Elements of required physical infrastructures: space, schielding, and patient flow..



Similar documents
GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

Staff Doses & Practical Radiation Protection in DEXA

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

The Design of Diagnostic Medical Facilities where Ionising Radiation is used

EPA Protocols: Compliance testing of dental X-ray apparatus used for plain radiography

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

X-ray Imaging Systems

X-ray Radiation Safety Course. James Kane & Rob Deters Office of Radiological Control

Required RS Training Info

Personal Dosimetry in Dental Radiology

Radiation Safety Characteristics of the NOMAD Portable X-ray System

Radiation Safety Issues for Radiologic Technologists

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Checklist for submission of application form for Registration

MALAYSIAN STANDARD CODE OF PRACTICE FOR RADIATION PROTECTION - MEDICAL X-RAY DIAGNOSIS (FIRST REVISION) Copyright 2007

QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions

APPLYING RADIATION SAFETY STANDARDS IN DIAGNOSTIC RADIOLOGY AND INTERVENTIONAL PROCEDURES USING X RAYS

Art Basel Miami Beach Dec Booth Design Regulations

RADIATION PROTECTION PROGRAM (RPP) GUIDANCE

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Mark Cramer Inspection Services, Inc.

Image Quality and Radiation Dose for Intraoral Radiography: Hand-Held Held (Nomad), Battery Powered

PART B REGISTRATION [LICENSURE] OF RADIATION MACHINE FACILITIES, [SERVICES] */ AND ASSOCIATED HEALTHCARE PROFESSIONALS

X-RAY REGULATORY GUIDE

RADIATION SAFETY STANDARD

Dimensioning and Estimating Brick Masonry

The effects of radiation on the body can be divided into Stochastic (random) effects and deterministic or Non-stochastic effects.

IAEA-TECDOC-1447 Optimization of the radiological protection of patients: Image quality and dose in mammography (coordinated research in Europe)

Energy Company Obligation (ECO): Technical Monitoring Questions

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

Shielding Solutions Who Is Nelco? NELCO Locations. Five Market Segments. Shielding Products Diagnostic. Professional Affiliations

X-ray Imaging Systems

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

SAFETY CODE FOR MEDICAL DIAGNOSTIC X-RAY EQUIPMENT AND INSTALLATIONS

General requirements. 1. Administrative Controls.

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) ACCREDITATION STANDARDS FOR SCHOOLS OF DENTAL RADIOLOGIC TECHNOLOGY

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Quality Control and Maintenance Programs

Dental Radiography collimator Ionising radiation image radiolucent area radiopaque area controlled zone scatter radiation intraoral

March 14, Installation of Bay, Bow and Garden Windows

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

STATE OF NEBRASKA STATUTES RELATING TO MEDICAL RADIOGRAPHY PRACTICE ACT

INTENSIFYING SCREENS, CASSETTES AND SCREEN FILMS N. Serman & S. Singer

Quality control tests of diagnostic radiology equipment in Hungary, and its radiation protection aspects

DIY GUIDE 10 EASY STEPS FOR TREATMENT OF RISING DAMP

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Installation Instructions

X-Mind. Instinct for perfection

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Radiation safety in dental radiography

Integrated Management & Educational Consultancy

Canvas Office Landscape Wall Strip Installation and Disassembly for Recycling Instructions

EMR Shielding of single level home from 3G mobile phone tower

Compliance Guidance for QUALITY ASSURANCE MANUAL (2 nd Edition)

CHAPTER 6 CONSTRUCTION TYPES

Module 3.7. Thermal bridging

Introduction. Chapter 15 Radiation Protection. Regulatory bodies. Dose Equivalent. Regulatory bodies. Main Principles of Radiation Protection

Radiologic Health Department Certification. Presented by Natalie Beechler Health Physicist Brea X-Ray Inspection, Compliance, and Enforcement Unit

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Analysis of Causes for Reject X-Ray Films as a Quality Assurance Element in Diagnostic Radiology in Jos University Teaching Hospital(JUTH)

Renovation instructions

Recommendations for a technical quality control program for diagnostic X-ray equipment

Safety and Radiation Protection Office Working with X-Ray Equipment

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Manual lifting and handling

Self-Home Inspection Checklist

Patient Exposure Doses During Diagnostic Radiography

State of Connecticut Department of Public Health RADON PROGRAM

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

Best Barns USA Assembly Book

Integrated Solar Radiant Systems

Regulatory Guide. Radiation Safety in Industrial Radiography (FANR-RG-019) Version 0

RADIATION SHIELDING DESIGN 2010

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

HSE information sheet Industrial radiography - managing radiation risks Ionising Radiation Protection Series No. 1(rev 1)

Window Installation Instructions

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Electrical Classification

Fire Barriers & Fire Stopping

X-ray (Radiography) - Chest

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

I.S :2013 Fire Detection & Alarm Systems

At the completion of this guide you should be comfortable with the following:

Mould Mould A Basic Guide

QUALITY ASSURANCE IN DENTAL RADIOGRAPHY. Part of the Ionising Radiation Regulations Section 4 (3) IR(ME)R 2000

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Radiation Safety Committee College of William and Mary

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

portable x-ray survey report

Digital Dental X-ray. Midmark Animal Health Products

Transcription:

Elements of required physical infrastructures: space, schielding, and patient flow.. IAEA Following the IAEA guidelines, adapded by Anna Benini for workshop on Health Technology IUPESM Task Group, Porto Allegre, Brasil 17 April 2011

*Topics ü Equipment design and acceptable safety standards ü Availability of space and use of dose constraints in X Ray room design ü Barriers and protective devices ü Patients waiting space and flow ü Qualification and training of personnel ü Choice of equipment ü Planning regular radiation protection and QA/QC IAEA 12: Shielding and X Ray room design 2

Purpose of Shielding To protect: the X Ray department staff the patients (when not being examined) visitors and the public persons working adjacent to or near the X Ray facility IAEA 12: Shielding and X Ray room design 3

Radiation Shielding - Design Concepts Data required include consideration of: Type of X Ray equipment Usage (workload) Positioning Whether multiple tubes/receptors are being used Primary beam access (vs. scatter only) Operator location Surrounding areas IAEA 12: Shielding and X Ray room design 4

Shielding Design (I) Equipment What equipment is to be used? General radiography Fluoroscopy (with or without radiography) Dental (oral or OPG) Mammography CT IAEA 12: Shielding and X Ray room design 5

* and which kind of equipment??? Do we plan for for all health stations to have also X Ray equipment?? Only simple basic investigations will be performed?! Which kind of investigations chest.and?? Qualification of staff??? Evaluation of required investment and infrastructures! IAEA

* Equipment evaluation Once decided to have an X Ray equipment. Definition-evaluation of kinds of investigation Staff training..telemedicine might be a good alternative It is very important to choose the right kind of equipment. purchase evaluation, considering the working condition and environment!!! Strong and simple equipment!!! IAEA

Shielding Design (II) The type of equipment is very important for the following reasons: where the X Ray beam will be directed the number and type of procedures performed the location of the radiographer (operator) the energy (kvp) of the X Rays IAEA 12: Shielding and X Ray room design 8

Shielding Design (III) Usage Different X Ray equipment have very different usage. For example, a dental unit uses low mas and low (~70) kvp, and takes relatively few X Rays each week A CT scanner uses high (~130) kvp, high mas, and takes very many scans each week. IAEA 12: Shielding and X Ray room design 9

Shielding Design (IV) The total mas used each week is an indication of the total X Ray dose administered The kvp used is also related to dose, but also indicates the penetrating ability of the X Rays High kvp and mas means that more shielding is required. IAEA 12: Shielding and X Ray room design 10

Shielding Design (V) Positioning The location and orientation of the X Ray unit is very important: distances are measured from the equipment (inverse square law will affect dose) the directions the direct (primary) X Ray beam will be used depend on the position and orientation IAEA 12: Shielding and X Ray room design 11

Radiation Shielding - Typical Room Layout A to G are points used to calculate shielding IAEA 12: Shielding and X Ray room design 12

*Evaluation of setting In case of heavy workload???? Adequate patients waiting space (large enough), with optimization of flow * Possibility to have two change cabines in order to reduce waiting time In this case both cabines should be shielded in order to avoid unecessary patient exposures and opened, inside by operator IAEA

*Patients flow The patients waiting room should be choosen in order also to optimize the schielding For example avoid to put chairs in the hot spots Optimize the patients changing time accordingly to the technical time of the investigations IAEA

Shielding Design (VI) Number of X Ray tubes Some X Ray equipment may be fitted with more than one tube Sometimes two tubes may be used simultaneously, and in different directions This naturally complicates shielding calculation IAEA 12: Shielding and X Ray room design 15

Shielding Design (VII) Surrounding areas The X Ray room must not be designed without knowing the location and use of all rooms which adjoin the X Ray room Obviously a toilet will need less shielding than an office First, obtain a plan of the X Ray room and surroundings (including level above and below) IAEA 12: Shielding and X Ray room design 16

Radiation Shielding - Design Detail Must consider: appropriate calculation points, covering all critical locations design parameters such as workload, occupancy, use factor, leakage, target dose (see later) these must be either assumed or taken from actual data use a reasonable worst case more than typical case, since undershielding is worse than overshielding IAEA 12: Shielding and X Ray room design 17

Radiation Shielding Parameters (I) P - design dose per week usually based on 5 msv per year for occupationally exposed persons (25% of dose limit), and 1 msv for public occupational dose must only be used in controlled areas i.e. only for radiographers and radiologists IAEA 12: Shielding and X Ray room design 18

Radiation Shielding Parameters (II) Film storage areas (darkrooms) need special consideration Long periods of exposure will affect film, but much shorter periods (i.e. lower doses) will fog film in cassettes A simple rule is to allow 0.1 mgy for the period the film is in storage - if this is 1 month, the design dose is 0.025 mgy/week IAEA 12: Shielding and X Ray room design 19

Radiation Shielding Parameters (III) Remember we must shield against three sources of radiation In decreasing importance, these are: primary radiation (the X Ray beam) scattered radiation (from the patient) leakage radiation (from the X Ray tube) IAEA 12: Shielding and X Ray room design 20

Radiation Shielding Parameters (IV) U - use factor fraction of time the primary beam is in a particular direction i.e.: the chosen calculation point must allow for realistic use for all points, sum may exceed 1 IAEA 12: Shielding and X Ray room design 21

Radiation Shielding Parameters (V) For some X Ray equipment, the X Ray beam is always stopped by the image receptor, thus the use factor is 0 in other directions e.g.: CT, fluoroscopy, mammography This reduces shielding requirements IAEA 12: Shielding and X Ray room design 22

Radiation Shielding Parameters (VI) For radiography, there will be certain directions where the X Ray beam will be pointed: towards the floor across the patient, usually only in one direction toward the chest Bucky stand The type of tube suspension will be important, e.g.: ceiling mounted, floor mounted, C-arm etc. IAEA 12: Shielding and X Ray room design 23

Radiation Shielding Parameters (VII) T - Occupancy T = fraction of time a particular place is occupied by staff, patients or public Has to be conservative Ranges from 1 for all work areas to 0.06 for toilets and car parks IAEA 12: Shielding and X Ray room design 24

Occupancy (NCRP49) Area Work areas (offices, staff rooms) Occupancy 1 Corridors 0.25 Toilets, waiting rooms,car parks 0.06 A critical review proposes new values for Uncontrolled and Controlled areas: See R.L. Dixon, D.J. Simpkin IAEA 12: Shielding and X Ray room design 25

Radiation Shielding Parameters (VIII) W - Workload A measure of the radiation output in one week Measured in ma-minutes Varies greatly with assumed maximum kvp of X Ray unit Usually a gross overestimation Actual dose/mas can be estimated IAEA 12: Shielding and X Ray room design 26

Workload (I) For example: a general radiography room The kvp used will be in the range 60-120 kvp The exposure for each film will be between 5 mas and 100 mas There may be 50 patients per day, and the room may be used 7 days a week Each patient may have between 1 and 5 films SO HOW DO WE ESTIMATE W? IAEA 12: Shielding and X Ray room design 27

Workload (II) Assume an average of 50 mas per film, 3 films per patient Thus W = 50 mas x 3 films x 50 patients x 7 days = 52,500 mas per week = 875 ma-min per week We could also assume that all this work is performed at 100 kvp IAEA 12: Shielding and X Ray room design 28

Examples of Workloads in Current Use (NCRP 49) Weekly Workload (W) ma-min at: 100 kvp 125 kvp 150 kvp General Radiography 1,000 400 200 Fluoroscopy (including spot films) 750 300 150 Chiropractic 1,200 500 250 Mammography Dental 700 at 30 kvp (1,500 for breast screening) 6 at 70 kvp (conventional intra-oral films) More realistic values include CT: see ref. Simpkin (1997) IAEA 12: Shielding and X Ray room design 29

Workload - CT CT workloads are best calculated from local knowledge Remember that new spiral CT units, or multislice CT, could have higher workloads A typical CT workload is about 28,000 mamin per week IAEA 12: Shielding and X Ray room design 30

Tube Leakage All X Ray tubes have some radiation leakage - there is only 2-3 mm lead in the housing Leakage is limited in most countries to 1 mgy.hr-1 @ 1 meter, so this can be used as the actual leakage value for shielding calculations Leakage also depends on the maximum rated tube current, which is about 3-5 ma @ 150 kvp for most radiographic X Ray tubes IAEA 12: Shielding and X Ray room design 31

Radiation Shielding Parameters IAEA 12: Shielding and X Ray room design 32

Shielding - Construction I Materials available: lead (sheet, composite, vinyl) brick gypsum or baryte plasterboard concrete block lead glass/acrylic IAEA 12: Shielding and X Ray room design 33

Shielding - Construction Problems Some problems with shielding materials: Brick walls - mortar joints Use of lead sheets nailed to timber frame Lead inadequately bonded to backing Joins between sheets with no overlap Use of hollow core brick or block Use of plate glass where lead glass specified IAEA 12: Shielding and X Ray room design 34

Problems in shielding - Brick Walls & Mortar Joints Bricks should be solid and not hollow Bricks have very variable X Ray attenuation Mortar is less attenuating than brick Mortar is often not applied across the full thickness of the brick IAEA 12: Shielding and X Ray room design 35

Problems in shielding - Lead inadequately bonded to backing Lead must be fully glued (bonded) to a backing such as wood or wallboard If the lead is not properly bonded, it will possibly peel off after a few years Not all glues are suitable for lead (oxidization of the lead surface) IAEA 12: Shielding and X Ray room design 36

Problems in shielding - Joins between sheets with no overlap There must be 10-15 mm overlap between adjoining sheets of lead Without an overlap, there may be relatively large gaps for the radiation to pass through Corners are a particular problem IAEA 12: Shielding and X Ray room design 37

Problems in shielding - Use of plate glass Plate glass (without lead of specified quantity as used in windows, but thicker) is not approved as a shielding material The radiation attenuation of plate glass is variable and not predictable Lead glass or lead Perspex must be used for windows IAEA 12: Shielding and X Ray room design 38

Radiation Shielding - Construction II Continuity and integrity of shielding very important Problem areas: joins penetrations in walls and floor window frames doors and frames IAEA 12: Shielding and X Ray room design 39

Penetrations Penetrations means any hole cut into the lead for cables, electrical connectors, pipes etc. Unless the penetration is small (~2-3 mm), there must be additional lead over the hole, usually on the other side of the wall Nails and screws used to fix bonded lead sheet to a wall do not require covering IAEA 12: Shielding and X Ray room design 40

Shielding of Doors and Frames IAEA 12: Shielding and X Ray room design 41

Shielding - Verification I Verification should be mandatory Two choices - visual or measurement Visual check must be performed before shielding covered - the actual lead thickness can be measured easily Radiation measurement necessary for window and door frames etc. Measurement for walls very slow IAEA 12: Shielding and X Ray room design 42

Shielding Testing IAEA 12: Shielding and X Ray room design 43

Records It is very important to keep records of shielding calculations, as well as details of inspections and corrective action taken to fix faults in the shielding In 5 years time, it might not be possible to find anyone who remembers what was done! IAEA 12: Shielding and X Ray room design 44

*Comments 1 Shielding might look complex but in reality is simple as it is usually done using tables and computer The evaluation should be done by a RPO or QE, (consultant?) as part of the installing cost It is a work done at the beginning when installing the equipment and than it has to be cheked regularly (simple) The same RPO or QE taking care of personnel dosimetry, etc. might do also this once a year IAEA

* Comments 2 Main problems remain the identification of requirements and needs at the beginning and than the evaluation of results and quality of diagnostic Integration of radiation protection an quality assurance/quality control is essential for good results IAEA