Power Injectors for Diagnostic Imaging

Similar documents
Mitos P-Pump. product datasheet

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

TUBING LEADER IN FLUID MANAGEMENT

ORGANIC SAMPLE PREPARATION

Covering the Spectrum

DUAL PUMPS COMMUNICATIONS CABLE

EXACTAMIX Compounding. Systems for Specialty Pharmacies

Patient Information. PORT-A-CATH Implantable Venous Access Systems

Quick Start Guide. From setup to gameplay. Basic Setup. Configuring Your System. Using Game Discs IMPORTANT INFORMATION

A Practical Guide for the selection and use of prefilled Syringes for flushing vascular access devices. Paul Parisien, MedXL inc., Montreal, Canada.

QuickSpecs HP TFT7600 G2 KVM Console and Monitor (TFT7600 G2)

oj microline touch thermostats PRODUCT PROGRAMME intelligent thermostat design in three dimensions Floor Heating ELECTRIC Hvac CONTROLS & POWER

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Appendix L: Accessing/Deaccessing Implanted Central Venous Access Port

Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm

Data. microcat +SPECT

BLOOD COLLECTION MIXER

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Océ TCS500. No time to waste. Wide format colour. print, copy and scan. system

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Implanted Central Venous Access Devices (Ports)

PA 9117 FSAMP. Lilly. Prefilled Insulin Delivery Device User Manual

Baxter Elastomeric Pumps CLINICIAN GUIDE

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

SIGMA Spectrum Infusion System Compatible Baxter IV Sets

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

A small, safe, reliable and user-friendly device suitable for inpatient and outpatient use in a variety of applications

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Routefinder Testing and reporting for emergency lighting systems

Hardware Guide for the Classic and Elite CR Systems PN 9G9637 Version 1.0

QuickSpecs. HP IP Console Switch with Virtual Media Overview

Fixed and Adjustable Spacing Electronic Pipettes

QuickSpecs. Models HP Server Console Switches

S Y R I N G E P U M P S

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

TEDDINGTON. Intuitive control. TLC 700 The multifunctional controller

The intelligent DALI Emergency Lighting Monitoring System with One Click Commissioning

Helping to protect you from exposure to hazardous drugs

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

FT-100 Fire Training Fog Machine User Manual English

HomeLink. Take advantage of our service. Operating Instructions and. Programming g Guidelines. Hotline:

PLEUR EVAC CHEST DRAINAGE SYSTEMS. Great Innovations to Enhance Chest Drainage

CM921 - User Guide. Description. Features. 1 day Wireless Programmable Room Thermostat with LoT technology WHAT IS A PROGRAMMABLE ROOM THERMOSTAT?

HP Server Console Switch with Virtual Media Overview

How To Make A Fuel Manager Filter/Separator

OT 40L / 90L. Laboratory Steam Sterilizers

ArtisanLink Staining System is an automated special stains slide

How to design an insulin pump

Gallagher Vapour Recovery Monitoring

ELECTRIC CENTRAL HEATING FLOW BOILER

Patient Transport. with the Automated Impella Controller

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

GC-xt. The most flexible GC /GC-MS liquid sample injector

The Hemodialysis Machine Case Study

How To Use The Dc350 Document Camera

S300. Big Screen Viewing. Bright projection 2800 ANSI Lumens. SVGA resolution, 15,000:1 contrast ratio. Low ownership costs - up to 6500 hrs lamp life

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Design of an Insulin Pump. Purpose of an Insulin Pump:

Electric Forklift Trucks Capacity 5000 and 6000 lbs. RX60-25C and RX60-30C SERIES RX60

Hazards associated with the gas system and how to mitigate them

Excellence through Versatility

Mesenteric Angiography

Freka. Enteral Feeding Tube Product Range ENTERAL NUTRITION

How To Run A Factory I/O On A Microsoft Gpu 2.5 (Sdk) On A Computer Or Microsoft Powerbook 2.3 (Powerpoint) On An Android Computer Or Macbook 2 (Powerstation) On

User Guide. for Card Reader and Payment Application

Pogo> User Guide. for iphone, ipad and ipod touch

PE6108/PE6208/PE8108/PE8208

Promoting safer use of injectable medicines

SMART Collaboration Solutions A better way to work together

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

Regents of the University of Michigan 5/7/2015. Review pump functionality, sets and accessories Understand key process steps for

Nuance ecopy ShareScan. Brings paper documents into the digital world. Document capture & distribution Nuance ecopy

Product Description Sheet RB15 200D Gantry Robot Item No

ChromQuest 5.0 Chromatography Data System

Everybody has the right to

Disposable Insulin Delivery Device User Manual

Setup for WinPlus/picoPrompt automatic script transfer via a remote FTP site

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

Good practice for the preparation of injectable medicines in clinical areas

AMX MULTI-USER, MULTI-PLATFORM SWITCHING FOR REAL-TIME DATA CENTER AND TEST LAB ENVIRONMENTS

CDS 4000 Conference Discussion System

Cytotoxic and Biotherapies Credentialing Programme Module 6

Instructions for Use

Research RF Sputtering Packages

Intelligent laboratory management Delivered by cobas IT middleware

enter the smart house

// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

Designed for multi-injector endurance testing, the

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Servo/Hydraulic Press Brake. HG Series HG 5020, HG 8025, HG 1303, HG 1703 HG 1704, HG 2203, HG 2204

QuickSpecs. Models HP Server Console G2 Switch. HP Server Console Switch G2 with Virtual Media & CAC. Overview

GE Healthcare. Digital Services Broadband. (High Speed Internet Connection) QuickStart. Guide. For Diagnostic Imaging Equipment

Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING

Back-UPS Pro 1300/1500 Installation and Operation

Single-Use Flow-Through Cell ph FTC-SU-HP8

Transcription:

Power Injectors for Diagnostic Imaging Contrast under Control

A resource for all your contrast delivery needs Contrast under Control 2 1 3 Mallinckrodt provides contrast delivery systems for Computed Tomography (CT), Magnetic Resonance Imaging (MRI) and Angiography. Our range of injectors has been developed from a heritage of innovation and technology. Providing valuable assistance to contrast delivery, each injector features integrated technological advancements, all designed to enhance ease of set up, operation and procedural time efficiencies. 1 Computed Tomography 2 Magnetic Resonance Tomography 3 Angiography 1

Optivantage DH Dual Head Contrast Delivery System in CT The advanced dual head CT injector Dual Head Versatility Performs up to 6 phases of contrast, saline or Simultaneous. Faceplates for both pre-filled and empty syringes. Fully Programmable Powerhead Enables you to select and amend protocols whilst remaining at the patients side. Intuitive user interface. Step by step set up to help prevent air embolism. Patency Check Feature The Patency Check feature allows the operator to inject saline at the maximum protocol flow rate to confirm a patent fluid pathway to the patient prior to contrast injection. This is carried out at the patients side for better control. Timing Bolus Feature Perform a Timing Bolus injection of contrast medium followed by a saline flush to determine ideal scan delay for optimum image quality. Tilt Enable An injection cannot be started until the correct enabling sequence has been completed, including purging air and tilting the powerhead downward to avoid injection of air bubbles. Simultaneous Injection (optional) Delivery of dual injection of contrast media and saline. Optibolus Software (optional) Optibolus Bolus Shaping Software automatically optimises your injection protocol for dynamic scanning procedures. Consistently provides uniform contrast enhancement and can support improved image quality. 1 2

Mounting Options The Optivantage DH is available in pedestal or ceiling mounted configurations. Manual Flow Knob Calibrated for easy quarterturn priming, and colour coded for saline and contrast. Display Orientation With just the touch of a powerhead key, the display graphics flip 180 to provide proper orientation for easy reading. Intuitive User Interface Easy to use menu allows you to quickly change protocols, flow rates and injection volumes. Auto purge function. Quick and efficient auto-fill of empty syringes. Homing sequence of rams after injection. Built-In Heater Blanket Faceplate options for both pre-filled syringes and empty syringes are quick and easy to change. Pre-filled syringe faceplate has an integrated heater blanket to maintain contrast at ideal temperature in order to reduce viscosity. 3

Optistar Elite Dual Head Contrast Delivery System in MRI Designed for enhancing examination outcomes and confidence Patency Check Feature The Patency Check feature allows the operator to inject saline at the maximum protocol flow rate to confirm a patent fluid pathway to the patient prior to contrast injection. This is carried out at the patients side. Multiple Phase Programming As many as four phases can be programmed for each injection protocol. As many as 40 injection protocols can be stored in memory. Timing Bolus Feature Perform a Timing Bolus injection of contrast medium followed by a saline flush to determine ideal scan delay for optimum image quality. This feature allows the operator to inject a specified amount of contrast medium during a test scan to determine optimum transit time of the contrast medium to the region of interest thus helping to maximise the diagnostic information. Enable from console The injector can be enabled from either the control room at the remote console, or from the powerhead, which may increase the efficiency. Battery Free Operation The first AC powered injector for the MR suite. Eliminates time and cost associated with battery charging and replacement. 3T compatible/non-ferrous dual powerhead The powerhead, power control unit, and remote stand are designed for use in the MR suite. 4

Powerhead Keys Large keys on the powerhead ensure ease of use. The injector can be enabled, started and stopped directly from the powerhead. Check For Air Feature System will not enable until steps have been followed and the operator has confirmed that they have checked for air. Auto retract Rams are positioned to allow the insertion of full syringes by activating the auto retract function. Easy Drop-In Syringe Loading Results in faster procedures. Syringe filling can be performed in either the control room or the scan room. Powerhead is designed to accept empty syringes or pre-filled syringes. Variable Drip Mode Switch between injection and drip mode at any time, to help ensure IV line patency throughout the procedure. Adjustable flowrate, volume and interval. Display shows remaining time and volume available for drip mode. 5

CT 9000 ADV Single Head Contrast Delivery System in CT Simplicity for single head delivery Touchscreen New easy to read colour touchscreen. Requires only 3 simple key strokes to activate injection. Programme up to four phases with inject or scan delay features. Protocol manager to store and recall up to 12 user defined protocols. Syringes The system accommodates front loading 200 ml disposable syringes or pre-filled syringes. Powerhead The powerhead LED display provides a highly visible indication of remaining volume. The programmable Auto-Fill feature automatically moves the syringe to the selected volume. Technical specifications Flow Rate 0.1 to 9.9 ml/sec Pressure Limit 300 psi Syringe Sizes 200 ml empty syringes 50/75/100/125 ml high pressure prefilled syringes Syringe Heater (optional) 37 C nominal. Volume 1 ml to volume in syringe Number of Phases 4 Protocol Memory 12 protocols 6 OptiBolus Bolus Shaping Software ENHANCEMENT LEVEL (HU) Normal Injection TIME (s) OptiBolus Injection 1. Bae KT, Tran HQ, Heiken JP. Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method. Radiology. 2004;231:732 736. Optimal Enhancement Level OptiBolus TM software was designed to employ multiphasic injection, to expand the window of enhancement for contrast procedures. OptiBolus TM software optimizes the contrast media injection process through: Uniform Distribution Deliver contrast media at a controlled flow rate and volume, to help ensure uniform vascular enhancement of the pulmonary arterial system throughout the scan. This helps decrease the possibility of missing the bolus. Optimize the Utility of Contrast Volume Potentially reduce IV contrast agent volume. This can allow you to use contrast media more efficiently, while also improving visualization at the bolus peak. 1 Ease of Use Your existing protocol converts to an OptiBolus TM protocol at the touch of a button. Order Information: Optional OptiBolus Activation Key: # 844210

Angiomat Illumena Contrast Delivery System for Cardiology, Angiography and CT Reliable and functional performance Digital Powerhead Display The LED display automatically flips as the powerhead is rotated ensuring proper orientation for viewing. Indicates programmed protocol and volume remaining in the syringe. Fill Control Bar Allows easy, one finger operation. Variable speed control of ram for syringe filling, pull-back, or infusion. Syringes The latex free and transparent syringes provide a crystal clear view of the contrast medium. Compatible with pre-filled syringes. Air Detection Device The optional Air Detection and Warning System (ADAWS) detects empty syringes and air bolus. Touchscreen The pressure sensitive touchscreen display makes the injection setup direct and easy. Protocol manager to store and recall user defined protocols. Multimodality With just a touch of a button the injector switches between Angio and CT modes. 7

Optivantage DH Product Information Technical Specifications Flow Rate 0.1 10.0 ml/sec Pressure Limit 50 325 peak psi Syringe Sizes 200 ml empty syringes 50, 75, 100, 125 ml high pressure prefilled syringes Syringe Heater 37 C nominal Minimises the loss of heat from preheated contrast Volume 1 ml to volume in syringe Up to 200 ml Scan Delay 0 600 sec Inject Delay 0 600 sec Phase Delay 0 600 sec Number of Phases 6 Protocol Memory 40 Inject Results Last 24 injected protocols SI contrast % ratio 10% to 90% in 5% steps Delivery System Code Pedestal V8401 V8411 Disposables Code Description QTY Multipack 844021 Syringe - Multipack 200 ml (Dual Check Valve Y Tubing) 50 each 844020 Syringe - Multipack 200 ml (No Check Valve Y Tubing) 50 each 844015 Syringe - Multipack 200 ml (Dual Check Valve Y Tubing) 50 each 800099 CT9000 ADV - Multipack 200 ml (Coiled tubing) 50 each Dual Pack 844023 Syringes - Dualpack 200 ml (Dual Check Valve) 20 each 844022 Syringes - Dualpack 200 ml (No Check Valve) 20 each 844016 Syringe - Dualpack 200 ml (Dual Check Valve Y Tubing) 20 each Syringe and J-Straw only 800096 CT9000 ADV - Front load Syringe with Handi-Fil 50 each Y-connection tubing 844012 CT Y Tubing Dual Check Valves - 152 cm (60 ) 50 each 844011 CT Y Tubing Single Check Valve - 152 cm (60 ) 50 each 844010 CT Y Tubing No Check Valve - 152 cm (60 ) 50 each Y-connector only 810555 Extension Y Tubing Adapter - Dual Check Valves 50 each Extension tubing 601195 Coiled Extension Tubing - 152 cm (60 ) 50 each CTL150N Straight Extension Tubing 150 cm (60 ) 50 each Transfer Set Description Optivantage Dual Head CT Contrast Delivery System Optivantage Dual Head CT Contrast Delivery System with OEM interface V8431 Optivantage Dual Head CT Contrast Delivery System with Simultaneous Injection and OEM interface Ceiling Mount V8402 Optivantage Dual Head CT Contrast Delivery System V8412 V8432 Optivantage Dual Head CT Contrast Delivery System with OEM interface Optivantage Dual Head CT Contrast Delivery System with Simultaneous Injection and OEM interface 810551 Transfer Set 50 each CTF015N Automatic filling Tubing with Dripping Chamber 50 each 844021 844023 800096 810555 601195 810551 CTF015N Product availability and Summary of Product Characteristics may differ from one country to another. For your country s specific information, please contact your local Mallinckrodt Office or Representative. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. 2013 Mallinckrodt. All rights reserved.

Optistar ELITE Product Information Technical Specifications Delivery System Flow Rate 0.1 to 10 ml/sec Pressure Limit 60 ml syringe: 150 psi 10, 15, 20, 30 ml PFS: 200 psi Syringe Sizes 60 ml empty syringes 10, 15, 20, 30 ml PFS Volume A Side: Up to 60 ml 10, 15, 20, 30 ml PFS B Side: Up to 60 ml Scan Delay 0 60 sec Inject Delay 0 300 sec Number of Phases 6 Phase Delay 0 600 sec Protocol Memory 40 Inject Result Last 48 injected protocols MR Compatibility Up to 3 Tesla Scanner Power supply AC Powered. No battery Code Pedestal M5200 Disposables Code Description QTY Multipack Description Optistar ELITE MR Contrast Delivery System - Rolling Stand 801800 Optistar MR Syringe 60/60/90 Multipack Syringe with Spike 801801 Optistar MR Syringe Lateral Flow Needle 60 ml Y - Connection Tubing 801106 Y - Tubing - Single Check Valve 152 cm (60 ) 801107 Y - Tubing - Single Check Valve 229 cm (90 ) Y - Connection only 810555 Extension Y Tubing Adapter - Dual Check Valves 50 each 50 each 100 each 100 each 50 each Extension tubing 601195 Coiled Extension Tubing - 152 cm (60 ) 50 each 801800 801801 801107 Product availability and Summary of Product Characteristics may differ from one country to another. For your country s specific information, please contact your local Mallinckrodt Office or Representative. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. 2013 Mallinckrodt. All rights reserved.

Angiomat Illumena Product Information Technical Specifications Delivery System Flow Rate Angio Mode: 0.1 40.0 ml/s CT Mode: 0.1 10.0 ml/s Pressure Limit Angio Mode: 75 1200 psi CT Mode: 75 300 psi Syringe Sizes 150, 200 ml - empty syringes 50, 75, 100, 125 ml - PFS Syringe Heater 37 C nominal. Minimises the loss of heat from preheated contrast Inject Delay 0 300 sec X ray Delay 0 300 sec Scan Delay (CT Mode) 0 300 sec Rate Rise 0 10 sec Phase Delay 0 300 sec Number of Phases 1, 2 or 3 4 Protocol Memory Angio Modes: 45 protocols CT modes: 45 protocols Code Disposables Code Description QTY Syringe and J-straw Description Pedestal 7261 Illumena Contrast Delivery System with Rolling Pedestal 7261-S Illumena Contrast Delivery System with Rolling Pedestal - Siemens Interface Ceiling Mount 7272 Illumena Contrast Delivery System with Ceiling Suspension and Rack Mount 7272-S Illumena Contrast Delivery System Fixed Ceiling Suspension - Siemens Interface Table Mount 7267 Illumena Contrast Delivery System with Table Mount 7267-S Illumena Contrast Delivery System Fixed Table Mount Rack- Siemens Interface Faceplate (Optional) 900480 Illumena Faceplate Assembly - 125 ml (PFS) 900491 Illumena Faceplate Assembly with Air Detection System - 150 ml 900477 Illumena Faceplate Assembly - 200 ml Heater Blanket (Optional) 900430 Illumena Heater Blanket Assembly 900101 Syringe with handifil - quick connector 150 ml 50 each 900102 Syringe with handifil - quick connector 150 ml with 50 each Coiled Extension Tubing - 152 cm (60 ) 900103 Linden Luer Syringe with Handi-Fill 50 each Straw 150 ml 900104 Linden Luer Syringe with Handi-Fill Straw 50 each 150 ml with Coiled Extension Tubing - 152 cm (60 ) 900105 Syringe with Handi-Fill Straw - 200 ml 50 each Extension Tubing FLEX120N High Pressure Connection Line 120 cm 25 each FLEX120RAN High Pressure Connection Line with Rotating 25 each Adaptor 120 cm FLEX75RAN High Pressure Connection Line with Rotating 25 each Adaptor 75 cm HP120RAN Flexible high pressure tube with rotating Adapter 120 cm 25 each 900491 900103 FLEX75RAN HP120RAN Optional interfaces available. For referencies please contact your local Mallinckrodt Office or Representative. Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. 2013 Mallinckrodt. All rights reserved.

Product availability and Summary of Product Characteristics may differ from one country to another. For your country s specific information, please contact your local Mallinckrodt Office or Representative. For further information, please contact your local representative or UK Marketing for further information. Tel No: +44 1329 224159 Fax No: +44 1329 224324 Mallinckrodt, the M brand mark and the Mallinckrodt Pharmaceuticals logo are trademarks of a Mallinckrodt company. 2013 Mallinckrodt. All rights reserved. CM-POWERINJ/INT 11/2013 MALLINCKRODT PHARMACEUTICALS UK COMMERCIAL LTD 4500 Parkway, Whiteley, Fareham, Hampshire PO15 7NY