Adsorption WATER TREATMENT

Similar documents
GRANULAR ACTIVATED CARBON FOR WATER & WASTEWATER TREATMENT

q = 6.74x1 = mg/l x 3.78x10 L/d = 3.4x10 mg / day a) Single CMFR mg/g C Organic Load = Carbon requirement = 6.74 mg 1000 g C inf = 10 mg/l

Trichloramine and Asthma in Swimming pools & spas Problem solved

Enhanced Organic Precursor Removals Using Aged Filter Media Page 1. Enhanced Organic Precursor Removals Using Aged Filter Media

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

How To Remove Iron From Water

WASTEWATER TREATMENT OBJECTIVES

Bromate Formation and its Control in Advanced Water Treatment System 高 度 浄 水 処 理 における 臭 素 酸 の 生 成 と 制 御

Iron and Manganese BACTERIA AND IRON AND MANGANESE

Water Treatment & Purification Chemicals

HUBER Vacuum Rotation Membrane VRM Bioreactor

Removal of Sulfate from Waste Water by Activated Carbon. Mohammed Sadeq Salman Computer Centre/ University of Baghdad

Removing Heavy Metals from Wastewater

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

Chemistry at Work. How Chemistry is used in the Water Service

REMOVAL OF PHOSPHATE FROM WASTEWATER USING LOW-COST ADSORBENTS

Residual Chlorine Decay Simulation in Water Distribution System

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

IB Chemistry. DP Chemistry Review

Fluids and Solids: Fundamentals

John D. Dyson, Manager Municipal Water Group Infilco Degremont Inc. Richmond, VA

Applying Life Cycle Assessment to Drinking Water Treatment

Water Purification Treatment System

SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

Experimental Study On The Replacement Of Sand Filters By Granular Activated Carbon Filters At La Presa (Valencia) Water Works

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Wastewater Reuse. Typical treated wastewater is:

ETC -SV. Class 0 oil-free compressed air through catalysis

Coagulation and Flocculation


Feasibility study of crystallization process for water softening in a pellet reactor

Ion Exchange Softening

Facility Classification Standards

Oasis Clearwater ENVIRONMENTAL SYSTEMS WASTEWATER TREATMENT ENGINEERS

WASTE WATER TREATMENT SYSTEM (OPERATING MANUALS )

Iranian J Env Health Sci Eng, 2004, Vol.1, No.2, pp Application of Intelligent System for Water Treatment Plant Operation.

DRAFT July, 2006 Page 1 of 18

Chapter 13 Properties of liquids

Rehabilitation of Wastewater Treatment Plant of Sakhnin City in Israel by Using Advanced Technologies

HEAT UNIT 1.1 KINETIC THEORY OF GASES Introduction Postulates of Kinetic Theory of Gases

Iron and manganese are two similar elements

DOWEX Resins as Organic Solvent Desiccants

DRINKING WATER - LAB EXPERIMENTS. Coagulation and flocculation LAB EXPERIMENTS. Jartest

SYNERGISTIC APPLICATION OF ADVANCED PRIMARY AND SECONDARY WASTEWATER TREATMENT SYSTEMS

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Chem 112 Intermolecular Forces Chang From the book (10, 12, 14, 16, 18, 20,84,92,94,102,104, 108, 112, 114, 118 and 134)

Water Treatment. Session Objectives

Water Purification Treatment. General Information. Water Purification Treatment Business of the Teijin Group. Water. Purification Treatment

Homeowners and Home Buyers Guide to Wells and Private Sewage Systems

Chapter 13 - Solutions

ION EXCHANGE RESINS INTRODUCTION

Module 16: The Activated Sludge Process - Part II Instructor Guide Answer Key

Part B 2. Allow a total of 15 credits for this part. The student must answer all questions in this part.

CERTIFICATION TO OPERATE WATER AND WASTEWATER TREATMENT SYSTEMS APPLICATION INSTRUCTIONS

Description of the Water Conserv II Facility

Complete. Water Solutions. for Rural India

WATER TREATMENT IN AUCKLAND

Wastewater Nutrient Removal

ABC & C 2 EP Formula/Conversion Table for Water Treatment, Distribution, & Laboratory Exams

for Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling

Cyanotoxin Removal in Drinking. Recreational Waters. Judy Westrick April 14, Northeast Regional Cyanobacteria Workshop

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Bioremediation of Petroleum Hydrocarbons and Chlorinated Volatile Organic Compounds with Oxygen and Propane Gas infusion

Municipal Standard Solutions. Water Treatment WATER TECHNOLOGIES

Water Water Treatment Plant Tour

Water Pollution. A Presentation for Café Scientifique Cherie L. Geiger, Ph.D. Department of Chemistry, UCF

8 Chemicals from water treatment and distribution

Innovation and Progress in Water Treatment Technology

A. Types of Mixtures:

Cambridge Wastewater Treatment Facility

EPB 311- Strategies for Dealing with Groundwater Treatment Systems Having High Natural Ammonia

CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Water Treatment NOTES. Cornell Cooperative Extension, College of Human Ecology. Iron and Manganese in Household Drinking Water

Exam 4 Practice Problems false false

1.85 WATER AND WASTEWATER TREATMENT ENGINEERING FINAL EXAM DECEMBER 20, 2005

Experiment (13): Flow channel

Hydraulics Laboratory Experiment Report

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Calcite PH Nutralizer System

Royal Caribbean International Advanced Wastewater Purification Systems

Appendix F Use of spill basin to further reduce final effluent variability - report

Coimisiún na Scrúduithe Stáit State Examinations Commission

Engineers Edge, LLC PDH & Professional Training

GUIDELINES FOR LEACHATE CONTROL

How To Water System

EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

Practice Tests Answer Keys

Basics of UV Disinfection

For Water to Move a driving force is needed

WATER TREATMENT SIMULATORS: STATE-OF-THE- ART REVIEW

Production of R-134a

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Transcription:

WATER TREATMENT WATER TREATMENT Adsorption micro pores pump macro pores meso pores 2 micro pores atrazine (mg/l) 1.5 1 > 25 nm 1-25 nm < 1 nm pesticides macro pore meso pore pump.5 1, 2, 3, bed volumes (m 3 /m 3 ) influent effluent

adsorption water treatment Framework This module explains adsorption. Contents This module has the following contents: 1. Introduction 2. Theory 2.1 Equilibrium 2.2 Kinetics 2.3 Mass balance 2.4 Solutions for the basic equations 3. Practice 3.1 Pseudo-moving-bed filtration 3.2 Pressure filtration 3.3 Powdered activated carbon 14

water treatment adsorption 1 Introduction Water contains dissolved organic matter that cannot be removed with floc formation, floc removal or sand filtration. These dissolved organic compounds are: - odor-, taste- and color-producing compounds - organic micropollutants (pesticides, hydrocarbon compounds) Activated carbon adsorbs (part of) the organic matter and is mainly used to treat drinking water produced from surface water. In the past, drin ing rinking water produced from surface water would pass through the following steps: floc formation, floc removal (sedimentation and filtration) and disinfection with chlorine. This was sufficient to comply with the drinking water guidelines for turbidity, odor, taste and hygienic reliability. In 1987 Amsterdam Water Supply discovered the presence of pesticides (Bentazon) in drinking water. Due to this discovery, the traditional treatment of surface water was no longer satisfactory and an extension with activated carbon was required. In addition, chlorine can react with organic matter (precursor), and trihalomethanes (THMs) can be formed. These THMs are toxic. To reduce the concentration, the formed THMs can be removed with activated carbon. The problem, however, is that carbon is rapidly saturated with THMs and has to be regenerated frequently. It is preferable to prevent the THMs from being formed. This can be done by reducing the concentration of the precursor before adding chlorine. Precursors cannot be measured directly, but the concentration of organic matter, expressed as TOC or DOC, is an indication. The best way to prevent THM formation is to avoid the dosing of chlorine, but this requires another treatment setup. Activated carbon is a substance with a high carbon concentration (e.g., pit-coal, turf). The activated carbon filters of the drinking water production plant at Kralingen have the objective to improve the taste of the water, to reduce the regrowth of bacteria in the piped network, and to remove toxic substances from the water. The carbon filters are placed after the floc formation, sedimentation and rapid sand filtration to avoid rapid clogging. The installation is based on pressure filters, so the construction height can be limited and only an extra pumping phase (middle pressure) is needed. The installation has the following characteristics: Filter bed height: 4 m Filtration surface area: 28 m 2 Number of filters: 12 Contact time (EBCT): 12 min Type of carbon: Norit ROW.95 Regeneration frequency: 1.5 year Under high temperatures this material becomes carbonated, meaning that the carbon partly transforms into carbon monoxide and water. This is how the carbon gets its open structure (Figure 1). The internal surface area of the activated carbon is several times larger than the external surface area. macro pores meso pores micro pores micro pores > 25 nm 1-25 nm < 1 nm macro pore pesticides meso pore Figure 1 - The open structure of activated carbon 15

adsorption water treatment Hence, a majority of the adsorbed substances is adsorbed inside the carbon. The dissolved organic matter can be removed from the water by filtration through a bed of activated carbon. Organic matter diffuses from the water phase to the surface of the carbon grains. The organic compounds are further transported into the carbon to be attached in the pores. The adsorption of organic matter is not finite. There is equilibrium between the concentration of dissolved compounds in water and the quantity of substances that are adsorbed onto the carbon. When different kinds of organic compounds are present in the water, competition will occur. Compounds that have been well-adsorbed will occupy adsorption places that cannot be used by compounds that are less adsorbable. Large organic molecules can also block micro pores, thus preventing the smaller organic molecules from entering these micro pores. After some time the activated carbon is saturated with adsorbed organic matter and the carbon needs to be cleaned. This is done by removing the carbon from the installation and heating it to 1 o C. This regeneration process has to be carried out once every couple of years. Activated carbon filters operate in the same way as rapid sand filters. Mostly downward flow, open filters are applied to prevent fine carbon grains from washing out (Figure 2). Since the contact time is the most important parameter for good removal, the filter is often designed with high beds to reduce the construction surface reservoir floc formation floc removal ozonation rapid filtration activated carbon filtration clear water reservoir Fe(III) reservoir: - storage - leveling off - auto purification ozonation: - desinfection - oxidation of organic matter dosage = 2-3,5 mg/l O3 activated carbon filtration: - removal of organic matter - removal of pesticides Cl 2 /ClO 2 Chlorine dosage for transport =.3 mg/l Figure 3 - Treatment process at Kralingen (Evides) area. Therefore, activated carbon filters cannot be operated under gravity, making an extra pumping phase necessary. After passing the filter bed, the water reaches the bottom construction of the filter and is then collected and transported to the clear water tank or the next treatment step. When the filter is clogged with suspended matter or biomass and the resistance is high, the filter bed is backwashed. The backwash water is drained by troughs that are placed above the filters. Clogging of the filter by suspended matter can lead to a higher regeneration frequency. Therefore, activated carbon filters are usually placed after floc formation, floc removal and rapid sand filtration (Figure 3). A cross-section A-A A Figure 2 - Longitudinal and cross-section of an activated carbon filtration installation Figure 4 - Activated carbon filtration at Andijk (treatment of surface water) 16

water treatment adsorption After activated carbon filtration, disinfection takes place to prevent biological growth in the piped network. This process can consist of slow sand filtration, UV-disinfection or dosing chlorine or chlorine dioxide. q (mg/kg) 35 3 25 2 15 2 Theory 2.1 Equilibrium Similar to aeration, equilibrium is established dur- ing adsorption. The maximum loading (loading capacity q max ) depends on the concentration of adsorbable matter in the bulk liquid (water). The higher this concentration, the higher the loading capacity is. The relationship between the loading capacity and the concentration of adsorbable matter in the bulk liquid is called the adsorption-isotherm. The best known is the Freundlich isotherm: q max x = = K c m n s in which: q max = loading capacity (g/kg) c s = equilibrium concentration (g/m 3 ) x = adsorbed amount of compound (g) m = mass of activated carbon (kg) K = Freundlich constant ((g/kg). (m 3 /g)n) n = Freundlich constant (-) The Freundlich constants K and n are influenced by water temperature, ph, type of carbon and the concentration of other organic compounds. Using laboratory experiments the Freundlich constants can be determined for a single substance with a specific type of activated carbon. In Figure 5 the results of a laboratory experiment are represented. When these graphs are plotted on a logarithmic scale (Figure 6), the Freundlich constant K can be determined from the intersection of the graph with the y-axis. The slope of the line is equal to the Freundlich constant n. 1 5 1 2 c equilibrium (mg/m 3 ) phenol chloro phenol dichloro phenol trichloro phenol Figure 5 - Loading capacity as a function of equilibrium concentration The higher the K-value, the better the adsorption. In Table 1 the values of the constants K and n are given for some known substances. From the structure formula of a substance, the adsorbability can be derived. In general, nonpolar substances are better adsorbed than polar substances. Substances with double bonds will be better adsorbed than substances with single bonds. q (mg/kg) 15 1 5 phenol 5 1 3 c equilibrium (mg/m 3 ) chloro phenol dichloro phenol trichloro phenol Figure 6 - Logarithm representation of the Freundlich isotherm 17

adsorption water treatment Compound K. ((g/kg). (m 3 /g) n ) alkanes 2.2 Kinetics The kinetics equation (equation of motion) for activated carbon filtration is as follows: dc dc = u k 2 (c c s ) dt dy n (-) CH 3 Cl 6.2.8 CH 2 Cl 2 12.7 12.7 CH 2 Br 44.4.81 CHCl 3 (chloroform) 95.5.67 CHBr 3 (bromoform) 929.66 CH 2 Cl - CH 2 Cl (DCEA) 129.53 CH 2 Br - CH 2 Br (EDB) 888.47 CH 2 Cl - CHCl - CH 3 (1,2 DCP) 313.59 CH 2 Br - CHBr - CH 2 Cl(DBCP) 691.6 alkenes CCl 2 = CHCl (TCE) 2.48 CCl 2 = CCl 2 (PCE) 45.52 pesticides - organochlorides Dieldrin 17884.51 Lindane (HCH) 15.43 Heptachlor 16196.92 Alachlor 817.26 pesticides - organitrogenes atrazine 387.29 simazine 313.23 pesticides - fenolderivates dinoseb 34.28 PCP 426.34 pesticides - fenoxycarbonicacid 2,4 D 1442.27 2,4,5 TP 15392.38 aromates C 6 H 6 (benzene) 126.53 C 6 H 5 Cl 917.35 CH 5 CH 3 (toluene) 51.43 C 6 H 5 NO 2 (nitrobenzene) 3488.43 C 6 H 5 COOH 282.42 C 6 H 5 OH (phenol) 53.54 C 1 H 8 (naftalene) 726.42 Table 1 - Freundlich constants K and n of several substances in which: k 2 = mass transfer coefficient (d -1 ) c = initial concentration of organic compound (mg/l) u = pore velocity of the water (m/s) c s = equilibrium concentration of organic compound linked to a certain loading of the activated carbon (mg/l) The kinetics equation consists of a convection term with which transport of the compound through the filter bed can be described: dc u dy and a removal term: k 2(c c s ) The rate of mass transfer is similar to aeration proportional to the difference between the prevailing concentration and the equilibrium concentration. The equilibrium concentration depends on the loading and is determined by the Freundlich isotherm. The lower the loading of the carbon, the lower is the equilibrium concentration and the higher is the mass transfer rate. The mass transfer coefficient depends on the compound to be adsorbed and the type of carbon (including the grain size). In addition, the mass transfer coefficient can be influenced by the velocity of the water passing the carbon grains. The higher the velocity of the water, the better the mass transfer is between liquid and carbon. 2.3 Mass balance In Figure 7 the activated carbon filter is schematized as a cube, in which: Q = flow (m 3 /h) B = width of filter (m) L = length of filter (m) 18

water treatment adsorption using the Bohart-Adams equation. This equation is derived from the mass balance and the kinetics equation. c c BV c = 1+ exp EBCT 1 2 e q ρ V EBCT = Q Q T T BV = = V EBCT Figure 7 - Schematic representation of activated carbon filter d y = height of filter (m) c = concentration of organic compound (g/m 3 ) An organic compound with a concentration c enters the system with a flow Q and leaves the system with a concentration c 1. The difference in concentration between in- and outflow is adsorbed on the activated carbon and increases the loading of the carbon. The continuity equation or mass balance is: dq v dc = dt ρ dy in which: EBCT = empty bed contact time (h) BV = filtered water per bed volume (m 3 /m 3 ) T = filter run time (h) V = volume filter (m 3 ) Figure 8 shows the progress of the organic compound concentration in the activated carbon filtration. Water with a concentration of organic compound c is supplied. Since, in the beginning, the carbon is not yet loaded, the effluent concentration of the organic compound drops to zero. After some time, the loading of the carbon increases, the available adsorption places are filled, and breakthrough of the organic compound in the effluent occurs. in which: v = filtration rate = Q/BL (m/h) q = loading (g/g) ρ = density of the carbon (g/m 3 ) c o 2.4 Solutions for the basic equations The system of equations is non-linear and cannot be solved analytically. When a stationary situation is assumed, and when the influent concentration and the flow are assumed to be constant, the effluent concentration of the activated carbon filter can be calculated H BV= t 2 t 3 t Figure 8 - Progress of the concentration in time and height 19

adsorption water treatment c e /c (-) 1.75.5.25 2, 4, 6, bed volumes (m 3 /m 3 ) THM Bentazon taste filter run time (days) 3 25 2 15 1 5 1 2 3 4 contact time (min) Figure 1 - Relationship between contact time and filter run time Figure 9 - Breakthrough curve Finally, the activated carbon is saturated without any removal of organic matter. In Figure 9 the effluent concentration is plotted against the filter run time (expressed in number of bed volumes). This curve is called the breakthrough curve. In the beginning the effluent concentration is. After time the effluent concentration increases until the activated carbon is saturated and the effluent concentration is equal to the influent concentration. When the effluent concentration of the activated carbon filter no longer meets the standards, the filter must be regenerated. The run time of activated carbon filters depends on the objective. The breakthrough of THMs occurs relatively fast (15, BV); for the removal of taste substances, however, longer run times can be applied (5, BV) without intermediate regeneration (Figure 9). Contact time The correlation between contact time and filter run time depends on the adsorption characteristics of the compound to be removed. In general the filter run time increases exponentially with increasing contact time (Figure 1). Hence, per cubic meter of activated carbon, a larger volume of water can be treated before regeneration is necessary. Application of a shorter contact time indicates that a smaller volume of activated carbon is needed. This leads to lower investment costs. The regeneration costs, on the other hand, will increase. An economical optimum depends on the adsorption behavior of the compound to be removed. 3 Practice To solve the above-given basic equation, a stationary situation is assumed in which the influent concentration is considered to be constant. In reality, the influent concentration is not constant but varies. Hence, the breakthrough curve will not describe a perfect S -form (Figure 11). If the influent concentration is high, relatively large amounts of organic matter are adsorbed because atrazine (mg/l) 2 1.5 1.5 1, 2, 3, bed volumes (m 3 /m 3 ) influent effluent Figure 11 - Breakthrough curve measured in practice 11

water treatment adsorption chloroform CHCl 3 (mg/l) 5 4 3 2 1 transport chlorination stopped t = t = T filter 1 is regenerated 1, 2, 3, bed volumes (m 3 /m 3 ) influent effluent Figure 12 - Occurrence of desorption after termination of transport chlorination t = 2 T t = 3 T filter 2 is regenerated of a large driving force. When, afterwards, a low influent concentration occurs and the loading of the carbon is already high, the saturation concentration can be almost equal to the influent concentration and adsorption is limited. In extreme cases even desorption (higher concentrations of organic compounds in effluent than in influent) can occur. This happens, for example, after terminating transport chlorination. Before termination, THMs were removed in the filters and accumulated in the activated carbon. After termination, THMs no longer form and the influent concentration is nil (Figure 12). In the effluent of the activated carbon filters, THMs are still present because of desorption. 3.1 Pseudo-moving-bed filtration A special application for activated carbon filtration is the pseudo-moving-bed system (Figure 13), where two filters are placed in a series. Figure 14 - Breakthrough curves for pseudo-moving-bed activated carbon filtration After breakthrough occurs in the first filter, the second filter takes care of the polishing, and the effluent of the second filter still meets the guidelines. The moment the second filter breaks through, the first filter is regenerated and then connected after the second filter. The cleanest filter is thus always the last one (Figure 14). The advantage of this setup is that the storage capacity of the filters is better used, resulting in longer run times. Disadvantages of this setup are the high hydraulic loadings of the filters and the complex system of pipes and valves. 3.2 Pressure filtration pump pump Figure 13 - Principle of pseudo-moving-bed filtration Figure 15 - Steel pressure filters with activated carbon 111

adsorption water treatment When activated carbon filters are placed in pressure vessels, an extra pumping phase can be avoided (Figure 15). The pressure is then sufficient to lead the water through the activated carbon filters to the clear water tanks. 3.3 Biological activated carbon filtration Biological activity occurs in all carbon filters. Bacteria that grow on the carbon will decompose organic matter. Even with pre-chlorination bacteria can grow, because the residual chlorine is adsorbed by the activated carbon. When organic matter is pre-oxidized by ozone (a strong oxidizer), biological activity is stimulated, resulting in increased filter run times and increased removal of organic matter. This is called biologically activated carbon filtration (Figure 16). Because of the increased biological activity on the carbon, the organic macropollutants (DOC) will occupy fewer adsorption places in the carbon. Hence, more space is left for the (persistent) organic micropollutants. Some persistent organic micropollutants like pesticides can even be (partially) biologically decomposed after ozonation. In some seasons (e.g., summer), the biological activity will be greater than in other seasons (e.g., winter). run time (years) 2 1.5 1.5 5 1 contact time (minutes) with ozone without ozone guideline Figure 16 - Influence of pre-ozonation on required con- Therefore, the adsorption process will be the dominant process in winter. The organic matter that is adsorbed in winter will be partially decomposed biologically in summer. This phenomenon is called bio-regeneration. With biologically activated carbon filtration, quickly degradable matter is formed that will stimulate bacterial growth. Breakthrough of this degradable matter (expressed as Assimilable Organic Carbon(AOC)) must be avoided to prevent the regrowth of bacteria in the piped network. In addition, bacteria can be eroded from the carbon and enter the effluent, thus increasing the colony counts. A disinfection step with UV-radiation or chlorine will then be necessary. 3.4 Powdered activated carbon In addition to granular activated carbon filtration (GAC), powdered activated carbon (PAC) dosing can be applied. With powdered activated carbon, small carbon particles (1µm) are added to water. These carbon particles are so small that during transport they do not settle. When the water is in contact with the carbon particles (after some time), equilibrium between the organic matter in the water and on the powdered carbon will be established. The particles will be removed afterwards by a sand filtration step. For a powdered activated carbon dosing, a mass balance can be set up, schematically represented in Figure 17 : c V + q m = ce V + qe m m c c q = W = = V q e e in which: m = mass of activated carbon e (g) 112

water treatment adsorption c q, m V c e q e, m Figure 17 - Mass balance of powderd carbon dosage V = volume filter (m 3 ) W = dosing of activated carbon (g/m 3 ) Starting with the Freundlich isotherm, the effluent concentration of an organic compound can be calculated, or the powdered activated carbon dosage can be calculated for a determined effluent concentration. It is assumed that equilibrium occurs and the carbon is maximally loaded. The loading capacity is determined by the prevailing concentration in the reactor, and in a completely mixed system this equals the effluent concentration. For two ideal mixers placed in a series, the loading capacity of the powdered activated carbon in the second tank is lower than in the first tank because the concentration in the second tank is lower than in the first tank (Figure 18). Figure 19 - Powdered activated carbon dosing unit at Scheveningen A powdered activated carbon dosage has the advantage over granular activated carbon filtration that there are limited investment costs: there is no need for a filtration installation (with an extra pumping phase); a dosing unit for the powdered activated carbon together with a mixing tank is sufficient. The removal of pesticides with powdered activated carbon, however, is limited and the rapid filters are quickly clogged. This results in a large backwash water loss. Ideal mixer, 1 - step q 1 c 1 c (mass balance) c 1 - c = W q 1 Granular activated carbon filtration has a more intensive water/carbon contact, thus pesticides (and THMs) are removed more efficiently. 2 - step q 1 q 2 c 2 c 1 c c 1 - c = -W 1 q 1 -W q 1 Figure 18 - One and two mixers in series Further reading Water treatment: Principles and design, MWH (25), (ISBN 471 1118 3) (1948 pgs) Unit processes in drinking water treatment, W. Masschelein (1992), (ISBN 8247 8678 5) (635 pgs) 113

adsorption water treatment 114