Demanded sound level meter performance characteristics according to DIN EN 61672-1:2003



Similar documents
Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

Telephone- and leased line modem for industrial applications TD-36

Dual Chamber Temporary External Pacemaker

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Rack mounted telephone- and leased line modem for industrial applications

Sound Level Meters Nor131 & Nor132

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

30 In Compliance October

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Integrating Sound Level Meter and Datalogger

Waveguide Access Point WGA631. Product Guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Test Report #: Date: April 8, 2005

EMC Test for Compliance with EU EMC Directive 2004/108/EU

One Port Network Analyzer

Regulatory requirements - USA

15 Series - Electronic step relay and dimmer. Features SERIE

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Hear The Future...Now! SIEM-2T/SIEM-2R

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

PRODUCT DATA Mediator Class 1 Integrating Sound Level Meters

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Impedance 50 (75 connectors via adapters)

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Indoor / Outdoor Antenna

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

NI USB-5681 RF Power Meter Specifications

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

MEASUREMENT UNCERTAINTY IN VECTOR NETWORK ANALYZER

80 Series - Modular timers 16 A. Features

ETSI EN V1.2.2 ( )

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Technical Data. back-up time in minutes 100% load % load

IEC and CISPR Standards

Multifunction devices

Features. Picture. Specifications

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 Series - Relay interface modules A

Experience with taximeters with a look at the corresponding tables

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

R&S ZNC Vector Network Analyzer Specifications

Energy Management Energy Meter Type EM23 DIN

R&S ZNBT8 Vector Network Analyzer Specifications

MasterINTERFACE 39 Series - Relay interface modules

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

SC-30 INTEGRATING SOUND LEVEL METER REAL TIME FREQUENCY ANALYZER

MAINTENANCE & ADJUSTMENT

RECOMMENDATION ITU-R BS.704 *, ** Characteristics of FM sound broadcasting reference receivers for planning purposes

Certificate: _01 / 29 April 2014

TENSIONMETER ** code 183_LNRSTW **

38 Series - Relay interface modules A

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

T200, PTP/IEEE 1588 Grandmaster Clock and

MasterINTERFACE 39 Series - Relay interface modules

Fast and Accurate Test of Mobile Phone Boards

Network analyzer and spectrum analyzer two in one

WIRELESS MAGNETIC CONTACT

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

80 Series - Modular timers 16 A. Features

Electromagnetic Compatibility Test Report Test results of Floww equipment

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

SMARTPHONE AS NOISE LEVEL METER? Jacopo Fogola, Stefano Masera, Vincenzo Bevacqua Environmental Protection Agency - Piedmont Region, Turin, Italy

#

Certificate: / 20 August 2013

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

Digital Magnetometer Systems - DM Series

USB-to-Data Highway Plus Cable

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

TETRIS High Impedance Active Probe. Features:

TECHNICAL TBR 12 BASIS for December 1993 REGULATION

GSM frequency planning

R&S ZVA Vector Network Analyzer Specifications

DATA SHEET DVI - HDCP Extension Cable

Preset Counter signo 721

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Generic - Hearing Loop - (AFILS) U.S. System Specification

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

Design and Certification of ASH Radio Systems for Japan

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Measurement, analysis, and monitoring of RF signals

ANSI Watthour Meter Testing & Certification Programs

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Transcription:

Demanded sound level meter performance characteristics according to DIN EN 1.1 Anwendungsbereich 5.1.9, 5.1.10 Allgemeines Demanded functions class 1 instruments: - L AF, - L AFmax - L Cpeak, L c - (L Aeq ) - (E A) Demanded functions class 2 instruments: - L AF, - L AFmax - (L Aeq ) - (E A) 5.1.14 Allgemeines Exist types of measure L xymax and / or L cpeak, functions Start, Stop and Clearing have to be available 5.1.15 Allgemeines A device to insert electrical test signals is to send to the test lab. 5.1.17 Allgemeines Is the sound level meter equipped with multi-channels, the channels have to be assigned clearly to the input sockets. 5.1.18 Allgemeines The initial time interval shall not exceed 2 minutes after switching on the power. The initial time expiration has to be indicated. During this time a start of measure periods has to be prevented. 5.2.1 Pegelkorrektur The sound level meters type label indicates registered calibrators. siehe auch 9.2.5 a) Leistungsmerkmale_61672_en.doc Vers. 2 Seite 1 von 6

5.2.2 Pegelkorrektur The calibrators performance classification corresponds at least with the one of the sound level meter. The specified calibrator is not a laboratory standard sound calibrator 5.2.6 Pegelkorrektur Maximum deviations of measured correction values from manufacturer specifications: two thirds of the values in table 2 5.5.4 Pegellinearität On the reference level range, the extent of the linear operating range shall be at least 60 db at 1 khz. 5.5.8 Pegellinearität Required overlap of adjacent linear operating ranges of sound level meters, - measuring exclusively time-weighted > 30 db, - measuring time-average - or sound exposure level > 40 db 5.10.1 Bereichsüberschreitungsanzeige siehe auch 9.2.6 k) 5.10.4 Bereichsüberschreitungsanzeige 5.10.5 Bereichsüberschreitungsanzeige The sound level meter has an overload indicator that shall be operative for each applicable display. Exist several overload displays, they have to be exactly synchronized. At measurements of time-weighted and overload sound levels lasting less than 1 s, an overload indication of at least 1 s has to be presented. At longer overload sound levels an overload indication has to be presented at least as long as the overload condition exists. Is one of the measurement functions L eq E A L smax / L fmax L cpeak 5.11.1 Bereichsunterschreitungsanzeige siehe auch 9.2.6 k) or another time interval related type of measure available, a latch on overload indicator has to be integrated. At levels underneath the linear operating ranges an under-range condition has to be displayed before the tolerance limits on level linearity error are exceeded. The under-range display shall be presented as long as the condition continues, but at least 1 s. Leistungsmerkmale_61672_en.doc Vers. 2 Seite 2 von 6

ų 24.01.06 5.12.1 C-bewerteter Spitzenschallpegel siehe auch 9.2.3 i) 5.13.1 Zurücksetzen siehe auch 9.2.6 i) The display range for peak C sound levels should be at least 40 db in reference level range. Is one of the measurement functions L eq E A L smax / L fmax L cpeak or another time interval related type of measure available, facilities have to be contained to clear the data-storage device and re-initiate a measurement. Time interval related types of measure have to be legible as constant numerical value after the end of the measuring period. 5.13.2 Zurücksetzen The reset facility transports all time interval related types of measure in a defined starting condition. Incorrect value display for time interval related types of measure should be ruled out. 5.15.1 Anzeige In case several measurement quantities can be displayed, it has to be possible to indicate them clearly. 5.15.3 Anzeige The display resolution has to be 0,1 db or lower. The display range has to comprise at least 60 db. 5.15.4 Anzeige Digital display: The chosen type of value is continually up-dated. 5.17.1 Vorrichtungen zur Zeitmessung siehe auch 9.2.6 g) 5.18.2 Hochfrequenzaussendung und Störungen des öffentlichen Stromnetzes During time interval related measurements elapsed time is constantly displayed. For test purposes it has to be possible to select at least one pre-set time interval of 10 s. Maximum values of radio frequency emission: 30 db for frequencies from 30 MHz to 230 MHz. 37 db for frequencies from 230 MHz to 1 GHz (reference: 1 V/m, distance 10 m) Leistungsmerkmale_61672_en.doc Vers. 2 Seite 3 von 6

5.18.3 Observance of maximum values by power supply feed back according to table 5. Hochfrequenzaussendung und Störungen des öffentlichen (Demands are complied with when interfering voltage peaks amount to less than Stromnetzes corresponding average values.) 5.19.1 Übersprechen In case several measuring channels are available, the channels have to be assigned siehe auch 5.1.17, 5.19.2 clearly to the displayed types of measurement. The signal space caused by channel crosstalk has to amount to at least 70 db in the described test procedure. 5.20.1 Stromversorgung Indication for sufficient power supply. 5.20.2 Stromversorgung At an unstable power supply of the sound level meter the error limits demanded in the siehe auch 9.3 j) manual have to be met. 6.1.3 en allgemein 6.1.4 Umgebungsbedingungen allgemein 6.2.1 Stat. Druck 6.2.2 Stat. Druck 6.3.3 Lufttemperatur PTB-Forderung The fixed sound calibrator operates in a 125 Hz to 1250 Hz frequency range. The calibration level dependance of the fixed sound calibrator on the surrounding conditions is known. Test at surrounding conditions excludes condensation above +39 C or below 15 C. Observance of demanded error limits (class1 ± 0,7 db, class 2 ±1,0 db plus expanded uncertainty of measurement) at static pressure ranging from 85 kpa to 108 kpa. Observance of demanded error limits (class1 ± 1,2 db, class 2 ±1,9 db plus expanded uncertainty of measurement) at static pressure ranging from 65 kpa to 85 kpa. Observance of demanded error limits: Class 1 ± 0,8 db plus expanded uncertainty of measurement at range of 10 C to + 50 C and relative humidity between 25 % and 90 % Class 2 ± 1,3 db plus expanded uncertainty of measurement at range of 10 C to + 40 C and relative humidity between 25 % and 90 % Only relevant to PTB test Leistungsmerkmale_61672_en.doc Vers. 2 Seite 4 von 6

6.4 Feuchte (gleichbedeutend mit 6.3.3) 6.5.1 elektrostat. Entladung 6.5.2 elektrostat. Entladung siehe auch 9.2.8 b) 6.6.1 Netz- und Hochfrequenzfelder 6.6.6 Netz- und Hochfrequenzfelder 6.6.7 Netz-- und Hochfrequenzfelder Observance of demanded error limits: Class 1 ± 0,8 db plus expanded uncertainty of measurement at range of 10 C to + 50 C and relative humidity between 25 % and 90 % Class 2 ± 1,3 db plus expanded uncertainty of measurement at range of 10 C to + 40 C and relative humidity between 25 % and 90 % Without condensation at range of + 39 to + 50 C and below 15 C! The sound level meter continues to operate as intended after exposure to a contact discharge of ± 4 kv and air discharge of ± 8 kv. Electrostatic discharges according to 6.5.1 do not result in: - Change of operating state - Change of configuration - Corruption of stored data - Loss of stored data The defined power- or radio frequency fields do not cause: - Change of operating state - Change of configuration - Corruption of stored data - Loss of stored data Observance of demanded error limits: Class 1 ± 1,3 db plus expanded uncertainty of measurement Class 2 ± 2,3 db plus expanded uncertainty of measurement Deviation of display with / without power resp. radio frequency field influence Group Y and Z sound level meter interference immunity to - radio frequency common mode interference - fast transients on the power supply - voltage dips as described in the standard. Leistungsmerkmale_61672_en.doc Vers. 2 Seite 5 von 6

6.6.8 Netz-- und Hochfrequenzfelder Group Z sound level meter interference immunity to - radio frequency common mode interference - fast transients on the power supply as described in the standard. 8.1 Kennzeichnung Sound level meter marking: - standard reference number and date of publishing - responsible supplier / manufacturer - model designation - serial number - performance class according to standard 8.2 Kennzeichnung Principal components (basic instrument, pre-amplifier, microphone) of the sound level meter have to be marked with model designation and serial number. The software version has to be recognizable. 8.3 Kennzeichnung Communication interfaces and other electrical connections have to be logical and free of electrical interference. It has to be possible to seal the body of the sound level meter. 9.1 a-c Bedienungsanleitung Each sound level meter shall be supplied with a printed instruction manual that conforms to standard specifications. Anlage 21 zur Eichordnung Bedienungsanleitung The instruction manual has to be easy to understand and in German language. Leistungsmerkmale_61672_en.doc Vers. 2 Seite 6 von 6