Copper Tube Size (CTS) Compression Connection for water service ii. Female Iron Pipe Thread (FIPT) for air/vaccum valve iii. 100 psi working pressure iv. ANSI/AWWA C800 v. Brass alloy body (ASTM B62) Mueller B-24274 3. Tracing Wire Service a. See Engineering approved Standard 863 for details. 4. Tracing Wire Service Splice b. See Engineering approved Standard 863 for details. 5. Water Service Line a. See Engineering approved Standard 863 for details. 6. Water Service Insert (HDPE Service Only) b. See Engineering approved Standard 863 for details. 7. Ball Corporation Valves Mainline shutoff a. See Engineering approved Standard 863 for details. Page 8

ENGINEER S LIST OF APPROVED ITEMS SANITARY SEWER SYSTEM General 1. Advanced written approval from the City Engineer is required to use products. Page 9

Standard 500 Standard Precast Concrete Manhole For Sanitary Sewer 1. Cover and Frame a. Use: Secure access for sanitary sewer mainhole i. Ductile iron, ASTM A536 ii. Hinged Lid with Sanitary Sewer Badge iii. AASHTO H-20 load rated iv. Elastomeric seating gasket v. Slip resistant, ASTM C1028 vi. Hinge infiltration plug, closed pick holes CertainTeed Pamrex 2. Grade Rings a. Use: Adjust manhole frame to street grade i. Injection molded HDPE, ASTM D4976 ii. AASHTO H-20 load rated LadTech, Inc LadTech Adjusting Rings 3. Expanding Adhesive Sealant a. Use: Water sealant between cone/grade ring and grade ring/manhole frame i. Single component, closed cell, hydrophobic polyurethane ii. Water activated iii. Expanding foam to fill voids iv. Designed for sanitary sewer environment Seal Guard, Inc XSeal 4. Adhesive Tape Wrap a. Use: Water sealant for horizontal concrete and HDPE grade ring joints i. Pre-formed, cold-applied, self adhesive pipe wrap Page 10

Standard 500 Standard Precast Concrete Manhole For Sanitary Sewer ii. Elastomer and resin bonded to a woven highly puncture-resistant polymer iii. Adhesive impregnated with an integrated primer iv. Thickness: 50 mil ± 2 mils v. Conforms to ASTM C209 Tapecoat Chase Tapecoat M50 RC 5. Manhole Base, Barrel, and Cone Structure a. Use: Manhole structural components to access sanitary sewer system i. Reinforced precast concrete, ASTM C478 ii. Conforms to type V cement, ASTM C150 iii. Cast in pipe to manhole connectors iv. Match incoming pipe material v. Loading: AASHTO H-20, soil, groundwater. Old Castle Precast Jensen Precast Cook Concrete Products Pirahana Pipe 6. Manhole Interior Coating a. Use: Protective coating to reduce groundwater infiltration and corrosion i. Concrete coating for sanitary sewer environment XYPEX BASF XYPEX Concentrate Tegraproof 7. Pipe to Manhole Connectors a. Use: Connection for sanitary sewer pipe to manhole i. Flexible watertight connector, ASTM C923 ii. Integrally cast in manhole base or barrel, as applicable iii. Nitrile or equivalent if groundwater contamination Page 11

Standard 500 Standard Precast Concrete Manhole For Sanitary Sewer A-Lok Products A-Lok X-Cel Compression Connector 8. Manhole Joint Sealing Compound a. Use: Apply two continuous rings at manhole horizontal joints to seal for water i. Low permeability water sealant for horizontal joints ii. Conform to ASTM C990 iii. Designed for sanitary sewer environment iv. Pre-formed, cold applied, adhesive rope-like butyl rubber gasket Henry Company RU 106 RUBR-NEK LTM Hamilton Kent Kent Seal No. 2 9. Manhole Interior Patch Material a. Use: Repair interior, horizontal joints, interior lifting rings vi. Non-shrink vii. Non-metallic viii. Designed for sanitary sewer environment XYPEX Sika Corp Xypex patch and plug SIKA Set Mortar 10. Transition Couplings a. Use: Slip coupling to protect sewer pipe material transitions from differential settlement at manholes i. 304 Stainless steel hardware ii. Nitrile or equivalent if groundwater contamination iii. Designed for sanitary sewer environment Romac 501 Page 12

Standard 500 Standard Precast Concrete Manhole For Sanitary Sewer Page 13