Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 1)



Similar documents
Personna PC web-based software. Q-AdminTM client. Lighting management hub (floor 2) Lighting management hub (floor 1)

Application Note #563 Revision A November 2015 Lutron / Automated Logic BACnet Integration

Application Note #231 Revision B November Using a VPN Connection to Remotely Access Lutron Systems. Overview. Key Terms. Before You Begin...

Application Note #402 Revision B November 2014 Energi Savr NodeTM System Wireless Networks

Application Note #231 Revision E February 2015

Technology Support Plan: Silver Level (LSC-SILV-IW)

Application Note #537 Revision D August 2015 Solutions for Upgrading from HomeWorks Illumination to HomeWorks QS

ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance

Tracer Summit Web Server

Increase your revenue with Caséta Wireless Simple, reliable, affordable lighting control

SECTION INTEGRATED AUTOMATION SOFTWARE FOR CONTROL OF MONITORING NETWORKS

Control System - Enterprise Integration HVAC Concepts, Inc. (2005)

It's All About HVAC Systems and Saving Big Bucks Using DDC Systems!

EC-Net AX Supervisor with 0 Niagara network connections - for. EC-Net AX Supervisor with 100 Niagara network connections. Includes

Temperature Control from Lutron

Supporting ANY PRODUCT employing

Product Catalog. Tracer SC System Controller For Tracer Building Automated Systems BAS-PRC031-EN. July 2010

Enterprise Facility Management Software

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

BACnet protocol implementation conformance statement. Corrigo

A Systems Approach to HVAC Contractor Security

Medical Vacuum Systems-PXMI

Meet the New Standard. in Building Management Solutions for Commercial Buildings

Smart Integration of Wireless Temperature Monitoring System with Building Automation System

Easily Connect, Control, Manage, and Monitor All of Your Devices with Nivis Cloud NOC

Quantum Total Light ManagementTM. Architectural Lighting Control, Shading, and Energy-Saving Solutions

Comprehensive Data Center Energy Management Solutions

Is there an affordable building automation system I can customize to meet my needs?

NETWORKING AND INTEGRATION

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Integrated Building Management and Security System. Building Automation & Security.

How To Use The Lutron Home Control+ App On An Ipad Or Ipod

Lutron Services Catalog

Smart Anytime, Safe Anywhere. Climax Home Portal Platform. Envisage and Enable a Connected Future

SAUTER novapro Open: B-AWS. BACnet Advanced Workstation

Comprehensive Data Center Energy Management Solutions

IP Based Control for Mechanical and Electrical Systems in an Enterprise Environment

Essential Curriculum Computer Networking 1. PC Systems Fundamentals 35 hours teaching time

It s all open from here.

Tim Sisson - Trane HVAC OVERVIEW

Square D Powerlink G3 Lighting Control Systems

Remote Management White Paper 27th June, 2012

Niagara IT Manager s Guide

Cylon energy Solution

Using Cisco UC320W with Windows Small Business Server

ControlMaestro and. BACnet integrated solution

KNX for building and room automation simple and efficient

Building Technologies

Smart Communications for Small and Medium Business. UC Suite for UNIVERGE SV9100

Affordable Building Automation System Enabled by the Internet of Things (IoT)

UC Suite FOR UNIVERGE SV9100. Smart Communications for Small and Medium Business. necam.com

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

SYSTEM COMPONENTS. Gateway. Sensors. Repeater Figure 1

Integrated Building Management and Security System. Building Automation & Security.

Advanced Solar Solutions

OptiView. Total integration Total control Total Network SuperVision. Network Analysis Solution. No one knows the value of an

OptiView. Total integration Total control Total Network SuperVision. Network Analysis Solution. No one knows the value of an

UC Suite FOR UNIVERGE SV9100. Smart Communications for Small and Medium Business. necam.com

Planning BACnet networks

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

Table of Contents. Introduction. Understanding PBX systems. Hosted PBX advantages. Features offered by a hosted PBX service

Agilent U2000 Series USB Power Sensors

BUILDING AUTOMATION & CONTROLS, BUILDING AUTOMATION & CONTROLS, WHAT S NEW & WHAT WILL THE FUTURE BRING? WHAT S NEW & WHAT WILL THE FUTURE BRING?

Secure Communication Made Easy

CenterMind G+ Smart and Proactive Environment Monitoring

Networking Basics for Automation Engineers

Configuring an APOGEE System on an IT Infrastructure White Paper

OPENweb. Efficient controlling at the highest level.

Smart. Scalable. Simple.

Retail & Commercial Solutions. Siemens EcoView. Energy Management Made Easier.

Overture ENTERPRISE CLASS A/V CONTROL. Reduce complexity and cost with a software based A/V control

GlobalViewer Enterprise

SAUTER BACnet PICS EY-modulo 5 moduweb500 BACnet Protocol Implementation Conformance Statement

How To Learn To Use A Trane Building Control System

Smart Anytime, Safe Anywhere. Home Passport Gateway-G Series. The Epitome of Smart Living

Power & Environmental Monitoring

Gauge Drawing Tool Slider Drawing Tool Toggle Button Drawing Tool One-Way List Drawing Tool... 8

SAUTER EY-modulo 5. The complete building management solution

savic-net for Integrated Building Management System

Insight Advanced Workstation

Summer 2013 Cloud Initiative. Release Bulletin

Schneider Electric and Energy Efficiency

GlobalViewer Enterprise

Chapter 1 Personal Computer Hardware hours

Cisco Conference Connection

scalable data centre energy management solution

Think Automation and beyond... IDEC WindSRV. KEPServerEX OPC Server

Semaphore T BOX Applications in Data Center Facilities

Commercial Solutions

HREP Series DVR DDNS Configuration Application Note

Tracer Summit Energy Services

Finding Lutron Processors on a Network

Honeywell Enterprise Buildings Integrator. Maximise productivity, compliance and flexibility while reducing costs and risk

Product Catalog. Trane eview Energy Reporting Software BAS-PRC054-EN. November 2010

ShareLink 200 Setup Guide

Technology Spotlight on Cellular Data Networking for SCADA system networks. Presented by Teamwork Solutions, Inc.

Transcription:

Lutron / Trane BACnet Integration Application Note #523 Revision A August 2014 Quantum Overview GreenGlance client Personna PC web-based software ipad with Q-Control+ app Corporate Building Network Quantum server Q-AdminTM client BMS Integration Lighting management hub (floor 2) Lighting management hub (floor 1) The Lutron Quantum system is the total light management system that incorporates lighting controls, motorized window shades, digital ballasts and LED drivers, centralized dimming and switching panels, and sensors together under one system/software umbrella. It is a processor-based system and the processor(s) reside in the hubs shown in the diagram above. In a typical building, you will typically have at least 1 hub per floor connected over the building network or a dedicated network for the lighting system. Quantum can seamlessly and reliably integrate with other building systems. The BACnet /IP protocol is the primary means of integration. BACnet is embedded or native in the Quantum processors, which means no external interfaces or gateways are required in order to communicate with other systems. Only a single point of connection is needed on the Quantum network for total and complete communication to the entire system. The diagram above shows a Quantum server. The server is used for historical data logging for the reports used in the Quantum software. It is NOT required for BACnet integration. Only a Lighting Management Hub is required. Additionally, the Quantum system has been tested by BACnet Testing Laboratories (BTL) and is certified to comply with all of their necessary interoperability requirements. ipad is a trademark of Apple Inc., registered in the U.S. and other countries. BACnet is a registered trademark of ASHRAE. ASHRAE does not endorse, approve or test products for compliance with ASHRAE standards. Compliance of listed products to the requirements of ASHRAE Standard 135 is the responsibility of BACnet International (BI). BTL is a registered trademark of BI. 1 Technical Support 800.523.9466

Tracer System Overview Trane Technician PC with Tracer TU Customer PC with Web Browser Ethernet WAN / LAN BACnet / IP Tracer SC Intellipak (I or II) LCI-I Multi-Purpose Tracer MP581 Lon Talk BACnet MS / TP (wired and wireless) Intellipak (I or II) BCI-I ReliaTel Equipment LCI-R VAVs Tracer V V550 VAVs Tracer UC400 Chiller Equipment with Tracer Controls Unitary Controller Chiller Equipment with Tracer Controls Tracer SC Tracer SC system controller is a powerful, scalable, web-enabled building controller built on open, standard protocols. Tracer SC features Trane EarthWise applications and interfaces for air and water systems to ensure optimal system performance from job to job. The flexible and scalable capacity of Tracer SC allows it to be applied in a variety of facility types and sizes. The embedded web server provides an easy to use interface for basic and advanced users of the system. Most LonTalk and BACnet unit controllers and system controllers are compatible with Tracer SC, including all Trane unit controllers that support these protocols. Tracer SC allows you to streamline facility management without reinventing the entire system. Adding Tracer SC to your system provides a flexible, cost effective solution for building automation, and managing the facility climate that can extend to lighting and energy consumption. Accessible from most PCs, tablets and smart phones, Tracer SC eliminates the need for a dedicated computer and monitor so you can manage system performance whenever and wherever it is convenient. Tracer SC controller s simplified, Web-based management tool reduces scheduling, reporting and system application chores to simple point and click tasks. The intuitive online tools provide improved efficiencies, increased tenant comfort and reduced energy costs, which result in operational cost-savings and a better bottom line. 2 www.lutron.com

Tracer ES Tracer ES is a web-based building automation system (BAS) that dramatically simplifies the complex requirements of managing and operating multiple facilities. Accessible from most PCs, tablets, and smart phones, Tracer ES provides immediate access to your building systems from virtually any location, allowing you to maintain comfortable, healthy conditions and satisfied occupants. Tracer ES simplifies the management of building systems within multiple facilities for owners, managers, and daily operators. Tracer ES provides centralized management of scheduling and alarms, supports long-term data storage to document and monitor performance, enables remote troubleshooting, and brings disparate systems together for upgrade flexibility. Because Tracer ES offers full browser support, you can access your facility from wherever you are from your PC, tablet, or smart phone. 3 Technical Support 800.523.9466

Integration Overview Trane Tracer System Insight and Trane Tracer System BACnet Field Panels can be used to monitor and control the Lutron Quantum system using the BACnet protocol. The BACnet protocol is a non-proprietary open communication software standard published by ASHRAE. Topology Tracer ES Trane System Controller (SC) Tracer ES Building Ethernet BACnet /IP Quantum Hub Communication Protocol Communication between Trane Tracer System and Lutron is BACnet /IP BACnet /IP uses Broadcast UDP and Peer-to-Peer UDP on any standard Ethernet network BACnet Testing Laboratories Listing Trane and Lutron devices are BTL Listed: Trane System Controllers (SC) are BTL-Listed as B-BC Lutron Quantum Lighting Control System is BTL-Listed as B-ASC 4 www.lutron.com

How to Set Up Integration: Application Note #523 What needs to be done in the Lutron Quantum system 1. BACnet is native to the Quantum processor. However, in order to enable this capability, a BACnet software license must be purchased for the job. 2. With the BACnet software license, the Lutron service representative will turn on the BACnet capability using the DeviceIP setup software tool. Only one processor per subsystem will be enabled. This processor will act as the master for all BACnet communications for the subsystem. 3. Each area cannot exceed 400 Virtual objects. 4. If the Quantum processor and Trane Tracer System systems are not on the same subnet, a BACnet Broadcast Management Device (BBMD) is required by the integrator. The Quantum processor supports foreign device registration of BBMD. The IP address of the BBMD should be given to the Lutron field service representative during setup (if required). The Tracer SC System Controller supports BBMD. 4. The Lutron BACnet virtual network will need to be set to a different BACnet network number than the BACnet / IP network the Trane and Lutron systems are connected to. Coordinate with the Trane representative on-site. What needs to be done in the Trane Tracer system 1. Virtual devices within the Trane system can have a maximum object count of 400. 2. A Tracer SC should be purchased for Scheduling, Trending, and Alarming functionality. What to Integrate: Data sharing: Lutron exposes lighting objects as Analog objects, Binary objects and Multi-State objects. This allows Trane applications like Trane Tracer ES System Graphics and Trane Tracer SC System to use BACnet services to monitor and command the lighting objects. Most devices and objects from the Lutron system are virtual BACnet objects. Virtual devices are area-based so they correspond to a geographical area of the building (e.g., conference room, private office, etc.). Virtual device names are job specific and created at the time of Lutron database creation, which is done in-house at Lutron Headquarters just prior to startup. To simplify the integration process, it is recommended that the integrator and Lutron field service representative coordinate on area naming conventions. For a summary of Lutron BACnet objects, naming conventions, and functionality, reference the additional tables located in the Lutron BACnet PICS statement. To get the latest PICS statement that corresponds to the Quantum software version you are running, contact any Lutron representative or find them at www.lutron.com/quantum under the Product Specification Submittals section and go to BACnet Scheduling Lutron does not currently support the BACnet Schedule Object. There are two approaches that can be employed for scheduling the lighting system. Approach 1: The Trane Tracer System supports the Schedule which can be used to directly command the Lutron lighting objects. The Schedule can be viewed and modified using Trane Tracer System Scheduler application. Approach 2: The Lutron Quantum system can support the schedule and the Quantum Q-AdminT software can be used to view and modify events. The Trane Tracer System can enable/disable an entire timeclocks, per subsystem, through BACnet binary objects. BACnet Trending Lutron does not support the BACnet Trend Log object. However, the Lutron system does share information (power usage, occupancy, etc.) through Binary, Analog, and Multi-State objects, which can be used for trending. The Trane Tracer system supports the Trend Log object which can trend the Lutron lighting objects. The Trend Log object data can be archived with the Tracer ES. The reporting module within the Lutron Q-AdminT software can also be used to view historical trends of these objects. 5 Technical Support 800.523.9466

BACnet Alarming Lutron does not support the BACnet alarm convention described in clause 13, Alarm and Event Services of the standard. However, the Lutron system does share asset and maintenance data appropriate for alarms (lamp failure, ballast failures, low battery failures on wireless devices, etc.) through Binary, Analog, and Multi-State objects. To create alarms in the Tracer system, create BACnet objects in Tracer SC and then reference them to Lutron objects. These Tracer SC BACnet objects will be used to alarm the Lutron lighting objects to display in the Alarm Status or Graphics application at Trane Tracer System. The alerts module within the Lutron Q-AdminT software can also be used to configure and view alerts. Common Integration Examples A BMS system can trigger load-shed events in the Quantum system. Occupancy sensor status can be shared with the HVAC system to set back temperatures when areas become unoccupied. Quantum energy usage information can be shared with the BMS to eliminate the need to add costly energy meters. Important Integration Notes: BACnet /IP is the primary means of integration for Quantum. To simplify the integration process, it is recommended that the integrator and Lutron field service representative or project manager assigned to the job coordinate on area/point naming conventions when designing job, not during installation. Coordinate with Lutron to disable Lutron schedule if BACnet schedules are used. Who-Is requests should be separated by a minimum of 10 seconds. More frequent requests may cause communication issues due to the number of points available in the Lutron system through a single IP address. Key contacts if you need assistance on a job: Lutron : Pre-Sale Support: systemsalesengineers@lutron.com Post-Sale Support: 1.800.523.9466; systemsupport@lutron.com Trane : Technical Support: Contact the local Trane Sales Office. Go to www.trane.com to find your local sales office. 6 www.lutron.com

Lutron, GreenGlance, Personna and Quantum are registered trademarks and Q-Admin is a trademark of Lutron Electronics Co., Inc. BACnet is a registered trademark of ASHRAE. Trane, Earthwise and Tracer are trademarks of Trane registered in the United States and other countries. LonTalk is a registered trademark of Echelon Corporation. Lutron Contact Numbers WORLD HEADQUARTERS USA Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 TEL: +1.610.282.3800 FAX: +1.610.282.1243 Toll-Free: 1.888.LUTRON1 Technical Support: 1.800.523.9466 intsales@lutron.com North & South America Technical Hotlines USA, Canada, Caribbean: 1.800.523.9466 Mexico: +1.888.235.2910 Central/South America: +1.610.282.6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd. 6 Sovereign Close London, E1W 3JF United Kingdom TEL: +44.(0)20.7702.0657 FAX: +44.(0)20.7480.6899 FREEPHONE (UK): 0800.282.107 Technical Support: +44.(0)20.7680.4481 lutronlondon@lutron.com 7 ASIAN HEADQUARTERS Singapore Lutron GL Ltd. 15 Hoe Chiang Road #07-03, Tower 15 Singapore 089316 TEL: +65.6220.4666 FAX: +65.6220.4333 Technical Support: 800.120.4491 lutronsea@lutron.com Asia Technical Hotlines Northern China: 10.800.712.1536 Southern China: 10.800.120.1536 Hong Kong: 800.901.849 Indonesia: 001.803.011.3994 Japan: +81.3.5575.8411 Macau: 0800.401 Taiwan: 00.801.137.737 Thailand: 001.800.120.665853 Other Countries: +65.6220.4666 Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299 U.S.A. P/N 048-523 Rev. A 08/2014