Towards an artificial pancreas



Similar documents
WHY THE IMPLANTABLE INSULIN PUMP WORKS SO WELL

Medical Policy Insulin Pumps

Insulin is a hormone produced by the pancreas to control blood sugar. Diabetes can be caused by too little insulin, resistance to insulin, or both.

Causes, incidence, and risk factors

X-Plain Hypoglycemia Reference Summary

HOW TO CARE FOR A PATIENT WITH DIABETES

DIABETIC EDUCATION MODULE ONE GENERAL OVERVIEW OF TREATMENT AND SAFETY

CME Test for AMDA Clinical Practice Guideline. Diabetes Mellitus

Department Of Biochemistry. Subject: Diabetes Mellitus. Supervisor: Dr.Hazim Allawi & Dr.Omar Akram Prepared by : Shahad Ismael. 2 nd stage.

DIALYSIS COMPACT. The function, diseases and treatments for the human kidney.

Tuberculosis And Diabetes. Dr. hanan abuelrus Prof.of internal medicine Assiut University

Basal and Bolus Insulin 7/16/2014. Jackie Aday RN, BSN, CDE Jeni Neighbors RN, BSN, CDE. BASAL: Small amount of insulin infused every few minutes

Class time required: Two 40-minute class periods + homework. Part 1 may be done as pre-lab homework

The Family Library. Understanding Diabetes

Textbook: Chapter 12 pages , Chapter 13 pages

Insulin Pens & Improving Patient Adherence

Calculating and Graphing Glucose, Insulin, and GFR HASPI Medical Biology Activity 19c

Diabetes mellitus. Lecture Outline

PHARMACOTHERAPY HOW TO INJECT INSULIN. Living your life as normal as possible.

Overview of Diabetes Management. By Cindy Daversa, M.S.,R.D.,C.D.E. UCI Health

N E B R A S K A JAIL BULLETIN NUMBER 102 OCTOBER 1993

Nursing 113. Pharmacology Principles

X-Plain Diabetes - Introduction Reference Summary

Absorption of Drugs. Transport of a drug from the GI tract

written by Harvard Medical School Insulin Therapy Managing Your Diabetes

PowerPoint Lecture Outlines prepared by Dr. Lana Zinger, QCC CUNY. 12a. FOCUS ON Your Risk for Diabetes. Copyright 2011 Pearson Education, Inc.

CHAPTER 1 INTRODUCTION

DIABETES. Eyes, Heart, Nerves, Feet, and Kidneys.

PERIPHERAL STEM CELL TRANSPLANT INTRODUCTION

Insulin Infusion Pumps

7 Answers to end-of-chapter questions

Peritoneal Carcinosis

Introduction. We hope this guide will aide you and your staff in creating a safe and supportive environment for your students challenged by diabetes.

1333 Plaza Blvd, Suite E, Central Point, OR *

Type 2 diabetes Definition

A Fuzzy Controller for Blood Glucose-Insulin System

Nutrition. Type 2 Diabetes: A Growing Challenge in the Healthcare Setting NAME OF STUDENT

Procedure for the Management of. when unwell. To be completed at the start of each academic year and reviewed regularly.

Get Primed on Pumps: A beginners guide to Insulin Pump Therapy

Chapter 12. Temperature Regulation. Temperature Regulation. Heat Balance. An Overview of Heat Balance. Temperature Regulation. Temperature Regulation

ETIOLOGIC CLASSIFICATION. Type I diabetes Type II diabetes

Intravenous Fluid Selection

WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?

How To Write A Guideline For Global Application From The Clinical And Laboratory Standards Institute

Insulin Pump Management and Continuous Glucose Monitoring Systems (CGMS)

Lab 2. Spectrophotometric Measurement of Glucose

Disability Evaluation Under Social Security

Owner Manual. Diabetes in Dogs. Simplifying small animal diabetes

Chapter 26. Metabolic Rate, Body Heat, and Thermoregulation

DIABETES A chronic, debilitating and often deadly disease A global epidemic Diabetes in Africa

The Background for the Diabetes Detection Model

Endocrine System: Practice Questions #1

Blood Glucose Management

Abdulaziz Al-Subaie. Anfal Al-Shalwi

Cells, tissues and organs

Medical Coverage Policy Glucose Monitoring Systems sad

DIABETES MELLITUS. By Tracey Steenkamp Biokineticist at the Institute for Sport Research, University of Pretoria

Markham Stouffville Hospital

Diabetes Fundamentals

BIO 137: CHAPTER 1 OBJECTIVES

Other Noninfectious Diseases. Chapter 31 Lesson 3

DRUGS FOR GLUCOSE MANAGEMENT AND DIABETES

tips Insulin Pump Users 1 Early detection of insulin deprivation in continuous subcutaneous 2 Population Study of Pediatric Ketoacidosis in Sweden:

Department of Health Commencing insulin therapy

Effect of Coccinia indica on Blood Glucose Levels in Alloxan-induced Diabetic Mice. Kathryn Niedzielski Advisor: Dr. Linda Swift

Diabetes Hypoglycemia/Hyperglycemia Reaction

THE EFFECT OF SODIUM CHLORIDE ON THE GLUCOSE TOLERANCE OF THE DIABETIC RAT*

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

Suffering from varicose veins? Patient Information. ELVeS Radial Minimally invasive laser therapy of venous insufficiency

Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES

How to design an insulin pump

CLOSED LOOP MODEL FOR GLUCOSE INSULIN REGULATION SYSTEM USING LABVIEW

Imagine a world... Believe in better control. MiniMed Veo Paradigm System Questions and Answers About Insulin Pumping

Emergency Fluid Therapy in Companion Animals

Design of an Insulin Pump. Purpose of an Insulin Pump:

CLASS OBJECTIVES. Describe the history of insulin discovery List types of insulin Define indications and dosages Review case studies

Management of Diabetes Mellitus in Custody

Smoking and misuse of certain pain medicines can affect the risk of developing renal cell cancer.

Positron Emission Tomography - For Patients

Gentle and safe injections. Tips and tricks for injecting insulin.

Cardiovascular Disease Risk Factors Part XII Insulin Resistance By James L. Holly, MD Your Life Your Health The Examiner September 15, 2005

What Alcohol Does to the Body. Chapter 25 Lesson 2

Diabetes Brief. Pre diabetes occurs when glucose levels are elevated in the blood, but are not as high as someone who has diabetes.

Diabetes Expert Witness on: Diabetic Hypoglycemia in Nursing Homes

The pancreas (Refer to Chapter 2)

Informed Consent Form for Testosterone Therapy

DCCT and EDIC: The Diabetes Control and Complications Trial and Follow-up Study

DIABETES CARE. Advice. Blood Pressure. Cholesterol. Diabetes control. Eyes. Feet. Guardian Drugs

NUTRITION OF THE BODY

Section 7-3 Cell Boundaries

How To Know If You Can See Without Glasses Or Contact Lense After Lasik

Carla Duff, CPNP MSN CCRP Clinical Advanced Registered Nurse Practitioner University of South Florida Division of Allergy, Immunology, and

Type 2 Diabetes Type 2 Diabetes

Client Information for Informed Consent TESTOSTERONE FOR TRANSGENDER PATIENTS

Transcription:

Towards an artificial pancreas Patients with diabetes whose blood glucose levels are kept close to normal by means of suitable therapeutic measures avoid the risk of dangerous hypoglycemic episodes and develop complications of diabetes considerably less frequently and later than their less successfully treated counterparts. A precondition for this success is close monitoring of blood glucose levels. Therefore, a great deal of research activity has been directed towards the development of sensors that permit near-painless, continuous measurement of blood glucose level. The objective is to develop a system that pairs continuous blood glucose monitoring with an insulin pump and thus acts as an artificial pancreas.

The days when the only choice open to diabetes sufferers was that between death by coma and death by starvation [1] passed unmourned into history in 1922, when insulin was first used therapeutically. Even today, however, diabetes has lost none of its fearsomeness, because even today diabetics live in constant fear of overdosage or underdosage of their medicines, especially insulin, and of consequent hypoglycemic episodes and late complications 1 that can result from inadequate treatment and prolonged elevation of blood glucose level. The extent to which the blood glucose level of a diabetic can fluctuate is shown by the results of a study in which the blood glucose level of diabetics was measured continuously using the Accu-Chek monitor developed by Roche Diagnostics (blue line in Fig. 1). And the extent to which these fluctuations are missed by blood glucose monitoring systems that take measurements only at longish intervals is shown by the black line in Fig. 1. For reference, the blood glucose level of a healthy individual generally ranges between 70 and 120 mg/dl. Why continuous blood It is difficult to achieve good metabolic control in glucose monitoring is diabetics. Especially in patients on intensive desirable insulin therapy, good metabolic control calls for frequent blood glucose determinations by patients themselves. The timing and dose of insulin injections have to be adapted to a variety of factors that influence blood glucose level, such as carbohydrate intake, physical exertion, sporting activities, stress (including operations, injuries and infections) and also rest periods such as periods spent asleep. In addition to being painful and unpleasant, individual determinations of blood glucose by patients themselves using the conventional invasive techniques provide no more than a snapshot of the patient s blood glucose level at the moment the blood sample was taken. Continuous glucose monitoring (CGM), by contrast, would detect fluctuations in blood glucose level over a prolonged period and indicate when major deviations from the 1 See also p. 13. 60

glucose [mg/dl] 450 400 350 300 250 200 150 100 50 0 begin 12:00 day 1: 12:00 day 2: 12:00 day 3: 12:00 day 4: 12:00 day 5: 12:00 time FIGURE 1: Comparison of the results of a series of individual blood glucose determinations (black line) with those of continuous glucose monitoring in interstitial fluid by means of microdialysis (blue line) in a 47-year-old male type 1 diabetic with a body mass index of 23.8 and an elevated HbA 1c level of 8.7%. It is clearly seen that individual blood glucose determinations fail to detect dangerous hypo- and hyperglycemic phases. (Source of figure: R. Kotulla, F. Hoffmann- La Roche Ltd) normal range occur. Every diabetic could benefit from continuous monitoring of their blood glucose level. Continuous glucose monitoring would be of particular value, however, in in intensive insulin therapy, in which it is difficult or impossible to maintain blood glucose at near-normal levels, and thereby avoid hypoglycemic episodes, on the basis of individual blood glucose determinations, in diabetics in whom the HbA 1c values indicated on p. 49 are not achieved despite intensive insulin therapy, in patients who have suffered repeated hypoglycemic episodes, in pregnant diabetic patients, in whom HbA 1c values fail to detect large fluctuations in blood glucose level, in patients with impaired glucose tolerance and in newly diagnosed type 2 diabetics. Continuous blood glucose monitoring provides far more information than HbA 1c values, commonly regarded as the body s Diabetes mellitus: continuous glucose monitoring 61

implantable sensors microdialysis non-invasive skin skin ISF measuring cell skin measuring cell sensor catheter light sensor in the boby sample taking with extracorporal detection contact-free measurement or probe at the skin surface advantages: small low cost disadvantages: biocompatibility instable sensor advantages: biocompatibility stable performance disadvantages: large expensive advantages: no pain disadvantages: complex technology too many interferences FIGURE 2: Various techniques for continuous glucose monitoring. ISF = interstitial fluid. (Source of figure: R. Kotulla, F. Hoffmann-La Roche Ltd) memory of blood glucose levels. Patients whose level of compliance with their prescribed diet and other therapeutic measures is deficient would see how high their blood glucose level rises and might thereby be motivated to take their treatment more seriously. And of course, continuous glucose monitoring could be of inestimable value as a means of testing the efficacy of new oral antidiabetic agents. The development of a glucose sensor suitable for everyday use that provides a continuous series of values that accurately indicate current blood glucose level is also the first step towards the development of an artificial pancreas. According to Professor T. Koschinsky, everyone involved in the treatment of diabetes will find CGM to be just as important a step forward as was the introduction of self-testing of blood glucose by patients [2]. The basic types of system that can be used for this purpose, and the major advantages and disadvantages of these various systems are summarised in Fig. 2. Clinical studies have shown that CGM can be based equally well on measurement of glucose concentration in interstitial fluid 2 (ISF) as on measurement of glu- 2 Interstitial fluid is found between cells and tissues under the skin. 62

cose concentration in capillary or venous blood [3] (for an explanation of this, please refer to the section on microdialysis). To this end, either the skin must be pierced by minimally invasive glucose sensors (glucose electrodes) or else ISF must be transported out of the body through the skin (e.g. by iontophoresis or microdialysis). In all the systems developed to date, the values measured in ISF are converted into blood glucose values on the basis of periodic parallel blood glucose determinations. Glucose electrodes In mid-1999 the US Food and Drug Administration granted initial, limited approval for the use of subcutaneous (below the skin) glucose sensors produced by Medtronic-MiniMed that perform continuous glucose monitoring in ISF over a period of 72 h. These sensors consist of an electrode whose tip contains the glucose-specific enzyme glucose oxidase. The reaction catalysed by this enzyme gives rise to an electrical signal the strength of which is proportional to the glucose concentration in the ISF. The electrodes are inserted into the patient s subcutaneous fatty tissue. Unfortunately, the electrodes show only limited biocompatibility. The human body reacts to the foreign material and in so doing brings about changes in the sensor surface that result in a reduction in detected signals, i.e. sensor drift occurs [4]. In order to compensate for this drift, at least one blood measurement has to be performed each day for the purpose of calibration. Can it also be done Use of electromagnetic radiation, e.g. light, is one non-invasively? possible way of determining glucose concentration non-invasively, i.e. without puncturing the skin. Potentially, information about glucose concentration can be obtained by measuring either direct interactions between glucose molecules and electromagnetic irradiation (e.g. measurement of light absorption by spectroscopic methods) or indirect effects of glucose on skin properties (measurement of light scatter). However, only near-infrared light in the wavelength range of 600 1300 nm is able to penetrate intact skin to a depth of several centimeters to reach the deeper layers that are perfused by blood [4]. Light of wavelengths below or above this range is absorbed by water, tissue constituents, skin pigment and blood. Diabetes mellitus: continuous glucose monitoring 63

Absorption of light So far, attempts to determine glucose concentration by means of infrared spectroscopy have yielded sufficiently accurate results only in the laboratory, with the aid of a spectrometer. Attempts to measure glucose accurately through the skin of human subjects have failed because the absorption spectrum of glucose in the near-infrared range does not differ sufficiently from that of other tissue constituents. Moreover, the concentrations of glucose found in tissue are very low compared to those of other light-absorbing substances, in particular water, and the relatively small changes in glucose concentration that need to be detected can be calculated only with the aid of complex mathematical algorithms. Scattering of light Calculation of changes in glucose concentration by measurement of diffusely reflected light is actually based on measurement of changes in the refractive index of intracutaneous (within the skin), intravascular (within vessels), interstitial and intracellular fluids. An increase in glucose concentration in these fluids leads to an increase in the refractive index of the fluids concerned. By contrast, the refractive index of the light-scattering interfaces of the skin is unchanged [4]. From these changes in refractive indices, changes in glucose concentration can be calculated. Here again, however, the mathematical analysis is complex, since scattered light is always overlaid by an absorbed component. The fact that both these techniques are highly temperaturedependent has greatly complicated the development of systems for everyday clinical use based on them. Reverse iontophoresis Another possible way of measuring glucose concentration noninvasively is via the sampling of glucose-containing ISF by reverse iontophoresis followed by glucose determination outside the body. In reverse iontophoresis, a weak electrical current is applied to the skin surface in order to transport certain substances (ions, tissue fluid and substances contained therein, e.g. glucose) through the skin and out of the body, instead of into it, as in normal iontophoresis. A system based on this principle and worn as a wristwatch has been available commercially since 2001. A later product based on the same measurement principle 64

has been available since September 2002, however according to its manufacturer, Cygnus, the GlucoWatch G2 Biographer may be used only in combination with a blood glucose measuring device. Calibration with blood glucose values is required each time the sensor is changed, i.e. at intervals of about 13 hours. Profuse sweating or a fall in skin temperature can stop measurement, and the electrical current can cause skin irritation. Simulating the action of Of the various techniques that can potentially be capillaries used for minimally invasive glucose monitoring, microdialysis, which, like reverse iontophoresis, measures glucose concentration in ISF, seems the most promising [5]. Microdialysis technology aims to simulate the action of capillaries [3]. A catheter incorporating a thin dialysis fibre is introduced into the patient s subcutaneous fatty tissue. The fibre is irrigated with isotonic glucose-free fluid. Via pores in the dialysis fibre and catheter, this irrigating fluid (perfusion solution) is in a state of constant interchange with the ISF surrounding the catheter (Fig. 3a). As a result of the prevailing concentration gradient, glucose migrates from the ISF into the glucose-free perfusion fluid. The catheter flow rate is selected so as to establish an equilibrium at the external surface of the catheter, i.e. so that the glucose concentrations inside the catheter and in the ISF are the same. The perfusion solution, enriched in this way with glucose from the ISF, is pumped to a glucose sensor situated outside the body, where its glucose concentration is measured continuously (Fig. 3b). Parallel measurement of the concentration of glucose in the blood and ISF makes it possible to derive blood glucose values from all subsequent ISF glucose values. As glucose is supplied to tissues via the capillaries, abrupt changes in blood glucose levels can cause the glucose levels in the capillaries and ISF to differ (see Fig. 4). In addition to a physiological time lag, a physical time lag must be taken into account in microdialysis. This delay between a change in the value of a parameter and the detection of such a change is a function of the measurement system and is constant for a given measurement system. It depends upon the distance the measurement solution has to traverse from the microdialysis catheter to the measurement site, Diabetes mellitus: continuous glucose monitoring 65

a Waste O 2 GODsolution Sensor Ringer solution b FIGURE 3: Principle of glucose measurement by microdialysis. a) Double-lumen microdialysis catheter for CGM in subcutaneous fatty tissue. Glucose-free perfusion solution is fed into the catheter continuously via a dialysis fibre. The external surface of the catheter is formed by a semipermeable membrane containing pores with a diameter of 20 30 nm. Concentration differences between the interstitial fluid surrounding the catheter and the perfusion fluid in the catheter cause glucose molecules (red) and other molecules with a molecular weight of less than 20 kda to migrate into the catheter. Larger molecules such as proteins have a diameter of 200 300 nm and are therefore unable to pass into the catheter. b) Fluid is pumped continuously out of the catheter. Outside the body, the solution is delivered into a measuring cell and there brought into contact with the enzyme glucose oxidase (GOD). GOD reacts with glucose, in the process releasing hydrogen peroxide, which is detected by an electrode. (Source of figure: R. Kotulla, F. Hoffmann-La Roche Ltd) 66

the perfusion rate, which in this case is between 0.1 and 10 l/min [5] and of course the speed of the detection reaction. The physical time lag of the Accu-Chek monitor developed by Roche Diagnostics is 30 minutes. The Accu-Chek monitor, which is expected to become available for hospital and ambulant use under medical supervision in July 2003, provides the longest period of continuous measurement of any glucose monitoring system developed to date. It permits measurement of glucose levels at 5-minute intervals for four days. This is equivalent to 288 values per day as compared with the 5 8 values that can be obtained using currently available blood glucose selftesting systems. Calibration with a blood glucose value measured in capillary blood is required once every 24 h. The system is well suited to retrospective determination of blood glucose fluctuations and will be an important tool for determining the optimal insulin dosage regimen for individual patients. Outlook Now that a reliable CGM system has been developed, the next step on the road towards an automated or semi-automated pancreas is to pair CGM data with insulin pumps. Such pumps are already available. They permit glucose concentration blood ISF deviation time FIGURE 4: Relationship between glucose concentration in blood and that in interstitial fluid (ISF). (Source of figure: R. Kotulla, F. Hoffmann-La Roche Ltd) Diabetes mellitus: continuous glucose monitoring 67

closed loop system fully automated glucose monitoring and insulin delivery system no user acknowledgemet for insulin using and adjustment signal user open loop system computer semi-automated requires user acknowledgement prior to insulin dosing computer controller portable device glucose sensor pump unit user FIGURE 5: In a fully automated ( closed loop ) artificial pancreas, a computer controls the amount of insulin delivered by a portable insulin infusion pump on the basis of readings obtained by an in-vivo glucose sensor so as to keep the patient s blood glucose at nearnormal levels at all times. The computer calculates the required insulin doses using a feedback algorithm. The first step on the road to such an artificial pancreas is clinical testing of a semi-automated, or open loop, system. In this system, insulin is infused only after acknowledgement or adjustment of the dose by medical staff or the patient. (Source of figure: R. Kotulla, F. Hoffmann-La Roche Ltd) subcutaneous or intraperitoneal (within the peritoneal cavity) administration of insulins. Not withstanding the risk of infections that exists with it, the latter variant, in which the catheter lies free in the peritoneal cavity and the pump is implanted in a pocket of muscle in the abdominal wall, seems preferable, since under physiological conditions the pancreas releases insulin into the circulation via the portal vein. The first organ perfused by blood in the portal vein is the liver. About 50 % of the insulin normally released by the pancreas is absorbed during its first passage through the liver, which is an important organ for the hormonal action of insulin. Half of the insulin released by the pancreas thus fails to reach the peripheral circulation and all the other sites of action of insulin. When administered into the peritoneal cavity, insulin is rapidly absorbed through the peritoneum (the epithelial tissue that lines the abdominal cavity and coats the abdominal and pelvic organs). From there it enters the portal circulation directly. This avoids the peripheral hyperin- 68

sulinemia that can occur with subcutaneous insulin administration [6]. Independently of how, where and in what form insulin is delivered via a pump, however, calculation of the individual insulin doses required is a major problem. Any program designed to calculate the individual insulin doses required must take into account not only the glucose levels measured at the time concerned, but also all the factors referred to above that can influence blood glucose level. For this reason, the first artificial pancreas or to be more precise, artificial pancreatic -cell systems to be developed are probably open loop systems. In these, every insulin dose to be delivered by the insulin pump has first to be acknowledged by the patient (Fig. 5). If the value of such semi-automated systems can be satisfactorily demonstrated in clinical studies, closed loop systems can be developed. In these, CGM and insulin administration would be performed fully automatically with no external intervention. Such systems could greatly simplify the life of insulin-dependent diabetics. Fear of dangerous hypoglycemic episodes would then become definitively a thing of the past. Moreover, the higher cost of such systems as compared with present forms of insulin therapy would without even considering the savings in terms of human suffering be more than offset by huge savings in terms of the cost of dealing with late complications of diabetes such as renal damage, blindness and need for amputations. References 1. Päuser, S.: Lebensrettendes Hormon. mta 2: 86 87, 1999 2. Koschinsky, T.: Subkutanes kontinuierliches Glukosemonitoring neue Techniken und Therapie-Perspektiven. In Scherbaum, W. A. (ed.): Symposium zum 70. Geburtstag von Prof. Dr. med. F. Arnold Gries und zum 25-jährigen Bestehen des Deutschen Diabetes- Forschungsinstituts Düsseldorf 2000, Shaker-Verlag, 2000 3. Mastrototaro, J.J.: The MiniMed continuous glucose monitoring system. Diabetes Technology & Therapeutics 2: 13 18, 2000 4. Heinemann, L.: Minimal-Invasive und Nicht-Invasive Glukose-Sensoren: Stand der Entwicklung. Spektrum Diabetologie, 13 21, 2002 5. Kotulla, R.: Automated near patient measuring of glucose concentration and the way to an automated pancreas. Abstract Series Roche Media Roundtable New Approaches in Diabetes Care, Mannheim 19/20 09 2002 7. Mehnert, H., Standl, E., Usadel, K.-H.: Diabetologie in Klinik und Praxis. Thieme Verlag, Stuttgart, 1999 Diabetes mellitus: continuous glucose monitoring 69