radon solutions in homes

Similar documents
Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

2014 British Columbia Building Code Changes

FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS

State of Connecticut Department of Public Health RADON PROGRAM

plumbing products guide

Energy Company Obligation (ECO): Technical Monitoring Questions

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

INDUSTRY GUIDANCE FOR INSTALLERS ON CONDENSATE DRAINAGE PIPE INSTALLATION. This guidance is endorsed by HHIC members.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

ECHO System for Basements

SUMMARY REPORT THE BOTTOM LINE. Electrical. Report Number: Inspection Date: Saturday, February XX, XXXX

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Technical Bulletin 005(A) Developed with Communities and Local Government

Best Basement Water Management Practices

LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION

Contents. Who is Premier Guarantee? Your Structural Warranty. What to look out for in your New Home. Running in your New Home. DIY and Maintenance

Basement Development Construction requirements for the development of basements in residential dwellings.

A Homeowner s Guide to Radon

HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER May 2015

Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings

Energy Saving Fact Sheet Boilers

Preventing Ice Dams on Roofs

bout your HOUSE before you start Renovating Your Basement Moisture Problems

Safe Method: Gas Safety in Catering Establishments

How To Design A Gas Dryer

Is an air source heat pump the right choice for my home? Important information and key things to consider before installing an air source heat pump


WATER LEAKS AND DAMAGE

Module 3.7. Thermal bridging

HVAC Code Requirements

RADON AND HEALTH. INFORMATION SHEET October What is radon and where does it come from?

UNDERSTANDING CENTRAL HEATING SYSTEMS

Protect your pipes. Keep the water cycle running smoothly and be prepared in winter. Heat, insulate and protect your home.

bout your house before you start Renovating Your Basement Moisture Problems

Case Study Family Room Renovation 3br family home, Melbourne

For installation guide see reverse of book

Dealing With RADON in Real Estate Transactions

NUAIRE VENTILATION SYSTEMS DRIMASTER, DRIMASTER 3S, DRIMASTER 2000 AND DRIMASTER S SYSTEMS

Meaco 30L and Meaco 40L dehumidifier instruction manual

bout your apartment SOLVING ODOUR TRANSFER PROBLEMS IN YOUR APARTMENT Understanding Air Movement in Your Building

Guide to Improving Your Home

Asbestos in the home. for you - for your community - not for profit

Prepare your property for flooding

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

Controlling moisture. For your home. Bellevue, WA Puget Sound Energy. pse.com/myrebates. P.O. Box /14

Te c h n i c a l G u i d a n c e D o c u m e n t

BUILDING SAFETY UNIT

Residential Foundations and Basements

Response, Reliability and Results in the delivery of leak detection services

bout your HOUSE before you start Renovating Your Basement Structural Issues And Soil conditions

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

October 5, 2015 Dear Client,

Gas appliances. Get them checked Keep them safe. The problem

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

GUERNSEY OIL INSTALLATION GUIDELINES

Services Enclosures and Protected Shafts - Maintaining Compartmentation

DOMESTIC SMOKE ALARMS

Heating and cooling. Insulation. Quick facts on insulation:

Dealing With RADON in Real Estate Transactions

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Making changes to your home

Vision Home Inspection

Self-Home Inspection Checklist

Condensation. Some Causes, Some Advice

Sports Buildings: budget costs for the Flood Relief Fund

Molds and mildew are fungi that grow

Cool air quietly and efficiently. A guide to buying and operating an air conditioner

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

Fire Standards & Regulations Are you confused?

Gramercy Place Condo Association, Inc.

Fire Alarm system Installation Guide

Housing Services Guidance for tackling condensation, damp and mould in your home

bout your house before you start Renovating Your Bathroom

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Response: The combi boiler. Response: The fit anywhere combi

ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards

Application for the Alteration of a Gas Supply

TOP 10 NOISE CONTROL TECHNIQUES

Building Control Guidance Note

Excerpts from the Canadian National Building Code (NBC)

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

PRESTRESSED CONCRETE FLOORING BEAMS

Building Condition Assessment Report

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

PERFORMANCE GUIDELINES

Asbestos in the home. WHERE it may be found WHAT to do if you find it. Date: 15/08/14

Rehab Inspection Report Page 1

Guidance on loft conversions in two-storey houses

PUBLIC MINUTES PROPERTY MAINTENANCE APPEALS BOARD. Wednesday, November 25, 2015, 3:46 p.m. Committee Room B, City Hall

Personal Tax Planning - What is a Resiliant or Resistance Measurement?

Inspection Item COMMENTS

Basement Moisture Problems

SPECIAL APPLICATIONS

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Transcription:

GOOD repair GUIDE GRG 37/1 radon solutions in homes Improving underfloor ventilation Chris Scivyer This Good Repair Guide offers guidance to builders and homeowners carrying out installation works to increase ventilation under suspended ground floors. It covers the installation of both natural and mechanical (fan-assisted) ventilation to underfloor spaces. Advice is also given on system maintenance and what to do if a system fails to adequately reduce radon levels. This Good Repair Guide is Part 1 in a 3-Part set and replaces the guidance given in BRE Report BR 270. Parts 2 and 3 cover positive house ventilation and sump systems. Locating airbricks on the opposite sides of the underfloor space allows for complete cross ventilation Background Radon Radon is a naturally occurring radioactive gas that is present in all buildings. Prolonged exposure to high levels causes lung cancer The Health Protection Agency (HPA) recommends that householders with concentrations above the action level (200 Bq m -3 ) should reduce their radon concentrations as far as they can and ideally to below the target level (100 Bq m -3 ). Improving underfloor ventilation If part, or all, of the ground floor is of suspended timber construction, improving underfloor ventilation may be an appropriate method for reducing indoor radon levels. Suspended timber floors should be well ventilated to reduce the risk of timber rot and musty smells. Ideally, there should be vents in the walls on either side of the floor to encourage cross-ventilation and minimise dead areas beneath the floor (Figure 1). Improving underfloor ventilation to reduce radon levels therefore also benefits the floor in other ways. Poorly located airbricks cause areas of poor ventilation (dead areas) Dead areas Figure 1: Examples of (a) good ventilation (b) poor ventilation Improved natural underfloor ventilation is generally effective for radon levels up to 500 Bq m -3. It may be effective with higher levels but if not an underfloor fan could be added later. Often with higher levels, mechanical underfloor ventilation (using a fan) or an alternative solution will be required.

2 radon solutions for homes: improving underfloor ventilation GRG 37/1 Suspended timber floors Suspended timber ground floors can be found in homes of all ages. There are two quick ways of finding out if a floor is suspended timber (or wood-based boarding such as chipboard or laminate flooring): roll back any floor coverings and see if the surface of the floor appears wooden and sounds hollow when tapped look outside for underfloor ventilation grilles or air bricks in the walls. They will be just above ground level in the external walls of the rooms with timber floors. If underfloor grilles are not visible, the timber floor may be laid directly on a concrete slab in which case underfloor ventilation is not needed and the floor will need to be treated as a concrete floor when considering an appropriate radon solution. Suspended concrete floors Suspended concrete beam and block floors have only become common since the early 1980s before which they tended to only be used on sloping sites. These floors can be difficult to identify as the floor finish will be similar to a solid concrete floor. Since the early 1990s, however, most suspended concrete floors have included ventilation grilles or air bricks in the walls. If provided, these will be visible outside just above ground level in the walls alongside the rooms with suspended floors. If underfloor vents are not visible the concrete floor may be laid directly on the ground and will need to be treated as a concrete floor when considering an appropriate radon solution. In either case, if you are still unsure, ask a builder to check for you. Solutions for improving underfloor ventilation Underfloor ventilation can be improved by: increasing the natural ventilation providing mechanical ventilation. Increasing natural underfloor ventilation This involves clearing out or replacing existing underfloor ventilation grilles or air bricks, or adding additional vents. It is suitable for homes with indoor radon concentrations of up to 500 Bq m -3. How it works Due to slight differences in indoor and outdoor pressures caused by wind and temperature differences, a building acts like a chimney drawing radon from the ground up into the building. By providing more open or additional underfloor ventilation grilles around the building the radon in the air beneath the ground floor can be diluted. Less radon is drawn into the building because the air contains less radon. What to do Check and clear existing ventilation grilles It is common for underfloor vents to become blocked so that they no longer provide adequate ventilation to the Figure 2: Examples of ventilation grilles that are blocked, covered or obstructed

radon solutions for homes: improving underfloor ventilation GRG 37/1 3 underfloor space. They may have become blocked with dirt, obstructed by foliage, raised paving or driveways, or deliberately blocked by householders to reduce draughts or for some other reason (Figure 2). Sometimes, additional building works such as an extension, conservatory or garage or even pipework could block existing underfloor vents and therefore additional vents will be needed. In the past, underfloor vents would usually be visible just above the ground. With homes built since the early 1990s, this is not always the case. Instead, vents are often set below ground within a well to maintain a level threshold for disabled access. These wells can quickly fill with debris which blocks the vents (Figure 3). Check the vents in cavity walls Vents in cavity walls should be sleeved through the wall so that air can flow freely from outdoors into the underfloor space (Figure 4). Unfortunately, the bricks or blocks used in each leaf of a cavity wall rarely align with each other making it difficult to install sleeves. Therefore, builders simply install vents in the external leaf and expect the air to find its way under the floor via open gaps in the masonry joints. Consequently, little ventilation reaches under the floor. To check whether a vent is open, push a knitting needle through it into the underfloor space. Similarly, if the house has had cavity wall insulation injected, check that the vents were not blocked during installation. This solution is appropriate for houses with radon levels below 500 Bq m -3. It is often possible to reduce the radon level to well below the action level by simply clearing major obstructions from existing air bricks. How many vents should there be? Guidance on specifying vents is as follows. Ideally, vents should be provided on at least two opposite walls to allow through-ventilation. The depth of the space beneath the floor can vary from virtually nothing to a more typical 450 600 mm. For floors with an underfloor space of this depth, vents should be large enough to give an actual opening of 1500 mm 2 for each metre run of wall. Typically, vents having the size of a house brick should be spaced every 1.5 2.0 m around the perimeter of the building. If the space beneath the floor is deeper as is common for a building located on a sloping site, even more vents will be needed to ventilate the larger space. The layout of the building and location of suspended floors will limit where additional vents can be installed. It is rare for a house to have the entire ground floor constructed of suspended timber. Typically, the floor construction in wet areas such as kitchens, bathrooms, utility rooms and sometimes hallways is not suspended, preventing through-ventilation. In addition, access for installing vents may be obstructed by entrances or fireplaces. Terraced properties are often the most difficult to deal with as rear rooms and the hallway often have concrete floors, leaving just a short length of the front wall in which to install vents. Ideally, there should be at least two vents to facilitate circulation of air under the floor. Figure 3: Partially and fully obstructed vents set below ground level in newbuild homes (a) (b) Figure 4: through (a) an unsleeved vent through cavity wall, (b) a sleeved vent through cavity wall

4 radon solutions for homes: improving underfloor ventilation GRG 37/1 When constructed, separating walls between rooms should have been perforated below the floor to allow air flow between underfloor spaces. Lift a floor board or remove an airbrick to check. If the underfloor spaces are not interlinked then ventilation should be provided to each individual underfloor space. Replace existing vents Often the original vents have little open area. This is particularly so with some old-style terracotta air bricks and cast iron vents (Figure 5 a c). Simply replace all existing terracotta vents with plastic louvred vents that allow a greater flow of air (Figure 5 d, e). Doubling the underfloor ventilation can often halve the radon level. Use more open vents but choose ones that are sufficiently screened to prevent entry by vermin. Install additional vents Where few or no vents have been provided additional vents should be installed. Using the more open plastic louvred vents rather than terracotta air bricks is recommended. Vents can be installed through brick or concrete block walls reasonably easily. Consider using a 110 mm diameter core drill when breaking through a thick stone wall. Circular grilles are available from builders merchants and DIY stores. Vents should be installed above ground level but located to provide ventilation beneath the floor. Where the ground level is high, periscopic ventilators will be required, although increased breaking out will be needed to fit this type of vent (Figure 6). Install cowled vents Draughts can be prevented in exposed locations by fitting cowled vents that are designed to allow free air entry but act as a baffle to gusts of wind (Figure 7). Providing mechanical ventilation How it works Mechanical underfloor ventilation can be used with suspended floors where natural underfloor ventilation would be inadequate. This method has been used in homes with indoor radon concentrations at all levels. Fans can be installed to blow air into the underfloor space (supply ventilation) or suck air from it (extract ventilation). Both extract and supply ventilation have been used successfully. Success depends on many factors, including soil permeability, floor leakiness, the number and position of air bricks, etc. The usual approach is to try one method, and if that does not work reverse the fan, ie use extract instead of supply ventilation or vice versa. Mechanical underfloor ventilation works mainly by diluting radon in the air beneath the floor. However, extract ventilation also provides some extraction of radon and supply ventilation provides a slight pressurising effect which reduces radon entry into the underfloor space. What to do In most cases, an existing airbrick is removed and replaced by a short length of 110 mm diameter plastic drainage pipe. The pipe needs to be held firmly in (a) (b) (c) (d) (e) Figure 5: (a) front and (b) rear of a terracotta air brick showing actual open area is less than half what it appears from the front, (c) typical cast iron vent, (d) and (e) modern plastic ventilators offering more open area than a similar-sized terracotta air brick

radon solutions for homes: improving underfloor ventilation GRG 37/1 5 Telescopic, cranked or periscopic ventilator Floor Box in and make weathertight as required Grille to allow air movement Fan wired back to fused socket Timber floor Underfloor space Void 110 mm diameter PVC-U pipe Figure 6: Section through a telescopic vent Outside Electric fan mounted to wall Seal cavity and wall around pipe Inside Figure 8: In-line duct fan with pipe fixed to a cavity wall Figure 7: Plastic vent cowl used to reduce draughts from an exterior ventilation grille in windy weather Figure 9: Boxed-in fan fitted in place of an underfloor vent place so that a fan can be attached to it. The fan can be located outside or beneath the floor of the building. If it is being installed outside then the fan itself will need to be a weather-resistant type, or the fan will need to be mounted within a weathertight box. The box can be made of any material that is suitably weathertight and can be decorated to blend in with the building (Figures 8 10). Alternatively, the fan can be located beneath the floor. The main advantage of this is that it will be hidden from view, though it is likely to increase the noise levels in the rooms above. Avoid locating inlets or exhausts close to doors or windows. When extracting air, do not install an extract fan within 1.5 m of an airbrick as it may simply draw outside air through the airbrick instead of drawing air from the underfloor space. Wall-mounted axial fan Outside Fan wired back to fused socket Timber floor Underfloor space Seal cavity and wall around pipe Inside Figure 10: Axial flow fan located within the thickness of a cavity wall

6 radon solutions for homes: improving underfloor ventilation GRG 37/1 Selecting the fan For average-sized dwellings, a single fan should be adequate. The fan should have a flow rate that can exchange the volume of air in the underfloor space between three and ten times an hour and be able to run continuously throughout the year. A fan supplier will be able to provide a suitable fan based on the estimated volume of the underfloor space and the exchange rate (3 10 air changes per hour). Typical fans will be either axial flow fans or centrifugal in-line duct fans. Either can be used although an in-line duct fan has the advantage of being able to be coupled to pipework and where necessary a silencer. A fan that will be exposed to weather should be suitably protected to level IP54 as classified in BS EN 60529:1992 [1]. If the fan does not have this level of protection it will need to be located in a waterproof housing. Fans should be wired in accordance with BS 7671:2008+A1:2011, Requirements for electrical installations, the IET Wiring Regulations [2]. Noise reduction In most cases, underfloor fans run relatively quietly but occasionally noise can be a problem. More often than not, noise is due to air movement not the running of the fan. The following advice should be considered in order to minimise noise nuisance. Position the exhaust outlet away from doors or windows, particularly ground-floor bedroom windows which may be left open at night. Consider packing insulation material around a fan that is mounted in a weathertight box. Ensure that fans installed beneath a timber floor are supported off the ground rather than fixed to the underside of the floor. Where a fan is to blow air beneath a floor, consider fitting a silencer to the system. This is particularly appropriate for manifolded systems (Figure 11). Fan manufacturers can advise on appropriate silencers. For further advice see BRE Good Building Guide 26 [3]. Additional points to consider when improving underfloor ventilation Underfloor services The impact of increasing underfloor ventilation means that the underfloor space will be colder in winter. It is advisable to seal any obvious openings through the floor, or even cover the floor with hardboard. Do not use polyethylene sheet as the timber must be able to breathe to prevent timber rot. Services routed under the floor, particularly central heating or water pipes, should be insulated to avoid the risk of freezing. Vents cut through timber floors It is common to find that vents have been cut through a suspended timber floor to provide air to a combustion appliance such as an open fire or gas appliance. Where Box in and make weathertight as required Grille to allow air movement Outside Electric fan mounted to wall Seal cavity and wall around pipe Figure 11: System fitted with silencer Fan wired back to fused socket Timber floor Underfloor space 110 mm diameter PVC-U pipe Silencer for fan Inside Ground-support for silencer this occurs, the vent should be sealed and an alternative vent provided through a wall above the floor or the vent should be ducted directly to the outside. Combustion appliances Avoid locating an extraction fan adjacent to an open-flued combustion appliance such as an open fire, gas fire or gas boiler which draws air from the room for combustion. There is a potential risk of spillage of harmful gases. If it cannot be avoided use supply ventilation (fan blowing air into the floor void), rather than extract ventilation. Multiple fans This sheet describes using a single fan to reduce radon levels. Experience has shown that using two smaller fans, one on each side of the building, can also work. Smaller fans can be easier to install, less visually obtrusive and quieter. Manifolded system In cases where there are no obvious openings between individual underfloor spaces, pipework can be connected to the fan to extend the range of ventilation under several rooms (Figure 12). Checking that the improved ventilation works and continues to work The HPA recommends that householders who have installed remedial measures to reduce radon concentrations should do a long-term (3 month) validated measurement of radon levels to ensure effectiveness. Shorter measurements (7 14 days) are not normally used and may lead to false indications because of the large day-to-day fluctuations of radon concentrations. Radon measurements should be repeated at intervals of five to ten years and after any substantial changes to the building, the way it is used or a change of occupants. Improvements such as adding an extension or conservatory, installing new double-glazed windows

radon solutions for homes: improving underfloor ventilation GRG 37/1 7 indicates why this may happen and suggests solutions to the problems. Figure 12: A manifolded system beneath three rooms fitted with a silencer close to the fan or upgrading the insulation can alter the ventilation and/ or heating patterns which could affect the indoor radon concentration. What to do if it does not work There should be a reduction in radon level in the majority of cases if the guidance given in this Good Repair Guide is followed. Occasionally, the radon concentration may not change, or it may be only slightly reduced. Table 1 maintenance Underfloor ventilation grilles should be checked at least annually, preferably in the Spring, to ensure that they have not become blocked in any way. Debris should be swept away from grilles with a hand brush. Where a fan is used for ventilation, check that it is still running, and that the air inlet or outlet has not become blocked. If it has become blocked, switch off the fan and remove the obstruction before switching the fan back on. If the fan sounds noisier than previously it may be an indication that it is wearing out. Fan manufacturers tend to advise that the life expectancy of a fan is about 5 7 years. In practice, however, fans can run for much longer. In-line duct fans have been known to run continuously for over 20 years. further information Further advice on radon risk and testing is available from the Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 0RQ. Telephone 01235 822622 Website www.ukradon.org Table 1: Troubleshooting for underfloor ventilation Problem Observation Solution Natural underfloor ventilation No change in radon level The vents appear Check that there is sufficient open ventilation as described in this or only a small reduction to be clear Good Repair Guide. If not, consider adding additional vents. Alternatively, consider installing a fan in place of one of the vents. In cases where only part of a ground floor has suspended construction the effectiveness of increased underfloor ventilation may not be that great and an alternative solution such as a sump system or a positive ventilation system that targets other areas in the house should be considered (see Part 2 of this Good Repair Guide). Mechanical underfloor ventilation No change in radon level The fan is not working Check that the fan is switched on! If it is, check that the fuse has not or only a small reduction blown. If the fuse is not at fault and the fan is still not working consult an electrician or the manufacturer. The fan is working Consider reversing the flow of the fan, ie if the fan is extracting air from the underfloor space, turn it around to blow air under the floor. Also, check that the fan is not close to an open air vent as the fan may be drawing fresh air from outside rather than radon-laden air from under the floor. If this appears to be the case consider blocking up the air vent. If there is a slight reduction in radon concentration it suggests that some dilution or change in pressure is occurring. Check that the fan size and speed setting are appropriate. Consider increasing the fan speed or fitting a more powerful fan. Radon level increases The fan is working Occasionally, radon concentrations increase when a fan is fitted. While initially disappointing, it does at least indicate that the fan is affecting the pressure balance under the floor. Consider reversing the flow of the fan (ie if the fan is extracting air from the underfloor space, turn it around to blow air under the floor). Note: After completing work to reduce radon concentrations, a 3-month validated measurement of radon levels should be conducted to ensure effectiveness.

8 radon solutions for homes: improving underfloor ventilation GRG 37/1 references [1] BSI. Specification for degrees of protection provided by enclosures (IP code). BS EN 60529:1992. London, BSI, 1992. [2] BSI. Requirements for electrical installations. IET Wiring Regulations. 17th edition. BS 7671:2008+A1:2011. London, BSI, 2008, 2011. [3] BRE. Minimising noise from domestic fan systems and fanassisted radon mitigation systems. GG 26. Bracknell, IHS BRE Press, 1996. Acknowledgements The preparation and publication of this Good Repair Guide was funded by BRE Trust and the Health Protection Agency. This Good Repair Guide has been prepared by BRE and HPA. It should be noted that BRE and HPA cannot guarantee that the measures described in this leaflet will reduce the radon level in a home. However, similar measures have frequently proved successful in a range of UK locations. Radon: Guidance on protective measures for new buildings BRE Report BR 211, 2007 edition Get practical guidance for reducing the concentration of radon in new buildings, extensions, conversions and refurbishment projects. This guide will help architects, designers, builders and installers to specify and install successful protective measures to reduce the risk of exposure to radon. The guide contains updated maps of England and Wales for identifying areas where radon protective measures should be installed. Other radon publications from BRE Radon protection for new domestic extensions and conservatories with solid concrete ground floors Good Building Guide 73 Get practical guidance on providing radon protection to new domestic extensions and conservatories and understand why it is necessary. This Good Building Guide will also help house owners and builders in radon-affected areas to determine whether protection is needed and the level of protection that is required. Radon protection for new dwellings Avoiding problems and getting it right! Good Building Guide 74 Find out how to install radon-protectiion measures in new dwellings successfully. This Good Building Guide will help designers, site managers, building control authorities and site operatives to ensure that radon-protection measures work. Radon protection for new large buildings Good Building Guide 75 Find out how to install radon-protection measures within large buildings successfully, eg laying a radon-proof barrier across a large floor area, how many sumps to install and how to construct the sump and pipework. In addition to the requirements of building regulations, a building used as a workplace has to meet the requirements of the Ionising Radiations Regulations 1999. All titles are available in print and pdf format. Good Building Guides 73 75 are available individually or as a set of three. Order now @ www.brebookshop.com or phone the IHS Sales Team on +44 (0) 1344 328038. BRE is the UK s leading centre of expertise on the built environment, construction, energy use in buildings, fire prevention and control, and risk management. BRE is a part of the BRE Group, a world leading research, consultancy, training, testing and certification organisation, delivering sustainability and innovation across the built environment and beyond. The BRE Group is wholly owned by the BRE Trust, a registered charity aiming to advance knowledge, innovation and communication in all matters concerning the built environment for the benefit of all. All BRE Group profits are passed to the BRE Trust to promote its charitable objectives. BRE is committed to providing impartial and authoritative information on all aspects of the built environment. We make every effort to ensure the accuracy and quality of information and guidance when it is published. However, we can take no responsibility for the subsequent use of this information, nor for any errors or omissions it may contain. BRE, Garston, Watford WD25 9XX Tel: 01923 664000, Email: enquiries@bre.co.uk, www.bre.co.uk Good Repair Guides are accessible guides to the defects most commonly encountered in buildings and offer sound advice on putting them right. They are highly illustrated to make the problems and solutions easy to identify and understand. Digests, Information Papers, Good Building Guides and Good Repair Guides are available on subscription in hard copy and online through BRE Connect. For more details call 01344 328038. BRE publications are available from www.brebookshop.com, or IHS BRE Press, Willoughby Road, Bracknell RG12 8FB Tel: 01344 328038, Fax: 01344 328005, Email: brepress@ihs.com Requests to copy any part of this publication should be made to: IHS BRE Press, Garston, Watford WD25 9XX Tel: 01923 664761 Email: brepress@ihs.com www.brebookshop.com GR 37, Part 1 BRE 2012 November 2012 ISBN 978-1-84806-300-6 (Part 1) ISBN 978-1-84806-303-7 (3-Part set)