Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.



Similar documents
Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

Labral Repair. Surgical Protocol by Ronald Glousman, M.D. and Nicholas Sgaglione, M.D.

with Medial Patellofemoral Ligament (MPFL) Reconstruction Surgical Protocol by Ronald Navarro, M.D.

Finally INSTRUMENTS. Tray 1 Hand Instruments and RC Retractor. Tray 2 Portal Placement/ Miscellaneous Tray

(English) NEXUS SPINE SPACER SYSTEM

Y O U R S U R G E O N S. choice of. implants F O R Y O U R S U R G E R Y

Achilles Tendon Repair, Operative Technique

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

How To Fix A Radial Head Plate

Arthroscopic Shoulder Instability Repair Using the SUTUREFIX ULTRA Suture Anchor and SUTUREFIX ULTRA Instrumentation System

Lentur Cable System. Surgical Technique

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Bankart Repair using the Smith & Nephew BIORAPTOR 2.9 Suture Anchor

The Material Difference. Options for Rotator Cuff Repair, Labral Repair and Suture Management

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Technique Guide. VersiTomic. Michael A. Rauh, MD. Anterior Cruciate Ligament Reconstruction

Posterior Referencing. Surgical Technique

Knotilus TM. Anchor Instability Repair. Technique Guide

Stabilization of Acute Acromioclavicular Joint Dislocations using Dog Bone Button Technology Surgical Technique

Malleolar fractures Anna Ekman, Lena Brauer

Integra. Subtalar MBA Implant

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Sports Injuries of the Foot and Ankle. Dr. Travis Kieckbusch August 7, 2014

Shoulder Restoration System


Plasmax Plasma Concentration System BIOLOGICS

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

V-TEK IVP System 2.7 System 4.0

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

.org. Ankle Fractures (Broken Ankle) Anatomy

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Integra. Subtalar MBA and bioblock Implant SURGICAL TECHNIQUE

Syndesmosis Injuries

Plasmax Plasma Concentration System for Laparoscopic Roux-en-Y Gastric Bypass

Mini TightRope CMC Surgical Technique

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

ACL Reconstruction with Bone-Tendon-Bone Transplants Using the ENDOBUTTON CL BTB Fixation System

Titanium Wire with Barb and Needle. For canthal tendon procedures.

QUESTION I HAVE BEEN ASKED TO REHAB GRADE II AND III MCL INJURIES DIFFERENTLY BY DIFFERENT SURGEONS IN THE FIRST 6WEEKS FOLLOWING INJURY.

Zimmer Small Fragment Universal Locking System. Surgical Technique

SHOULDER INSTABILITY. E. Edward Khalfayan, MD

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

Adult Forearm Fractures

PERIPROSTHETIC IMPLANTS

Information for the Patient About Surgical

Lateral Ankle Instability Repair using TWINFIX Ti 3.5 mm Suture Anchors

Rehabilitation Guidelines for Patellar Tendon and Quadriceps Tendon Repair

Hand and Upper Extremity Injuries in Outdoor Activities. John A. Schneider, M.D.

1 of 6 1/22/ :06 AM

Zimmer Periarticular Proximal Tibial Locking Plate

The information contained in this document is intended for healthcare professionals only.

Cable System. For Orthopaedic Trauma Surgery.

The Total Ankle Replacement

METAL HEMI. Great Toe Implant SURGICAL TECHNIQUE

Rehabilitation Guidelines for Lateral Ankle Reconstruction

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

TransFx External Fixation System Large and Intermediate Surgical Technique

HUNTER TENDON IMPLANTS

Foot and Ankle Injuries in the Adolescent Athlete

Arthroscopic Shoulder Procedures. David C. Neuschwander MD. Shoulder Instability. Allegheny Health Network Orthopedic Associates of Pittsburgh

GALLAND/KIRBY UCL RECONSTRUCTION (TOMMY JOHN) POST-SURGICAL REHABILITATION PROTOCOL

TOWN CENTER ORTHOPAEDIC ASSOCIATES P.C. Labral Tears

Achilles Tendon Repair Surgery Post-operative Instructions Phase One: The First Week After Surgery

Open Rotator Cuff Repair Rehabilitation Program Methodist Sports Medicine Center, Indianapolis, IN Department of Physical Therapy

Shoulder Arthroscopy

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

KNEE LIGAMENT REPAIR AND RECONSTRUCTION INFORMED CONSENT INFORMATION

Affected Product: Polyethylene Implants from Gender Solutions Natural-Knee Flex, Natural-Knee, Natural-Knee II, MOST Options, and Apollo Systems

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

frequently asked questions Knee and Hip Joint Replacement Technology

Your Practice Online

Spinal Arthrodesis Group Exercises

Posttraumatic medial ankle instability

Anteromedial ACL Reconstruction Surgical Technique for Soft Tissue Grafts

it s time for rubber to meet the road

Ankle Injury/Sprains in Youth Soccer Players Elite Soccer Community Organization (ESCO) November 14, 2013

BONE PRESERVATION STEM

Anterior Capsular Repair Rehabilitation Program Methodist Sports Medicine Center, Indianapolis, IN Department of Physical Therapy

Pre - Operative Rehabilitation Program for Anterior Cruciate Ligament Reconstruction

Double Bone Plug Meniscus Reconstruction Surgical Technique

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Knee Microfracture Surgery Patient Information Leaflet

Arthroscopy of the Hand and Wrist

The rapid evolution of arthroscopic shoulder surgery

Eric M. Kutz, D.O. Arlington Orthopedics Harrisburg, PA

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires

External Fixation Systems IMPORTANT MEDICAL INFORMATION

Non Operative Management of Common Fractures

Semmelweis University Department of Traumatology Dr. Gál Tamás

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Case Report Reconstructive Osteotomy for Ankle Malunion Improves Patient Satisfaction and Function

Why an Exactech Hip is Right for You

ACL Reconstruction: Patellar Tendon Graft/Hamstring Tendon Graft

ACCORD Cable System. Surgical technique completed in conjunction with: Robert Barrack, MD St. Louis, Missouri. Paul Di Cesare, MD New York, New York

How To Use A Phoenix Retrograde Femoral Nail

INFUSE Bone Graft. Patient Information Brochure

.org. Arthritis of the Hand. Description

Transcription:

Featuring Ankle Syndesmosis Surgical Protocol by Timothy Charlton, M.D.

ZipLoop Technology is a unique weave in which a single strand of braided polyethylene is woven through itself twice in opposite directions. This construct allows Biomet Sports Medicine to produce innovative products that can vary in length and compression/tension addressing the individual needs of each patient. Products utilizing ZipLoop Technology are resistant to slippage without tying knots. 1 Procedure-specific animations, surgical protocols and surgery videos are available at www.ziploop.net. Medial Fixation Smaller version of the ToggleLoc Fixation Device for medial side fixation Material Available with either titanium or stainless steel buttons to correspond with the surgeon s preferred plating system www.ziploop.net 1. Data on file at Biomet Sports Medicine. Bench test results are not necessarily indicative of clinical performance. This brochure is presented to demonstrate the surgical technique and postoperative protocol utilized by Timothy Charlton, M.D. Biomet Sports Medicine, as the manufacturer of this device, does not practice medicine and does not recommend this or any other surgical technique for use on a specific patient. The surgeon who performs any procedure is responsible for determining and utilizing the appropriate techniques for such procedure for each individual patient. Biomet Sports Medicine is not responsible for selection of the appropriate surgical technique to be utilized for an individual patient.

Lateral Fixation Round top hat button for lateral fixation Can be used directly on the lateral cortex of the fibula or in conjunction with a plating system as deemed appropriate by the surgeon MaxBraid Suture Medial and lateral fixation devices connected with MaxBraid Suture Features Low profile, knotless suture fixation system featuring ZipLoop Technology Fixation alternative to rigid stainless steel screws for repairing ankle syndesmosis joint disruptions Available with either titanium or stainless steel buttons to correspond with the surgeon s preferred plating system Allows for micromotion during healing which more closely mimics the patient s true joint mechanics

Surgical Technique Figure 2 Figure 1 Figure 3 Indications The ZipTight Fixation System for Ankle Syndesmosis is indicated to repair ankle syndesmosis disruptions and as an adjunct in connection with trauma hardware for Weber B and C ankle fractures. Note: This surgical technique shows the ZipTight Fixation Device used in conjunction with trauma hardware. However, the device can also be used without trauma hardware in length stable fractures as determined appropriate by the surgeon. Reduce Fracture Reduce fracture to obtain correct length, rotation, and alignment. Reduce the syndesmosis joint as required to achieve anatomical correction, utilizing bone clamp(s). As determined appropriate by the surgeon, place the surgeon preferred trauma hardware plate and screws, in balanced fixation, on to fibula leaving an additional one or two screw holes empty, where ZipTight Fixation Device may be placed to repair the ankle syndesmosis disruption. Drill Through Fibula and Tibia Using either a solid or cannulated 3.2mm drill, create a drill pathway at or slightly above the incisura of the tibia at the distal tib-fib joint. Penetrate both tibial cortices with the 3.2mm drill (Figure 1). Pass the ZipTight Fixation Device After the bone tunnels have been prepared, pass the ZipTight Fixation Device pull strands through the tunnels from lateral to medial using the guide pin (Figure 2). Carefully continue pulling the ZipTight Fixation Device pull strand (white MaxBraid suture) until the ToggleLoc button exits the bone tunnel on the medial side of the tibia. Keeping the device taught from both ends keeps the ToggleLoc button angled so that it will easily flip on the medial cortex. As the button exits out of the medial tibial cortex, directing the hand inferiorly may aid in flipping the ToggleLoc button. Under fluoroscopic imaging, once the button appears to be out of the medial tibial cortex, pull the device back in the lateral direction so that the ToggleLoc button will flip and rest closely against the medial cortex of the tibia (Figure 3).

Figure 5 Figure 4 Figure 6 Zip the Top Hat Button Into Place Pull on the blue/white zip strands (blue/white MaxBraid suture) while maintaining tension on the solid blue backtension strand (blue polyester suture). The solid blue backtension strand provides slight counterforce to help keep the ZipLoop sutures organized (Figure 4). Continuing to pull the blue/white zip strands will bring the round top hat button down against the plate (or lateral fibular cortex if no plate is used) to its final deployed position on the lateral side of the fibula (Figure 5). Final Tensioning After the round top hat button is seated, the solid blue back-tension strand can be released and the surgeon can provide final tensioning by pulling on each leg of the blue/white zip strand to equalize tension of the legs of the ZipLoop strand. A ZipLoop puller can be used to assist in final tensioning of the fixation device. The strands and guide pin can be removed on the medial side. The solid blue back-tension strand can be cut and removed and the zip strands can be carefully cut down near the round top hat button with scissors or the Super MaxCutter Suture Cutter. (Figure 6). Note: No knots need to be tied because the construct utilizes ZipLoop Technology.

Surgical Technique (continued) Figure 7 Postoperative Protocol Fixation is complete (Figure 7). The patient is placed in a post-operative splint, non-weightbearing until suture removal. Non-weight bearing is maintained for a minimum of four weeks or until sufficient callus ensures length stability of the fibula. A compliant patient can be allowed to do gentle range of motion non-weightbearing at four weeks. In the presence of sufficient fibula healing, protected weightbearing can be started on week six. Advancement to full weightbearing is progressed as clinically indicated. Removal The need for removal will be determined by the surgeon. If removal is desired, a small incision over the ToggleLoc button on the medial tibia is made to expose the button. Similarly, a small incision is made over the round top hat button on the lateral fibula. Using a blade or cautery, cut both legs of the ZipLoop suture at the round top hat button. The round top hat button can be removed. The ToggleLoc button and suture can then be removed from the medial side of the tibia.

Package Insert Biomet Sports Medicine 56 East Bell Drive P.O. Box 587 Warsaw, Indiana 46581 USA 01-50-1186 Date: 03/09 Biomet Sports Medicine ToggleLoc System ATTENTION OPERATING SURGEON DESCRIPTION The ToggleLoc System is a non-resorbable system intended to aid in arthroscopic and orthopedic reconstructive procedures requiring soft tissue fixation, due to injury or degenerative disease. MATERIALS Titanium Alloy Ultra-High Molecular Weight Polyethylene (UHMWPE) Polypropylene Nylon Polyester Stainless Steel INDICATIONS FOR USE The ToggleLoc System devices are intended for soft tissue to bone fixation for the following indications: Shoulder Bankart lesion repair SLAP lesion repairs Acromio-clavicular repair Capsular shift/capsulolabral reconstruction Deltoid repair Rotator cuff tear repair Biceps Tenodesis Foot and Ankle Medial/lateral repair and reconstruction Mid- and forefoot repair Hallux valgus reconstruction Metatarsal ligament/tendon repair or reconstruction Achilles tendon repair Ankle Syndesmosis fixation (Syndesmosis disruptions) and as an adjunct in connection with trauma hardware for Weber B and C ankle fractures (only for ToggleLoc with Tophat) Elbow Ulnar or radial collateral ligament reconstruction Lateral epicondylitis repair Biceps tendon reattachment Knee ACL/PCL repair / reconstruction ACL/PCL patellar bone-tendon-bone grafts Double-Tunnel ACL reconstruction Extracapsular repair: MCL, LCL, and posterior oblique ligament Illiotibial band tenodesis Patellar tendon repair VMO advancement Joint capsule closure Hand and Wrist Collateral ligament repair Scapholunate ligament reconstruction Tendon transfers in phalanx Volar plate reconstruction Hip Acetabular labral repair CONTRAINDICATIONS 1. Infection. 2. Patient conditions including blood supply limitations, and insufficient quantity or quality of bone or soft tissue. 3. Patients with mental or neurologic conditions who are unwilling or incapable of following postoperative care instructions. 4. Foreign body sensitivity. Where material sensitivity is suspected, testing is to be completed prior to implantation of the device. WARNINGS The ToggleLoc System devices provide the surgeon with a means to aid in the management of soft tissue to bone reattachment procedures. While these devices are generally successful in attaining these goals, they cannot be expected to replace normal healthy bone or withstand the stress placed upon the device by full or partial weight bearing or load bearing, particularly in the presence of nonunion, delayed union, or incomplete healing. Therefore, it is important that immobilization (use of external support, walking aids, braces, etc.) of the treatment site be maintained until healing has occurred. Surgical implants are subject to repeated stresses in use, which can result in fracture or damage to the implant. Factors such as the patient s weight, activity level, and adherence to weight bearing or load bearing instructions have an effect on the service life of the implant. The surgeon must be thoroughly knowledgeable not only in the medical and surgical aspects of the implant, but also must be aware of the mechanical and metallurgical aspects of the surgical implants. Patient selection factors to be considered include: 1) need for soft tissue to bone fixation, 2) ability and willingness of the patient to follow postoperative care instructions until healing is complete, and 3) a good nutritional state of the patient 1. Correct selection of the implant is extremely important. The potential for success in soft tissue to bone fixation is increased by the selection of the proper type of implant. While proper selection can help minimize risks, neither the device nor grafts, when used, are designed to withstand the unsupported stress of full weight bearing, load bearing or excessive activity. 2. The implants can loosen or be damaged and the graft can fail when subjected to increased loading associated with nonunion or delayed union. If healing is delayed, or does not occur, the implant or the procedure may fail. Loads produced by weight bearing and activity levels may dictate the longevity of the implant. 3. Inadequate fixation at the time of surgery can increase the risk of loosening and migration of the device or tissue supported by the device. Sufficient bone quantity and quality are important to adequate fixation and success of the procedure. Bone quality must be assessed at the time of surgery. Adequate fixation in diseased bone may be more difficult. Patients with poor quality bone, such as osteoporotic bone, are at greater risk of device loosening and procedure failure. 4. Implant materials are subject to corrosion. Implanting metals and alloys subjects them to constant changing environments of salts, acids, and alkalis that can cause corrosion. Putting dissimilar metals and alloys in contact with each other can accelerate the corrosion process that may enhance fracture of implants. Every effort should be made to use compatible metals and alloys when marrying them to a common goal, i.e., screws and plates. 5. Care is to be taken to ensure adequate soft tissue fixation at the time of surgery. Failure to achieve adequate fixation or improper positioning or placement of the device can contribute to a subsequent undesirable result. 6. The use of appropriate immobilization and postoperative management is indicated as part of the treatment until healing has occurred. 7. Correct handling of implants is extremely important. Do not modify implants. Do not notch or bend implants. Notches or scratches put in the implant during the course of surgery may contribute to breakage. 8. DO NOT USE if there is a loss of sterility of the device. 9. Discard and DO NOT USE opened or damaged devices, and use only devices that are package in unopened or undamaged containers. 10. Adequately instruct the patient. Postoperative care is important. The patient s ability and willingness to follow instructions is one of the most important aspects of successful fracture management. Patients effected with senility, mental illness, alcoholism, and drug abuse may be at a higher risk of device or procedure failure. These patients may ignore instructions and activity restrictions. The patient is to be instructed in the use of external supports, walking aids, and braces that are intended to immobilize the fracture site and limit weight bearing or load bearing. The patient is to be made fully aware and warned that the device does not replace normal healthy bone, and that the device can break, bend or be damaged as a result of stress, activity, load bearing, or weight bearing. The patient is to be made aware and warned of general surgical risks, possible adverse effects, and to follow the instructions of the treating physician. The patient is to be advised of the need for regular postoperative follow-up examinations as long as the device remains implanted. PRECAUTIONS Do not reuse implants. While an implant may appear undamaged, previous stress may have created imperfections that would reduce the service life of the implant. Do not treat with implants that have been, even momentarily, placed in a different patient. Instruments are available to aid in the accurate implantation of internal fixation devices. Intraoperative fracture or breaking of instruments has been reported. Surgical instruments are subject to wear with normal usage. Instruments, which have experienced extensive use or excessive force, are susceptible to fracture. Surgical instruments should only be used for their intended purpose. Biomet Sports Medicine recommends that all instruments be regularly inspected for wear and disfigurement. If device contains MaxBraid suture, refer to manufacturer package insert for further information. POSSIBLE ADVERSE EFFECTS 1. Nonunion or delayed union, which may lead to breakage of the implant. 2. Bending or fracture of the implant. 3. Loosening or migration of the implant. 4. Metal sensitivity or allergic reaction to a foreign body. 5. Pain, discomfort, or abnormal sensation due to the presence of the device. 6. Nerve damage due to surgical trauma. 7. Necrosis of bone or tissue. 8. Inadequate healing. 9. Intraoperative or postoperative bone fracture and/or postoperative pain. STERILITY The ToggleLoc System devices are supplied sterile and are sterilized by exposure to Ethylene Oxide Gas (ETO) if device contains MaxBraid PE suture. Do not resterilize. Do not use any component from an opened or damaged package. Do not use past expiration date. Caution: Federal law (USA) restricts this device to sale, distribution, or use by or on the order of a physician. Comments regarding the use of this device can be directed to Attn: Regulatory Affairs, Biomet, Inc., P.O. Box 587, Warsaw IN 46581 USA, Fax: 574-372-3968. All trademarks herein are the property of Biomet, Inc. or its subsidiaries unless otherwise indicated. Authorized Representative: Biomet U.K., Ltd. Waterton Industrial Estate Bridgend, South Wales CF31 3XA, U. K. Manufacturer Date of Manufacture Do Not Reuse Consult Accompanying Documents Sterilized using Ethylene Oxide Sterilized using Irradiation Sterile Sterilized using Aseptic Technique Sterilized using Steam or Dry Heat Expiry Date WEEE Device Catalogue Number Lot Number Flammable The information contained in this package insert was current on the date this brochure was printed. However, the package insert may have been revised after that date. To obtain a current package insert, please contact Biomet Sports Medicine at the contact information provided herein.

Ordering Information ZipTight Fixation Device for Ankle Syndesmosis with ZipLoop Technology 904759 909856 Titanium Stainless Steel ZipTight Fixation Device for Ankle Syndesmosis with ZipLoop Technology Disposable Kits 909853 909857 Titanium Stainless Steel Sterile Kit Includes: Implant, 0.062" (1.57mm) x 6" needle crimped onto passing suture, two 0.062" (1.57mm) x 9" K-wires, one 3.2mm x 7.5" cannulated drill bit, and one 3.2mm x 5" solid drill bit K-wire 951549.045 (1.1mm) x 9" Pkg. 2 (Non-Sterile) 945019.045 (1.1mm) x 9" Partially Threaded (Sterile) Cannulated Drill Bit 948086 3.7mm x 5" (Non-Sterile) 948084 3.2mm x 5" (Non-Sterile) Solid Drill Bit 904301 3.2mm x 5" (Non-Sterile) Guide Pin 909634 3 32" x 16" (Non-Sterile) 909540 3 32" (Sterile) ZipLoop Puller 904776 Super MaxCutter Suture Cutter 900342 All trademarks herein are the property of Biomet, Inc. or its subsidiaries unless otherwise indicated. This material is intended for the sole use and benefit of the Biomet sales force and physicians. It is not to be redistributed, duplicated or disclosed without the express written consent of Biomet. For product information, including indications, contraindications, warnings, precautions and potential adverse effects, see the package insert and Biomet s website. SPORTS MEDICINE P.O. Box 587, Warsaw, IN 46581-0587 800.348.9500 ext. 1501 2013 Sports Medicine www.biometsportsmedicine.com Form No. BMET0570.0 REV0611 www.biometsportsmedicine.com