ORGANIC SAMPLE PREPARATION



Similar documents
How To Test For Contamination In Large Volume Water

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

German engineering under high pressure

AIRFREE TECHNIQUE AND SENSITIVE REAGENTS S ECTI O N 1: GLASS W ARE A ND E Q UIP M ENT. A. Using a manifold

Innovative vs Traditional

Waters Corporation. Waters 2690/5 USER & TROUBLESHOOTING GUIDE

Purification of reaction mixtures using flash chromatography.

MILESTONE START D. Microwave Digestion System

Mitos P-Pump. product datasheet

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Elemental analyzer multi EA 5000

MILESTONE CLEAN CHEMISTRY LINE DUOPUR TRACECLEAN ULTRA-TRACE INSERTS. A Breakthrough in Reduction and Control of the Analytical Blank MILESTONE

Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

MILESTONE. SynthWAVE. The Game Changer in Microwave Synthesis

GC-xt. The most flexible GC /GC-MS liquid sample injector

Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein

Designed for multi-injector endurance testing, the

Full Technical Catalog For Closed-loop Sampling System

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

METHOD 3510C SEPARATORY FUNNEL LIQUID-LIQUID EXTRACTION

Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

FPLC standard operating procedure AKTA system (GE)

A Practical Guide to Free Energy Devices

LyoBeta. R+D Freeze-Dryers

Car and commercial cial air conditioning service solutions

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

EcoCWave. The all-round talent for aqueous part cleaning.

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

High pressure reactors Where are your limits?

TENDER DOCUMENT PURCHASING EQUIPMENT FOR PEPTIDE SYNTHESIS

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Sterilizers with extra class

MILESTONE H E L P I N G C H E M I S T S

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

This study was performed by Patrick Sullivan and staff at TestAmerica Analytical Testing Corp., Westfield, MA, USA

COMMON LABORATORY APPARATUS

AUTOMATED SAMPLE PREPARATION INTELLIGENT SYSTEM SOLUTION

Oasis HLB Cartridges and 96-Well Plates

Brownie s. Tankfill. and. NitroxMakers

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

Determination of Fat in Dried Milk Products Using Accelerated Solvent Extraction (ASE)

MILESTONE. RotoSYNTH. Rotative Solid-Phase Microwave Reactor

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Ordino Autoclave Controller CS340 CS350 CS400 CS360

Vacuum drying oven for non-flammable solvents

SPE-TT. Tutorial Version Bruker BioSpin ; File: Tutorial 11 - SPE-TT; Version: ; By: Dr.

Computer Controlled Vortex Tube Refrigerator Unit, with SCADA TPVC

Focus XC. Ultimate Fully Automated Peptide Synthesizer with Sonication and Heating Options

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

globe reactions made easy Process perfection

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

FVA/A1 saturated-steam sterilizer

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

M I C R O W A V E E X T R A C T I O N S Y S T E M THE NEW MILESTONE MILESTONE

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

DMA-1 Direct Mercury Analyzer

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Hospital Sterilizers. T-Max Line

OT 40L / 90L. Laboratory Steam Sterilizers

Drum Washers - Barrel Washers

Coating and Extraction of Honeycomb Denuders

AUTOCLAVE STEAM STERILIZERS

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Laboratory Autoclave SN210/310/510,SQ510/810

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

ArtisanLink Staining System is an automated special stains slide

The Sievers 900 Series TOC Analyzers

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Element D Services Plumbing

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Multifunctional Autosampler AOC-6000 C146-E272A

EKSIGENT EKSPERT NANOLC 400. Unmatched flexibility for low flow LC/MS

PARALLEL AUTOCLAVABLE MINI FERMENTERS/ BIOREACTORS

Specials. designed. 3rd edition 2015 English. for scientists 1

Optimize Your Process Operations by Improving Process Monitoring

Modular Glovebox Systems Gas Purifier Units Antechambers Accessories

On-line Dissolved Gas Analysis

LABOKLAV. Autoclaves Made in Germany.

AUTOMATED SAMPLE PREP CAPITAL EXPENDITURE JUSTIFICATION REPORT

Protocol: HPLC (amino acids)

Calibration of Glassware

ChromQuest 5.0 Chromatography Data System

FRACTION COLLECTOR. Microcomputer Controlled CHF122SC

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Medical Waste Autoclaves. Medical Waste Autoclaves

Water Baths. with BioCote antimicrobial protection

Transcription:

ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M

WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems, LabTech WSPE vacuum manifold installs a patented valve system able to grant precise flow control through each cartridge. WSPE vacuum manifolds allows users to process up to 12 (WSPE12) or 24 (WSPE24) samples simultaneously. Glass base resistant to solvents preventing condensation and discolour Anticorrosion cover to avoid deformation under high-pressure working conditions High quality and reliable PTFE rack Screw-type solvent resistant vacuum regulator for accurate vacuum control PTFE rack for 11, 13 and 15mm tubes to satisfy daily use and all of customer needs

EXTRAPID MANUAL CARTRIDGE-DISK EXTRACTOR Extrapid manual SPE system is the ideal partner when treatment of large volume samples is required. A unique and flexible extraction solution for standard and routine SPE needs in environmental analysis. 3-ways valves to efficiently control the sample collection and the waste discharge During operation process: - No need to switch ON/OFF the vacuum pump - No need to wait for venting and removing collection vials - No need to drain the waste liquid and clean vacuum chamber Up to 4 samples run individually or simultaneously 1, 3, 6ml cartridge and 47, 90mm disk options Flow control valve ensuring accurate flowrate and high reproducibility Sample flowrate from 1 to 45ml/min Parts directly in contact with solvents made of PTFE or stainless steel to ensure excellent anticorrosion resistance Standard configuration Main unit Collection bottles Clamp ring Waste liquid bottle Vacuum pump Optional accessories 10L waste liquid tank 1L sampling glassware device 20L waste liquid tank 90mm/C18 SPE disk 90mm SPE disk adapter

SEPATHS UP THE INNOVATIVE SPE SOLUTION Sepaths UP is designed for both cartridge and disk applications to treat samples with different volume. It can be applied to extract trace organic compounds from drinking water, surface water, ground water, food, beverage and other samples. Sepaths UP automatically treats from1 to 12 same or different samples, through the whole treatment process, including condition, sample loading, rinsing, elution and concentration. It is a closed system able to completely remove solvent vapours trough the included exhaust line. 1 to 120ml/min flow rate Accurate control loading rate of small amount of sample Sample volume from 1ml to 20L Different cartridge and disk available Different sample collection vials options Display for real-time process Solvent and sample management system Fast concentration nitrogen flow Optional concentration module Automatic spray cleaning of sample bottles Possibility to manage via software up to 8 solvents Separated aqueous and organic waste collection Possibility to separate different sample phases Possibility to configure the system with 4, 6, 8, 10 or 12 samples 1 to 12 samples run simultaneously High pressure protection system Intuitive and easy to use software

Complete software solution Possibility to run simultaneously different methods Real-time process monitoring Possibility to modify and create customized methods Optional Concentration Module Dedicated concentration for each channel Concentration accuracy of 0.1% Temperature control range: ambient to 120 C Fast concentration by nitrogen flow Channel number Sepaths UP-4 Sepaths UP-6 4 6 8 10 12 Modular configuration for different number of sample channels

SEPLINE-S AUTOMATION AND PRODUCTIVITY CONCEPT SepLine-S automated solid phase extractor is the result of latest liquid-solid extraction techniques and mass chromatography highest requirements in terms of sensitivity and reproducibility. Largely used in environmental protection, food, petrochemical, pharmaceutical, clinical, life sciences and other applications thanks to its flexibility. SepLine-S series includes three models: Single, Dual and Four-channels. Condition, sample loading, rinsing and elution steps are processed automatically by software according to user needs. A unique low-pressure sealing technology accurately controls the liquid flow through the syringe and avoid cross contamination. Multi-channel mode improves the efficiency of the SPE method and guarantees reproducibility and stability of sample pre-treatment. LIQUID SEPARATION BY AIR BUBBLE Thanks to air bubble, SepLine-S is able to avoid liquid mixing when two different solvents and/or samples flow into the liquid circuit. Advantages are: to prevent polarity change to improve sample recovery PRECISE FLOW RATE CONTROL High precision syringes High precision quantitative tubes to ensure accurate control of sample and solvent dispensing Flow accuracy: 0.1% Flowrate: from 0,1 to 100mL/min

SepLine-S1 SepLine-S2 SepLine-S4 Single channel AutoSPE system to perform single sample batch processing. It can automatically achieve conditioning, sample loading, rinsing and eluting steps. Thanks to the included nitrogen purge module, SepLine-S is the ideal partner for routine and R&D needs in the organic sample preparation. The new quantitative concentrator can be connected to the main unit by a plug-and-play procedure. Dual channels AutoSPE system to perform simultaneously two samples. Management system allows running different methods for each channel. Four channels AutoSPE system to perform simultaneously four samples, improving efficiency and productivity. Automated process of sample transfer, rinse, loading, dry, washing, elution Positive pressure pump to ensure accurate flow rate and high recovery Automated holder for up to 60 cartridges controlled via software Unique low pressure sealing tech and air bubble technique to prevent sample/solvent cross contamination Standard nitrogen blow function Up to 8 different solvents managed by software Septum piercing function to prevent solvent evaporation Dispensing needle cleaning function to avoid cross contamination during liquid handling Different volume sample vials and rack options User friendly software with intuitive graphic interface Optional sample tray cooling device

CARTRIDGE HOLDER MODULE SPE cartridges are moved by sliders to the set position via software Optimized design to allow cartridge exchange 60 sample extractions automatically handled via PC software Compatible with the majority of SPE cartridge specifications Fully closed treatment process to avoid solvent vapours to ambient SPE OPERATION MODULES Positive pressure extraction mode to ensure stability of the recovery rate Low-pressure sealing technology Air bubble technique to prevents solvent/sample cross-contamination Closed system to ensure environmental protection. No additional consumables required Possibility to upgrade the SepLine-S Single channel unit to multi channel versions AUTOMATIC LIQUID HANDLER Management of both sample injection and collection via software Optional cooling sample tray Fully closed system Possibility to choose the cleaning method and time. Needle is cleaned by immersion to avoid cross contamination Petrochemical Environmental Clinical Food Pharmaceutical Energy

E.T. CONCENTRATOR BASIC SOLUTION FOR ANY LABORATORY Up to 6 samples Parallel concentration model Possibility to simultaneously or separately work with six channels Nitrogen blow in combination of heating concentration mode Dry block heating mode to avoid potential water vapour interference P.I.D. temperature control with digital display Possibility to choose the best position of nitrogen needle to ensure the most efficient evaporation Dedicated nitrogen flow regulator control for each sample channel Compatibility with collection vials of Sepaths UP Unique open view to control sample volume level during the evaporation process

MULTIVAP AUTOMATED CONCENTRATION SOLUTION The new LabTech MultiVap8 automatic parallel system increases the capacity and sample throughput in laboratories, and maintains quality and lower costs. With this system, users can evaporate to solid state or concentrate into a fixed end-point volume. A compact solution compared to conventional rotary evaporators, with the possibility to be used outside fume hood thanks to the integrated vapour exhausting system. Vortex nitrogen purge to get the highest concentration efficiency. The location and direction of nitrogen purge can be adjusted according to the concentration cup size and sample volume Operations visible through the backlit front window. Sample cups do not need to be handled to check the residual volume Sealed concentration chamber including a high efficient vapour exhausting system Built-in digital nitrogen gas regulator to control the nitrogen flow and the evaporation speed Automatically detecting the liquid endpoint 8 positions supporting 50 & 200ml concentration cups simultaneously 8 infrared sensors for single cup volume control Possibility to place concentration cups in the liquid handler of GPC/SPE directly Liquid bath with temperature control range from ambient to 99.9 C Low liquid level and pressure alarms to ensure safe operations Touch screen control interface Solvents Original volume Time to 1ml Evaporation speed Dichloromethane 180 ml 20 min 9.0 ml/min Hexane 180 ml 18 min 10.0 ml/min Methanol 180 ml 50 min 3.6 ml/min Acetone 180 ml 23 min 8.0 ml/min Water bath temperature 60 C

MV5 AUTOMATED CONCENTRATOR REVOLUTINATY CONCEPT! MV5 is the latest multi-channel and multifunctional parallel instrument designed by LabTech, including all accessories and functions to grant highest standard of efficiency, speed, reliability, throughput and safety of any concentration process. Nitrogen sweeping, needle level adjustment and visible concentration process are only few of the advantages offered by MV5. 54 sample positions able to work either individually or simultaneously Automatic adjustment of nitrogen needle according to the sample volume reduction Visible concentration process thanks to the front window and internal lights Auto-locked cover during operations Easy replacement of nitrogen needles 7 touch-screen color control panel Low-level liquid alarm Intuitive software interface HEATING MODULE Liquid bath heating mode Temperature reading error: < 0.5% Temperature control: P.I.D. Temperature accuracy: ±0.1 C Temperature range: ambient to 100 C

W W W. L A B T E C H S R L. C O M The solution to your laboratory needs. LabTech is a young manufacturing company with skill and passion, devoted to provide advanced laboratory solutions to the analytical community. We are located in Sorisole, northen of Italy with facilities in USA and China. Incorporated with global branches, LabTech is organized with R&D, production, marketing & sales and customer support. Major LabTech products include organic/inorganic sample preparation systems, laboratory cooling/heating/temperature control equipments, analytical instruments, laboratory information management system and laboratory design and engineering. With knowledgeable scientists and experienced engineers, our R&D team has developed and released a series of new lab equipments and instruments. With all these accomplishments and our never stopping efforts on research and development, we are proud of being one of few providers able to produce the most advanced sample preparation products. RoHS compliant COOL GREEN LabTech Srl Via Fatebenefratelli, 1/5-24010 Sorisole (BG) - Italy Tel: +39 035 576614 - Fax: +39 035 4729414 www.labtechsrl.com - email: marketing@labtechsrl.com