2316 Grey Rd. Davidson, NC 28036 704-399-1177



Similar documents
Inspecton Report. Property Address:

Home Inspection Report

Inspection Report Atlanta Strip Mall Commercial Building Property Address:

Inspection Report. Prepared For: Sampath Sample. Property Address: Waterside Drive. Alpharetta, GA Atlanta Home Inspections

HOME INSPECTION CHECKLIST

Vision Home Inspection

Inspection Report. Mr. Happy 2 flat owner. Property Address: Focal Point Home Inspection Ltd.


Inspection Report. Mr. Sample Sample. Property Address: 1234 USA Drive Indianapolis IN USA Drive. Morris Home Inspection Group, LLC

STATE OF FLORIDA HOME INSPECTION STANDARDS OF PRACTICE:

October 5, 2015 Dear Client,

Inspection Report TPCC. Property Address: 22 Touisset Road Warren RI Lane's Perfection Inspections

I NI NP R Inspected Items

Inspection Report. Prepared For: Atlanta Commercial Customer. Property Address: xxx Sandy Plains Road. Building 5 Marietta, GA 30066

Inspection Report. Justin Anderson. JP's Home Inspection Services. Property Address: 987 Bluffs Drive Thistown Ia Jeff Peiffer th St.

Inspection Tech. (330) Inspected By: Aaron Westerburg

Inspection Report. Mr. JOHN SMITH. Property Address: S. Main St Denver Co A Happy House Home Inspection, LLC

A.C.E. Home Inspection Service St. Peters, MO (636)

PROPERTY INSPECTION REPORT

South Carolina Home Inspector Standards of Practice

Inspection Report. Mr. John Homebuyer. Property Address: 123 Main Street Houston TX Front View. EDP Consulting Engineers, PLLC

License Requirements for Persons Engaging in the Business of Inspection Practice:

HOME INSPECTION REPORT

Inspection Report Mr. Sample Customer Property Address:

Total Home Inspection Checklist

Crawford Inspection Services C.C.B. #

Inspection Report. Dream Home Inspections Second Ave. Frisco CO (970)

Inspection Report. Jacksonville Krystals Inspection. Property Address: Downtown. Jacksonville FL South East Building Consultants

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

BUILDING ANALYSIS REPORT. John Doe 1234 Smith Road Atlanta, Georgia 30396

Self-Home Inspection Checklist

Summary of Oregon Home Inspector Certification Law and Standards of Practice for Home Inspections

Accurate Home Inspection of Illinois. Property Inspection Report For Steve & Jenny Hynek 210 W.Chicago Ave., Westmont, Illinois

CHRIS CURLES and ASSOCIATES INSPECTION SERVICES

South Carolina Home Inspector Standards of Practice

Inspection Item COMMENTS

Vari Inspection Services

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

PROPERTY INSPECTION REPORT Property Address:

Home Inspection Report

Inspection Report. Mr. Simon Praveet. Property Address: 6643 Report Road Cincinnati OH Gerard Home Inspection

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

Inspection Report. sample sample. Property Address: 333 Wild Rasberry Lane. Etowah NC. Hubert Lowe Home Inspections

Propery Inspection Report

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

159 Morningside Avenue, Toronto

BUILDING DEPARTMENT 8748 W. 82 nd Place - Justice, IL Phone: (708) Fax: (708)

Inspection Report. Property Address: St. Marks Ave. Brooklyn NY Five Borough Home Inspection, LLC. Derek Lomer

SECTION NC HOME INSPECTOR STANDARDS OF PRACTICE AND CODE OF ETHICS

Home Inspection Report

HOME INSPECTOR STANDARDS OF PRACTICE

COMPREHENSIVE PROPERTY INSPECTIONS

PROPERTY INSPECTION REPORT

Inspection Report. provided by: Delaware Property Inspection. Inspector: Richard Hiddemen (302)

PROPERTY INSPECTION REPORT

A comfortable house is a great source of happiness. - Sydney Smith. Home Maintenance Guide

Inspection Report. Joe and Sue Smith. Property Address: 1234 Your St. Bothell WA Transparent Inspections

Home Inspection Report

Building Condition Assessment Report

Inspection Report 95 Old Stage Road East Brunswick NJ Scott Frederick

Inspection Report. Prepared Exclusively For:Joe Sample. Property Address: 552 Brindway. Raleigh NC

Orlando Home Inspection Services

Quality Home Inspections, LLC 4433 Tennyson Street Denver, Colorado

Home. Safe. Home. home inspection report

Inspection Report. Mr. John Doe. Property Address: 123 Somewhere Jacksonville FL Tabor Hill & Associates LLC

BOROUGH OF NATIONAL PARK APPLICATION FOR A CERTIFICATE OF OCCUPANCY FOR CHANGE OF OCCUPANCY ADDRESS OF PROPERTY FOR INSPECTION CURRENT OWNER

ASHI STANDARD OF PROFESSIONAL PRACTICE FOR HOME INSPECTIONS

Georgia Home Inspection Services

Inspection Report. Sample Client. Property Address: XXXX N. Atolia Drive Tucson AZ House and Home

PROPERTY INSPECTION REPORT

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Home Systems Data Inc E. Peakview Ave. Centennial CO

Terry Jenkins, Owner Member, American Society of Home Inspectors Virginia Certified Home Inspector Certificate # , expires 1/2010

Inspecting to a higher standard.

Home Inspection Report

Inspection Report. Sample Report. Property Address: 1234 Anywhere street Phoenix AZ. Veteran Inspection Professionals

GeorgiaHomePros.com Yellow Creek Road Ball Ground, GA Inspected By: Scott Webb

Inspection Report. "Even small homes, could have big problems"

Inspection Report. Joe Smith Report. Property Address: 111 Main Street St Augustine FL Eagle Eye Home Inspections

Inspection Report. Ms. Onah Holmes 123 Maple Street Springfield, Ontario

A and S Property Inspector

Inspection Report. Joe Smith. Property Address: 2222 SW 20 St Miramar FL Coast to Coast Property Inspections

Pre-Drywall Inspection Report

HEDDERMAN ENGINEERING, INC Carrie Cove Ct., Spring, TX , fax

GUARDIAN HOME 26 EAST MADISON AVENUE CRESSKILL, NEW JERSEY (201) (201) FAX

First Flight Home Inspections, Inc.

OC Home Inspect. 333 S Crest Rd Orange, CA (714) guybrianadams@gmail.com Inspected By: Brian Adams

INVOICE. DATE: May 11, DESCRIPTION Inspection and report on a property located at OF SERVICES: Perfect Street, Sarasota, Fl.

Home Inspection Report

Inspection Report. Bob and Betty Buyer. Property Address: 4567 Home street Anchorage AK Inspection Connection LLC

BUILDING INSPECTION REPORT

RRIO Checklist. Use of checklist: Definitions: Limitations

SWF Home Inspections

New Jersey Property Inspections LLC NJ State Home Inspector License # 24GI Neshanic Drive, Ringoes NJ /

HOMEOWNER S PERMIT GUIDE

HAPPY HOMEBUYER Somewhere St. Arland, Texas, This report was created exclusively for

Simplify. Homeownership

WILL INSPECT: (A) INSTALLED AND ACCESSIBLE SYSTEMS AND COMPONENTS OF HOMES LISTED IN THESE INSPECTOR STANDARDS. INSPECTORS WILL REPORT

Transcription:

2316 Grey Rd. Davidson, NC 28036 704-399-1177 Customer Sample Report Home 567 Best Place I Could Find Waxhaw, NC 28173 Real Estate Agent Report ID: 318081 Inspection Date 3/18/2008 Inspected By Keven H. Kossler NC #17 SC #44 Castle Check, LLC page 1 of 27

2316 Grey Rd. Davidson, NC 28036 704-399-1177 INVOICE Customer: Sample Report Location: 567 Best Place I Could Find Waxhaw, NC 28173 Inspection Date: 3/18/2008 Report ID: 318081 Real Estate Agent: Inspection Fee: Service Price Amount Sub-Total Home Inspection 375.00 1 375.00 Tax $0.00 Total Price $375.00 Payment Status:Paid Note: Payment of this invoice is due upon receipt. The late payment charge rate of interest is 1.5% monthly (18% per annum), with a minimum late fee of $ 25.00 after 30 days. Fee on all returned checks is $35.00. Castle Check, LLC page 2 of 27

Home Inspection Agreement, Please read carefully. CLIENT: Sample Report ADDRESS: 123 Great Place St. CITY, STATE, ZIP: Charlotte, NC 28227 PHONE: 555-555-5555 INSPECTION 567 Best Place I Could Find, Waxhaw, NC 28173 ADDRESS: DATE: 3/18/2008 TIME: 09:30 AM 1. This inspection is performed by Castle Check, LLC. in accordance with the American Society of Home Inspectors (ASHI), the North Carolina Home Inspectors Licensure Board & South Carolina LLR Standards Of Practice and Code of Ethics. The use of these Standards are intended to provide the Client with a better understanding of the property conditions, as observed at the time of inspection. Inspections done in accordance with these Standards are visual and are not technically exhaustive. These Standards are applicable to buildings with four or less dwelling units and their attached garages or carports. 2. The Inspector is not required to move furniture, personal items, equipment, insulation, or enter un-floored attic areas, evaluate the condition or presence of storm windows / doors / screens / storm shutters, awnings or any other seasonal accessories, or determine their functional efficiency. The operational capacity, quality, or suitability for a particular use of the items inspected as well as design problems and adequacies are not within the scope of this inspection report. Intercoms, security systems, built-in vacuums, lawn sprinklers, internal furnace combustion systems, fuel/oil tanks and water conditioning equipment are not inspected or evaluated. No destructive or disruptive testing procedures are performed by the Inspector. 3. Soil conditions, geological stability, infestation inspections, cosmetics, or engineering analysis are beyond the scope and purpose of this inspection. The inspection is not a compliance inspection or certificate for past or present government or local codes or regulations, or the suitability of the property for any specialized use. Determining the presence or absence of radon gas, carbon monoxide, safety glass, lead paint or any suspected hazardous substance, including but not limited to toxins, carcinogens, molds, mildew, fungi, noise, contaminants in soil, well, and air are beyond the scope of this inspection. 4. The inspection and report are furnished on an opinion only basis, it is not intended to be used as a Guarantee or Warranty expressed or implied. The Client agrees to perform a Walk Through using provided Walk Through Pre-Settlement Inspection Checklist. I waive all claims against the Inspector / Company in the absence of diligently performing my Walk Through Pre-Settlement Inspection and for lack of more extensive investigation and follow through with a specialist on any problems noted including conformation of any cost to cure. 5. If I make a claim against the Inspector / Company for an alleged error, omission or other act arising out of this inspection report and fail to prove such claim, I will pay all attorney's fees, arbitrator's fees, legal expenses and costs incurred by the Inspector / Company in the defense of the claim. Any disputes other than related to payment for services rendered pursuant to this agreement, shall be submitted to binding, non-appealable arbitration administered by a Licensed Home Inspector with at least 6 years experience, unless the parties mutually agree otherwise, in writing. 6. This inspection is not for third party use. I request this inspection / report, for my confidential use only. By my release of this report, I indemnify and hold harmless the Inspector / Company for any damages claimed by others. 7. Approximate cost to cure for repairs are to be used as a guide only, Actual Repair Costs Should Be Determined Prior To Settlement. 8. Castle Check is authorized to release a copy of the report and disclose information within this home inspection report to my Realtor, for the purpose of clarification and facilitation of repairs. Home inspection reports will be shipped / delivered within three business days from the date of the final / completed inspection. 9. This inspection includes the structure, foundation, electrical, roof, plumbing, HVAC, interior, and built-in appliances. Base Home Inspection Total Fee $ See Invoice Standard Limited Visual Inspection: Payment in full should accompany this contract. If for any reason I do not purchase the above listed property, payment must be received no later than 15 days from the date of inspection. Cancellation fee ($ 100.00) if less than 24 hours notice. The Client agrees and understands that the maximum liability incurred by the Inspector / Company for errors and omissions in this inspection shall be limited to the amount paid for the inspection. I the undersigned have read and accept this contract and fee. Castle Check may have an affiliation with third-party service providers ("TPSP") in order to offer value-added services to its Clients. The company may also arrange for these TPSP to send literature or make post-inspection contact with the Company's Clients. Castle Check, LLC page 3 of 27

Client s Signature: Signature on file in officex Date: X Inspector s Signature: Signature on file in office NCHIL # : 17SCHIL # : 44 Date: Keven H. Kossler 2316 Grey Rd. Davidson, NC 28036 Office (704) 399-1177 Regional Office Fax: 1-866-768-2906 Castle Check, LLC page 4 of 27

Date: 3/18/2008 Time: 09:30 AM Report ID: 318081 Property: 567 Best Place I Could Find Waxhaw, NC 28173 Customer: Sample Report Real Estate Professional: We recommend that all new structures be monitored for the first several years to make sure there is no abnormal and or differential settlement that may cause structural concerns. We also recommend that the structure be reinspected prior to the end of the builder's warranty. BASIC PREMISE OF A HOME INSPECTION The purpose of a home inspection is to find out if there are any MAJOR problems with any of the structural or mechanical systems of the home, which could significantly affect the value of the property. As your inspector goes through his procedure to discover any major problems, he will uncover many minor problems. We make no claim we can find all the minor problems, but all those we observe will be on the report, whether major or minor. The purpose of the home inspection is NOT to identify each and every maintenance task. Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, microbial type growth, fungi, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property. The inspection performed is a visual inspection only and does not contemplate or involve the dismantling or moving of any object, furnishings or portion of the premises. Latent and concealed defects and deficiencies are excluded from the inspection. THIS INSPECTION AND REPORT IS NOT A WARRANTY, GUARANTEE, INSURANCE POLICY OR SUBSTITUTE FOR ANY DISCLOSURE STATEMENT WHETHER OR NOT IT IS REQUIRED BY LAW. Client Is Present: Yes House Status: Vacant Age Of Home: New Construction 2007 Radon Test: Yes Castle Check, LLC page 5 of 27

1. PROPERTY OVERVIEW AND WEATHER CONDITIONS Thank you for choosing Castle Check, LLC. to perform your home inspection. Please read all pages of this inspection report carefully. This inspection is visual only. A representative sample of components are reviewed in areas that are readily accessible at the time of inspection. No destructive testing or dismantling of systems, fixtures or components is performed. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. 1.0 WEATHER CONDITIONS X 1.1 TEMPERATURE X 1.2 RECENT WEATHER X 1.3 SCOPE OF INSPECTION X 1.4 SUBJECT PROPERTY PROSPECTIVE X 1.5 INSPECTION LIMITATIONS X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 1.0 The weather at the time of inspection was overcast. 1.1 The outside temperature was approximately 50-60 degrees. 1.2 Weather conditions within the past several days was relatively dry. 1.3 This was a visual structural and mechanical inspection only. 1.4 The house and structure are above average construction. I NI NP R 1.5 The home inspection was limited, one or more areas were not accessible due to the following conditions; Areas of the attic and roof/ceiling structure/framing could not be inspected/viewed due to the presence of insulation covering components, structural members and or lack of flooring. The crawl space substructure/framing at, around, above and behind the floor system insulation could not be inspected/viewed due to the presence of installed insulation, plumbing pipes, drain lines, duct work and or mechanical equipment. I NI NP R Castle Check, LLC page 6 of 27

2. GROUNDS Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials DRIVEWAY: 2.0 DRIVEWAY X CONCRETE SIDEWALKS/STOOPS/STEPS: 2.1 SIDEWALK, STOOPS AND STEPS X CONCRETE 2.2 DECKS, PATIOS, PORCHES AND APPLICABLE RAILINGS X BRICK 2.3 GRADING, DRAINAGE AND VEGETATION (With respect to their effect on the condition of the building) I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 2.2 The rear deck band/structural support ledger is not attached properly to the wall or band of home, safety concern. 2.3 The grading is sloped towards front of structure. These areas do not allow water to drain freely away from home/foundation. The grading needs to promote positive drainage away from the structure/foundation and should slope down away from the foundation (6 inches per 10 feet, 6" per 6' UBC). I X NI NP R DECKS/PORCHES: WOOD Castle Check, LLC page 7 of 27

3. FOUNDATION Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials FLOOR STRUCTURE: 3.0 FOUNDATIONS X WOOD JOISTS PLYWOOD DECKING 3.1 COLUMNS OR PIERS X 3.2 BEAMS, JOISTS, AND FLOORS (Structural) X 3.3 FOUNDATION VENTILATION X 3.4 FOUNDATION VAPOR RETARDERS X 3.5 WATER ENTRY (Report signs of abnormal or harmful water penetration into foundation areas.) 3.6 WOOD DETERIORATION X 3.7 SUMP PUMP X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 3.0 All organic and or inorganic type debris on ground in crawl space needs to be removed. 3.1 The blocking between the top of the pier(s) and the wooden structure beams and or floor joists at one or more support piers at various throughout the crawl space are not installed properly (not weight baring). 3.2 The floor joists have been cut through/compromised under master bathroom by a tradesman so as to install a plumbing supply and or drain line. This is typically an easy repair. 3.3 Foundation vent(s) are below ground/grade level at front of home and may allow moisture/water to enter into crawl space. 3.4 The crawl space vapor barrier (plastic) is soiled, wet, missing and or deteriorated in areas. I X NI NP R FOUNDATION: CRAWL SPACE BRICK/BLOCK COLUMNS OR PIERS: BRICK & BLOCK PIERS FOUNDATION VENTILATION: SILL VENTS CRAWL SPACE ENTRY DOOR: REAR WOOD METHOD USED TO OBSERVE CRAWLSPACE: WALKED/CRAWLED 3.4 Picture 1 3.5 Evidence of water/moisture present inside the crawl space foundation area. The crawl space ground is wet with some areas of standing water. This water/moisture entry needs to be eliminated to reduce dampness in the structure/foundation that may lead to premature deterioration of the building components. 3.6 Monitor: Minor wood deterioration from moisture and or insects was observed, this deterioration is typical and no major repairs appear to be needed at this time. Castle Check, LLC page 8 of 27

4. EXTERIOR Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Garage door safety tips: The garage door is the largest moving object in the home. Operation of the safety mechanisms should be verified monthly. Switches for door openers should be located as high as practical to prevent children from playing with the door. Children should be warned of the potential risk of injury. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials SIDING/WALL CLADDING: 4.0 SIDING/WALL CLADDING X BRICK TRIM/SOFFIT/FASCIA 4.1 EXTERIOR FLASHING AND TRIM X MATERIALS: 4.2 EAVES, SOFFITS, AND FASCIAS X WOOD WALL STRUCTURE: 4.3 WALLS (Structural) X WOOD FRAMING 4.4 DOORS (Exterior, representative number) X 4.5 WINDOWS (Exterior, representative number) X 4.6 GARAGE DOOR(S) X 4.7 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) 4.8 GARAGE WALLS AND CEILING (Report whether or not fire rated materials are installed on separation walls, safety concern.) I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 4.3 The condition of walls, ceilings and floor structures and other components concealed by finish materials such as but not limited to siding, drywall, floor coverings and or cabinets cannot be determined and are specifically excluded from the inspection and report. 4.4 Minor Repair: The front main entry door door binds in its frame and does not operate/close properly, this is typically a minor adjustment/repair. 4.7 The garage door opener is connected to the electric outlet using an extension cord as permanent wiring, the opener should be connected directly into the electric outlet. Exterior components that can become weathered/moisture damaged/compromised by the weather such as siding, fascias, soffits, doors, windows and trim need to be monitored on a continual monthly basis. Moisture damage can occur or become visible very fast, sometimes a compromised area that was not visible one month will be visible the next. Caulking, paint and sealant needs to be kept in good condition on an ongoing basis. The condition of walls, ceilings and floor structures and other components concealed by finish materials such as but not limited to siding, drywall, floor coverings and or cabinets cannot be determined and are specifically excluded from the inspection and report. X I X NI NP R EXTERIOR ENTRY DOORS: WOOD METAL WINDOW TYPES: WOOD THERMAL/INSULATED GARAGE DOOR MATERIAL: WOOD OPENER MANUFACTURER: OVERHEAD DOOR TYPE: TWO AUTOMATIC Castle Check, LLC page 9 of 27

5. ROOF Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: The report is not intended to be conclusive regarding the life span of the roofing system or how long it will remain watertight in the future. The inspection and report are based on visible and apparent conditions at the time of the inspection. Unless rain has fallen just prior to the inspection, it may not be possible to determine if active leakage is occurring. Not all attic areas are readily accessible for inspection. Conclusions made by the inspector do not constitute a warranty, guaranty, or policy of insurance. The client is advised to ask the seller about the presence of any roof leaks. Any repairs needed should be carried out by properly qualified Tradesman. All roofs require periodic maintenance to achieve typical life spans and should be inspected annually. Expect to make minor repairs to any roof on a periodic basis. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials ROOF-TYPE: 5.0 ROOF COVERINGS X GABLE HIP 5.1 ATTIC VENTILATION X 5.2 FLASHINGS AND ROOF PENETRATIONS X 5.3 WATER/MOISTURE ENTRY (Report signs of abnormal or harmful water/moisture penetration into the attic area.) 5.4 ROOFING DRAINAGE SYSTEMS X 5.5 ROOF (structure) X 5.6 CEILINGS (structural) X 5.7 ATTIC ACCESS X 5.8 SKYLIGHTS X 5.9 CHIMNEYS AND FLUES X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 5.0 Minor Repair: The roof ridge shingles at right side of main roof are split/damaged. This is typically an easy repair using common industry standards. 5.4 Minor Repair: The roof rain gutter down spouts at front need to be extended so as to direct water away from the foundation/structure. 5.5 Minor Repair: Wood truss(s) at/near above front porch area area has been cut through. Recommend repair by a properly qualified Tradesman. The repairs should be designed and certified by a properly licensed Structural Engineer. This condition is typically an easy repair. 5.7 Minor Repair: The pull down attic access stairs should have proper screws installed at hinge-mounts and other areas as per manufacturers specifications. This is typically an easy repair. Interior sections of the fireplaces and chimney flues can not be properly observed/inspected and are beyond the scope of a home inspection. We recommend that all chimney and flue interior have further observation/investigation with a chim Scan type camera by a properly certified chimney sweep. X I NI NP R ROOF COVERING: 5-TAB FIBERGLASS ARCHITECTURAL ROOF STRUCTURE: ENGINERED WOOD TRUSSES OSB TYPE PLYWOOD CEILING STRUCTURE: ENGINEERED WOOD TRUSSES ATTIC VENTILATION: RIDGE VENTS SOFFIT VENTS ATTIC ACCESS: HALLWAY PULL DOWN STAIRS SKY LIGHT (S): THREE FIXED GLASS WITH VENT FLAP CHIMNEY (exterior): BRICK VIEWED ROOF COVERING FROM: GROUND WITH BINOCULARS WINDOWS Castle Check, LLC page 10 of 27

6. PLUMBING Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Wells, septic systems, sewer lines, and water treatment equipment are not inspected and are specifically excluded from the inspection and report. If a well is present, it is recommended that well water be tested. No water testing of any type was performed. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials WATER SOURCE: 6.0 MAIN WATER SHUT-OFF DEVICE (Describe location) X PUBLIC PLUMBING SUPPLY: 6.1 WATER SUPPLY AND DISTRIBUTION SYSTEMS (Interior visible piping) X PLASTIC 6.2 DRAIN, WASTE, AND VENT SYSTEMS (Interior visible piping) X 6.3 WATER HEATERS, CONTROLS, CHIMNEYS, FLUES, AND VENTS X 6.4 SINKS, FIXTURES AND TOILETS X 6.5 SHOWER/TUB TILE WALLS X 6.6 BATHROOM VENTILATION X 6.7 HOSE FAUCETS X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 6.0 The main water shut-off is the lever located in garage beside water heater (For your info). I NI NP R DISTRIBUTION: PLASTIC COPPER PLUMBING WASTE: PVC MANUFACTURER: A.O. SMITH WATER HEATER POWER SOURCE: GAS CAPACITY: 65 GALLON 6.0 Picture 1 6.3 (1) The water heaters T&P valve is leaking. 6.3 Picture 1 6.3 Picture 2 Castle Check, LLC page 11 of 27

(2) View of water heater(s) in garage (for your info). 6.3 Picture 3 6.4 Minor Repair: The toilet in the master bathroom is loose from the floor and it is stopped up. 6.4 Picture 1 6.5 Minor Repair: Caulking/sealant is needed at/around the bathroom tub and or shower joints in the master bathroom. This is typically an easy repair. 6.6 Bathroom exhaust fan in the upstairs hall bathroom did not function when tested. The plumbing in the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waiting for closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified Tradesman be used in your further inspection or repair issues as it relates to the comments in this inspection report. Be aware of the risk of scalding from water temperatures above 120 F. The risk is especially acute for infants, children, and the elderly. Water heater temperatures should never be set higher than 120 F. Note that higher water temperatures are not necessary for modern dishwashers which heat the water. Water filtration units are not tested/inspected. Castle Check, LLC page 12 of 27

7. ELECTRICAL Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Smoke and carbon monoxide detectors should be installed (if not already present) on each floor (including attics and basements) and outside all sleeping areas. Consult the manufacturer's literature for recommended mounting locations. Be sure to test your smoke detectors upon moving in and monthly thereafter. Electrical systems require regular maintenance for safety reasons. Annual inspection and maintenance of the system by a licensed electrician is recommended. The inspection does not include low voltage systems, telephone wiring, intercoms, alarm systems, cable TV wiring or timers. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials ELECTRICAL CONDUCTORS: 7.0 SERVICE ENTRANCE CONDUCTORS X BELOW GROUND ALUMINUM 7.1 LOCATION OF MAIN AND DISTRIBUTION PANELS X 110/220 VOLTS 7.2 SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN, AND DISTRIBUTION PANELS 7.3 BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE 7.4 OUTLETS, SWITCHES AND FIXTURES (Observed from a representative number; operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) 7.5 SMOKE DETECTORS X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 7.1 Main electric panel box is located in the garage, and the main turn off breaker is located in the box next to the meter base. (for your info). X X I X NI NP R SERVICE GROUND: GROUND ROD PANEL TYPE: CIRCUITS BREAKERS PANEL CAPACITY: 200 AMP ELEC. PANEL MANUFACTURER: CUTLER HAMMER BRANCH WIRE 15 and 20 AMP: COPPER WIRING METHODS: ROMEX RECEPTACLE TYPE: 3 PRONG OUTLETS GFCI'S OUTLETS 7.4 (1) The GFCI electric outlet in the kitchen did not trip off when tested. This is typically an easy repair. (2) The door bell switch is broken. 7.1 Picture 1 7.1 Picture 2 Castle Check, LLC page 13 of 27

7.4 Picture 1 The electrical system of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Outlets were not removed and the inspection was only visual. Any outlet not accessible (behind a refrigerator, appliance, storage and or furniture for example) was not inspected or accessible. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified Tradesman be used in your further inspection or repair issues as it relates to the comments in this inspection report. If the house does not have smoke and carbon monoxide detector(s) installed or the present detector(s) appear old/dated, we recommend the installation of new detector(s). Castle Check, LLC page 14 of 27

8. HEATING Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Note: The report should not be read as a prediction of the remaining life span of the Air Conditioning/Heating System. Typical life spans of equipment may range from 8-12 years, but there are many exceptions to this. Most air conditioning compressors are warranted for only 5 years. Replacement of a compressor alone may cost from $600-$800 or more. We recommend that you purchase a home warranty or service contract to cover replacement or repair. Be advised that defects or failure can occur at any time, and that the inspection in no way lessens the risk or likelihood of repairs or replacements being needed at any time in the future, including the day after the inspection. Any mechanical equipment can fail without warning at any time. It is recommended that all equipment be serviced twice a year. Regular service is very important for efficient operation and to achieve maximum life span. Filters should be changed monthly. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials HEAT TYPE: 8.0 HEATING EQUIPMENT X FORCED AIR 8.1 HEAT DISTRIBUTION SYSTEMS (Ductwork, air flow, air filters, and registers) 8.2 CHIMNEYS, FLUES, AND VENTS X 8.3 NORMAL OPERATING CONTROLS X 8.4 AUTOMATIC SAFETY CONTROLS (Observed, not tested/operated) X 8.5 PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM X 8.6 SOLID FUEL HEATING DEVICES X 8.7 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 8.0 View of heating/cooling system air handler(s) in crawl space and attic (for your info). X X I NI NP R ENERGY SOURCE: GAS NUMBER OF HEAT SYSTEMS (excluding wood): TWO DUCTWORK: FLEX DUCT SHEET METAL INSULATED CHIMNEYS/FLUES: PLASTIC FILTER TYPE: DISPOSABLE 8.0 Picture 1 8.0 Picture 2 The heating/cooling system(s) were visually inspected and reported on. The inspection is not meant to be technically exhaustive and the inspector/company does not open/dismantle heating/cooling system(s). The inspection does not involve removal and inspection behind service doors and or dismantling that would otherwise reveal something only a licensed/qualified heat/cooling contractor would discover. We recommend having all heating/cooling system(s) internal and combustion components and humidifiers checked, serviced and cleaned by a properly qualified heating/cooling Tradesman. Castle Check, LLC page 15 of 27

9. AIR CONDITIONING Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Note: The report should not be read as a prediction of the remaining life span of the Air Conditioning/Heating System. Typical life spans of equipment may range from 8-12 years, but there are many exceptions to this. Most air conditioning compressors are warranted for only 5 years. Replacement of a compressor alone may cost from $600-$800 or more. We recommend that you purchase a home warranty or service type contract to cover replacement or repair. Be advised that defects or failure can occur at any time, and that the inspection in no way lessens the risk or likelihood of repairs or replacements being needed at any time in the future, including the day after the inspection. Any mechanical equipment can fail without warning at any time. It is recommended that all equipment be serviced twice a year. Regular service is very important for efficient operation and to achieve maximum life span. Filters should be changed monthly. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials COOLING EQUIPMENT TYPE: 9.0 COOLING AND AIR HANDLER EQUIPMENT X CENTRAL AIR 9.1 COOLING AND AIR HANDLER EQUIPMENT X 9.2 TEMPERATURE DIFFERENTIAL (TD, is the difference between the intake air temp. and the output air temp. ideally 14-22 degrees) 9.3 NORMAL OPERATING CONTROLS X 9.4 DISTRIBUTION SYSTEMS (Ductwork, air flow, air filters, and registers) X 9.5 PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 9.0 View of cooling system outside condenser(s) (for your info). X I NI NP R DUCTWORK: FLEX DUCT SHEET METAL INSULATED COOLING EQUIPMENT ENERGY SOURCE: ELECTRICITY NUMBER OF A/C UNITS: TWO 9.0 Picture 1 9.1 (1) The insulation on the refrigerant line(s) is missing, damaged, or deteriorated at one or more areas. It is important that the refrigerant line be well insulated all the way from the condenser unit to the evaporator unit to prevent condensation and to increase cooling efficiency. Castle Check, LLC page 16 of 27

9.1 Picture 1 (2) Evidence of abnormal moisture conditions (water, rust and water stains) present in over flow pan under air handler unit located in attic. This is a typical indication of the air handler, refrigerant lines and or A-coil leaking and or not draining properly, also the condensation drain piping maybe clogged. 9.1 Picture 2 The cooling system(s) were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed/qualified HVAC contractor would discover (Heating, Ventilation, and Air Conditioning). We recommend having all heating/cooling system(s) internal and combustion components and humidifiers checked, serviced and cleaned by a properly qualified heating/cooling Tradesman. Castle Check, LLC page 17 of 27

10. INTERIORS Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Minor cracks are found on interior surfaces in all buildings and are typically cosmetic in nature. This type of cracking is usually caused by settlement, separating tape joints and/or shrinkage of building components. Small cracks of this type are not mentioned in the report. The condition of floors underneath carpet and other coverings cannot be determined and is specifically excluded from the inspection and report. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials CEILING MATERIALS: 10.0 CEILINGS X DRYWALL WALL MATERIAL: 10.1 WALLS X DRYWALL 10.2 FLOORS X 10.3 DOORS (Representative number) X 10.4 STEPS, STAIRWAYS, AND RAILINGS X 10.5 CABINETS AND COUNTER TOPS (Representative number) X 10.6 FIREPLACES X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace I NI NP R FLOOR COVERING(S): CARPET HARDWOOD TILE INTERIOR DOORS: RAISED PANEL CABINETRY: WOOD COUNTERTOPS: GRANITE FIREPLACE: MASONRY/BRICK GAS/LP LOGS OPERABLE FIREPLACES: ONE The interior of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection did not involve moving furniture, storage and or inspecting behind furniture, storage, under area rugs, appliances or other areas obstructed from view. Castle Check, LLC page 18 of 27

11. INSULATION AND VENTILATION Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials ATTIC INSULATION: 11.0 ATTIC INSULATION X BLOWN BATT 11.1 FLOOR INSULATION X FIBERGLASS 11.2 WALL INSULATION X 11.3 VENTING SYSTEMS (Kitchens and laundry) X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 11.0 The attic pull down stairs insulation is missing, it is easy to add this insulation and it will improve the efficiency of the heating/cooling system(s). 11.2 Walls are covered by finish materials, we could not determine/inspect presence of insulation. The insulation and ventilation of the home was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Venting of exhaust fans or clothes dryer cannot be fully inspected and bends or obstructions can occur without being accessible or visible (behind walls, floors and ceiling coverings). Only ventilation and insulation that is readily visible was inspected. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified Tradesman be used in your further inspection or repair issues as it relates to the comments in this inspection report. I NI NP R FLOOR INSULATION: BATT FIBERGLASS WALL INSULATION: UNKNOWN R- VALUE: TYPICAL FOR THIS AGE HOUSE DRYER POWER SOURCE: 22O ELECTRIC DRYER VENT: FLEXIBLE METAL METAL Castle Check, LLC page 19 of 27

12. BUILT-IN KITCHEN APPLIANCES Castle Check, LLC performed this inspection according to the ASHI, North Carolina and South Carolina Standards of Practices and Code of Ethics: Permanently attached/built in appliances are tested by turning them on briefly. Extensive testing of timers, thermostats, and other controls is not performed. No report is made regarding the effectiveness of any appliances. The inspection only determines whether or not the appliances run. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. I NI NP R Styles & Materials DISHWASHER: 12.0 DISHWASHER X GENERAL ELECTRIC DISPOSER: 12.1 SINK WASTE DISPOSER X IN SINK ERATOR 12.2 RANGE HOOD X 12.3 RANGES, OVENS, AND COOKTOPS X 12.4 MICROWAVE COOKING EQUIPMENT X 12.5 TRASH COMPACTOR X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace I NI NP R EXHAUST/RANGE HOOD: GENERAL ELECTRIC RANGE/OVEN: GENERAL ELECTRIC COOK TOP: GENERAL ELECTRIC BUILT-IN MICROWAVE: GENERAL ELECTRIC The built-in appliances of the home were inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. It is recommended that qualified Tradesman be used in your further inspection or repair issues as it relates to the comments in this inspection report. Castle Check, LLC page 20 of 27

13. COMPLIMENTARY PHOTO VIEWS 13.0 ATTIC VIEW X 13.1 KITCHEN VIEW X 13.2 DINING ROOM VIEW X 13.3 LIVING ROOM VIEW X 13.4 DEN VIEW X I=Inspected/Monitor, NI=Not Inspected, NP=Not Present, R=Not Functioning or in Need of Repair/Replace Comments: 13.0 View of Attic I NI NP R I NI NP R 13.1 Kitchen View 13.0 Picture 1 13.2 Dining Room View 13.1 Picture 1 Castle Check, LLC page 21 of 27

13.3 Living Room View 13.2 Picture 1 13.2 Picture 2 13.4 Den View 13.3 Picture 1 13.4 Picture 1 Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2007 : Licensed To Castle Check, LLC Castle Check, LLC page 22 of 27

General Summary Castle Check, LLC 2316 Grey Rd. Davidson, NC 28036 704-399-1177 Customer Sample Report Property Address 567 Best Place I Could Find Waxhaw, NC 28173 The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or appear to warrant further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home. It is recommended that any deficiencies and the components/systems related to these deficiencies noted in the report/summary be further evaluated/reviewed and repaired as deemed appropriate by the properly qualified or licensed tradesman/contractor/professional prior to closing. Further evaluation prior to closing is recommended so that the properly qualified or licensed professional can evaluate/review our concerns further and evaluate the entire remainder of deficient system, fixture, appliance and or component for additional concerns that may be outside the scope of our home inspection and have repairs made as deemed appropriate prior to closing. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. NOTE: Please refer to your real estate contract for options, terms or considerations of any discoveries noted in this report. 2. GROUNDS 2.2 DECKS, PATIOS, PORCHES AND APPLICABLE RAILINGS The rear deck band/structural support ledger is not attached properly to the wall or band of home, safety concern. 2.3 GRADING, DRAINAGE AND VEGETATION (With respect to their effect on the condition of the building) The grading is sloped towards front of structure. These areas do not allow water to drain freely away from home/foundation. The grading needs to promote positive drainage away from the structure/foundation and should slope down away from the foundation (6 inches per 10 feet, 6" per 6' UBC). Castle Check, LLC page 23 of 27

3. FOUNDATION 3.0 FOUNDATIONS All organic and or inorganic type debris on ground in crawl space needs to be removed. 3.1 COLUMNS OR PIERS The blocking between the top of the pier(s) and the wooden structure beams and or floor joists at one or more support piers at various throughout the crawl space are not installed properly (not weight baring). 3.2 BEAMS, JOISTS, AND FLOORS (Structural) The floor joists have been cut through/compromised under master bathroom by a tradesman so as to install a plumbing supply and or drain line. This is typically an easy repair. 3.3 FOUNDATION VENTILATION Foundation vent(s) are below ground/grade level at front of home and may allow moisture/water to enter into crawl space. 3.4 FOUNDATION VAPOR RETARDERS The crawl space vapor barrier (plastic) is soiled, wet, missing and or deteriorated in areas. 3.4 Picture 1 3.5 WATER ENTRY (Report signs of abnormal or harmful water penetration into foundation areas.) Evidence of water/moisture present inside the crawl space foundation area. The crawl space ground is wet with some areas of standing water. This water/moisture entry needs to be eliminated to reduce dampness in the structure/foundation that may lead to premature deterioration of the building components. 4. EXTERIOR 4.4 DOORS (Exterior, representative number) Minor Repair: The front main entry door door binds in its frame and does not operate/close properly, this is typically a minor adjustment/repair. 4.7 GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) Castle Check, LLC page 24 of 27

4. EXTERIOR The garage door opener is connected to the electric outlet using an extension cord as permanent wiring, the opener should be connected directly into the electric outlet. 5. ROOF 5.0 ROOF COVERINGS Minor Repair: The roof ridge shingles at right side of main roof are split/damaged. This is typically an easy repair using common industry standards. 5.4 ROOFING DRAINAGE SYSTEMS Minor Repair: The roof rain gutter down spouts at front need to be extended so as to direct water away from the foundation/structure. 5.5 ROOF (structure) Minor Repair: Wood truss(s) at/near above front porch area area has been cut through. Recommend repair by a properly qualified Tradesman. The repairs should be designed and certified by a properly licensed Structural Engineer. This condition is typically an easy repair. 5.7 ATTIC ACCESS Minor Repair: The pull down attic access stairs should have proper screws installed at hinge-mounts and other areas as per manufacturers specifications. This is typically an easy repair. 6. PLUMBING 6.3 WATER HEATERS, CONTROLS, CHIMNEYS, FLUES, AND VENTS (1) The water heaters T&P valve is leaking. 6.3 Picture 1 6.3 Picture 2 6.4 SINKS, FIXTURES AND TOILETS Minor Repair: The toilet in the master bathroom is loose from the floor and it is stopped up. Castle Check, LLC page 25 of 27

6. PLUMBING 6.4 Picture 1 6.5 SHOWER/TUB TILE WALLS Minor Repair: Caulking/sealant is needed at/around the bathroom tub and or shower joints in the master bathroom. This is typically an easy repair. 6.6 BATHROOM VENTILATION Bathroom exhaust fan in the upstairs hall bathroom did not function when tested. 7. ELECTRICAL 7.4 OUTLETS, SWITCHES AND FIXTURES (Observed from a representative number; operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) (1) The GFCI electric outlet in the kitchen did not trip off when tested. This is typically an easy repair. 9. AIR CONDITIONING 9.1 COOLING AND AIR HANDLER EQUIPMENT (1) The insulation on the refrigerant line(s) is missing, damaged, or deteriorated at one or more areas. It is important that the refrigerant line be well insulated all the way from the condenser unit to the evaporator unit to prevent condensation and to increase cooling efficiency. Castle Check, LLC page 26 of 27

9. AIR CONDITIONING 9.1 Picture 1 11. INSULATION AND VENTILATION 11.0 ATTIC INSULATION The attic pull down stairs insulation is missing, it is easy to add this insulation and it will improve the efficiency of the heating/cooling system(s). This report is provided for the specific and exclusive use and benefit of Castle Check, LLC customer(s) only. Secondary and third party readers of this information should hire a Qualified and Licensed Home Inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property. Prepared Using HomeGauge http://www.homegauge.com SHGI (c) 2000-2007 : Licensed To Castle Check, LLC Castle Check, LLC page 27 of 27