Electron-Muon Ranger (EMR)



Similar documents
Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR)

Progress status of EMR Geneva

EMR project Overview

Progress status of EMR Geneva

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

Electron-Muon Ranger (EMR)

Electron-Muon Ranger (EMR)

PoS(PhotoDet 2012)068

MICE Major Milestone Status Revision date: 4/4/12 (MICO 181)

Security & Surveillance Cabling Systems

Aerogel and Assembly. Aerogel shipped to US (IIT) in June; shipment to RAL after inspection. Counter 1: n=1.08; counter 2: n=1.12.

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

Excellence, that connects. Sachsenkabel data center

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

System Wiring Design Guide

Trigger & DAQ. Ryan Rivera 8/03/2015. Mu2e

DOCUMENTATION FOR ELECTICAL SAFETY REVIEW OF MINOS DETECTOR SYSTEM AT THE MINOS NEAR DETECTOR HALL

Market Central

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Electron Muon Ranger (EMR) Software Development

RICH. INFN Perugia INFN Firenze CERN. M.Lenti

Setup guide. point to point wall plate extenders

Raritan LCD KVM Console (T1700/T1900)

Mechanical Design, Fabrication, and Installation

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Basic Configuration Package

BUDGETARY QUOTATION AND TECHNICAL INFORMATION

v1 System Requirements 7/11/07

Installation and Operation Manual Blackmagic Converters. Mac OS X Windows

MDU SC Connector Termination Procedure

ISHIDA BC Scale to Scale Communications

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Nevco, Inc. Installation Manual

=============================== WARNING

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

InFocus Projector Setup Guide for Digital Cable TV How to connect digital cable TV to an InFocus projector

Manual. Sealer Monitor Software. Version

CATALOGUE Smart Home Engineering

RFS-805. Digital Modulator AV to COFDM. User Manual

Installation Guide. Wyse Z Class 2 and 4-GB RAM Upgrade Option Kit. Products: Z90DW, Z90SW, Z90D7, Z90S7. Issue: PN: L Rev.

MT-RJ Connectors Termination Procedure

Data Center Cabling Design Trends

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Cabling & Connectivity

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

NIM High Voltage Power Supplies

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Buffalo, New York Garland, Texas

Optimux-34, Optimux-25

LwLVision-USB 2.0. Installation Guide

Migrating Control System Servers to Virtual Machines

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

White Paper. Power over Ethernet Plus Update and Cabling Considerations

RC001-4/RC002-4 (REV.B) 4-slot rack mounted chassis User manual

NetCom Quick Setup Guide

GP-B Telescope Measurement of Telescope Field of View P0454 Rev -

Interfacing Credit Card-sized PCs to Board Level Electronics

Deliver instant switching in four different modes for data center, control room, pooling, and similar applications.

Bluetooth HC-06 with serial port module Easy guide

TI 313 (1.0 EN) d&b Remote network - Integration

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

Fibre Channel Fiber-to-Fiber Media Converters

MH - Gesellschaft für Hardware/Software mbh

Loc Description Vendor Model Designator

Development. Igor Sheviakov Manfred Zimmer Peter Göttlicher Qingqing Xia. AGIPD Meeting April, 2014

The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links. Filippo Costa on behalf of the ALICE DAQ group

Perle 10/100/1000 Ethernet Media Converter Module

domain is known as the high side, and the less secure domain is the low side. Depending on the application, the

COFDM Transmission systems

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Module Connectors and Cable Specifications

AGIPD Interface Electronic Prototyping

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

ADVANCED CUSTOMER SUPPORT ORACLE STANDARD SYSTEM INSTALLATION (OSSI) BASIC SERVICE EXHIBIT

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

THE TESLA TEST FACILITY AS A PROTOTYPE FOR THE GLOBAL ACCELERATOR NETWORK

Network Attached Storage Common Configuration for Entry-Level

Contract Number NNG07DA20B NASA SEWP IV

ISTITUTO NAZIONALE DI FISICA NUCLEARE

Scale Computing Storage Cluster Installation Guide. Scale Computing 2121 S. El Camino Real San Mateo, CA

Waveform Monitor Audio & Loudness Logging

The data acquisition system of the XMASS experiment

UNI EN ISO 9001 CERT. N CAEN November 2006 EURITRACK Workshop

Category 6 UTP - Cabling System

ABB Robotics, June IRB 1200 Overview. ABB Group August 21, 2014 Slide 1

Features of Corona 2.4GHz transmitting module and receiver. The new lightweight, advanced technology unit has the following features:

FB-500A User s Manual

Out-of-box comparison between Dell, HP, and IBM blade servers

Product Information D23m Digital I/O System

HS10 HYBRIDSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1

Raritan AMS Series Intelligent Electronic Asset Management

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

Designing Fiber Optic Systems David Strachan

ULiSSe compact ip. ULiSSe compact ip + ir Led

78 Battery Converter HDMI to SDI

Transcription:

Electron-Muon Ranger (EMR) Status of EMR Project R.Asfandiyarov 1, P.Béné 1, R.Bloch 1, A.Blondel 1, D.Bolognini 3 F.Cadoux 1, S.Débieux 1, J-S.Graulich 1, C.Husi 1, Y.Karadzhov 1, D.Lietti 3, F.Masciocchi 1, L.Nicola 1, M.Prest 3, K.Rothenfusser 1, E.Vallazza 2, V.Verguilov 1 1 DPNC, Université de Genève, Switzerland 2 INFN, Sezione di Trieste, Italy 3 Università degli Studi dell Insubria and INFN, Sezione di Milano Bicocca, Italy MICE Video Conference, March 24, 2011 R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 1 / 14

EMR Design: Reminder Horizontal View Characteristics 24 modules (X-Y planes) 48 planes 59 bars per plane 2832 bars 3m WLS fibers per bar 8.5 km WLS fibers single and 64-channel PMTs per plane 3072 + 48 channels R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 2 / 14

New Modules Production and Assembly New Modules Patch-Pannle and Inner Cabling 2 new modules are completed 2 other modules are on the test bench a separate test of WLS fibers and PMT connectors (polishing) has been designed R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 3 / 14

New Modules Patch-Pannle and Inner Cabling Will be set up next week. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 4 / 14

New Modules Patch-Pannle and Inner Cabling Machine Polishing. Broken fibers are clearly visible Fibers with reduced light transmition also also present R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 5 / 14

New Modules Patch-Pannle and Inner Cabling Hand Polishing Machine polishing significantly improves the quality of the surface (compare with pictures on the previos slide) R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 6 / 14

Patch-Pannle and Inner Cabling New Modules Patch-Pannle and Inner Cabling All the cables have been modeled in order to estimate their length inside the EMR box When EMR is in vertical position patch-panels will be on the top. Extra cable length is reserved for easy access to the patch-panels. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 7 / 14

Lower Chassis Production and Assembly Lower Chassis Finite Element Analysis (FEA) EMR Rack and Outer Cabling The disign of the lower chassis has been finilized R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 8 / 14

Finite Element Analysis (FEA) Lower Chassis Finite Element Analysis (FEA) EMR Rack and Outer Cabling According to FEA the safety margin is quite sufficient. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 9 / 14

EMR Rack and Outer Cabling Lower Chassis Finite Element Analysis (FEA) EMR Rack and Outer Cabling from VME to Control Room: 10 BNC + 1 optical fiber from EMR to the VME crate June 2011: 12 x SHV 4 x SMA 8 x BNC 3 x LV 4 x 17-twisted-pair December 2011: 96 x SHV 32 x SMA 50 x BNC 5 LV 4 x 17-twisted-pair R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 10 / 14

Firmware and Data Format Firmware and Data Format Power Supply for FEB+DBB Communication scheme for the readout of the DBB has been defined. Firmware for DBB and VME readout boards will comply with the scheme. R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 11 / 14

Power Supply for FEB+DBB Firmware and Data Format Power Supply for FEB+DBB CAEN SY8800 has been selected 3 modules 110A/5V should cover all power needs The 3 modules will fit into one frame (shown below) It can be remotely controled via Ethernet, USB, CANBUS and RS232 R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 12 / 14

Schedule Production and Assembly Firmware and Data Format Power Supply for FEB+DBB The current plan for first EMR tests at RAL: May 30, 2011 Packing and shipment from UNIGE June 6, 2011 Arrival to RAL June 13, 2011 Installation in the hall June 20, 2011 Tests with Cosmics at RAL June 27, 2011 Tests with beam at RAL R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 13 / 14

Cosmic Test Setup Production and Assembly Firmware and Data Format Power Supply for FEB+DBB Results from Cosmic Test Setup are coming soon... R.Asfandiyarov (U.Genève), Status of EMR Project MICE Video Conference, March 24, 2011 14 / 14