Passive Cooling Systems Air Conditioning Without the Need of Energy

Similar documents
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

8146/5 Series Breaker Panelboards

HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Glossary of Heating, Ventilation and Air Conditioning Terms

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Solar Aquaponics Designing a 100% Solar Aquaponics Greenhouse

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

HVAC: Cool Thermal Storage

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

COMBIMASS. Technical Data COMBIMASS eco-bio +

Using Portable Spot Air Conditioners in Industrial Applications

Technical specifications. Containerized data centre NTR CDC 40f+

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Creating Efficient HVAC Systems

Building Energy Systems. - HVAC: Heating, Distribution -

Nordic Heat Pump Product Guide

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

CONCEPTUALIZATION OF UTILIZING WATER SOURCE HEAT PUMPS WITH COOL STORAGE ROOFS

RiMatrix S Make easy.

Condensing Boiler Efficiency

RPV - RP - RA air handling units

Final Report by Air Conditioner Evaluation Standard Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Rittal Liquid Cooling Series

HEATER, AIR CONDITIONING AND VENTILATION

Solar Thermal Systems

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

HEATING, VENTILATION & AIR CONDITIONING

Lesson 36 Selection Of Air Conditioning Systems

imagine SOLAR AIR CONDITIONING MADE EASY

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

How does solar air conditioning work?

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Cooling Strategies for IT Wiring Closets and Small Rooms

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

HVAC and pressurization. IECEx and ATEX

ECOCIAT. Domestic hot water heat recovery unit

State of the Art Energy Efficient Data Centre Air Conditioning

york air-conditioning products Residential & VRF News 2015

Two-Phase Evaporative Precision Cooling Systems

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

TIPS ON ENERGY SAVING

Glossary of HVAC Terms

Table Z. Troubleshooting Chart for Air Conditioners. Cause

AIR-SITE GROUP. White Paper. Green Equipment Room Practices

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

55 OUTODOOR TOTEM Floorstanding professional Display Enclosure

Thermo Siphon Solar Systems

SWIMMING POOL HEAT PUMP Owners Manual

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

FOXAIR 60/50 ALL MODELS

Electric Process Heaters & Engineered Systems

The days of cheap abundant electricity are over! This article forms part

How to choose a heat pump and use it wisely

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Air Conditioning 101. STN Presentation AC101

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

How a Ground Source Heat Pump Works for a School or College

2.12. page Products for Explosion hazardous Environment

Failure code manual. content

Next Generation Data Center Infrastructure

Automatic Fire Fighting Monitors

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Commissioning - Construction Documents (Page 1 of 6)

Federation of European Heating, Ventilation and Air-conditioning Associations

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

Exemplary Retrofitting of an Old School in Stuttgart - EROS -

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Home Energy Evaluation Report

Thyristor-controlled power supplies and battery chargers

How To Use A Water Source Heat Pump

SECTION HEAT PUMPS

Cooking at the Speed of light!

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Sustainable water heating solutions through solar systems

Transcription:

Passive Cooling Systems Air Conditioning Without the Need of Energy 1 Introduction and Abstract PCS Shelter for ADCO SAS project in the UAE/Sahil and Shah Pipe Lines and Supply Networks often run through remote areas, like deserts, in which no safe power supply is always available. Measuring and supervision might be necessary in these areas too. SCADA systems have usually only small energy consumption and can be powered by solar cells with back-up batteries. The maximum temperatures in the shade can be as high as 58 C and the solar radiation adds additional heat. Without any cooling the temperatures in shelters and housings may exceed 80 C. In these conditions electronic equipment will not function reliably any longer. Active air conditioning systems, such as compressor and absorber air conditioners, require too much energy to function with solar cells. The solution is passive cooling. How does that function? Passive Cooling Systems use the high temperature differences ( T) between day and night, which arise in arid desert regions. The thermal capacity of heat distribution medium, e.g. water, stores the coolness of the night to keep the interior at a moderate temperature during the day. A Passive Cooled Shelter is an integral system consisting of housings with insulation, sun shade, external and internal heat exchangers, heat storage and conveyance of the medium, which must be designed for the specific application. INTERTEC engineered, built and supplied a number of passively cooled cabinets and shelters for projects of customers such as Saudi Aramco, ADCO, TR, Siemens, ABB or Cegelec with the self developed dynamic simulation tool INTERSIM.

2 Function principle Passive cooling systems function by a large heat storage. Water, having a large thermal capacity, is a very good medium for storing and distributing the coolness of the night. Passive Cooling System: Principle External Heat Exchangers Internal Heat Exchangers High Thermally Stratified Water Tank as Heat Storage Passive Cooling System: Day Outside hotter than inside: outside circuit switched off Cold water from the tank cools the interior CD200-2e-Brochure_Passive_Cooler 2

Passive Cooling System: Night The coolness of the night cools the tank: outside circuit active Cold water from the tank cools the interior The 'temperature peaks' are leveled off. Theoretically the cooled interior temperature to maintain is limited to the ambient temperature of the night before. 50 Environment Air in Shelter Tank Heat Exchanger outside Heat Exchanger inside 45 Temperature [ C] 40 35 30 25 6:00 12:00 18:00 0:00 6:00 12:00 18:00 0:00 6:00 Time CD200-2e-Brochure_Passive_Cooler 3

3 Lay Out of the Passive Cooling System with the dynamic simulation tool 'INTERSIM' INTERSIM is based on an electrical comparison model of a resistance network with resistances and capacities. The passive cooling system can be simulated and laid out exactly. INTERTEC has designed, built and performance tested a number of passive cooled shelters. At every project, the theoretical values could be adjusted to the measured values. Therefore the simulation is quite exact meanwhile. The simulation can be based on a simplified outside temperature gradient or, if known in the real, measured temperature trend. CD200-2e-Brochure_Passive_Cooler 4

4 Selection of the Right Type of Passive Cooler The most important parameters to lay out a passive cooler are: the heat dissipation of the equipment in the housing ( average over 24 h ) the night outside air temperature of the night before the hottest day. The max. allowed temperature inside the shelter. The difference between the mentioned temperatures (delta T) is the driving force to transport the heat out of the housing. The numbers mean the approx. cost for the passive cooling system (without housing etc.) CD200-2e-Brochure_Passive_Cooler 5

4.1 FC-PCS : Forced Circulation Passive Cooled Shelters SCADA Shelter for a drinking water pipeline in the UAE/Fujaihra The liquid circulation of this type of passive cooled shelters is operated by 12V DC pumps. The electrical energy consumption averages at only 10 W. totally. The required energy, if not available, can be provided by solar panels. This concept as a rule of thumb doubles the performance of the PCS Why? The performance of a passive cooler is limited by the sum of the temperature differences (delta T). The minimum practical delta T for a natural convection cycle is 3 K. A forced convection by small pumps needs practically no delta T, that saves 2 x 3 K = 6 K, the internal temperature can be 6 K lower at the same size of heat exchangers and tank. Delta T of the heat exchangers Delta T for the natural convection CD200-2e-Brochure_Passive_Cooler 6

Advantages of FC-PCS : Forced Circulation Passive Cooled Shelters heat exchanger position can be designed to practical needs, i.e. at walls => Outside heat exchangers are easy accessible for cleaning after a sand storm. Minimized over all dimensions: Makes it possible to ship the passive cooled shelter in one piece using the ISO container dimensions = moderate shipping cost. Enables Direct cooling of electronic components by conduction Thermal conduction is a much (approx. 10 times) more effective heat transfer mechanism than the convection of air. Heat exchanger, can be mounted directly to the objects that need to be cooled or heated. Redundant, very reliable brush less, magnetic coupled pumps 4.2 PCS : Natural Circulation Passive Cooled Shelter Without any energy supply 4.2.1 SCADA Shelters for 64 well head stations of the ADCO SAS project External Heat Exchanger and Sun Shade Internal Heat Exchangers 8000 l Tank CD200-2e-Brochure_Passive_Cooler 7

4.2.2 SCADA Shelter of an oil pipeline in the Sudan/Muglad A 'classical' passive cooling with liquid cycle by natural convection. With 500 W, very massive pipes are necessary to minimize the flow resistance. The top part with the outside heat exchangers was transported separately and installed on site. CD200-2e-Brochure_Passive_Cooler 8

4.2.3 Analyzer station in a power plant in the Middle East A Classic cabinet with a passive cooling system that does not need any energy. The utilizable volume amounts to approx. 150x100x50cm (HxBxD). Depending on climate conditions an inside temperature can be held by 40 C with an energy dissipation from 30 W to 100 W. The Passive Cooler concept is a simple and competitive alternative for very expensive Exproof airconditioning units. CD200-2e-Brochure_Passive_Cooler 9

4.3 Passive Cooling solutions without heat exchangers 4.3.1 PCM passive cooler Designed for installation of small devices (transmitters or electronic modules) with heat dissipation of 10 W or less to maintain the temperature of the electronics 10 K below the peak ambient temperature. Advantages No energy or power supply required Cost effective Maintenance free IP65 up to IP68, no fan or louvers to reduce the IP rating Very rugged design Solid state, no moving parts PCM Material Mounting Plate Device All components are designed for optimal performance: Arctic PP enclosures with excellent insulation properties and no heat sinks PCM ( phase change material ), a material that melts and freezes at 93 F/ 34 C and stores the resulting energy at this level Optimal installation: no heat sinks to ambient conditions, good heat transfer between instrument and PCM due to heat conduction. Sun shade, not only on top of the enclosure, but along sides, if necessary CD200-2e-Brochure_Passive_Cooler 10

4.3.2 passive cooled enclosure for the satellite SCADA system of a gas distribution network In this case for a satellite SCADA system of a gas distribution network the electronics had to be proteded against temperature peaks of only few hours. Due to the precisiely defined thermal insulation of the enclosure and the sun shade, the thermal capacity of the leadacid battery is enough, to limit the temperatuer of the SCADA controller to 60 C at a heat dissipation of 5 W. Testing in a climate chamber CD200-2e-Brochure_Passive_Cooler 11

5 Guide Lines for Optimal Specification 5.1 To optimize the temperatures and power means to minimize the cost The temperature differences (delta Ts) in a Passive Cooling System are much smaller than in an active air conditioner. That means that every C, Kelvin or Fahrenheit is very valuable. Example: In a typical application +50 C day / +30 C night the size of heat exchangers and tank to maintain 40 C inside is more than double the size to maintain 45 C. At the other hand it is important to specify the right Wattage of the heat loss of the electrical equipment. Every Watt of heat energy has to be stored during the day and transported to the outside during the night. Please see also the INTERTEC document Every C counts.pdf 5.2 Size Passive cooled shelters should not been oversized. Good thermal insulation is mandatory because the passive cooling system gets very big and expensive when the necessary cooling power is high. Every m² of outside surface causes additional heat ingress. 5.3 Thermal Insulation Very good thermal insulation is the base of the function of a passive cooled shelter. The whole structure has to be designed avoiding thermal short-cuts. At the usual shelter design heat sinks like steel beams, door frames and cable ducts cause a huge loss of cooling energy. 5.4 Transportation To design the shelter layout to a maximum width of 2.28 m (which is the ISO sea container s inside width) can save a lot of transportation and packing cost. It makes sense to pack the completely installed shelter inside an open top ISO container. So it can be transported from the place of manufacturing to the final destination at moderate cost without the danger of being damaged. Seaworthy packing is not necessary because the GRP shelter itself has a high degree of ingress protection and is corrosion resistant. 5.5 Sun Shade To avoid a high additional heat power by sun radiation it is absolutely necessary to place the shelter in the shade. INTERTEC usually ships shelters with an integrated sun shade. It is removable and stored inside shelter during transportation. Ladder for roof access not necessary and useless unless equipment like the solar panels are installed on the roof. Solar panels can be used as sun shade. It is important that the panels are easily accessible to remove the dust after a sand storm. 5.6 Explosion proof requirements Ex Zone: if necessary, the passive cooled shelter has to meet the requirements of IEC 60079-0 ff. (Antistatic, installations etc.) Battery room: if the batteries produce hydrogen during charging, the battery room might be Ex-Zone 2 or 1. CD200-2e-Brochure_Passive_Cooler 12

6 Alternative Solutions for Outdoor Thermal Management Please contact the INTERTEC engineering department to select the optimal solution for you application. 6.1 The Use of Colder Media If cooling water is available, which must be only colder 2-3 K than the required interior temperature, there might not be a need for a water tank. The heat exchanger can be designed accordingly, which simplifies the Passive Cooler. Other Options: filter fan air-to-air heat exchangers instrument air Vortex - cooler Peltier - cooler Electrical heating for condensation protection The silver bullet solution: Avoid cooling by intelligent combination of well insulated enclosure and equipment condensation protection Water Cooled Gas Chromatograph for a Gas Plant in the Gulf area 6.2 Hybrid : Combination of Active and Passive Cooler In this case the active cooler can be laid out small without reserves and redundancy. The passive cooler ( e.g. PCM passive cooler ) acts as a Booster for the hottest hours of the hottest days back-up for some hours until the active cooler is repaired CD200-2e-Brochure_Passive_Cooler 13

6.3 ATEX- Air Conditioning Unit The air conditioning unit has been designed for installation on the external wall of the protective cabinet or shelter. It is suitable for application in the open at ambient temperatures ranging from 35 C to + 55 C. Ex-approval allows for application up to zone 1. The components of the air conditioning unit are accommodated in a corrosion-proof housing made of the same material as the INTERTEC protective cabinets. For custom applications, INTERTEC can supply complete units consisting of an air conditioning unit and a protective cabinet or Explosion Protection ATEX Examination Certificate TÜV 06 ATEX 2958 ATEX Type of protection (Gas) II 2G Ex px mb e IIC T3 (Suitable for Zone 1) CSA Certificate CSA File # 1913298 CSA Type of Protection Class 1, Div. 2, Class 1, Zone 1, Groups A, B, C and D shelter. Protective cabinets can also be supplied in Ex p design. 6.4 ATEX Ex p Purged and Active Cooled Video Surveillance System for a Refinery in Algeria Cold air from an very well insulated INTERTEC GRP shelter for the concentrator with INTERTEC ATEX air conditioner is conducted to very well insulated INTERTEC GRP sandwich camera boxes by hoses. This solves several problems: ATEX Zone 1 certified ( equipment inside non Ex ) Equipment kept cool ( ambient temperature up to 100 C ) Environmental protection ( sand, corrosion ) Theft and vandalism protection CD200-2e-Brochure_Passive_Cooler 14

6.5 ATEX Water Chiller and Analyzer Cabinet For Saudi Aramco Haradh Al Crude Increment III Gas and Oil Separator Plant in Saudi Arabia. A closed loop water/glycol circulation cools the sample and the cabinet of an oil in water analyzer. ATEX 10 kw water chiller Analyzer Cabinet 6.6 Water Cooled Cabinet for Yokogawa GC in Syria Cabinet and process air for the Gas Chromatograph is cooled with cooling water. An explosion proof control system with thermostats and solenoid valves controls the temperature. Air Cooler CD200-2e-Brochure_Passive_Cooler 15

7 Advantages of INTERTEC Passive Cooling Systems No or very small (< 10 W) auxiliary energy needs. high reliability, no or almost no moving parts closed loop system=>no evaporation=>no maintenance Custom designs according for the application and needs. No transition through the roof that could leak Options High wind loads Explosion proof Fire rating ( i.e. F30 ) Earth quake proof Many more No water above electronic panels External Heat Exchangers: Integrated in the sun shade panel Internal Heat Exchangers at sandwich walls don t need much space High thermally stratified storage tank Tank stands solid on the floor GRP sandwich Shelter High IP rating (e.g. IP65) Insulation ensures good K-value and limits required cooling. Optimized design avoids thermal short-cuts and heat sinks Flexible and modular system Chemical and corrosion resistant No maintenance cost Light weights (transport), high stability Complete integration and configuration from one hand INTERTEC can offer in house: Engineering, Lay out Production, Assembly Testing and Documentation Of Shelter Passive Cooling System electrical (power distribution, lighting) and mechanical installations CD200-2e-Brochure_Passive_Cooler 16