High Performance Facility Synchronization in Office Design



Similar documents
Perspectives on Workplace Sustainability

The Integrated Design Process

High-Performance Tenant Build-out: A Primer for Tenants

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

Building Energy Management: Using Data as a Tool

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

Energy Audits. Good energy management begins with an energy audit

Idaho Energy and Cost Savings

LEED GOLD CERTIFIED OFFICE DESIGN AND CONSTRUCTION

Operating Sustainable Facilities

Deep Energy Savings in Existing Buildings

Mississippi. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

Effect of Temperature on Task Performance in Offfice Environment

Tennessee. Energy and Cost Savings. for New Single and Multifamily Homes: 2009 and 2012 IECC as Compared to the 2006 IECC

Colorado Energy and Cost Savings

AIR DISTRIBUTION FOR COMFORT AND IAQ

Decision-making Methodology & Selection Tools for High-performance Window Systems in U.S. Climates Kerry L. Haglund 1

FEDERAL LEADERSHIP IN HIGH PERFORMANCE and SUSTAINABLE BUILDINGS MEMORANDUM OF UNDERSTANDING

BUILDING PERFORMANCE METRICS

Energy and Cost Savings

Indiana Energy and Cost Savings

Georgia Energy and Cost Savings

FINANCIAL EVALUATION OF ENERGY SAVING PROJECTS: BUILDING THE BUSINESS CASE

Indoor Environment Quality + Workplace Environment Health Sciences Building St. Cloud Technical and Community College St. Cloud, MN Report 1

REHUMANIZING THE FORMAL OPEN SPACE OFFICE DESIGN

HVAC. Combat rising energy costs

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Reducing Data Center Energy Consumption

HOW TO CONDUCT ENERGY SAVINGS ANALYSIS IN A FACILITY VALUE ENGINEERING STUDY

Implications IN THIS ISSUE. A Newsletter by InformeDesign. A Web site for design and human behavior research.

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Discretionary Capital Expenditures. Discretionary Capital Expenditure. Presented by Byron Smith, CCIM

The Empire State Building Repositioning an Icon as a Model of Energy Efficient Investment

Understanding Financial Management: A Practical Guide Guideline Answers to the Concept Check Questions

Los Angeles Mission College Facilities Master Plan Draft Program Environmental Impact Report 3.5 ENERGY CONSERVATION AND SUSTAINABILITY.

How To Calculate Cost Of An Eco-Friendly Building

Building Energy Modelling. prescriptive

Systems Selection Enclosure Systems Material Selection Assessment and Mitigation

The Economic Benefits of Oil and Natural Gas Production: An Analysis of Effects on the United States and Major Energy Producing States

Green Building Asset. Higher Asset Value? Research Snapshot. Energy efficient green. buildings have lower. energy bills and building

Adaptive strategies for office spaces in the UK climate

Executive Summary Environment/Behavior/Neuroscience Pre & Post- Occupancy Evaluation of New Offices for

Data Centers That Deliver Better Results. Bring Your Building Together

LIFECYCLE COSTING FOR DATA CENTERS: DETERMINING THE TRUE COSTS OF DATA CENTER COOLING

Flooring materials life-cycle costing for educational facilities

PROSPECTUS ALTERATION DENVER FEDERAL CENTER BUILDING 53 LAKEWOOD, CO

AN INTRODUCTION TO REAL ESTATE INVESTMENT ANALYSIS: A TOOL KIT REFERENCE FOR PRIVATE INVESTORS

Department Notes of Construction Management California State University, Chico

250 St Georges Tce, Perth, WA (QV1)

DIAGNOSING, BENCHMARKING AND TRANSFORMING THE LEED CERTIFIED FIU SIPA BUILDING INTO A NET-ZERO-ENERGY BUILDING (NET-ZEB)

Increasing Energ y Efficiency In Data Centers

Displacement Ventilation in Schools

Essam E. Khalil

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Lease-Versus-Buy. By Steven R. Price, CCIM

Fact Sheet. Better Buildings Initiative. Commercial Building Tax Credit March 4, 2011

ALWAYS ON GLOBALSWITCH.COM

UNDERFLOOR AIR DISTRIBUTION

Building Information Modelling (BIM); How it Improves Building Performance. R.P. Kumanayake Lecturer, Department of Civil Engineering

LEED PRESENTATION OUTLINE

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

T109 Architectural Technology MTCU Code Program Learning Outcomes

SUSTAINABLE BUILDINGS TO PLEASE YOUR CFO: Putting the Green into Green Buildings by Focusing on ROI

Mechanical Systems Proposal revised

Affordable Zero Energy

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

S. 3591, Commercial Building Modernization Act Reforms the 179D Tax Deduction for Energy Efficient Commercial and Multifamily Buildings

ENTREPRENEURIAL FINANCE: Strategy Valuation and Deal Structure

NUMBER EFFECTIVE DATE. July 23, 2003

Air Conditioning, Comfort and Energy in India s Commercial Building Sector

Za abeel Energy City Master Plan. Dubai, United Arab Emirates

BREEAM Refurbishment and Fit-out 2014 Briefings. Part of the BRE Trust

Data Center & IT Infrastructure Optimization. Trends & Best Practices. Mickey Iqbal - IBM Distinguished Engineer. IBM Global Technology Services

Tate s Wire & Cable Solution

Sustainable Office Design (SOD) is different than existing programs STEP 1: STEP 2: STEP 3: STEP 4:

Introduction to Energy Codes & Green Building Programs

THE HIGH PERFORMANCE PORTFOLIO: LEASING & ENERGY: ALLOCATIONS SUMMARY: IN DEPTH:

Reducing the Impact of Energy Costs on Business

Service integration comes of age

CTBUH Copyright. What every tenant wants. Chairman, Jones Lang LaSalle. Dan Probst

Simulation of hygroscopic materials in the HVAC system of an office building

DISTRIBUTED GENERATION AND ENERGY EFFICIENCY FOR ACHIEVING ENERGY SELF-SUSTAINING INDUSTRIAL AREAS

PENNSYLVANIA GREEN ENERGY LOAN FUND

BOMA BESt Assessment Overview

An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry

Smart Data Center Solutions

Linking Environmental Conditions to Productivity

FIRST RADIANT COOLED COMMERCIAL BUILDING IN INDIA CRITICAL ANALYSIS OF ENERGY, COMFORT AND COST

The Economic Impacts of Reducing. Natural Gas and Electricity Use in Ontario

Accessing finance. Developing a business case for your resource efficiency projects

Green House, Hungary

Energy Analysis and Design

PORT OF SEATTLE MEMORANDUM. COMMISSION AGENDA Item No. 6e ACTION ITEM Date of Meeting January 12, 2016

Content Specification Outlines Certified Management Accountant (CMA) Examinations

The Wholesale-Retail Rental Housing Split, Tax Forgiveness on Rollover and Implications for Tenants

Accessing finance. Developing a business case for your resource efficiency projects

Green proof of performance pays

Causes and Prevention of Symptom Complaints in Office Buildings: Distilling the Experience of Indoor Environment Quality Investigators

Transcription:

International Journal of Architecture, Engineering and Construction Vol 1, No 4, December 2012, 221-230 High Performance Facility Synchronization in Office Design Mousa T. Gargari 1,, Daniel Durbin 1, Eric Inglert 1, Mark Frey 2, Bruce Mirrielees 2, Akshat Saxena 1 1 School of Advanced Structures, College of Engineering and Applied Science, University of Cincinnati, Cincinnati, OH 45221, United States 2 Hixson Architecture Engineering Interiors, Cincinnati, OH 45202, United States Abstract: The architecture of office space has intuitively and profoundly evolved in response to organizational phenomena (i.e. vertical to horizontal management structures) and in response to processes (i.e. transactionbased to knowledge-based interactions). Architects have embraced new design processes such as integrated project delivery, new tools like building information modeling and new trends such as the sustainability movement. The architectural design process is still not responsive enough to clients enterprise needs. In simpler words, the present architectural design process is not streamlined to increase employees productivity, nor is it economical and sustainable enough in order to suit client s needs. This study proposes High Performance Facility Synchronization (HPFS) as a synergistic system approach to be applied to office design. This paper demonstrates that using HPFS optimizes the return on investment by logically allocating the improvements budget to a suite of design interventions. The conclusions are drawn by applying HPFS to the adaptive reuse of an existing midrise multi-tenant office facility for single tenant occupancy. Keywords: Office design, high performance office, efficiency, productivity DOI: 10.7492/IJAEC.2012.024 1 INTRODUCTION Researchers and design professionals have identified several parameters that, each one in its own way, can influence certain aspects of the office design with varying degrees of effectiveness. Thermal comfort (Lan et al. 2011); lighting (Juslén et al. 2007); indoor air quality (Pawel et al. 2000) and culture (Haynes 2008), have been the main parameters studied and all have been quantified as a single parameter. Others have proposed to combine two or more parameters in order to achieve a higher degree of efficiency. Parametric studies have been conducted on the impact of these on either first-cost, cost of operation, or performance and efficiency of employees. To this date a synchronized and holistic approach to the design of a high-performance facility has not yet been established. Mirrielees (2006) proposed that facilities (offices) should be considered as a system and conceptualized this as High Performance Facility Synchronization (HPFS). The HPFS concept can achieve both quantitative and qualitative improvements in performance that overcome the first-cost financial advantage of conventional office design; HPFS optimizes the return on investment by logically allocating the improvements budget to a suite of design interventions This study involves the application of the HPFS concept to the adaptive reuse of an existing midrise multitenant office facility for single tenant occupancy in order to quantitatively demonstrate the advantages of this new concept to the conventional office design procedure. 2 LITERATURE REVIEW 2.1 Effect of Single Parameter Thermal Comfort There have been numerous studies that attempt to define the relationship between thermal comfort and office productivity. Lan et al. (2011) state that thermal comfort was derived from the actual requirements of people and was influenced by their metabolic heat production, physical activity, clothing and the four environmental factors: air temperature, mean radiant temperature, air velocity and air humidity. Of these *Corresponding author. Email: mousa.gargari@uc.edu 221

factors, air temperature alone is the most commonly used parameter in the studies of thermal comfort. In an extensive literature review Frontczak and Wargocki (2011) concluded that creating a comfortable thermal environment was often considered to be the most important factor for achieving overall satisfaction with Indoor Environmental Quality (IEQ). Niemelä et al. (2002) conducted a case study of the effect of air temperature on productivity in two call centers and concluded that productivity decreased 5-7% when the air temperature exceeded 25 C. Seppanen et al. (2006) developed a quantitative relationship between work performance and temperature within, below and above the comfort zone. They also reported that field studies show a consistent decrease in performance of typical office work tasks when temperatures increase above 24-26 C. Lan et al. (2011) presented a quantitative measure of relative performance as a function of thermal sensation and concluded that optimal performance was achieved when test subjects felt slightly cool. Fang et al. (2004) examined the impact of both air temperature and humidity on the perceived air quality in an office environment and concluded that the perception of air freshness and acceptability improved greatly as temperature and humidity decreased. Lighting The positive productivity effects from lighting control may be considered from the view of daylight, task light and indirect ambient light. Juslén et al. (2007) studied the effect of a controllable task-lighting system that allowed people to select lighting levels and concluded that productivity was influenced positively. Lee and Guerin (2010) evaluated and compared the workspace quality of Leadership in Energy and Environmental Design (LEED) - certified buildings and employee s satisfaction with job performance in five office types. This study revealed that cubicles with partitions over five feet tall inhibited light quality. Boubekri et al. (1991) studied the effect of sunlight patches on the occupant s emotional response and satisfaction and found that sunlight penetration affected the feeling of relaxation when the observer was sitting sideways to the window, and researchers proposed a relaxation-sunlight algorithm (i.e. relaxation = 0.0076S 2 + 0.247S + 7.5, where S is the percentage of sunlit area to the total floor area). The cumulative effect of these three lighting strategies may result in synergistic lighting systems and afford the designer the greatest overall productivity improvements. Indoor Air Quality Indoor air quality (IAQ) is known to affect productivity in office spaces. Several studies have been conducted in an attempt to quantify the relationship between the performance of office work and IAQ. Pawel et al. (2000) estimated that productivity increased an average of 1.5% for every 10% decrease in the percentage of persons dissatisfied with the air quality. They further estimated that performance of office tasks increased by 1.9% for every two fold increase in the ventilation rate at constant pollution load or for every two fold decrease in pollution load at a constant ventilation rate. Wargocki and Djukanovic (2005) have conducted simulations of the potential revenue obtainable from investments in improved indoor air quality in an office building. Their life cycle cost analysis of several types of Heating Ventilation and Air Conditioning (HVAC) systems indicated that the benefits from improved indoor air quality are up to 60 times higher than the investments required to achieve the improved air quality. They further report that simple payback times of investments were generally less than two years. Frontczak and Wargocki (2011) stated that providing people with the possibility to control the indoor environment improves thermal and visual comfort and overall satisfaction with IEQ as well as satisfaction with indoor air quality. Culture Haynes (2008) developed a validated theoretical framework for the evaluation of office productivity, which includes components to represent both the physical and the behavioral environment. The study found that interaction was perceived to be the component that had the most positive effect on productivity while distraction was perceived to have the most negative effect. Haynes (2009) provided justification and rationalization to the appropriateness of a research strategy for measuring the impact of office environment on perceived productivity. It was stated that comfort, office layout, interaction and distraction were factors affecting productivity. Oldham (1988) reported that the primary environmental behavior theory used to explain the reduced office-worker concentration involved the concept of overstimulation that could result in behavioral withdrawal and dissatisfaction in occupants who did not have well-developed stimulus screening personality attributes (i.e. hierarchical versus immediate attention). The findings suggested that the combination of partitions with low-density planning had the most positive effect; optimal combination of social density, number of enclosures and interpersonal distance achieved the most harmonizing balance; and, lower densities provided more significant improvements than partitioning alone. A similar study done around the same time distinguished the effects of individual differences, task complexity, and privacy on satisfaction with an employee s work environment (Block and Stokes 1989). The study also analyzed the effects of private versus non-private work settings on performance and correlated them with 222

individual differences and task complexity. The author found that privacy in an office was directly related to employee performance and satisfaction, and people working on complex tasks get more distracted in nonprivate settings. Sundstrom et al. (1994) studied the effects of office noise on environment satisfaction, job satisfaction and job performance. The study found that people talking, telephone rings and increasing noise negatively affected employees. Evans and Johnson (2000) also discussed the effect of long-term exposure to low intensity office noise on performance and productivity, although in a different fashion. Evans studied the effects of low intensity noise on epinephrine, which is the most reliable neuroendocrine index of stress. The study found that long-term exposure to noise increased stress levels, decreased the motivation levels of a person and decreased their likelihood to make postural adjustments in their computer workstation. 2.2 Combined Effect of Two or More Parameters Parametric studies have been conducted on the impact of design choices (e.g. insulation of the envelope, window area, building orientation, thermal inertia and ventilation) on the energy consumption of office buildings. From the results of the parametric studies researchers tried to indicate what should be done in practice to help architects to design energy efficient buildings with a good thermal interior climate (Gratia and De Herde 2003). In the design of integrated building concepts it will be very beneficial to identify the most important design parameters in order to more efficiently develop alternative design proposals and/or reach optimized design solutions. This can be achieved by applying sensitivity analysis early in the design process (Heiselberg et al. 2009). Loftness et al. (2007) earlier had suggested that technical and mechanical control of the interior was not sufficient to improve IEQ and may be related to the integrated sum of three primary factors (e.g. sustainable design, impact of occupants and quality of interior finishes). The building investment decision support tool (BIDS) presented productivity improvements data from case studies in the following ranges: Highperformance ventilation strategies increase productivity from between 0.5% to 11%; Individual thermal control may account for up to 3% productivity gains; Improved lighting design may increase user productivity in a range from 1% to 23%; while, access to the natural environment may increase productivity from 0.5% to 18%. They concluded that a healthy interior air quality and environment is a function of sustainable design practices, individual occupant control and certification of consumer products and building materials. Pati et al. (2010) proposed that organizational goals (e.g. health, productivity, learning and satisfaction) are related to environmental design, and concluded that aligning the design and maintenance of building and subsystems with the social and economic organizational objectives improves performance measures. The primary finding was that the deliberate consideration of maintenance performance during the upfront design decision phase of a project assisted in meeting organizational objectives. Pennell (2009) suggested that clients seek added value, intelligent buildings, green design and sustainable materials in order to satisfy an integrated criteria set that includes comfort, security, productivity, flexibility, resilience, emissions and consumption. He concluded that facilities will benefit most from automation and networks. Pugsley and Haynes (2002) described how organizations (esp. government offices) leverage intellectual capital through team work and group office designs, and how information and communications technology (ICT) allows flexible work environments. Researchers theorized that the optimal design integrates the physical systems with the human systems of the organization. Shared facilities however resulted in suboptimal perceptions regarding resource supply as well as suboptimal perceptions regarding environmental conditions (e.g. privacy, screening, internal air quality, thermal and light control). Furthermore, users reported that noise levels were disruptive. These researchers concluded that a revised design should provide greater user control of thermal and light systems. A study conducted in Norway provided the following definitions with regard to the adaptability of office spaces. Adaptability is defined in terms of: generality, flexibility and elasticity. Generality is when the building adapts to changing functional user or owner needs without changing its properties. Flexibility is when the building adapts to changing functional user or owner needs by changing its properties easily. Elasticity is when the building adapts to be extended or partitioned related to changing user or owner needs. Owner-occupied buildings are more adaptable, as compared to buildings constructed by a group who develop them for renting and management. The least adaptable ones are those developed by a group who develop property for sale to investors. According to the author, when the property market is customer driven and the property owners and occupiers are informed then there is a demand for more adaptable office buildings (Arge 2005). The literature survey on the above mentioned parameters show that to this date a synchronized and holistic approach to the design of high-performance facility has not been established. Following is the process of application of HPFS concept to the adaptive reuse of an existing midrise office building for single tenant occupancy. This study con- 223

firms that using the HPFS concept can produce significant economic advantage to a client. 3 HPFS METHODOLOGY HPFS is a synchronized and holistic approach to the design of facilities. The integrated design of architectural systems may achieve qualitative as well as quantitative improvements, contributing future human performance and productivity dividends to a firm s finances. The objective of this study was to model and measure the HPFS framework and its effective return on architectural investment (ROAI). The methodology described in the HPFS flowchart defines a protocol for evaluating quantitative improvements and future productivity gains that may offset the first-cost financial advantage of conventional office design. The real estate pro forma is familiar to firms as a tool for valuing capital assets and also long-term leases (Geltner and Miller 2001). Discounted cash flow analysis (DCF) is a technique that estimates cash flows into the future and rolls back all of the cash flows resulting in a net present value (NPV). Any asset with an NPV less than zero is assumed to be a poor investment. Using a DCF tool, two dissimilar and complex cash flows may be compared side-by-side and evaluated on each asset s relative NPV merit. For the purposes of this study, we developed a three-step process with an objective of optimizing a suite of four HPFS systems. The first step involved the establishment of a baseline investment level. The assumptions were as follows: A single tenant would occupy the entire multi-story building for a lease period of ten years. Figure 1 is Figure 1. Four-story atrium lobby a photograph from the four-story atrium lobby amenity of the Executive Centre, a building of structural steel, precast concrete panels, and reflective insulating glass that is mechanically conditioned with a rooftop variable-air-volume system. The original construction date was 1986. The company was modeled from business census data from the region local to the subject building, Cincinnati, Ohio. The gross revenue per employee in a company with 500 employees was assumed to be $ 200,000. The average salary of an employee in a company of this size and $ 100 million in gross revenues was assumed to be $ 77,000. Figure 2 is a flow chart, which describes the HPFS process. A common multiplier firms use to cover the cost of revenue producing employees is 2.5. The authors rounded $ 193,000 (i.e., product of 77,000 and 2.5) to $ 200,000 gross revenues, in order to normalize the two assumptions. A common profit assumption for companies of this size in the service sector (i.e., real estate operations) was assumed to be 15%, and that yielded a net income (i.e., profit) per employee of $ 30,000. All profitability values and expenses were ultimately converted to a dollar-per-square-foot number for the pro forma. The baseline tenant improvement investment (i.e., control condition) was assumed at $ 34/ft2. The productivity multiplier for the baseline pro forma was set at a nominal 1.0. The remaining assumptions were as described in Table 1. The resultant NPV for the control condition (i.e., no changes) was set to a nominal value (i.e., $ 493 = 1.0) in order to compare the experimental ROAI to a baseline control value. The second step involved establishing a theoretical test for the productivity multiplier section. The implication here was that architecture was an asset that firms leveraged (e.g., through rent and building operations investments) in order to produce profit. This model isolated the productivity improvement effects of greater investment. The second pro forma used the minima (i.e., most conservative) values from the range that Loftness et al. (2007) proposed. Loftness et al. (2007) had no proposed value for cultural aspects, and for this study the multiplier was set to 1.01 as an illustration of the method. The analysis proposed that a doubling of the minimal improvements budget from $ 34/ft 2 to $ 68/ft 2 yielded a theoretical ROAI effect of 1.9 (i.e., $ 65/ft 2 of additional profit). This doubling was arbitrary; and, the purpose of the linear programming model proposed in step three was to solve for an optimized suite (i.e., set) of improvements. The third step provided a systematic way to optimize what was a multivariate objective assumed to be a linear function subject to constraints. For this we employed concepts from linear programming based on the simplex method - an iterative process that approaches an optimum solution (i.e., minimization of tenant improvement costs for HPFS). Every system outside of the theoretical optimum may be subjected to several 224

Table 1. DCF of standard tenant improvements (i.e., $ 34) Item 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 Income Net income $30,000 $31,200 $32,448 $33,746 $35,096 $36,500 $37,960 $39,478 $41,057 $42,699 per worker Net income $109 $113 $118 $122 $127 $132 $138 $143 $149 $155 Productivity multiplier Thermal comfort 1.0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Lighting 1.0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Air quality 1.0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Cultural 1.0 $0 $0 $0 $0 $0 $0 $0 $0 $0 $0 Total net income $109 $113 $118 $122 $127 $132 $138 $143 $149 $155 Operating expenses Rent 11.00 11.33 11.67 12.02 12.38 12.75 13.13 13.53 13.93 14.35 Churn 0.82 0.84 0.86 0.89 0.92 0.95 0.97 1.00 1.03 1.06 Utilities 8.00 8.24 8.49 8.74 9.00 9.27 9.55 9.84 10.13 10.44 Capital expenses Tenant improve- $34 ments Return on leasable asset Net cash flows -$34 $89 $93 $97 $101 $105 $109 $114 $119 $124 $129 Net present value $493 Notes: 1. Gross revenue per worker: $ 200000; 2. Cost of revenue less officing: $ 170000; 3. Revenue growth rate: 4%; 4. Employees: 500; 5. Leasable area: 138000ft 2 ; 6. Net profit margin before officing: 15%; 7. Annual churn rate: 45%; 8. Annual churn costs: 0.82$/ft 2 ; 9. Rent: 11$/ft 2 ; 10. Utilities: 8$/ft 2 ; 11. CPI expenses escalation: 3%; 12. NPV discount rate (ROA): 12%. forms of inefficiency. Our linear programming model considers one such form of inefficiency common to all real estate, load factor. This is a multiplier that accounts for the share of the common areas and is usually expressed as a percentage (i.e., assumed to be 11% in this study). Another inefficiency accounted for in the model is the inexact matching of system costs to the theoretical investment levels. As an example, thermal comfort may yield a 2% increase in productivity at an optimized investment level (i.e., $ 4/ft 2 ). The yield may vary somewhat at the actual investment level of $ 3.75, as an arbitrary cost described here for the sake of illustration. Figure 3 illustrates a web-based interface and form that allows a designer to input some project characteristics to test in the HPFS algorithm. Several of the form fields (i.e., gray-colored) depend on a calculated result from the proxy-optimized pro forma worksheet in Table 2. The web-based form provides a tool for the preparation of an objective and constraints statement for use in a simplex method tool (Waner 2010). In our study, we relied on the easy-to-use Finite mathematics utility: simplex method tool. The optimal solution provided a value for the second year (i.e., 2012) net cash flow per square foot, and the sum of the variable values given (e.g., x, y, z and w) provided a first year (i.e., 2011) tenant improvement per square foot. Entering these optimized values once more into the spreadsheet (i.e., Table 3) illustrated a persuasive analysis for the client that a designer can use to demonstrate an asset valuation (quantitative) approach that supports the owner s qualitative goals. The proxy value we used in Table 2 proposed a doubling of the tenant improvement budget ($ 68). The investment in HPFS at the proxy level implied a productivity yield of $ 65/ft 2 and a total value proposition of almost $ 9.0 million. We defined the ROAI as the ratio of the total value proposition (i.e., $ 65/ft 2 138,000ft 2 = $ 8.97 million) to the upgrade costs difference between HPFS and the standard tenant improvement budget (i.e., $ 34/ft 2 138,000ft 2 = $ 4.69 million). The proxy ROAI was calculated as 1.9 (i.e., 9.0/4.7). The investment in added value results in marginally higher first costs. Doubling a client s tenant improvement budget would likely be a difficult proposition for an architect to sell. The architect and client may agree there is an intuitive case for an HPFS investment. The authors sought to find an optimal mix, or suite of investments in productivity multiplying tenant improvements. The HPFS algorithm is a life-cycle costing methodology and is unique in addressing the productivity-multiplier effect. 4 OPTIMIZED RESULTS 4.1 The Optimization Model The authors have demonstrated the DCF approach to valuing investments in architectural improvements first by establishing the control condition of a $ 34/ft 2 tenant improvement with no consideration for the four HPFS investments in thermal, lighting, air quality and improved office planning (Table 1). An initial trial run of the DCF, which doubled the tenant improvement ($ 68/ft 2 ) and invested $ 34/ft 2 in HPFS interventions, yielded productivity dividends (Table 2). The authors hypothesized that applying a linear programming model may optimize the HPFS investment productivity yields. A linear objective function was designed to find a minimum value of investment subject 225

Table 2. DCF of proxy HPFS tenant improvements (i.e., 2 $ 34 = $ 68) Item 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 Income Net income $30,000 $31,200 $32,448 $33,746 $35,096 $36,500 $37,960 $39,478 $41,057 $42,699 per worker Net income $109 $113 $118 $122 $127 $132 $138 $143 $149 $155 Productivity multiplier Thermal comfort 1.02 $2 $2 $2 $2 $3 $3 $3 $3 $3 $3 Lighting 1.07 $8 $8 $8 $9 $9 $9 $10 $10 $10 $11 Air quality 1.05 $5 $6 $6 $6 $6 $7 $7 $7 $7 $8 Cultural 1.01 $1 $1 $1 $1 $1 $1 $1 $1 $1 $2 Total net income $125 $130 $135 $141 $146 $152 $158 $164 $171 $178 Operating expenses Rent 11.00 11.33 11.67 12.02 12.38 12.75 13.13 13.53 13.93 14.35 Churn 0.82 0.84 0.86 0.89 0.92 0.95 0.97 1.00 1.03 1.06 Utilities 8.00 8.24 8.49 8.74 9.00 9.27 9.55 9.84 10.13 10.44 Capital expenses Thermal interven- $17 Lighting interven- $8 Air quality $5 interven Cultural interven- $4 Tenant improve- $68 ments Return on leasable asset Net cash flows -$68 $105 $110 $114 $119 $124 $129 $135 $140 $146 $152 Net present value $558 Notes: 1. Gross revenue per worker: $ 200000; 2. Cost of revenue less officing: $ 170000; 3. Revenue growth rate: 4%; 4. Employees: 500; 5. Leasable area: 138000ft 2 ; 6. Net profit margin before officing: 15%; 7. Annual churn rate: 45%; 8. Annual churn costs: 0.82$/ft 2 ; 9. Rent: 11$/ft 2 ; 10. Utilities: 8$/ft 2 ; 11. CPI expenses escalation: 3%; 12. NPV discount rate (ROA): 12%. Table 3. DCF of experimental HPFS tenant improvements (i.e., linear program optimal = $ 50.20) Item 2011 2012 2013 2014 2015 2016 2017 2018 2019 2020 2021 Income Net income $30,000 $31,200 $32,448 $33,746 $35,096 $36,500 $37,960 $39,478 $41,057 $42,699 per worker Net income $109 $113 $118 $122 $127 $132 $138 $143 $149 $155 Productivity multiplier Thermal comfort 1.02 $2 $2 $2 $2 $3 $3 $3 $3 $3 $3 Lighting 1.07 $8 $8 $8 $9 $9 $9 $10 $10 $10 $11 Air quality 1.05 $5 $6 $6 $6 $6 $7 $7 $7 $ 7 $8 Cultural 1.01 $ 1 $1 $1 $1 $1 $1 $1 $1 $1 $2 Total net income $125 $130 $135 $141 $146 $152 $158 $164 $171 $178 Operating expenses Rent 11.00 11.33 11.67 12.02 12.38 12.75 13.13 13.53 13.93 14.35 Churn 0.82 0.84 0.86 0.89 0.92 0.95 0.97 1.00 1.03 1.06 Utilities 8.00 8.24 8.49 8.74 9.00 9.27 9.55 9.84 10.13 10.44 Capital expenses Thermal interven- $10 Lighting interven- $4.2 Air quality $1 interven Cultural interven- $1 Tenant improve- $50.2 ments Return on leasable asset Net cash flows -$50.2 $105 $110 $114 $119 $124 $129 $135 $140 $146 $152 Net present value $574 Notes: 1. Gross revenue per worker: $ 200000; 2. Cost of revenue less officing: $ 170000; 3. Revenue growth rate: 4%; 4. Employees: 500; 5. Leasable area: 138000ft 2 ; 6. Net profit margin before officing: 15%; 7. Annual churn rate: 45%; 8. Annual churn costs: 0.82$/ft 2 ; 9. Rent: 11$/ft 2 ; 10. Utilities: 8$/ft 2 ; 11. CPI expenses escalation: 3%; 12. NPV discount rate (ROA): 12%. 226

Figure 2. HPFS process flow chart to a set of linear constraints. The most common process for solving linear programs is known as the Simplex Method, and the authors used a web-based tool available from Zweig media (Waner 2010). Once an optimal value of the objective statement was derived, then the investment mix of values were input as an experimental run of the DCF that allowed us to project the improved productivity dividends (see Table 3). The following subsection describes how we derived the objective statement for the model. 4.2 The HPFS Objective Statement In the optimized example the client was assumed to have a budget of up to $ 20/ft 2 to spend on HPFS over the standard tenant improvement allowance of $ 34/ft 2 (i.e., variable t ). The selected HPFS suite was as follows: thermal intervention - under floor airway distribution system (i.e., variable x ); lighting intervention - indirect pendant interior lighting (i.e., variable y ); air quality intervention - increased outside air with enhanced filtration system (i.e., variable z ); and, lower density open-office planning (i.e., variable w ). The objective for the client would therefore be to minimize the expense of incremental construc, p, for the leased asset that yielded future productivity gains for employees. The objective statement designed for the linear program with constraints was: Minimize p = x + y + z + w + t s.t. 1.94x + 6.79y + 4.85z + 0.97w 54 x + y + z + w 20 x 10 y 1 z 1 w 1 t 34 (1) 227

Figure 3. HPFS project data entry form The multivariate constraints for the objective statement were described as follows: 1. The first constraint was the sum of all productivity yields applied to the net income expressed in units of $/ft 2. Each productivity yield was limited by the load factor (i.e., 11%). As an example, the thermal coefficient of 1.94x was calculated as the product of the thermal productivity yield (0.02) the net income/ft 2 ($ 109) and the load factor (0.89). The inference was that a 2% assumed gain in productivity due to an HPFS thermal intervention would yield a $ 1.94/ft 2 productivity dividend. The same process was used for lighting (6.79), air quality (4.85) and cultural (0.97). The sum of the productivity yields was set to a threshold value of $ 54 (total budget) and implied an optimal combination calculated 228

as the sum of the standard tenant improvement costs ($ 34) and the budgeted incremental costs for the construction ($ 20). 2. The second constraint served to limit the total budget for the four interventions to the incremental investment in HPFS ($ 20). 3. The third constraint was based on an assumption about the experience-based logical mix of tenant improvements. The value of the thermal interventions was assumed to make up at least one-half ($ 10) of the total budget. 4. The fourth, fifth and sixth constraints were the next three HPFS variables, which ensured a minimum investment of at least $ 1/ft 2. 5. The last constraint was to ensure that the standard tenant improvement costs ($ 34) were maintained independent of the optimization for the original purpose of finishes, patch and repair costs. 4.3 The Optimized Results The model is robust and scalable, because the constraints can be fine-tuned for each specific project. As an example, as budgets vary so too might the HPFS mix and the designer could simulate a change in the expense ratios for each intervention. The results for the current optimized investment were as follows: p = 50.2, x = 10, y = 4.2, z = 1, w = 1, t = 34 Table 3 demonstrates the optimization effect of the investment (ROAI) in the discounted cash flow pro forma. The optimal value we used in Table 3 was a calculated total budget of $ 50.2/ft 2. The investment in HPFS at the optimal level implied a productivity yield of $ 81/ft 2 and a total value proposition of almost $ 11.15 million. Table 4 provides a ratio analysis of the discounted cash flow comparisons. We calculated the ROAI as the ratio of the total value proposition to the upgrade costs difference between the optimal HPFS and the standard tenant improvement budget (i.e., $ 16.2/ft 2 138,000ft 2 = $ 2.24 million). The proxy ROAI was calculated as 5.0 (i.e., 11.15/2.24). The Table 4. Ratio analysis of the discounted cash flow comparisons Analysis Value NPV1-NPV0 (Table 2: 2.0 $34 = $ 68) 65 Total value proposition 1 $8,954,153 Tenant improvement (TI) upgrade costs difference $4,692,000 Assumed return on base TI (i.e., no upgrades) 1.0 Calculated return on upgrade investment (ROAI) 2 1.9 NPV2-NPV0 (Table 3: Optimized = $50.2) $81 Total value proposition 1 $11,147,368 Tenant improvement (TI) upgrade costs difference $2,235,600 Linear program optimization value ROAI 5.0 Notes: 1. Product of the NPV difference ($/ft 2 ) and total project area; 2. Ratio of the total value proposition to the upgrade costs difference. optimization algorithm allowed for an ROAI increase of almost 163% and an improvement of approximately $ 2.19 million in the total value proposition. 5 CONCLUSIONS This study examined a design technique described by Mirrielees (2006), who proposed that facilities (offices) should be considered as a system and conceptualized this approach as HPFS. In the current study, this design technique was applied to the adaptive reuse of an existing 138,000-ft2 mid-rise, multi-tenant office facility for single tenant occupancy. Business census data from the Cincinnati, Ohio region was used to model a company with 500 employees producing an assumed annual gross income of $ 200 thousand per employee. A discounted cash flow analysis was used to evaluate three different design scenarios with all relevant values expressed as $ /ft 2 of leasable space. The first of these assumed that the building owner provided a minimal tenant improvement incentive set at $ 34/ft 2. This established the baseline needed to compare alternative design approaches. A linear program model was then constructed to account for a suite of design interventions aimed at improving; 1) thermal comfort 2) lighting 3) indoor air quality and 4) cultural aspects within the workplace. Using minimal productivity improvements from an earlier study by Loftness et al. (2007) for the first three factors and an assumed value for the cultural aspects factor, the linear model was used to analyze a second design scenario which assumed an arbitrary doubling of the tenant improvement incentive to $ 68/ft 2 with the additional $ 34/ft 2 spread across the 4 factors known to affect productivity. In the third scenario, an optimized mixture of design improvements was selected using the HPFS technique. In this case the expenditures for the four design improvements were optimized within a set of defined constraints. Each of the three design scenarios was subjected to a 10 year, discounted cash flow analysis to determine the NPV of the tenant improvement investments. The baseline case was found to have an NPV of $ 493/ft 2, while the second scenario had an NPV of $ 558/ft 2. The third scenario, which included the optimized HPFS design technique, had a tenant improvement incentive of $ 50.2/ft 2 and an NPV of $ 574/ft 2. These values were then extended over the leasable floor area of the facility to determine the incremental cash flow realized from the additional tenant improvement investment. The analysis shows that a doubling of the tenant improvement investment without regard to HPFS produced a ROAI of 1.9 times the baseline. Application of HPFS in an optimized fashion to the adaptive reuse of this existing office facility produced an ROAI of 5.0 (i.e., each additional dollar invested in the design improvements provided a $ 5 return). This study has shown that application of the 229

HPFS technique to the design of office space can provide significant economic benefit to a client. While the current study was limited to the adaptive reuse of an existing mid-rise office facility, the authors believe that the technique presented here can be applied to the design of virtually all office facilities. REFERENCES Arge, K. (2005). Adaptable office buildings: Theory and practice. Facilities, 23(3-4), 119 127. Block, L. K. and Stokes, G. S. (1989). Performance and satisfaction in private versus nonprivate work settings. Environment and Behavior, 21(3), 277 297. Boubekri, M., Hull, R. B., and Boyer, L. L. (1991). Impact of window size and sunlight penetration in office workers mood and satisfaction. Environment and Behavior, 23(4), 474 493. Evans, G. W. and Johnson, D. (2000). Stress and open-office noise. Journal of Applied Psychology, 85(5), 779 783. Fang, L., Wyon, D. P., Clausen, G., and Fanger, P. O. (2004). Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance. Indoor Air, 14(Supplement s7), 74 81. Frontczak, M. and Wargocki, P. (2011). Literature survey on how different factors influence human comfort in indoor environments. Building and Environment, 46(4), 922 937. Geltner, D. and Miller, N. (2001). Commercial Real Estate Analysis and Investments. South-western Publishing, Mason, Ohio, United States. Gratia, E. and De Herde, A. (2003). Design of low energy office buildings. Energy and Buildings, 35(5), 473 491. Haynes, B. P. (2008). An evaluation of the impact of the office environment on productivity. Facilities, 26(5-6), 178 195. Haynes, B. P. (2009). Research design for the measurement of perceived office productivity. Intelligent Buildings International, 1(3), 169 183. Heiselberg, P., Brohus, H., Hesselholt, A., Rasmussen, H., Seinre, E., and Thomas, S. (2009). Application of sensitivity analysis in design of sustainable buildings. Renewable Energy, 34(9), 2030 2036. Juslén, H., Wouters, M., and Tenner, A. (2007). The influence of controllable task-lighting on productivity: A field study in a factory. Applied Ergonomics, 38(1), 39 44. Lan, L., Wargocki, P., and Lian, Z. (2011). Quantitative measurement of productivity loss due to thermal discomfort. Energy and Buildings, 43(5), 1057 1062. Lee, Y. S. and Guerin, D. A. (2010). Indoor environmental quality differences between office types in LEED-certified buildings in the US. Building and Environment, 45(5), 1104 1112. Loftness, V., Hakkinen, B., Adan, O., and Nevalainen, A. (2007). Elements that contribute to healthy building design. Environmental Health Perspectives, 115(6), 965 970. Mirrielees, B. F. (2006). High performance facility synchronization. Journal of Facilities Management, 4(3), 192 202. Niemelä, R., Hannula, M., Rautio, S., Reijula, K., and Railio, J. (2002). The effect of air temperature on labour productivity in call centres - A case study. Energy and Buildings, 34(8), 759 764. Oldham, G. R. (1988). Effects of changes in workspace partitions and spatial density on employee reactions: A quasi-experiment. Journal of Applied Psychology, 73(2), 253 258. Pati, D., Park, C.-S., and Augenbroe, G. (2010). Facility maintenance performance perspective to target strategic organizational objectives. Journal of Performance of Constructed Facilities, 24(2), 180 187. Pawel, W., Wyon, D. P., and Fanger, P. O. (2000). Productivity is affected by the air quality in offices. Proceedings of Healthy Buildings, Espoo, Finland, 635 640. Pennell, N. (2009). If you ask me. Engineering and Technology, 4(16), 14. Pugsley, D. and Haynes, B. (2002). An alternative use of space in government office accommodation. Facilities, 20(1-2), 34 40. Seppanen, O., Fisk, W. J., and Lei, Q. H. (2006). Room Temperature and Productivity in Office Work. Lawrence Berkeley National Laboratory, Berkeley, California, United States. Sundstrom, E., Town, J. P., Rice, R. W., Osborn, D. P., and Brill, M. (1994). Office noise, satisfaction, and performance. Environment and Behavior, 26(2), 195 222. Waner, S. (2010). Simplex Method Tool. Available at <http://www.zweigmedia.com/realworld/simp lex.html>. Wargocki, P. and Djukanovic, R. (2005). Simulations of the potential revenue from investment in improved indoor air quality in an office building. ASHRAE Transactions, 111(2), 699 711. 230