Testing FM Systems on the FP35 Hearing Aid Analyzer -1-



Similar documents
Step-by-Step RECD Guide

Pediatric Fitting Guide

Hear The Future...Now! SIEM-2T/SIEM-2R

Using Your Fitting Software This guide provides comprehensive, task-based information about all the fitting software features.

PURE TONE AUDIOMETER

HyperX Cloud Headset

COUNTRYMAN E6 OMNIDIRECTIONAL EARSET MICROPHONE

Generic - Hearing Loop - (AFILS) U.S. System Specification

NCSU CBE Conference Room 2018 EB1 Touchpanel Users Guide

Generating Element. Frequency Response. Polar Pattern. Impedance. Output Level

CONTENTS. Zulu User Guide 3

1000+ AUDIOMETER OPERATING INSTRUCTIONS

Quick Start Guide for Video Conferencing

UB1 P R O F E S S I O N A L M I C R O P H O N E S

SUMMARY TABLE VOLUNTARY PRODUCT ACCESSIBILITY TEMPLATE

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

THE SOUND-POWERED TELEPHONE SYSTEM

Learning Objective. To learn about current technological interventions that allow children with hearing loss to access auditory information

Search keywords: Connect, Meeting, Collaboration, Voice over IP, VoIP, Acoustic Magic, audio, web conferencing, microphone, best practices

The technology in this room supports both local and video conference presentations with the following equipment:

Step 1: Select the Start Menu, then Control Panel.

Cordless TV Listening System. Set 830-TV. Instruction manual

instruction guide Version 2.2 Table of contents

Stream Boost: All About That Bass

CAT 885 Troubleshooting Guide

What you need to know about student s hearing technology for classroom listening

A Microphone Array for Hearing Aids

Hear Better With FM. Get more from everyday situations. Life is on.

The Essentials of Fitting Hearing Aids to Babies

Using FM. A guide for children and their families on how to use an FM solution with hearing aids

PRODUCT SHEET OUT1 SPECIFICATIONS

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

TV & Assistive Listening Devices

MASTER GUIDE 1. PACKAGE CONTENTS

Step 1: Select the Start Menu, then Control Panel.

How To Sell A Talan

OTICON RIA pro OTICON RIA

Instructions for the use of E-A-RTONE 3A. Insert Earphones. Revised 1997 per ANSI S and ISO 389-2: /99

4.2. Desktop Fitting Guide. Content. August 2015

Using Computer Audio in Adobe Connect Meetings Metropolitan Community Churches Office of Leadership and Development

HEARING SCREENING FOR CHILDREN

The technology in this room supports both local and video conference presentations with the following equipment:

VoIP Audio Setup - PC Users

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

HEARING SCREENING (May 2006)

Wireless. with Personal Mix Control and EP3 Dynamic Earphones

CS540. Wireless Headset System. User Guide

Software Newsletter April 2016

TV Ears Digital System Installation Guide

Audio Help for Webinar Attendees. GoToWebinar User Guide. Virtual Operating System (VMware, Parallels, etc.)

DAILY BIOLOGIC CHECK OF AUDIOMETERS

Cheat Sheet for Local Church Audio Training Sound Essentials. Kick:

DSP Laboratory: Analog to Digital and Digital to Analog Conversion

Your Hearing Aids A guide for helping children and their families understand and take care of their hearing aids

HCPCS CODING REFERENCE CHART

Classroom Setup... 2 PC... 2 Document Camera... 3 DVD... 4 Auxiliary Lecture Capture Setup... 6 Pause and Resume... 6 Considerations...

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

PART 1. Using USB Mixer with a Computer

FREQUENCY RESPONSE OF AN AUDIO AMPLIFIER

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Nucleus CP810 Sound Processor and Nucleus CR110 Remote Assistant Troubleshooting Guide

MAINTENANCE & ADJUSTMENT

Current Probes. User Manual

Tuning Subwoofers - Calibrating Subwoofers

User Guide Audéo PFE 232 with microphone

INSTRUCTIONS FOR USE Pro-Ject Phono Box II USB

Everybody has the right to

B. Equipment shall be furnished and installed as specified. No substitutions will be allowed.

Y-Not. User s Manual. RJM Music Technology, Inc.

The E-Scope Electronic Stethoscope Catalog of Products April 25, 2012

Plantronics Blackwire C610-M Blackwire C620-M

Best Practices for Adobe Connect Meetings

Table of Contents. Introduction... 1 SE50 Features... 2 Using the SE Specifications... 4

Setting up and Using the Bluetooth Card

A Hearing Aid Primer

Safe Listening! How I Enjoy My Music and Avoid a Silent Future (ITU and WHO) Brian Copsey

VPAT for Apple ipad Air 2

User Manual. Please read this manual carefully before using the Phoenix Octopus

How to register and use our Chat System

Guidelines for Fitting and Monitoring FM Systems

Audio/Visual System User Operations Manual 100 Seat Lecture Hall Enhanced

Auditorium Audiovisual System User s Guide

Model WH20 User Guide

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

Features, Benefits, and Operation

Interference to Hearing Aids by Digital Mobile Telephones Operating in the 1800 MHz Band.

Avaya Model 1408 Digital Deskphone

AVR 158. Audio/video receiver. Quick-Start Guide ENGLISH

Understanding Sound System Design and Feedback Using (Ugh!) Math by Rick Frank

Evaluation of Digital Remote Microphone Wireless Systems. Jace Wolfe

AM-1. AM-1 Setup Guide for the Polycom Video Conferencing Systems QUICK SETUP GUIDE

Audio processing and ALC in the FT-897D

Manufacturer: Phonak AG Laubisrütistrasse 28 CH-8712 Stäfa Switzerland /V1.00/ /A+W Printed in Switzerland

TV hearing aid BL-8008A BL-8008B. Manual

User Guide. Live Meeting. MailStreet Live Support:

Transcription:

Testing FM Systems on the FP35 Hearing Aid Analyzer -1-

Testing FM Systems on the FP35 Hearing Aid Analyzer Introduction This workbook describes how to test FM systems with the FP35 Hearing Aid Analyzer using coupler measurements. An FM system consists of two main parts: a transmitter and a receiver. The transmitter microphone can come in many different sizes and shapes, and it can be nondirectional or directional. The receiver can be a button earphone, or it can be attached to a BTE hearing aid either internally, via a boot receiver, via a silhouette coil, or via a neck loop. No matter the combination, all FM systems can be tested. These test procedures should be performed on an FM system at least once a year. For children under the age of 5, these procedures should be performed every six months. -1-

As with most hearing aids, both the gain and the maximum output (OSPL) of an FM system should be adjusted to meet the listener s auditory requirements. There are several issues to consider when comparing the hearing aid and FM performance. With FM systems, the pickup microphone is normally worn at the chest, 6-8 inches (15-20 cm) under the mouth of the talker, whereas with hearing aids, the pickup microphone is worn by the listener, typically at a minimum of 3 ft. (1 m) from the talker. This difference affects both the level and the frequency content of typical input signals. With FM systems, typical speech input levels range from 75 to 85 db SPL, as compared with 60 to 70 db SPL for hearing aids. With the chest-worn location of the pickup microphone, the high frequencies are relatively -2-

lower in level (about 5 db at 5 khz) and the low frequencies are relatively higher in level (about 5 db at 500 Hz) as compared with directly in front of the talker s mouth. The increased vocal effort by teachers in a classroom situation may create further changes to the speech spectrum at the input to an FM system, as compared with the speech spectrum at the input of a hearing aid (Cornelisse et al., 1991). FM systems often have an automatic gain control (AGC) or other nonlinear characteristic that could interact with that of the hearing aid being used to deliver the FM signal if such a hearing aid is being used in this fashion. The frequency response of an FM system is often not as adjustable as that of a hearing aid, limiting the range of electroacoustic modifications available. -3-

It is recommended that the FM system provide a +10 db advantage over the hearing aid microphone for best audibility. The procedures recommended in this workbook are based upon the FM Offset Procedure, sometimes called the Phonak FM Offset Procedure or POP, which is available for download from www. phonak.com. Using this procedure, the output from the FM system is matched to the output from the hearing aid microphone. It is assumed that the actual FM output will have a +10 db advantage over the hearing aid microphone when the adjustments made in this procedure are followed since the typical input to the FM system will be higher (75-85 db SPL) than the typical input to the hearing aid microphone (60-70 db SPL). -4-

Basic FM Offset Procedure This section describes the basic FM Offset Procedure. Step-bystep instructions on how to implement this procedure on the FP35 Hearing Aid Analyzer are described later in this workbook. 1. 2. 3. 4. 5. Program the hearing aid appropriately for the hearing loss of the patient. Turn OFF any automatic feedback control and/or noise reduction on the hearing aid, if possible. Attach the FM receiver to the hearing aid. Program the FM receiver for a +10 db FM advantage. Set the FM system to the FM+Hearing Aid (or FM + Mic) position. -5-

6. Place the hearing aid in the test box with the FM microphone outside the text box on mute or in a quiet environment. 7. Determine the RMS Out using this test setup with a 65 db SPL broadband signal (HA-65). 8. Switch the positions of the hearing aid and the FM microphone so that the FM microphone is inside the test box and the hearing aid is outside the test box (but still attached to the coupler). 9. Determine the RMS Out using this test setup with a 65 db SPL broadband signal (FM-65). 10. Calculate the FM Offset = FM-65 HA-65. If the difference is ±2 db, adjust the output of the FM system. If the FM Offset is equal to or greater than +2 db, then you will need to reduce the FM gain level in the receiver by the -6-

offset value. If the FM Offset is equal to or less than -2 db, then you will need to increase the FM internal gain setting by the offset value. 11. Repeat steps 6-10 until the FM Offset is within ±2 db. 12. Place the hearing aid in the test box with the FM microphone outside the text box on mute or in a quiet environment. 13. Perform a frequency response measurement using a puretone sweep with a 90 db SPL input. Make sure the response doesn t exceed maximum output targets. 14. Switch the positions of the hearing aid and the FM microphone so that the FM microphone is inside the test box and the hearing aid is outside the test box (but still attached to the coupler). Make sure the response doesn t exceed maximum output targets. -7-

Attaching the FM Receiver to a Coupler A variety of output devices can be used with FM systems. These include button earphones, behind-the-ear (BTE) units with an internal FM receiver, an external FM receiver boot, or options for coupling to the personal BTE hearing aid via direct audio inputs, silhouette coils, or neck loops. This section tells you how to arrange the 2-cc coupler with each type of output device. -8-

FM Receiver FM Receiver FM Receiver Foam Pad Foam Pad Foam Pad to Analyzer to Analyzer to Analyzer Figure 1A Button Earphone Figure 1B Internal FM Receiver, External FM Boot Receiver or Direct Audio Input Figure 1C Silhouette Coil -9-

Button earphone (Figure 1A) 1. 2. 3. If necessary, remove the ear-level adapter from the HA-2 coupler. Snap on the button earphone to the HA-2 coupler. Place the coupler/hearing-aid assembly on a foam pad outside the text box. BTE microphone/receiver or BTE aid with internal FM receiver, external FM boot receiver, or direct audio input (Figure 1B) 1. 2. 3. Attach the ear-level adapter to the HA-2 coupler, if necessary. Attach the BTE hearing aid to the HA-2 coupler. Set the switch on the position to receive the signal. -10-

4. Place the coupler/hearing-aid assembly on a foam pad outside the test box. BTE aid with silhouette coil (Figure 1C) 1. 2. 3. 4. 5. 6. Attach the ear-level adapter to the HA-2 coupler, if necessary. Attach the BTE hearing aid to the HA-2 coupler. Place the coupler/hearing-aid assembly on a foam pad outside the test box on a nonmetallic surface during testing. Choose a location free of stray magnetic fields (away from video monitors and other electrical devices). Align the silhouette coil underneath the hearing aid, simulating the way it would be worn on the ear. Set the hearing aid for T. -11-

BTE aid with neck loop (Figure 1D) 1. 2. 3. 4. 5. Within the range of the coupler microphone cable, choose a location to seat the listener that is free of stray magnetic fields (away from video monitors and other electrical devices). Place the neck loop around the listener s neck or around the neck of a person of similar size. Attach the listener s hearing aid to the HA-2 coupler and set it to the T position with a normal use setting of the volume control. While holding the coupler in hand, place the hearing aid at the listener s ear, as typically worn. Take care not to move or touch the coupler microphone while testing. -12-

FM Receiver to Analyzer Figure 1D: Neck loop -13-

Occluding the Second Microphone The FM Offset procedure described in this workbook performs sequential measurements of the hearing aid microphone and FM microphone. In most cases, the second microphone not being tested (that is, if the hearing aid is in the test box, the FM microphone or vice versa) is still active although it won t receive the test signal directly. Therefore, this test procedure must be performed in a quiet environment with low ambient noise. It is recommended to further isolate the second active microphone by placing it inside a spare sound chamber (if one is available) or even a shoebox lined with foam. This will help improve test accuracy. -14-

Step-by-Step FM Offset Test Procedure 1. 2. 3. 4. 5. 6. Press [F3] from the Opening Screen (with the Frye logo) to enter the Coupler Multicurve screen. Level the sound chamber following the standard leveling procedure found in the Operator s Manual. Make sure the test graph is labeled db SPL in the upper left corner of the screen. If it is labeled db GAIN, press [MENU] and use the arrow keys to change the Display from Gain to SPL. Press [MENU] again to close the local menu. Program the hearing aid appropriately for the hearing loss of the patient. Turn OFF any automatic feedback control and/or noise reduction on the hearing aid, if possible. Attach the FM receiver to the hearing aid. -15-

7. Program the FM receiver for a +10 db FM advantage. 8. Set the FM system to the FM+Hearing Aid (or FM + Mic) position. 9. Attach the hearing aid to the coupler, as described in the previous section and insert the coupler microphone. 10. Place the hearing aid in the sound chamber with the hearing aid microphone at the reference point of the chamber. Close and latch the lid. See Figure 2. 11. Place the FM microphone outside the sound chamber. If possible, mute the FM microphone. Otherwise, it is recommended to place it within a sound occluding box. See Figure 2. 12. Use [F2] to select CRV 1. 13. Use [F4] to select the DIG SPCH. 14. Use the [, ] keys to set the Source to 65 db SPL. -16-

15. Press [START/STOP]. After the measurement has stabilized, press [START/STOP] again the stop the test. Make note of the RMS OUT of the measurement. See Figure 3. 16. Switch the positions of the hearing aid and the FM microphone. That is, place the FM microphone at the reference point of the sound chamber and place the hearing aid outside the sound chamber while it is still attached to the coupler and analyzer microphone. Close and latch the lid of the sound chamber. See Figure 4. 17. Use [F2] to select CRV 2. 18. Use [F4] to select the DIG SPCH. 19. Use the [, ] keys to set the Source to 65 db SPL. 20. Press [START/STOP]. After the measurement has stabilized, press [START/STOP] again the stop the test. Make note of the RMS OUT of the measurement. -17-

21. Subtract the RMS OUT of CRV 1 from the RMS OUT of CRV 2. This calculated number is the FM Offset. If the difference less than ±2 db, the FM receiver has been adjusted accurately and you may skip to the next section. If the FM Offset is equal to or greater than +2 db, then you will need to reduce the FM gain level in the receiver by the offset value. If the FM Offset is equal to or less than -2 db, then you will need to increase the FM internal gain setting by the offset value. 22. Adjust the gain of the FM receiver as determined in the previous step and repeat steps 10-21 until the FM Offset is less than ±2 db. -18-

OPERATE FONIX FP35 Hearing Aid Analyzer FM mic Figure 2: Hearing aid set up -19-

Figure 3: The FM offset for this test is 85.9-89.5 = -3.6. The FM gain level needs to be increased by about 3 db. -20-

Step-by-Step Maximum Output Test Procedure This section describes make sure the FM system does not exceed the maximum output target. Obtaining the maximum target itself is outside the scope of this workbook. 1. Follow the steps in the previous section to adjust the FM Offset of the FM system. 2. Use [F2] to select CRV 3. 3. Use [F4] to select NORMAL. 4. Use the [, ] keys to set the Source to 90 db SPL. 5. Place the hearing aid in the sound chamber, and place the FM microphone outside the sound chamber. Close and latch the lid. See Figure 2. -21-

6. Press [START/STOP] to run the pure-tone sweep. The test will stop automatically. 7. Compare the test result to the maximum output target. Adjust the FM system if the measured response exceeds the target. 8. Switch the positions of the hearing aid and the FM microphone; place the FM microphone at the reference point inside the sound chamber and place the hearing aid outside the sound chamber. Close and latch the sound chamber lid. See Figure 3. 9. Use [F2] to select CRV 4. 10. Use [F4] to select NORMAL. 11. Use the [, ] keys to set the Source to 90 db SPL. -22-

12. Press [START/STOP] to run the pure-tone sweep. The test will stop automatically. 13. Compare the test result to the maximum output target. Adjust the FM system if the measured response exceeds the target. 14. If you have made any adjustments to the FM system, you may want to repeat the FM Offset test procedure to make sure that your changes didn t affect the normal speechlevel gain of the system. 15. Print the test results or use one of the FONIX software programs to save them to a computer database for future reference. -23-

Shoebox lined with foam FM mic Isolate environmental microphone FONIX FP35 Hearing Aid Analyzer Figure 4: FM microphone set up -24-