Subj: SEWAGE SPILL RESPONSE, REPORTING, AND MANAGEMENT



Similar documents
Contractor Signature: Title:

GUIDANCE FOR DEVELOPMENT OF SPILL AND SLUG PREVENTION CONTROL PLANS AND FACILITIES FOR THE CITY OF ATTLEBORO SEWER USERS

DRAFT Public Outreach Document for What s an SSMP?

Tim Schneller, P.E. GBA Engineers and Architects

Element 3: OVERFLOW EMERGENCY RESPONSE PLAN

Sanitary Sewer Overflow Response Plan Working Committee SANITARY SEWER OVERFLOW RESPONSE PLAN

Addressing SSOs in Austin, Texas: Initial Call to Final Fix

FUEL STORAGE ABOVE GROUND STORAGE TANKS

City of Mebane Wastewater Collection and Treatment Facility

City of Bakersfield Public Works Department Sewer System Management Plan December 2014

Unauthorized Discharges and Sanitary Sewer Overflows

ecmar SECTION INSTRUCTIONS: Sanitary Sewer Collection Systems

The Clean Water Project What Is The Stormwater Impact?

BEST ENVIRONMENTAL MANGEMENT PRACTICES

Fat, Oil and Grease Grease Traps & Environmental Compliance. What restaurants need to know about Sewers & Water Supply By-laws

Routine Maintenance and Inspection

SILICON VALLEY CLEAN WATER. May 2015

DRAFT Guidelines for Manually Diverting Outdoor Wastewater to the Sanitary Sewer

DEPARTMENT OF THE NAVY RECORDS MANAGEMENT PROGRAM

FOOD SERVICE FACILITIES Best Management Practices Stormwater Management Program City of Bluff City P.O. Box 70, Bluff City, TN

Managing Floor Drains and Flammable Traps

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

Almonte Sanitary District Sewer System Management Plan Adopted by the ALMONTE Board of Directors on_08/28/06

AMERICAN BOTTOMS REGIONAL WASTWATER TREATMENT FACILITY BID AB SLUDGE LOADING, HAULING & DISPOSAL TECHNICAL SPECIFICATIONS

CITY OF POMONA SANITARY SEWER OVERFLOW EMERGENCY RESPONSE PLAN

Sanitary Sewer Overflow(SSO)/Bypass Notification Form Instructions

SPILL CONTAINMENT AND CONTROL PLAN

Monterey Regional Water Pollution Control Agency. Sewer System Management Plan

Florida Department of Environmental Protection

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

History of the SPCC Rule

PEST MANAGEMENT ISSUES & LANDLORD- TENANT RELATIONSHIP

City of Green Bay Department of Public Works Engineering Department

Understanding Your An Introduction to the Chicago Area s Combined Sewer Systems

PREVENTING WET OR FLO ODED BASEMENTS

Fats, Oils and Grease

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

Combined Sewer Overflows in the Milwaukee Metropolitan Sewerage District Conveyance and Treatment System

Best Management Practices Fats, Oils, & Grease

UNIVERSITY OF CALIFORNIA, DAVIS MEDICAL CENTER SANITARY SEWER MANAGEMENT PLAN. UCDMC Sanitary Sewer Management Plan 1

How Your Business Can Prevent Stormwater Pollution

SPCC for Food Services

Moisture Management. Infection Prevention and Corporate Safety. Contents. Posttest... 12

POLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE

Village of St. Louis Sewer Back-up Policy

Essential Water. Customer Charter

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

City of Hillsboro Inflow and Infiltration Elimination Program

There are many examples of sensitive information falling into the wrong hands. What s the worst that can happen? The worst has already happened.

Clean Water: Supply side potable water, not wastewater. Gray Water/Sewage: Wastewater originating from a drain (sink, toilet, urinal).

Fats, Oils and Grease. Educational Kit

Spill Prevention, Control and Countermeasure (SPCC) Training

Sanitary Sewer Overflow Report Form

What Is An On-Lot Sewage Disposal System?

Fats, Oil and Grease. Best Management Practices Manual. Information, Pollution Prevention, and Compliance Information For Food Service Facilities

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

CASE STUDY Hanjiang Dafu Shoe Company & Putian Hanjiang Shoe Company

Code Compliance Guideline: Swimming Pool Chemicals

RULES AND REGULATIONS OF THE BOARD OF DIRECTORS OF INLET WATCH YACHT CLUB, INC Revised July 2014

Spill Prevention, Control and Countermeasure (SPCC) Rule

D E P A R T M E N T O F THE NAVY

Good Housekeeping Practices for DPW/Fleet Maintenance Facilities

Emergency Response Plan

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

Compliance Guidance for Motor Vehicle Waste Disposal Wells in Oregon September 2015

Ann Arbor Wastewater Treatment Plant Facilities Renovations Project September 2015

Georgia Department of Public Health. Georgia Onsite Sewage Management Systems. Background and Use of Onsite Wastewater Treatment Systems in Georgia

MCBO B B Aug 07. Subj: HANDLING, TRANSFER, AND DISPOSAL OF HAZARDOUS MATERIALS AND HAZARDOUS WASTE

Number September 2014 SEWER LIABILITY

University of California Santa Cruz

PART 6 - STANDARD DESIGN AND CALCULATION FORMS 6.1 SANITARY SEWER DATA SHEET

CITY OF PINOLE SEWER LATERAL ADMINISTRATIVE GUIDELINES

How To Prevent Grease From Getting Into The Water System

Fats, Oils, and Grease Best Management Practices Manual

DEPARTMENT OF THE NAVY HEADQUARTERS UNITED STATES MARINE CORPS 3000 MARINE CORPS PENTAGON WASHINGTON, DC

Sanitary District No.5 of Marin County SSMP

John J. Cronley Marketing Communications Manager Mission Communications , x1008

City of Chico Sanitary Sewer Overflow Response Plan (Appendix D of the City of Chico Sewer System Management Plan)

Transcription:

UNITED STATES MARINE CORPS MARINE CORPS BASE QUANTICO, VIRGINIA 22134-5001 6280 B 046 28 Jun 04 COMMANDER S POLICY LETTER 2-04 From: Commander Subj: SEWAGE SPILL RESPONSE, REPORTING, AND MANAGEMENT Ref: (a) 33 U.S.C. 1251 Encl: (1) Form MCB 6280/1 (6/04)(EF), Sewage Spill Response (2) Form MCB 6280/2 (6/04)(EF), Spill Management Information 1. Information. The reference, Clean Water Act, requires that every effort be made to stop, contain, and cleanup sewage spills. The policy and procedures outlined in this letter will be followed by anyone causing or discovering a sewage spill or overflow anywhere aboard MCB, Quantico. 2. Policy. It is the policy of this Command to prevent sewage spills/overflows to the maximum extent possible by aggressively maintaining both the collection system and the wastewater treatment plant. In the event a spill or overflow does occur, timely response and accurate reporting will be accomplished. 3. Reporting. The following procedures will be followed when reporting a spill: a. If the spill is discovered within the housing area, residents are to immediately notify Lincoln Property Management at 1-888-578-4141 who will respond to the spill. Lincoln Property Management will immediately notify the mainside Waste Water Treatment Plant (WWTP) at 703-784-2147, and promptly provide the WWTP all details required to complete form MCB 6280/1 (6/04)(EF), Sewage Spill Response, enclosure (1). If the spill is beyond Lincoln s scope of responsibility, they will notify the Facilities and Logistics Support Services (FLSS) trouble desk at 703-784-2072 for repairs and/or cleanup. b. If the spill is discovered in any other area of the base, immediately notify the FLSS trouble desk for repairs and/or cleanup. The trouble desk and the responding shop will notify the WWTP and provide all details required to complete enclosure (1).

Subj: SEWAGE SPILL RESPONSE, REPORTING, AND MANAGEMENT c. Whether notified by Lincoln Property Management, if in housing, or by someone else discovering the spill anywhere on base, the FLSS trouble desk will immediately contact the shop responsible for responding to the spill. The FLSS trouble desk will also notify the Natural Resources and Environmental Affairs (NREA) Branch at 703-784-4030 should there be a spill in progress. d. During working hours, the WWTP will fill out enclosure (1) and send a copy to the NREA Branch. The NREA Branch will call the Virginia Department of Environmental Quality to report the spill within 24 hours of spill occurrence, as required by law. e. During weekends and after hours, the WWTP will report the spill to the Virginia Department of Emergency Response at 1-800-468-8892 within 24 hours of the spill. The WWTP will provide a copy of enclosure (1) to the NREA Branch, and will notify the NREA Branch the morning of the next business day. 4. Response. Response to any sewage spill or overflow must be immediate. The response consists of seven elements: a. Stop the flow. b. Contain the discharged liquids. The spill must be contained to prevent it from reaching drains or any bodies of water. If possible, pooled sewage will be pumped back into the sanitary system. c. Report the spill. When reporting spills, the following information must be provided: (1) Date and time spill was discovered. (2) Date and time spill was stopped. (3) Location of spill (street and bldg number). (4) Estimated gallons of sewage discharged. (5) Cause of discharge. (6) Corrective actions taken. (7) Any noticeable effects to the environment. 2

Subj: SEWAGE SPILL RESPONSE, REPORTING, AND MANAGEMENT (8) Name of the waterway affected. (9) Shop in charge of cleanup, and point of contact. d. Clean up and sanitize the site. e. Repair the cause of the spill/overflow, if applicable. f. Analyze the cause. It is imperative that spills do not reoccur. Each and every spill must be analyzed to determine if it is a one-time event or if it will continue to occur. FLSS or Lincoln Property Management must provide NREA Branch with the information required to fill out form MCB 6280/2 (6/04)(EF), Spill Management Information, enclosure (2). g. Adjust procedures/take permanent corrective actions as needed. 5. Forms a. Form MCB 6280/1 (6/04)(EF), Sewage Spill Response, is provided electronically on the FormFlow server and in enclosure (1). b. Form MCB 6280/2 (6/04)(EF), Spill Management Information, is provided electronically on the FormFlow server and in enclosure (2). DISTRIBUTION: INTERNET J. M. LOWE 3

SEWAGE SPILL RESPONSE ENCLOSURE (1) 1

SPILL MANAGEMENT INFORMATION ENCLOSURE (2) 1