Major pitfalls in updating an accident sequence analysis with MELCOR: from 1.8.4 to 1.8.6 YT versions

Similar documents
Transport and chemistry of fission products (TRAFI)

Status on Spanish Regulations and Industry. actions related to Filtered Containment. Venting Systems (FCVS)

SCDAP/RELAP5-3D : A State-of-the-Art Tool for Severe Accident Analyses

For further information regarding this document please contact

Source Term Determination Methods of the Slovenian Nuclear Safety Administration Emergency Response Team

Research on the Transport and Chemistry of Fission Products in Primary Circuit and Containment Conditions at VTT

Analysis of In-Vessel Retention and Ex-Vessel Fuel Coolant Interaction for AP1000

Achim Beisiegel Fouad El-Rharbaoui Michael Wich. AREVA GmbH, Technical Center, Karlstein, Seligenstädter Strasse 100, Germany

Introduction to Nuclear Fuel Cycle and Advanced Nuclear Fuels

Fukushima Daiichi Accident Study (Status as of April 2012)

SOURCE TERMS FOR POTENTIAL NPPS AT THE LUBIATOWO SITE, POLAND

EPA Radionuclides Rule and the RadNet Program

Results of Airborne Monitoring by the Ministry of Education, Culture, Sports, Science and Technology and the U.S. Department of Energy

A Review of Emerging Gamma Detector Technologies for Airborne. Radiation Monitoring

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

V K Raina. Reactor Group, BARC

RESULTS OF R&D ON FUTURE FUEL CYCLE AND ASSOCIATED HL WASTE DISPOSAL: THE FRENCH CASE

Nuclear Design Practices and the Case of Loviisa 3

IAEA-TECDOC Application of simulation techniques for accident management training in nuclear power plants

10 Nuclear Power Reactors Figure 10.1

Safety of New Nuclear Power Plants

Cleaning and Support Services / Cleaning Services Supervision National Occupational Standards

EMERGENCY PREPAREDNESS FREQUENTLY ASKED QUESTION (EPFAQ) NEI REVISIONS 4 THROUGH 6; NUMARC/NESP 007

Rack Blanking Panels To Fill or Not to Fill

CFD simulation of fibre material transport in a PWR core under loss of coolant conditions

Sugars Program Update For Windows - Beet Sugar

Ways We Use Integers. Negative Numbers in Bar Graphs

HEALTH & SAFETY EXECUTIVE NUCLEAR DIRECTORATE ASSESSMENT REPORT. New Reactor Build. EDF/AREVA EPR Step 2 PSA Assessment

HYBRID COMBINED CYCLE POWER PLANT

Simulation of a small size solar assisted adsorption air conditioning system for residential applications

Software Safety Basics

Global Nuclear Energy Partnership Technology Demonstration Program

Pool Dehumidification Basics


Comparison of natural radioactivity removal methods for drinking water supplies: A review

Belgian Stress tests specifications Applicable to power reactors 17 May 2011

Belgian Stress tests specifications Applicable to all nuclear plants, excluding power reactors 22 June 2011

Temelin NPP Risk Panel A PSA and Safety Monitor Application. Workshop Information IAEA Workshop

Deposition Velocity Estimation with the GENII v2 Software

Radiological objectives and severe accident mitigation strategy for the generation II PWRs in France in the framework of PLE

A COMPUTER CONTROLLED SYSTEM FOR WATER QUALITY MONITORING

SPRAY FOAM INSULATION AND COASTAL FLOODING

CFD Topics at the US Nuclear Regulatory Commission. Christopher Boyd, Ghani Zigh Office of Nuclear Regulatory Research June 2008

High Performance PSA in Sheet Membrane in Water Protection

Optimizing Tank Cleaning Operations

Loviisa 3 unique possibility for large scale CHP generation and CO 2 reductions. Nici Bergroth, Fortum Oyj FORS-seminar

N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios

Diablo Canyon NPP Probabilistic Risk Assessment Program. Workshop Information IAEA Workshop

CHAPTER 2 HYDRAULICS OF SEWERS

Operating Performance: Accident Management: Severe Accident Management Programs for Nuclear Reactors REGDOC-2.3.2

RIC 2007 SNAP: Symbolic Nuclear Analysis Package. Chester Gingrich USNRC/RES 3/13/07

Safety Analysis Probabilistic Safety Assessment (PSA) for Nuclear Power Plants REGDOC-2.4.2

IAEA INTERNATIONAL FACT FINDING EXPERT MISSION OF THE FUKUSHIMA DAI-ICHI NPP ACCIDENT FOLLOWING THE GREAT EAST JAPAN EARTHQUAKE AND TSUNAMI

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Approved baseline and monitoring methodology AM0056

Boiling Water Reactor Systems

8 Emergency Operating Procedures (EOPs) and Severe Accident Management Guidelines (SAMGs) - Issue 06

Part and tooling design. Eastman Tritan copolyester

Future Value of an Annuity Sinking Fund. MATH 1003 Calculus and Linear Algebra (Lecture 3)

Spacecraft Power for Cassini

Circulator Fan Performance Testing Standards BY CHRISTIAN TABER, BEMP, HBDP, MEMBER ASHRAE

Safety Analysis for Nuclear Power Plants

May 23, 2011 Tokyo Electric Power Company

4D v11 SQL Release 6 (11.6) ADDENDUM

GENERAL CARPET CARE MAINTENANCE - VACUUMING

Application Note. ipix A Gamma imager to support various applications

Government Degree on the Safety of Nuclear Power Plants 717/2013

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

SOLVING REACTOR WATER CLEAN-UP SYSTEM ANOMALIES USING RELAP5 MOD3.3

Adverse Impact Ratio for Females (0/ 1) = 0 (5/ 17) = Adverse impact as defined by the 4/5ths rule was not found in the above data.

Targeted Risk Assessment Addendum to the User Guide for the Standalone Consumer Tool Version 3.1 -

ITS-Enterprise Business Services. Employee Web Kiosk. Approver Training

Workshop 7 PC Software - Tracker

9 th Grade Physical Science Springfield Local Schools Common Course Syllabi. Course Description

Post- Fukushima accident. Spain. Peer review country report. Stress tests performed on European nuclear power plants. Stress Test Peer Review Board

STATFlow. Direct-to-Drain System. For use with STATIM 2000 and STATIM 5000 Autoclaves. Installation Guide and Operator s Manual

AP ENVIRONMENTAL SCIENCE 2012 SCORING GUIDELINES

Using Risk Assessment Tool to Evaluate the Fire-Induced Core Damage Frequency

Announcement of a new IAEA Co-ordinated Research Programme (CRP)

Experiment 12E LIQUID-VAPOR EQUILIBRIUM OF WATER 1

Kiln Drying Planning Tool. User Guide

FINACS INVENTORY Page 1 of 9 INVENTORY TABLE OF CONTENTS. 1. Stock Movement Physical Stock Adjustment...7. (Compiled for FINACS v 2.12.

Nuclear Criticality Safety Division TRAINING MODULE CSG-TM-016 COG SOFTWARE

Department of Environmental Health and Safety & Emergency Management

A Practical Guide to Free Energy Devices

USER S MANUAL. ArboWebForest

Japan s current Nuclear Energy Policy

Work and Energy. Work = Force Distance. Work increases the energy of an object. Energy can be converted back to work.

PWR circuit contamination assessment tool. Use of OSCAR code for engineering studies at EDF

Microsoft Mathematics for Educators:

COFRENTES NPP. March 14, Iberdrola Generación, SA Producción Nuclear Iberdrola Generación, SA Producción Nuclear 1

Radioactivity III: Measurement of Half Life.

Transcription:

Major pitfalls in updating an accident sequence analysis with MELCOR: from 1.8.4 to 1.8.6 YT versions M. García, B. Otero, L.E. Herranz Unit of Nuclear Safety Research CIEMAT, SPAIN OUTLINE 1. Introductory Remarks 2. Scenario Description 3. 4. Pitfalls Final Remarks

1. Introductory Remarks AR-PHEBUS project: Analysis of Level 2 PSA sequences of Spanish NPPs taking into account the recent developments in MELCOR and from the PHEBUS FP project This work have been carried out under the sponsorship of Consejo de Seguridad Nuclear (AR- PHEBUS agreement) The objectives of this project are: To asses how relevant MELCOR updates are in terms of severe accident sequences To check the effect of including Iodine Chemistry on the MELCOR estimates Ciemat experience with MELCOR code is limited to: PHEBUS Tests: FPT1 and FPT2 (containment THs, aerosol behaviour and Iodine chemistry) Sequence of ASCÓ NPP (full sequence from core degradation to releases to environment) The objective of this presentation is to report on the problems found when analyzing a full sequence of ASCÓ NPP They should not be necessarily associated to the MELCOR code. But, even if they are not, it could be of some interest to know where newcomers find pitfalls in MELCOR applications

2. Scenario description 2.a. ASCÓ NPP Westinghouse design Power: 940 MW(e) Dry containment

2. Scenario description 2.b. Sequence description ALNDRF8 chosen from ASCÓ PSA LEVEL 2 Characteristics: Large LOCA Low pressure (below 13.6 bar) Neither the sprays nor the fan coolers available Dry cavity Low-pressure recirculation failed Accident progression: Large (10 ) break in one of the cold legs of the RCS Core damaged at 0.16 hours RPV failure at 3 hours Containmet pressurized steadily (due to MCCI + absence of fan coolers) H 2 deflagration in the short term (< 10 hours)

3. Pitfalls 3.a. Input Deck (I): The 185 input deck build up European MELCOR User Group, 2008 OBJECTIVE: to run ALNDFR8 sequence and compare MELCOR estimates (184-185) Manual modifications in the COR and DCH packages: COR package: distinguish between SS and NS and define its temperatures, equivalent diameters and surfaces. DCH package: New record (DCHFPOW) to define the total thermal operating power due to fission and decay of U-235, Pu-239 and U-238 nuclides. PITFALLS Unavailable graphic tools to extract the information of 184 OUT file Consistency errors between COR and CVH packages Cavity errors messages DONE!! Hisptlm.exe SOLUTIONS Exhaustive revision of the MELCOR 185 user guide.

3. Pitfalls 3.a. Input Deck (II): The 186 input deck build up OBJECTIVE: to run ALNDFR8 sequence and compare MELCOR estimates (185-186) Modifications with MELCOR Input Deck Converter : creation of the LHMP text file. PITFALLS Many code crashes Warnings in.gdia file: SOLUTIONS Manual modifications following the MELCOR 186 user guide Warnings from subroutine CORICV altitudes in CVH volume altitude tables do not match COR cell elevations DONE!!

3. Pitfalls 3.b. Activation of Iodine Chemistry Introduce new records to activate the Iodine Chemistry Model Define new necessary radionuclide classes with this model PITFALLS SOLUTIONS Many code crashes Change DTmax-DTmin MELCOR 186YT- 1010 Crash time = f (PC) MELCOR 186YR Fail to PLOT variables Wrong PTFread chosen

3. Pitfalls 3.c. P(with IC)/P(without IC) 2.0 1.5 1.0 0.5 Results Analysis (I) Containment Pressure Does the Iodine Chemistry Model CONDITION the integration time intervals? 0.0 0 50000 100000 150000 200000 250000 Time (s)

3. Pitfalls 3.c. 2.0 Results Analysis (II) H 2 Generation H2(with IC)/H2(without IC) 1.5 1.0 0.5 0.0 0 50000 100000 150000 200000 250000 Time (s)

3. Pitfalls 3.c. Results Analysis (III) Without IC With IC (t = 0 s) With IC (t = 9000 s) /SMESSAGE/ TIME= 3.63963E+00 CYCLE= 82 CF0500 - MESSAGE FROM CONTROL FUNCTION PACKAGE CONTROL FUNCTION 500 - RPS-PPZR BECAME.TRUE. /SMESSAGE/ TIME= 3.68026E+00 CYCLE= 68 CF0500 - MESSAGE FROM CONTROL FUNCTION PACKAGE CONTROL FUNCTION 500 - RPS-PPZR BECAME.TRUE. /SMESSAGE/ TIME= 3.68026E+00 CYCLE= 68 CF0500 - MESSAGE FROM CONTROL FUNCTION PACKAGE CONTROL FUNCTION 500 - RPS-PPZR BECAME.TRUE. /SMESSAGE/ TIME= 8.15162E+03 CYCLE= 25931 COR0002: MESSAGE FROM CORE PACKAGE BEGINNING OF DEBRIS EJECTION TO CAVITY /SMESSAGE/ TIME= 7.40969E+03 CYCLE= 27728 COR0002: MESSAGE FROM CORE PACKAGE BEGINNING OF DEBRIS EJECTION TO CAVITY /SMESSAGE/ TIME= 7.80817E+03 CYCLE= 26797 COR0002: MESSAGE FROM CORE PACKAGE BEGINNING OF DEBRIS EJECTION TO CAVITY

3. Pitfalls 3.c. Results Analysis (IV) Fission products classes Iodine chemistry speciation Unclear match IM ( pool iodine bound in chemical species other than I 2 or CsI Adding up all the iodine species other than I 2 or CsI is hard to get the same IM figure CH 3 I origin No organics added in the system or cable/coatings defined A noticiable fraction of CH 3 I found Where does it come from? (Is it a default amount?)

4. Final Remarks More user-friendly tools to make MELCOR new versions compatible with previous versions input decks would be welcome Intricate procedure to make Iodine pool model run, a more straightforward way would be recommendable (i.e., extra RN and deposition classes defined out of the IPM records) Link between IC activation and MELCOR running unclear Efforts have been made to make IPM easier to use by MELCOR developers; nevertheless, the analysis of IPM results is not simple Thanks to the MELCOR development team for their technical support during this work

THANK YOU FOR YOUR ATTENTION