WE70. FA Wireless LAN Unit. Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g



Similar documents
CQM1-SF200/CS1W-SF200

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

AC Wi-Fi Range Extender RE355. Highlights. Description

Concurrent 2.4 and 5 GHz Performance. Backward Compatible. Fast Roaming through 802.1X PMK Caching. Power over Ethernet Port. Secure Communications

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

5GHz 300Mbps a/n Wireless Outdoor Access Point

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

AP60. 9 Wireless. Wireless-b/g/n Long Range PoE Access Point. Wireless-b/g/n Long Range Radio. Passive PoE and 4-LAN Ports. IP Finder Management 4 LAN

Solid State Relays with Built-in Current Transformer

NEW PROXIMITY SENSORS E2B

EAP N Wall Mount Access Point / WDS AP / Universal Repeater

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

NX safety stand-alone

500M Powerline Pass-Through Ethernet Bridge

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Wireless N ADSL2/2+ Router

AirMax g High Powered Outdoor CPE. PoE. Simple All-In-One Solution. Long Distance Radio. Clear. 10dBi

Phase-sequence Phase-loss Relay

AC Wi-Fi Range Extender RE450. Highlights. Description

AC 750. Wi-Fi Range Extender RE210. Highlights. Description

WIB250A5 Series PC/ b/g/a/h WLAN Modules

Smart DeviceNet Remote I/O Terminals

Operating Instructions. Sophos Access Points

HP ProCurve Wireless Access Point 10ag Overview

750Mbps ac Wireless Broadband Router

AC Wi-Fi Range Extender RE580D. Highlights

How To Use The Cisco Aironet 1240G Series For A Wireless Network (Wired) And For A Wired Network (Wireless)

Original instructions Tina 3A/Aps Adaptor unit

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

EAP600 SOFTWARE FEATURES. Dual Band Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

AXIS T81B22 DC 30W Midspan

AC 750. Wireless Dual Band 4G LTE Router. Highlights

WBS210/WBS510 Datasheet

The software is sold on an AS IS basis. ALVARION, its affiliates or its licensors MAKE NO

300Mbps Wireless-N Access Point/Repeater

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

Waveguide Access Point WGA631. Product Guide

PoE+ Extender Switch User's Manual. Rev W

Solid State Relays for Heaters

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

ENHWI-N n Wireless Router

HP AP8760 Dual Radio a/b/g Access Point Overview

Moxa EtherDevice Switch

Smile 11 AS-i Emergency stop with safe AS-i input node

300Mbps. Wi-Fi Range Extender TL-WA855RE. Highlights. Description

PCMCIA Wireless LAN Card User s Manual

Introduction. - Please be sure to read and understand Precautions and Introductions in CX-Simulator Operation Manual and

Wireless Router Setup Manual

How To Read A Pipe From A Sensor

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Industrial n Wireless Access Point with PoE PSE

Telephone- and leased line modem for industrial applications TD-36

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

AC Wireless Dual Band Gigabit Router. Highlights

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Output Power (without antenna) 5GHz 2.4GHz

RSSI LED IP-67. Virtual. HTTPS WISP Bridge

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

EAP300. Long Range Ceiling Mount Access Point PRODUCT OVERVIEW

SPL 2-00/-01 OPERATION INSTRUCTIONS

Cisco Aironet 1520 Series Lightweight Outdoor Access Points

DTS/DRS-1000RV. Owner s Manual. DTS-1000RV: DVI/HDMI or VGA, Audio, RS-232C Transmitter Extender

ECB1220R. Wireless SOHO Router/Client Bridge

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

CABLE MODEM QUICK START

Safety Manual BT50(T) Safety relay / Expansion relay

WHA-5500CPE. 108 Mbps. 5GHz a Super Range Outdoor CPE. PoE. Long Distance Champion. All-In-One Solution. 25 Kilometers Distance or More

Quick Installation Guide of WLAN Broadband Router

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Table of Contents. Hardware Installation...7 Push Button Security Using the Setup Wizard Configuration...11 Main Security...

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

EPI-3601S Wireless LAN PCI adapter Version 1.2 EPI-3601S. Wireless LAN PCI Adapter. (802.11g & b up to 108 Mbps) User Manual. Version: 1.

Cisco Unified IP Phone Power Injector

Passive PoE Port. PoE WAN / LAN1

Terminal and Dimension

Long Reach PoE over Coaxial Extender Kit

16-Port and 24-Port 10/100 Switches

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Key Features. Multiple Operation Modes ENH500 can operate into four different modes with Access Point, Client Bridge, Client Router and WDS Mode.

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

1200Mbps ac Dual Band Wall Plug Wi-Fi Range Extender

Getting Started. Linksys RE1000 Wireless-N Extender

Demystifying Wireless for Real-World Measurement Applications

I STAR COMPUTER CO., LTD

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

HP Outdoor Bridge and Access Point Overview. Auto-MDIX: automatically adjusts for straight-through or crossover cables on all 10/100 ports

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Key Features. EnGenius Outdoor Base Station designs High Power, High Sensitivity and Strong Reliability Solutions under Harsh Environment.

g9sp Programmable Safety controllers compact Stand-Alone Programmable controller NEW! example of System configuration G9SP

Wireless N 300 Mini USB Adapter. Model # AWLL6086 User s Manual. Rev. 1.0

HDMI / Video Wall over IP Transmitter with PoE

ECB GHz Super G 108Mbps Access Point/Client Bridge/Repeater/WDS AP/

Setup guide. point to point wall plate extenders

Transcription:

New Product News FA Wireless LAN Unit WE70 Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802.11a/b/g Construct an Ideal Wireless LAN System for FA Applications!

The FA Wireless LAN Unit manages FA sites with 3 solutions Wireless LAN systems conforming to global standards. Conforms to IEEE 802.11a/b/g (5 GHz/2.4 GHz)! Nominal 54 Mbit/s high-speed communications! The WE70 Wireless Unit supports three Wireless LAN standards. The appropriate standard can be selected according to the environment or use of the FA system. General features of Wireless LAN standards Standards IEEE 802.11a IEEE802.11b Maximum speed Frequency band Modulation 54 Mbit/s 5-GHz band OFDM 11 Mbit/s 2.4 GHz band DS-SS Characteristics Five times faster than 11b. Noise resistant. Less cross talk with other devices. Multiple 8 channels can be used simultaneously. Wide selection of products. Long communications distance. Can be used outdoors. IEEE 802.11g 54 Mbit/s 2.4 GHz band OFDM Five times faster than 11b. Less vulnerable to obstacles. Compatible with 11b. Can be used outdoors Conformance to Radio Wave Standards Conforms to radio wave standards for USA, Europe, and China. USA: FCC part 15.247, 401-407 Europe: EN 300 328, EN 301 893 China: SRCC 2

Secure and easy to implement at FA sites. Stable operation even in harsh FA environments! The Wireless LAN Unit has the same level of noise and environmental resistance as OMRON FA Devices, such as PLCs and Power Supply Units. It is capable of stable operation when installed within the same control panel as other FA devices. There is no need to reset the power supply even if the Wireless LAN Unit runs out of control because it will automatically restart itself. Good noise resistance can be obtained by connecting the Wireless Unit to an OMRON Power Supply Unit. OMRON'S original security system prevents important production information from being disclosed. The latest encryption technology combined with OMRON'S original encryption technology forms a strong security environment. The FA Wireless LAN contains the following security features. Type of FA Wireless LAN Security and Effectiveness Security Access control Encryption Security level SSID Low MAC Address Filtering WEP WPA-PSK (TKIP/AES) OCB AES WOC KEY (OMRON'S original encryption) High : Very good, : Good, : Satisfactory, : Not very good Note: Partly quoted from the Wireless Security Guidelines (Ministry of Internal Affairs and Communications). Signal status can be observed! With the popular Received Signal Strength Indicator (RSSI), the status of invisible radio waves can be easily identified by checking the indicators. Received Signal Strength Level Stable Usable Unstable Unable to establish communications POWER RSSI LAN WIRELESS POWER RSSI LAN WIRELESS POWER RSSI LAN WIRELESS POWER RSSI LAN WIRELESS Versatile and easy installation! This Wireless LAN Unit can be easily installed anywhere on a DIN Rail or a wall. Install it in the control panel with other FA devices! Use magnets to mount it on metal surfaces! Screwless terminal block Easy connection to power supplies using the screwless terminal. Various antennas are available for different installation locations (optional). In addition to the included Pencil Antenna, the popular Magnetic-base Antenna is available. The FA Wireless LAN Unit can be installed inside the control panel and the Antenna on the outside of the control panel. Directional Magnetic-base Antenna Easy Installation 2.4-GHz/5-GHz Dual-band compatible Signal Direction from Antenna Signal range Side view Antenna Note: Cannot be used outdoors. Top view 3

Secure and easy to implement at FA sites. Prevents signal interference! Variable transmission power function! There are three transmitter output levels. By setting the level to low, you can reduce its influence on other systems within the same area, and more systems can be added. High transmitter output Low transmitter output (See note.) Note: The transmission distance will be shortened. Signal interference! Maintains good security. Setting Tool FA Wireless LAN settings can be made from a remote location! Settings can be managed from a WEB browser. Specific software tools are not required. The status of the FA Wireless LAN can be checked from the control room. AP Settings Window CL Settings Window 4

Diverse systems to match applications. Large quantities of production data can be managed as a batch. Up to 63 clients can be connected to one access point. Communications between access points enables switching of access points when expanding the communications area or when there is a communications error. Ethernet PLC or Computer Up to 6 access points can be registered with one Wireless LAN Unit Communications between Access Points (The access point becomes the repeater to extend the communications area.) WE70-AP Access point Communications between Access Points (Maximum of 6 repeaters) WE70-AP Access Point (repeater) WE70-CL Client Ethernet 63 clients max. PLC The roaming function allows systems to be moved and communicate with mobile devices. Note: Make sure that you read the Wireless LAN Unit Operation Manual (Cat. No. N153) and check the operating conditions on site before using the roaming function. WE70-AP Access Point (Master) WE70-AP Access Point (Master) WE70-AP Access Point (Master) WE70-CL Client (Slave) Automatically switches to the next access point 5

FA Wireless LAN Unit WE70 Highly reliable performance. Ideal Wireless LAN for FA sites. Conforms to IEEE 802.11a/b/g. Same noise and environment resistance level as a PLC. Features OMRON'S original security system. Signals can be observed with LED indicators. The Wireless LAN Unit can be installed inside a control panel and the Antenna outside the control panel. RoHS-compliant. Conforms to radio wave standards for the USA, Europe, and China. Ordering Information Wireless LAN Unit Area Type Model Europe Access Point (Master) WE70-AP-EU Client (Slave) WE70-CL-EU USA Access Point (Master) WE70-AP-US Client (Slave) WE70-CL-US China Access Point (Master) WE70-AP-CN Client (Slave) WE70-CL-CN Note: 1. Includes a Pencil Antenna, magnets for mounting the Wireless LAN Unit, and a mounting bracket. 2. Make sure that the correct model for the area is used. For example, the use of the WE70-AP-US in an area other than the USA is illegal as stipulated in laws and regulations. Accessories Antenna Other Type Specifications Model Directional Magnetic-base Antenna 1 set with two Antennas, 2.4 GHz/5 GHz Dual-band compatible Type DIN Rail Mounting Bracket (for TH35 7.5) DIN Rail Mounting Bracket (for TH35 15) Antenna Extension Cable (5 m) WE70-AT001H Model WT30-FT001 WT30-FT002 WE70-CA5M Accessories Type Model Details PLC SYSMAC CS1/CJ1 Series Ethernet Unit CS1/CJ1W-ETN21 100Base-TX type Switching Hub Phoenix Contact FL SWITCH 5TX Power Supply Unit S8VS, S8VM Series 24 VDC, 30 W min. Conformity to EN Standards Use a DC power line less than 3 m in length to conform to EN standards. If a power line of 3 m or longer is required, extend the length at the Switching Power Supply's primary side (i.e., the AC power line). Conformity to Safety Standards Always use a Class 2 power supply to conform to UL standards. Main OMRON Class 2 Switching Power Supplies S8VS (30 W, 60 W type) 6 FA Wireless LAN Unit WE70

Specification Ratings Model WE70-AP Access Point (Master) WE70-CL Client (Slave) Item Power Rated voltage 24 V DC supply Allowable 20.4 to 26.4 V DC voltage range Current 250 ma max. (See note.) consumption Insulation resistance 20 MΩ min. (at 100 V DC) between the power supply and mounting bracket Dielectric strength 1,500 V AC for 1 min between power supply and mounting bracket Noise immunity IEC 61000-4-4. 1 kv (power supply line) Vibration resistance JIS C0040 Frequency: 10 to 55 Hz; Amplitude of 0.35 mm or acceleration of 50 m/s 2, whichever is smaller 10 sweeps of 8 min each (i.e., 80 min in total) in X, Y, Z directions Shock resistance Conforms to JIS C0041: 300 m/s 2 3 times each in X, Y, and Z directions Ambient operating 0 to 50 C (with no condensation) temperature Ambient operating humidity 25% to 85% (with no condensation or icing) Ambient storage 20 to 65 C temperature range Degree of protection IP20 Terminal construction Power terminal Applicable Standards Weight Screwless terminal block (Phoenix Contact AI 0.75-10 or equivalent) FCC, UL (USA), CE Marking (EU), Chinese Electromagnetic Standards (Mainland China) 360 g max. (Wireless LAN Unit only) Note: Provide a power supply of at least 30 W, considering the inrush current generated at startup. Wireless Interface Specifications Item Standards Conforms to IEEE 802.11a Conforms to IEEE 802.11b Conforms to IEEE 802.11g Wave type Orthogonal Frequency Division Multiplexing (OFDM), Simplex Direct Sequence Spectrum Spread, Simplex Orthogonal Frequency Division Multiplexing (OFDM), Simplex Frequency band Refer to the following Frequency Bandwidths and Channels by Area on page 8. Number of channels Refer to the following Frequency Bandwidths and Channels by Area on page 8. Baud rate (See note 1.) Maximum Transmission Distance (Line of Site) (See notes 2 and 3.) Auto or 54, 48, 36, 24, 18, 12, 9, or 6 Mbps Indoors: Approx. 40 m (with enclosed Pencil Antenna at 54 Mbps) (Outdoor use prohibited.) Auto or 11, 5.5, 2, or 1 Mbps Note: 1. Theoretical value of the Wireless LAN Standards, not the actual baud rate. 2. Depends on the installation environment. 3. The distance will be shorter when using a Magnetic-base Antenna or an extension cable. Auto or 54, 48, 36, 24, 18, 12, 9, or 6 Mbps Indoors: Approx. 60m (with enclosed Pencil Antenna at 54 Mbps) Security OCB AES (128 bit), WEP KEY (OMRON'S original encryption), WEP (64/128/152 bit), WPA-PSK (with AES <128 bit>/tkip <128 bit> encryption) Transmitter output power 10 mw/mhz max. No. of connected clients 63 max. Variable transmission power Roaming function Repeater function 3 levels: (High/Mid/Low) If high communications distance is 100%, medium is 50%, and low is 25%. (See note 2.) Provided Provided (Communications between access points, 6 repeaters max.) FA Wireless LAN Unit WE70 7

LAN Cable Specifications Item Parameter Standards Conforms to IEEE 802.3 (10Base-T, 100Base-TX) Interface RJ-45 1 Other Item Wireless LAN Unit Setup Specification Web browser: Microsoft Internet Explorer 6.0, 7.0, or higher OS: Windows Vista, XP, or 2000 (See note.) Note: Connect to computer using a straight cable. Note: Not compatible with Windows 98, NT, or Me. Frequency Bandwidths and Channels by Area 11a (5 GHz band) 11b/g (2.4 GHz band) Frequency (MHz) Area USA (24 channels total) Europe (19 channels total) China (5 channels total) 5150 5350 5470 5725 5825 8 ch 11 ch 5 ch 8 ch 11 ch 5 ch Frequency (MHz) Area USA (11 channels total) Europe (13 channels total) China (13 channels total) 2412 2462 2472 11 ch 13 ch 13 ch 8 FA Wireless LAN Unit WE70

Nomenclature Access Point (Master) WE70-AP(-EU/-US/-CN) INIT Button Used to operate using default settings. Antenna Connector Used to connect enclosed Antennas. Note: To ensure good performance, always connect both of the Antennas. LAN port (RJ-45 1) Connect a network device, such as a hub, through a LAN cable. DC Connector Supplies 24 VDC power. Access Point Indicator Indicator Color Status Meaning (primary error) POWER Green Lit Power ON Not lit Power OFF Flashing Simultaneous flashing of MODE and POWER indicators shows that the setup is being initialized. (See note.) MODE Orange Lit Using IEEE 802.11a Not lit Using IEEE 802.11b/g Flashing Simultaneous flashing of MODE and POWER indicators shows that the setup is being initialized. (See note.) WIRELESS Orange Lit Radio communications are being established with the Wireless LAN client. Not lit There is no LAN Client communicating with the Wireless Unit, or no radio communication has been made for 5 minutes or more. LAN Orange Lit LAN connection is normal. Not lit LAN is not connected. Flashing Data is being transmitted. POWER Indicator (Green) Displays the power source status and the operation mode of the Wireless LAN Unit. MODE Indicator (Orange) Displays the operating mode of the Wireless LAN Unit. Client (Slave) WE70-CL(-EU/-US/-CN) RSSI Button Switches the received signal status indicator to flashing or four-level lit display. INIT Button Used to operate using default settings. POWER Indicator (Green) Displays the power source status and the operation mode of the Wireless LAN Unit. RSSI Indicator (Orange) Displays the received signal strength by flashing. WIRELESS Indicator (Orange) Displays the status of the Wireless LAN LAN Indicator (Orange) Displays the status of the wired LAN. Antenna Connector Used to connect enclosed Antennas. Note: To ensure good performance, always connect both of the Antennas. LAN port (RJ-45 1) Connect a network device, such as a hub, through a LAN cable. DC Connector Supplies 24 VDC power. WIRELESS Indicator (Orange) Displays the status of the Wireless LAN. LAN Indicator (Orange) Displays the status of the wired LAN. Note: When the RSSI Button on the back of the WE70 is pressed, the received signal strength will be indicated using the POWER, RSSI, LAN, and WIRELESS indicators. The POWER indicator will flash. Press the button again or wait for 10 minutes of the indication to pass and then the indication will return to the original status. Note: Hold down the initialization switch while the power is OFF and then turn the power ON without releasing the switch. Initialization can also be applied from the settings window using a web browser. Client Indicator Indicator Color Status Meaning (primary error) POWER Green Lit Power ON Not lit Power OFF Flashing Simultaneous flashing of the RSSI and POWER indicators shows that the setup is being initialized. (See note.) RSSI Orange Not lit No margin Flashing Level 1, duty 2 (OFF): Flashes for 1 (ON) Flashing Level 2, duty 1 (OFF): Flashes for 2 (ON) Lit Level 3 Flashing Simultaneous flashing of MODE and POWER indicators shows that the setup is being initialized. (See note.) WIRELESS Orange Lit Radio communications are being established with the Wireless LAN Access Point. Not lit There is no wireless LAN Access Point communicating with the Wireless LAN UNIT, or no radio communication has been made for more than 10 seconds. LAN Orange Lit LAN connection is normal. Not lit LAN is not connected. Flashing Data is being transmitted. Note: Hold down the initialization switch while the power is OFF and then turn the power ON without releasing the switch. Initialization can also be applied from the settings window using a web browser. FA Wireless LAN Unit WE70 9

POWER MODE LAN WIRELESS Dimensions Note: All units are in millimeters unless otherwise indicated. Access Point (Master) WE70-AP(-EU/-US/-CN) Client (Slave) WE70-CL(-EU/-US/-CN) Using Pencil Antenna (129.6) (26.6) 37.2 37.2 22.6 (231.5) (128.5) 107.6±1.0 WE70-AP FA WIRELESS LAN A CCESS POINT 103±1.0 103 34.5±0.5 (36) 120±1.0 38.5 12 Mounting Bracket Mounting Bracket 120 108±0.1 6 116±.0.2 Note: Leave a gap of approx. 20 mm around the sides of the Wireless LAN Unit for ventilation. 6 Four, 4.2-dia. holes (Use flat head screws) Four, 5-dia. holes 1.5 Directional Magnetic-base Antenna WE70-AT001H 11 25 DIN Rail Mounting Bracket WT30-FT001 (for TH35 7.5) WT30-FT002 (for TH35 15) Reference: Applicable DIN Rail Section A Detail of section A for TH35 7.5 7.5 0.4 0 Detail of section A for TH35 15 15 1±0.04 193 35±0.3 1±0.04 15 0.3 max. 22 78 2,000±2 82.6 10 FA Wireless LAN Unit WE70

Read and Understand this Catalog Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the product in the customer's application or use of the product. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to the product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.

Note: Do not use this document to operate the Unit. OMRON Corporation Industrial Automation Company Control Devices Division H.Q. Network Devices Department Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: (81)75-344-7109/Fax: (81)75-344-7149 Regional Headquarters OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel: (31)2356-81-300/Fax: (31)2356-81-388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, Pu Dong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Authorized Distributor: Note: Specifications subject to change without notice. Cat. No. N154-E1-01A 1007