Design of UPS Battery Remote Monitoring System



Similar documents
Design of Remote data acquisition system based on Internet of Things

UPS battery remote monitoring system in cloud computing

International Journal of Engineering Research & Management Technology

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

ONLINE HEALTH MONITORING SYSTEM USING ZIGBEE

PowerGem Pro Uninterruptible Power Supply

Coal Mine Security System

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Design of WSN-Based Remote Monitoring System for Environmental Parameters in Substation

Bus Data Acquisition and Remote Monitoring System Using Gsm & Can

Design of Strong-motion Monitoring System for Dam-reservoir D s e i s gn of Stro r ng-mo m tion Monito t ri r ng Syst s em

Application of Wireless Sensor Network and GSM Technology: A Remote Home Security System

Measuring Temperature withthermistors a Tutorial David Potter

A Study of Low Cost Meteorological Monitoring System Based on Wireless Sensor Networks

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

Intelligent Home Automation and Security System

Radio sensor powered by a mini solar cell the EnOcean STM 110 now functions with even less light

Simplify Data Acquisition with a Built-in LXI Web Server

Android based Alcohol detection system using Bluetooth technology

Sensor network infrastructure for intelligent building monitoring and management system

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

The Business case for monitoring points... PCM architecture...

ontroller LSI with Built-in High- Performance Graphic Functions for Automotive Applications

LOCAL INTERCONNECT NETWORK (LIN)

Current Monitoring Kit QUICK START GUIDE

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

LOCAL INTERCONNECT NETWORK (LIN)

The design and implementation of the environment monitoring system of smart home based on EnOcean technology

Current Monitoring Kit

Design And Implementation Of Bank Locker Security System Based On Fingerprint Sensing Circuit And RFID Reader

LOCAL INTERCONNECT NETWORK (LIN)

DEVELOPMENT OF VIBRATION REMOTE MONITORING SYSTEM BASED ON WIRELESS SENSOR NETWORK

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Accident Notification System by using Two Modems GSM and GPS

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Delta Transportation Automation Solution.

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

REMOTE ELECTROCARDIOGRAM MONITORING BASED ON THE INTERNET

Study on Differential Protection of Transmission Line Using Wireless Communication

Plc Based Monitoring and Controlling System Using Wi-Fi Device

Automated Security System using ZigBee

Application/Connection Examples

Final Design Report 19 April Project Name: utouch

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Design of Fuzzy Drip Irrigation Control System Based on ZigBee Wireless Sensor Network

Palaparthi.Jagadeesh Chand. Associate Professor in ECE Department, Nimra Institute of Science & Technology, Vijayawada, A.P.

SiteWeb Monitoring System. Real Time Power and Environment Monitoring Platform for Telecom Applications

Remote Patient Monitoring- An Implementation in ICU Ward

Research on Tower Crane Safety Control System Based on GPRS and U Disk Storage Wang Jin-yu 1, a, Fu Guang-jie 1, b, Lin Dong-xue 1, c, Wang Chao 1, d

Gsm Based Controlled Switching Circuit Between Supply Mains and Captive Power Plant

Implementation of Wireless Gateway for Smart Home

Real Time Implementation of Home Automation Using FPGA

Lab Experiment 1: The LPC 2148 Education Board

Computer Aided Design of Home Medical Alert System

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

Microcontroller Based Smart ATM Access & Security System Using Fingerprint Recognition & GSM Technology

Climate Ready Shade Operating Systems for residential applications.

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

PITE 3921 Battery Monitoring System User Manual P V1.0

Development of an Internet based Embedded System for Smart House Controlling and Monitoring

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

GPS & GSM BASED REAL-TIME VEHICLE TRACKING SYSTEM.

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Signal Processing in So.ware and Electric Field Sensing

An Introduction to MPLAB Integrated Development Environment

GSM Based Electrical Control System for Smart Home Application

Wireless Home Security System

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

The Research and Application of College Student Attendance System based on RFID Technology

e s p i o n s.com. V680 GPS Watch User s Manual

Design of Self-service Car Washing Machine Control System Based on ARM Zhengmin Cui a, Peng Sun b

Construction of intelligent home furnishing control system based on Internet of things and sensor

A PSTN Terminal for FSK Decoding and DTMF Dialing Applications

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Kokii BatteryDAQ. BMS Software Manual. Battery Analyzer Battery DAS

Development of an Automated Rescue System

NEW. EVEN MORE data acquisition and test stand automation

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

Journal of Chemical and Pharmaceutical Research, 2014, 6(5): Research Article

HUMAN-COMPUTER INTERFACE DEVELOPMENT OF WIRELESS MONITORING SYSTEM BASED ON MINIGUI

RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System

Network Enabled Battery Health Monitoring System

T a b l e o f C o n t e n t s

Intelligent Fleet Management System Using Active RFID

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

Design of a Wireless Medical Monitoring System * Chavabathina Lavanya 1 G.Manikumar 2

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

Impedance 50 (75 connectors via adapters)

A Dynamic Resource Management with Energy Saving Mechanism for Supporting Cloud Computing

AUTOMATIC LPG BOOKING, LEAKAGE DETECTION AND A REAL TIME LPG MEASUREMENT MONITORING SYSTEM


Simulation and Analysis of Parameter Identification Techniques for Induction Motor Drive

MICROCONTROLLER BASED SMART HOME WITH SECURITY USING GSM TECHNOLOGY

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

INTELLIGENT DISTRIBUTION NETWORK ANALYSIS AND INFORMATION ARCHITECTURE DESIGN

SiloPatrol. SiloTrack Inventory Management Software Version 3.5 BULLETIN 343B. Interface With Multiple Sensor Technologies

Transcription:

, pp.26-268 http://dx.doi.org/.4257/ijmue.24.9.9.28 esign of UPS Battery Remote Monitoring System Jiabin Wang, Haiying Wang 2,*,Tianjun Sun 2,Yuran Wang 2 and Ruilin Wang 2 aqing Oil Field Chemical Co.,LT, aqing,china 2 School of Automation, Harbin University of Science and Technology, Harbin,China wanghy@hrbust.edu.cn Abstract UPS remote monitoring system based on MSP43 single chip microcomputer design, using modular thinking as the core to build the overall structure, to realize the voltage, current and temperature of the online real-time monitoring through the acquisition module in the aspect of hardware, and putting forward resistance measurement method that based on ac injection method and phase lock amplifying method; Using software to implement the UPS fault information alarm function through the overall process design. Keywords: MSP43 single chip microcomputer; monitoring system; internal resistance measurement. Introduction With the rapid development of science and technology, monitoring system using the computer and network to realize remote monitoring application level is also gradually improved, remote monitoring of UPS as a kind of existing technology, is widely used in medical, commercial, banking, communications, transportation and other fields. At the same time, with the development of unattended substation, power system automation level unceasing enhancement, the good performance of UPS monitoring and decision has become a pressing problem []. Battery is an important part of UPS power supply, when external electric sudden interruption or voltage instability, it can provide a stable and continuous power supply. Therefore, for UPS charging and discharging process control, on-line real-time monitoring of each single voltage, current and temperature, and according to the realtime acquisition of voltage, current value to calculate internal resistance, through than with conventional index timely find out the damage or performance significantly reduce monomer, and then select the fault, ensure the consistency of power supply system and the safety reliability [2-3]. Usually, at home and abroad, there are two types of UPS remote monitoring technology: one is the relay inspection monitoring technology; Secondly, a distributed monitoring based on computer technology. The former on the implementation is more complex, and it has a high reliance on hardware, now use relatively little; while, the latter has high transmission rate, at the same time realize the unattended [4]. According to the above problem, this paper based on the modular thought, build UPS remote monitoring system general structure, in terms of hardware, through the design of voltage, current and temperature monitoring circuit, and using based on ac injection method and phase lock amplifying method of resistance measurement method of single cells in voltage, current, temperature, and the internal resistance of the online real-time monitoring; In the aspect of software, based on the relevant knowledge of database and C+ + ISSN: 975-8 IJMUE Copyright c 24 SERSC

design process, the overall structure to achieve a friendly man-machine interface design and text message alarm function. 2. The Overall Structure esign In this paper, through the design of software and hardware, build UPS remote monitoring system, operator through monitoring software on the computer platform and UPS power supply system to realize the man-machine dialogue, its overall structure is divided into the slave part design and upper computer design of two parts: the design of the next bit machine, design acquisition module and a UPS remote monitor, by RS485 and wan communications. In the upper computer design, combining with the relevant knowledge, database and C++ design is the PC software system of fault query, alarm prompt. Internal failure occurs when the UPS, can prompt the fault information and send the report to the police, at the same time dealing with important and must be saved information, UPS remote monitoring system for overall structure as shown in Figure. UPS cabinet UPS monitor The upper computer remote monitoring platform Fault diagnosis Alarm module Signal lines The voltage is too high Communication and database processing Signal lines RS485 wan wan Too much electricity SMS MOEM Receive SMS The temperature is too high Signal lines The engineer station The database server Internal resistance change alarm Figure. UPS Battery Remote Monitoring System for Overall Structure 3. The Slave Part esign 3.. The Selection of the Master CPU Single chip microcomputer as the master CPU monomer batteries in the voltage, current and temperature data signal acquisition, and then through simulation loads connected to the control relay, and adopts ac injection method and phase lock amplifying method of resistance measurement, finally using RS485 communication data real-time upload first place machine. We based on the hardware precision and function component costs, combined with the internal structure of main control module, selecting MSP43F49 ultra low power consumption micro-controller to realize the function of the main controller [5-6]. Relative to other micro controller (8C5), its advantage lies in: MSP43 MCU built-in Flash, in this way can save the hardware circuit board wiring space, reduce the power consumption of the system of five times at the same time, and combined with the hardware of MCU assembly language and C language programming, the system of the MSP43 are closely, timeliness is greatly increased. 3.2 Acquisition Module esign. Voltage acquisition: This design adopts the method of cycle test, will transmit the collected digital signal continuously to MSP43 single chip microcomputer. Monomer voltage detection accuracy of mv, including selection of photoelectric coupler, compared with the general design of analog switch, to avoid the in the measurement circuit is not gating UPS power loss caused by the discharge. At the same time, different amplifier circuit is changed to the size of the test voltage, by adjusting the specific multiple 262 Copyright c 24 SERSC

7TAB 8TAB V5+ R 2 R 3 5 K 5 K A 7C Fu. 2 3 5 4 7 R R 4 4U 2B8S 5U 2B8S 2U 2B8S 2 5 K AU 747PO 2 5 K 8 6 ATUO U 9 5R9 K 257SCA CV V V O U T V V V Q Q Q +PI -PI 5 V 5 V 5 V 53R K 3R K8. 2C Fu. AOL KCAPTAB 43R C Fu. 4 K Fu74. C 2 A 2 3 5 A 8R3 4.7K 4 7 2 3 5 A5U 46PCM 5 V 4 7 8 6 2.2P A3U 46PCM CVA 8 6 CVA 9NICA 8NICA International Journal of Multimedia and Ubiquitous Engineering relationships, making the voltage conforms to the single chip microcomputer A/ converter voltage range. Filter circuit is used to filter the voltage ripple caused by the unstable sampling circuit; the voltage tends to level off, the voltage monitoring circuit as shown in Figure 2. Figure 2. Monomer Battery Voltage Acquisition Circuit 2. The current collection: the design selection ASC75x current sensor series, ultra-low power consumption, low cost, 5V power supply, and, in the terminal 4, 5, and voltage isolation between, 2, 3, at the same time, through the design different packaging can expand the current measuring range, and expand the application scope, the current monitoring circuit as shown in Figure 3. Figure 3. Single Channel Current Sampling Circuit 3. The temperature acquisition: the design selected as temperature sensor S8B2 chip implementation of UPS internal and surrounding multi-point measurement of the temperature of environment, and the chip with single bus structure, which can connect to multiple temperature sensor on a bus, the range of 55 ~ + 25, in line with the outside environment temperature (2 to 6 ), monitoring circuit as shown in Figure 4. Figure 4. Temperature Monitoring Circuit Copyright c 24 SERSC 263

3.3 Internal Resistance Measuring Principle This paper adopts the ac injection and phase lock amplifying way to measure the internal resistance [7-8], its principle analysis is shown in Figure 5. Figure 5. Internal Resistance Measuring Principle iagrams Overlay on the excitation signal for the square wave current signal at the ends of the, after partial pressure resistance of ac voltage signal it () is: 2E i( t) sin[(2n ) t i ] () n (2n ) Type: E as the amplitude, as the angular frequency, i for the current initial Angle. Battery voltage of ac response signal is: u( t) u '( t) n( t) 2U sin( t ) n( t) (2) Type: U as the response amplitude, u as at the beginning of the voltage phrase Angle, nt () for random noise signal. By the principle of phase-locked amplifier, the output signal yt () is: y( t) u( t) i( t) K cos{[ (2n )] t [ (2n ) ]} (2n ) (3) 2UE Type: K, after low pass filter, the output is: 2UEC Type: K, a i, K for of undetermined coefficients, C for the low-pass filter 2 gain value, R for internal resistance of the. Internal resistance of R is as follows: y( t) K2 cos KR (4) yt () R RZ K (5) In practice, through the use of standard resistance R to replace batteries (current value, frequency of excitation signal source remained unchanged) for the same test, undetermined coefficients K can be calculated: u 264 Copyright c 24 SERSC

So the internal resistance for R : K R y () t R (6) R y () t y() t (7) Type: R as had been standard resistance, y () t and yt () can be obtained by d/a converter. 4. The Upper Computer esign 4. atabase esign The construction of the database platform for the whole data access speed have a vital role, this module is to create a database platform, for the system to provide strong support. To collect data in real time to upload first place machine and through the display and the Internet for the user query, so that the operator in the early days of the degradation timely find fault source, avoid abnormal performance and to prevent voltage instability caused by similar to such problems as data loss. 4.2 Software esign Process start Initialize Communicate with single chip microcomputer The data processing ata results Save the Shared memory Whether to set a time? Yes ata memory S card No Communicate with touch screen Communicate with web servers The end Figure 6. PC Software esign Process Copyright c 24 SERSC 265

In the process of UPS of the remote monitoring technology research, single chip microcomputer as the master CPU from the machine in the form of implementation of monomer in the voltage, current, temperature and resistance performance parameters, such as real-time acquisition, through the way of combining eight-way inspection technology and interrupt, the collection of data stored in a specific ROM, when master MCU, after sending the communication instructions received from PC, enter the interrupt service routine, begin to collect and upload on cell performance parameters, and the PC to realize the data aggregation, analysis, processing and preservation, complete with LC display connection at the same time, the exception information and fault source, according to the timely for the operator to observe the pack in the actual running state of monomer, improve the efficiency of the single chip microcomputer PC software design process is shown in Figure 6. According to the software design process, in combination with C++ and database related technologies, this paper developed a UPS remote monitoring system, to achieve a friendly man-machine interface, among them, the real-time data display interface as shown in Figure 7. UPS remote monitoring system Battery State: charging Current: 2. A Voltage: 2. V Capacity: 66. Ah Step number: Cycle Number: Step cycle number: Time step: :5: Total time: :2: Charger State: run Current: 2. A Voltage: 2.6 V Capacity: 66. Ah Time step : :5: Total time: :2: UPS remote monitoring system Charger2 State: stop Current:. A Voltage:. V Capacity:. Ah Time step : :: Total time: :: Charger3 State: stop Current:. A Voltage:. V Capacity:. Ah Time step : :: Total time: :: Operation information The current step edit table information: Stop The current equipment start-up time: 23/3/3 4.3. Alarm Unit esign Figure 7. Software Interface Cell abnormal alarm module is through the design of fault diagnosis model, and through this model to realize real-time data was compared with the control limit, then realize the function of the host alarm and send SMS at the same time.. Battery anomaly diagnosis design In abnormal cells in the design of diagnosis, the host calls through the program realization and real time data in the database control limit (lower limit on voltage, current, etc.), if abnormal alarm host, at the same time to the designated mobile phone to send text messages, click on the alarm content in alarm module, analysis of fault type. 2. The text messaging function software design SMS cat LL interface provides the API function call interface, the interface completely low-level calls, no interface, suitable for the development of independent brands to the user. 266 Copyright c 24 SERSC

Function interface simple, only a few simple function call, can achieve the function of information sending and receiving, call structure diagram as shown in Figure 8: The user program Asp, C++, etc. The COM interface XxtSmsll. LL SMS model Stand-up, multi-port Figure 8. SMS MOEM Call Structure SMS cat through serial port (COM) is connected to a computer, or through the USB virtual serial port is connected to a computer. 5. Conclusion Based on the modular thought, UPS remote monitoring system for the overall design, solve the current real-time monitoring by a large number of human reality problem, and very good for getting failure batteries to make a report to the police. Practice has proved that through to the related hardware and software design, can achieve of monomer in UPS voltage, current, temperature and resistance monitoring, the fault information is the first time to operating personnel transfer, effectively reduce the accidents and guarantee the security, stability of power system. In addition, the system scalability is strong, can be based on group technology and cloud module technology such as extension for a wide range of remote monitoring. In this way, it can raise the automation level of UPS remote monitoring technology. Acknowledgements This paper is partially supported by Technological Innovation Foundation for Leaders of isciplines in Science of Harbin (24RFXXJ32). References [] H. Jiang, Accumulator cell intelligent on-line monitoring system for the research and design [], Harbin University of Science and Technology master's thesis, (27). [2] W. Ren, J. Li and X. Lin, UPS intelligent monitoring management and implementation [J], Shanghai, Journal of Shanghai institute of applied technology, vol. 7, no., (28), pp. 28-32. [3] X. Shu, Accumulator cell monitoring system research and development [], Hohai University master's degree thesis, (27). [4] R. Qi, Intelligent network UPS monitoring technology research [J], Power Technology, vol. 33, no. 7, (29). [5] L. Qin, MSP 43 Single-Chip Microcomputer application system development of typical examples [M], Beijing, China Electric Power Press, (25), pp. -58. [6] X. Li, X. Tang and Y. Huang, Single-chip microcomputer control system and several technical problems of communication between the microcomputer system [M], Electrical automation, vol. 6, (2), pp. 4-4. [7] J. Li and Y. Li, Accurate measurement of internal resistance method research [J], Battery, (26), pp. 28-29. [8] J. Lin, The design and implementation of internal resistance on-line monitoring system [], Hebei university of engineering, (2). Copyright c 24 SERSC 267

268 Copyright c 24 SERSC