Design of High Temperature Electronics for Well Logging Applications



Similar documents
DEDICATED TO EMBEDDED SOLUTIONS

FlairFlex. Real-time fluid logging and analysis service

WELL LOGGING TECHNIQUES WELL LOGGING DEPARTMENT OIL INDIA LIMITED

GAS WELL/WATER WELL SUBSURFACE CONTAMINATION

TruTrak Automated directional drilling system

Havbunnsproduksjon. NTNU, 15 april 2013 Eldar Lundanes System Responsible for Controls and Data Management, Eastern Region.

Distributed Temperature Sensing - DTS

Collecting and Analyzing Big Data for O&G Exploration and Production Applications October 15, 2013 G&G Technology Seminar

Opportunities for HALT/HASS in designing robust electronics

Certificate Programs in. Program Requirements

Paradigm High Tech and Innovative Software Solutions for the Oil and Gas Industry

RESERVOIR GEOSCIENCE AND ENGINEERING

Guidelines the DNV way

Measurement While Drilling (MWD) Tools

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

I DDEDICATION 15O P T M S E SERVICES TO OPTIMISE EVERY PART OF THE OIL, GAS AND CHEMICALS INDUSTRY

Drilling Rigs and Well Technology. RAPID RIGS AND WELL TECHNOLOGY Cairn India Limited.

Graduate Courses in Petroleum Engineering

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

ENGINEERING AUSTRALIAN COLLEGE OF KUWAIT - CORPORATE TRAINING

FAN group includes NAMVARAN UPSTREAM,

DEPARTMENT OF PETROLEUM ENGINEERING Graduate Program (Version 2002)

Society of Petroleum Engineers SPE Global Training Committee Training Course Review Process

N4385A / N4386A Distributed Temperature System (DTS)

Geothermal. . To reduce the CO 2 emissions a lot of effort is put in the development of large scale application of sustainable energy.

Agenda. Michele Taliercio, Il circuito Integrato, Novembre 2001

Discover Viterbi: Petroleum Engineering

LO5: Understand commercial circuit manufacture

Petrophysical Well Log Analysis for Hydrocarbon exploration in parts of Assam Arakan Basin, India

WHITE PAPER. HALT and HASS in IPC 9592A. HALT - Highly Accelerated Life Test HASS - Highly Accelerated Stress Screen

ELECTRICAL & POWER DISTRIBUTION

Load Cell Troubleshooting

Schlumberger and Cameron Conference Call August 26, 2015

Electronic Drilling Recorder

Issue 1.0 Jan A Short Guide to Quality and Reliability Issues In Semiconductors For High Rel. Applications

powered by ingenuity Corrosion Logging Well Integrity Measurement

Technical Note SolarEdge Reliability Methodology

Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2

FIBER-OPTIC SENSING TECHNOLOGIES

RPSEA Project Management Plan

BS PROGRAM IN PETROLEUM ENGINEERING (VERSION 2010) Course Descriptions

Technology Developments Towars Silicon Photonics Integration

Industrial Technology

Well-logging Correlation Analysis and correlation of well logs in Rio Grande do Norte basin wells

Automotive Application Questionnaire for Electronic Control Units and Sensors. Electronic Components and Systems

An Introduction to Oil and Gas Well Servicing

Lead-Free Product Transition: Impact on Printed Circuit Board Design and Material Selection

Permanent Distributed Temperature Sensing at the Ketzin CO 2 Storage Test Site. ieaghg 6th Wellbore Network Meeting, April 28-29, 2010

Frequently Asked Transmission Pipeline Questions

PRESIDENT ENERGY PLC. ( President or the Company ) PARAGUAY UPDATE

IC 1101 Basic Electronic Practice for Electronics and Information Engineering

Vehicle Engine Management Systems

Argentina Tataru*, Marcel Adrian Piteiu*, Dan-Paul Stefanescu*, Ioana Vlasin*

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

Rework stations: Meeting the challenges of lead-free solders

CIN::APSE COMPRESSION TECHNOLOGY GET CONNECTED...

Degree/ Higher Education Jobs:

OilSim. Talent Management and Retention in the Oil and Gas Industry. Attract, identify, develop, and retain the right people

White Paper Product Quality Fujitsu ESPRIMO PCs, Fujitsu CELSIUS workstations, Fujitsu FUTRO thin clients

Evaluation of Soft Soldering on Aluminium Nitride (AlN) ESTEC Contract No /05/NL/PA. CTB Hybrids WG ESTEC-22nd May 2007

Well Data Submission Requirements Manual

Solution 1: Algorithm Positioning

The Tesla Roadster battery pack is comprised of about 6800 of these cells, and the entire pack has a mass of about 450kg.

Hydraulic control unit series

Role of Sockets in IC Product Life Cycle Ila Pal, Ironwood Electronics

Tuesday, March 17, 2015 Houston, TX. Energy Exchange 9:20 9:50 a.m. and 9:55 10:25 a.m. OIL AND GAS: ENVIRONMENTAL INSURANCE IS IT NECESSARY?

Supply Chain Management Services

From the Mill to the Well

Nexus. Reservoir Simulation Software DATA SHEET

MuAnalysis. Printed Circuit Board Reliability and Integrity Characterization Using MAJIC. M. Simard-Normandin MuAnalysis Inc. Ottawa, ON, Canada

FPO. Meeting and Exceeding API Standards: How Much Testing Do Pumps Really Need? White Paper

DLP-PU/E Instruction Manual

Unit ID: 482 Domain AUTOMOTIVE ELECTRICAL AND ELECTRONICS Title: Install and repair electrical lighting system of vehicles Level: 2 Credits: 6

LCD-TV RELIABILITY TESTING AN EFFECTIVE APPROACH

THE NEW 4X8 PANEL PCs INNOVATIVE HMI TECHNOLOGY FOR HAZARDOUS AREAS

Pulse Proof, High Power Thick Film Chip Resistors

Technical Spotlight. The Use of Ion Chromatography in the Printed Circuit Board Industry

SSI Technologies TULC Application Note

GORE Aerospace Cables and Materials

Oil and Gas Training and Competency Development. Developing expertise to efficiently meet key industry challenges

Arc Terminator Active Arc-Resistant Switchgear

Italy - Porto Tolle: storage in offshore saline aquifer

CHAPTER 13 LOAD HOOKS

Application of Nuclear Magnetic Resonance in Petroleum Exploration

Unit LT01 Carry Out Routine Lift Truck Maintenance

International Journal of Advancements in Research & Technology, Volume 3, Issue 4, April ISSN

Top Drive Service Loops. Conventional, Enhanced and Superior Solutions for Drilling Applications

Deepwater Horizon Accident Investigation Report

Executive Summary. Table of Contents

3D Deformation Measurement with Akrometrix TherMoiré and Digital Fringe Projection

in-service inspections

Electrical Drive Modeling through a Multiphysics System Simulation Approach

PRODUCT INFORMATION. Range of HUMS and Engine-monitoring Accelerometers Type , , 4523, 8345 and 8347-C.

Stilling Well Recommendations

I N T E L L I G E N T S O L U T I O N S, I N C. DATA MINING IMPLEMENTING THE PARADIGM SHIFT IN ANALYSIS & MODELING OF THE OILFIELD

Measuring of the Temperature Profile during the Reflow Solder Process Application Note

Transcription:

Design of High Temperature Electronics for Well Logging Applications Bernard Parmentier Schlumberger, France BParmentier@clamart.oilfield.slb.com Ovidiu Vermesan SINTEF, Norway Ovidiu.Vermesan@sintef.no Lionel Beneteau Schlumberger, France LBeneteau@clamart.oilfield.slb.com 1 Introduction Well logging represents the most developed applied industry currently using high temperature electronics technology. The penetration of high temperature electronics in this market exceeds that of other application sectors like automotive or aerospace. Well logging has been the primary driving force and leading financial sponsor for the development of high temperature electronics in the last 25 years. The use of high temperature components within the petroleum exploration and geothermal industry is characterised by: Low volume /100 tools per year. High level of specialisation / many different sensors used. High accuracy, high performance up to 22 bits of resolution. High reliability level/5 years at 150 C High temperature electronics and the interaction with the design, implementation, production and testing are presented in Figure 1. Material Properties Design Methodologies Productio Application Failures Modes Identification Quantification of Mechanisms HT Electronics Integrated/Passive Devices Packaging Test Well Logging Oil & Gas Geothermal Test Methodologies Reliability Figure 1. High temperature electronics design and implementation This paper describes a number of issues related to the design of high temperature electronics for well logging applications.

The paper is organised as follows: In Section 2 the characteristics and the temperature requirements for electronics components used in well logging are presented. In Section 3, the applications are described. Design issues in high temperature electronics for well logging applications are presented in Section 4. Section 5 discusses the trends and future developments in the industry. 2 Characteristics and Temperature Requirements for Electronic Components in Well Logging Applications Within the field of oil and gas well logging, the use of integrated instrumentation systems that withstand high temperatures aims at increasing the recovery of oil while at the same time reducing costs, emissions and safety hazards. The development in technology for the high cost, low volume well applications can be extended to cover general process monitoring thereby impacting the competitiveness of a large range of industries. Operating conditions in oil wells are just outside the operating range of standard sensors and electronics in terms of requirements on size, operating temperature or pressure. Putting together a well logging system is a major undertaking since there are few standard components available, and the demands on reliability are strong. As a consequence, well logging projects have been large, and been forced to address many issues, from sensing through communication to data management, within the same project. Even though a large number of innovative solutions have been developed, the full potential of new technologies has not been exploited. The main operating conditions and time requirements for typical applications are presented bellow: Well Depths: Oil and gas: 3-6 km. Geothermal: 10 km. Temperature Range Majority of oil wells are under 125 C with 80% <150 C 95% of oil wells are under 175 C Only 2% or 3% are 200 C range or higher Geothermal wells: 25 C to 400 C with most wells being covered by 325 C Environmental Conditions: Vibrations 10g at 10-60Hz, 1g at 240Hz Mechanical shocks 500g/5ms Pressure 150 bars Substances: oil, mud, humidity; corrosive chemicals Typical Applications and Operation Time Requirements Traditional wire line logging (2 to 6 hours) Measurement while drilling (from 100 hours to 500 hours) Permanent gauges, intelligent completions ( >40,000 hours) 2.1 Design Approaches The tools for logging applications, with the exception of those for very high temperature and short logging time using thermal insulation, are build using commercial materials and components, selected and qualified for the operating temperature. The rules for selecting and using the materials and components are summarized as follows: Stringent selection and testing procedures for standard commercial grade components and materials. The use of ASICs for specific functions. The use of MCMs (Multi Chip Modules) when size is critical.

No use of organic materials when long-term reliability is mandatory. There are various packaging options available for today s high temperature electronics. These solutions are specific to the application with a customed assembly process, which in generally comes at a cost premium. 3 Well Logging Applications Well logging and data analysis technologies enhance the ability to image between wells and provide information with increased resolution into the reservoir model. Optimal well placements are achieved by identifying the best producing locations, considering azimuthal anisotropy, and focusing on mechanical rock strengths in order to achieve high performance drilling while preserving wellbore integrity. Wireline logging determines which formations intersected by the wellbore may contain hydrocarbons (typically less than 1 percent of the well), and takes measurements to provide descriptive and quantitative evaluations of the rock penetrated, and the type and amount of fluid contained therein. Although logging while drilling (LWD) has been available for more than 15 years, for much of that time the tool suite was too limited for the technology to contribute fully to formation evaluation. In the past few years, this situation has changed. Now LWD does offer a useful range of downhole measurements for petro-physical purposes. In logging the well, four main types of equipment are used: Downhole instruments that measure data from different sensors, Computerised surface data acquisition systems that analyse and store data, Cable/wireline that is used for data communication with the downhole instruments and mechanical support Hoisting equipment to raise and lower instruments. 4 High Temperature Design Issues in Well Logging Applications In this section the main high temperature design issues in well logging applications are presented and discussed. High temperature electronic systems for well logging applications require electronic circuits that preserve their properties, functions, and reliabilities up to the desired operation temperature and interconnection/packaging technology on a substrate to form an electronic circuit with long term reliable operation capability The main design issues for high temperature electronics for well logging applications are: Proper understanding of field operating conditions / mission profile Selection process of components that can meet high temperature performances Design methodologies that can accommodate the drift of performances of parts Design of integrated devices (ICs, ASICs, integrated instrumentation systems) that meet industrial requirements and increase reliability and testability Passive component development for high temperature operation High temperature materials Interconnections Packaging for high temperature reliable operation Electrical and mechanical assembly Testing and reliability data (performance specification and lifetime at high temperatures) Electronic system integration that meets the requirements of well logging applications This is illustrated on Figure 2.

of Design Methodology Regular Quality Audits of First Prototypes Limitations of Field Repair Process Field Operations Requirements Design for Reliability Part (Component, PCB, ) Electrical and Mechanical Assembly Production Test Field Operations & Repair Field Equipment Obsolescence of Parts of Assembly Processes Assessment of Production Test Coverage Proper understanding of Field Operating Conditions Figure 2. Main design issues for high temperature electronics for well logging applications The high temperature designer has to understand each and every part of the design and assembly process of the equipment and its specific failure mechanisms and their sensitivity to environmental conditions. The reliability of the overall system is limited by its weakest element. When replacing the first part in the failure chain, it is critical to know what is coming next, and so on until the latest failure mechanism is reached. Figure 3 illustrates this cascade of failures over the operating time of a tool under given operation conditions. Nevertheless, the best approach is to use technologies completely qualified to fulfil the overall lifetime of the tool. Cost and associated risks due to the failure or due to the repair process push technology departments to select the right solution. Part11 Part10 Part12 Part9 Part13 Time to first failure Part8 t=0 Part1 Time for all parts In failure Part7 Part2 Part6 Part4 Part3 Figure 3. Cascade of failures over the operating time of a tool under given operation conditions

Figure 4 represents the failure probability as a function of time for a sub-assembly that is part of a high temperature electronics system. Infant mortality is eliminated using burn in methods and screening tests. λ(t) Failure rate very low λ(t) is constant & very low Infant mortality Intrinsic Random failure Extrinsic Aging Intrinsic Figure 4. Sub-assembly failure probability as a function of time 4.1 Design Steps Over the Complete Lifetime Cycle of Oilfield Equipment In the design phase is important to review the specificities of each design step over the complete life cycle of oilfield equipment. The following elements are extremely important for the design of high temperature electronics equipment. 4.1.1 Understanding Field Requirements Considering that there is a diversity of oil fields from different market segments, it is important to understand what the customer really wants so the high temperature equipment is designed optimal (no over-design or under-design). Mission profile includes normal and non-normal exploitation and defines the application domain of the equipment. 4.1.2 Design for Reliability Derating factors, fault tree analysis and no single fault failure, FMECA, heavy mixed domain simulations (electrical thermal mechanical hydraulical) have to be considered early in the design phase. Design should also focus on manufacturability, and design upgrade for obsolescence management 4.1.3 Selection of Parts and Materials In this phase the library of failure modes and qualified parts are collected, proper qualification plans are made and market intelligence is gather taking into account the obsolescence issues including the evaluation of standard components versus ASICs and MCMs. Physics of failure methodology or qualification by knowledge of the technology allow for selection of the best solution, decrease risk, and focuses the analysis on real issues. Physical and chemical properties of materials, metallurgy interfaces should be identified and quantified. 4.1.4 Electrical and Mechanical Assembly High temperature electronics quality requires industrial processes, well monitored but still compatible with low production volume. Delaminations, contamination and bad solder joints, are major reliability concerns and should be addressed in the early phase of the design. Process definition, monitoring and non-destructive analyses are key solutions to avoid problems during equipment qualification.

4.1.5 Production Test Testing is one of the most important phases for qualifying the functionality of the equipment for high temperature operation. The assessment of test coverage determines the balance between the time necessary for test (cost) and the coverage of the blocks and modes of operation that are tested. Based on qualification tests of first prototypes, the production test specification and the necessary tests and screen tests are defined. Screening tests should get rid of early failures without taking too much of the equipment remaining life at constant failure rate. 4.1.6 Field Operations and Repair Proper training of Field Engineers to understand the equipment limitations and strengths. The field repair process has to be understood and limited in scope to meet equipment assembly process quality. The ultimate goal is to meet customer expectations, as specified during Field Requirement Analysis phase. 5 Trends and Future Developments in High Temperature Electronics in Well Logging Industry The well logging industry provides low volume, highly specialised high temperature electronics technology and has a strategic significance for the developments in high temperature electronics. ASIC on bulk silicon or on SOI, Multi chip packaging, thermo-mechanical simulations are major axis for future high temperature developments. 6 References [1] R.K. Kirschman, High-Temperature Electronics, IEEE Press, NY, 1999. [2] O. Vermesan and L-C. Blystad, High Temperature Electronics Reliability, SINTEF Report, STF72F02617, Oslo, Norway, 2002. [3] O. Vermesan, H. Grindvoll and L-C. Blystad, Testing of Elevated Temperature Electronics ASICs and Hybrid Circuits, SINTEF Report, STF72F02619, Oslo, Norway, 2002. [4] T. Veneruso, "Applications for High Temperature Electronics in Oil, Gas, and Geothermal", Proceedings-First International High Temperature Electronics Conference, Albuquerque, NM, June 1991.